977 resultados para high-definition television (HDTV)
Resumo:
In modern magnetic resonance imaging (MRI), patients are exposed to strong, rapidly switching magnetic gradient fields that, in extreme cases, may be able to elicit nerve stimulation. This paper presents theoretical investigations into the spatial distribution of induced current inside human tissues caused by pulsed z-gradient fields. A variety of gradient waveforms have been studied. The simulations are based on a new, high-definition, finite-difference time-domain method and a realistic inhomogeneous 10-mm resolution human body model with appropriate tissue parameters. it was found that the eddy current densities are affected not only by the pulse sequences but by many parameters such as the position of the body inside the gradient set, the local biological material properties and the geometry of the body. The discussion contains a comparison of these results with previous results found in the literature. This study and the new methods presented herein will help to further investigate the biological effects caused by the switched gradient fields in a MRI scan. (C) 2002 Wiley Periodicals, Inc.
Resumo:
A new high throughput and scalable architecture for unified transform coding in H.264/AVC is proposed in this paper. Such flexible structure is capable of computing all the 4x4 and 2x2 transforms for Ultra High Definition Video (UHDV) applications (4320x7680@ 30fps) in real-time and with low hardware cost. These significantly high performance levels were proven with the implementation of several different configurations of the proposed structure using both FPGA and ASIC 90 nm technologies. In addition, such experimental evaluation also demonstrated the high area efficiency of theproposed architecture, which in terms of Data Throughput per Unit of Area (DTUA) is at least 1.5 times more efficient than its more prominent related designs(1).
Resumo:
A novel high throughput and scalable unified architecture for the computation of the transform operations in video codecs for advanced standards is presented in this paper. This structure can be used as a hardware accelerator in modern embedded systems to efficiently compute all the two-dimensional 4 x 4 and 2 x 2 transforms of the H.264/AVC standard. Moreover, its highly flexible design and hardware efficiency allows it to be easily scaled in terms of performance and hardware cost to meet the specific requirements of any given video coding application. Experimental results obtained using a Xilinx Virtex-5 FPGA demonstrated the superior performance and hardware efficiency levels provided by the proposed structure, which presents a throughput per unit of area relatively higher than other similar recently published designs targeting the H.264/AVC standard. Such results also showed that, when integrated in a multi-core embedded system, this architecture provides speedup factors of about 120x concerning pure software implementations of the transform algorithms, therefore allowing the computation, in real-time, of all the above mentioned transforms for Ultra High Definition Video (UHDV) sequences (4,320 x 7,680 @ 30 fps).
Resumo:
This paper presents the implementation of the OFDM demodulator and the Viterbi decoder, proposed as part of a wireless High Definition video receiver to be integrated in an FPGA. These blocks were implemented in a Xilinx Virtex-6 FPGA. The complete system was previously modeled and simulated using MATLAB/Simulink to extract importante hardware characteristics for the FPGA implementation.
Resumo:
No último século, o sector das comunicações passou de um estado inicial de simples curiosidade tecnológica até um dos mais dinâmicos pilares económicos de vários países por todo o mundo. A procura por mais e melhores serviços de televisão e internet levaram à necessidade de evoluir as tecnologias existentes de modo a conseguir cumprir com a elevada procura ao mesmo tempo que apresentam um serviço mais rápido, mais fiável e de melhor qualidade. A União Europeia (EU) colocou como objetivo a conversão de todo o seu território de radiodifusão analógica para a tecnologia digital. Deste modo, não só se conseguiu uma mais eficiente utilização do espetro radioelétrico, como se conseguiu aumentar o número de canais a transmitir, sendo estes de melhor qualidade que a tecnologia analógica, pois deu a possibilidade de várias emissoras poderem emitir em High Definition (HD).
Resumo:
The colors that are seen in dermoscopy depend on the anatomic level of the skin at which the chromophores are seen. Blue color can be found in a variety of melanocytic and nonmelanocytic lesions. An 89-year-old man presented with a 3-year history of a slow-growing, hyperpigmented patch located on the distal third of the right arm. Dermoscopy showed an atypical network, irregularly distributed globules, pigmented internal streaks and a milky-red area. Based on these findings a diagnosis of slow-growing malignant melanoma was made. Simultaneously, a well-defined blue papule was seen on the proximal third of the same arm. Dermoscopy disclosed a homogeneous blue pattern. After clinical and dermoscopic correlation our differential diagnosis for this blue lesion included cutaneous melanoma metastasis, blue nevus and foreign body reaction. The patient recalled its onset 75 years ago after a grenade explosion. We also discuss the blue lesion appearance under reflectance confocal microscopy and high-definition optical coherence tomography. Histopathological examination after excision of the hyperpigmented patch and blue papule revealed a melanoma in situ and a foreign body reaction, respectively. The diagnostic evaluation of a blue lesion should always rely on the integration of all data, especially clinical and dermoscopic features. Other non-invasive techniques, like reflectance confocal microscopy and high-definition optical coherence tomography can also be important aids for its differential diagnosis.
Resumo:
Neste trabalho, multifilamentos ocos de polipropileno foram estudados com o objetivo de construir um fantoma cerebral adequado à validação e controlo de qualidade de uma modalidade de imagem clínica inovadora: High-Definition Fiber Tractography. Foram investigadas e discutidas a análise à secção transversal e a redução da área de multifilamentos ocos de polipropileno, através de estiramento. De acordo com os resultados experimentais, a dimensão da secção transversal dos multifilamentos é proporcional à massa linear dos mesmos, existindo uma irregularidade, relativamente, à forma deste tipo de materiais.
Resumo:
The currently available clinical imaging methods do not provide highly detailed information about location and severity of axonal injury or the expected recovery time of patients with traumatic brain injury [1]. High-Definition Fiber Tractography (HDFT) is a novel imaging modality that allows visualizing and quantifying, directly, the degree of axons damage, predicting functional deficits due to traumatic axonal injury and loss of cortical projections. This imaging modality is based on diffusion technology [2]. The inexistence of a phantom able to mimic properly the human brain hinders the possibility of testing, calibrating and validating these medical imaging techniques. Most research done in this area fails in key points, such as the size limit reproduced of the brain fibers and the quick and easy reproducibility of phantoms [3]. For that reason, it is necessary to develop similar structures matching the micron scale of axon tubes. Flexible textiles can play an important role since they allow producing controlled packing densities and crossing structures that match closely the human crossing patterns of the brain. To build a brain phantom, several parameters must be taken into account in what concerns to the materials selection, like hydrophobicity, density and fiber diameter, since these factors influence directly the values of fractional anisotropy. Fiber cross-section shape is other important parameter. Earlier studies showed that synthetic fibrous materials are a good choice for building a brain phantom [4]. The present work is integrated in a broader project that aims to develop a brain phantom made by fibrous materials to validate and calibrate HDFT. Due to the similarity between thousands of hollow multifilaments in a fibrous arrangement, like a yarn, and the axons, low twist polypropylene multifilament yarns were selected for this development. In this sense, extruded hollow filaments were analysed in scanning electron microscope to characterize their main dimensions and shape. In order to approximate the dimensional scale to human axons, five types of polypropylene yarns with different linear density (denier) were used, aiming to understand the effect of linear density on the filament inner and outer areas. Moreover, in order to achieve the required dimensions, the polypropylene filaments cross-section was diminished in a drawing stage of a filament extrusion line. Subsequently, tensile tests were performed to characterize the mechanical behaviour of hollow filaments and to evaluate the differences between stretched and non-stretched filaments. In general, an increase of the linear density causes the increase in the size of the filament cross section. With the increase of structure orientation of filaments, induced by stretching, breaking tenacity increases and elongation at break decreases. The production of hollow fibers, with the required characteristics, is one of the key steps to create a brain phantom that properly mimics the human brain that may be used for the validation and calibration of HDFT, an imaging approach that is expected to contribute significantly to the areas of brain related research.
Resumo:
OBJECTIVE: : Intravascular ultrasound (IVUS) generates high definition circumferential cross-sectional images and provides real-time readout of vascular dimensions, including visualization of vessel branches. We have used it as an alternative to angiography in the endovascular thoracic aneurysm repair work-up. METHODS: : Out of consecutive 203 patients with descending thoracic aortic aneurysm, 89 (43.8%) received endovascular treatment [mean age, 68 ± 8 years; range, 29-82; male, 79 (88.7%); female, 10 (11.3%)] without using angiography during the endovascular procedure. IVUS (6 F, 12.5 MHz probe or 10 F 9 MHz) coupled with fluoroscopy for the placement of radiopaque markers was used for target site identification, landing zone measurement, device positioning, and assessment of endovascular repair. RESULTS: : Hospital mortality was 4/89 (4.5%). Number of devices implanted in each patient was 1.2 (range, 1-3). X-ray exposure time was 12 ± 8 minutes. Median procedure time was 63 ± 20 minutes. Conversion to open surgery was necessary in one patient (1.1%) because of aortic dissection. In nine patients (10.1%) left subclavian artery was covered because of a short neck. Two patients (2.2%) had vascular access lesions and required surgical repair. One patient developed paraplegia (1.1%). Early endoleak was observed in eight patients (8.9%) and 4 (4.5%) required additional procedures (proximal or distal extensions). Late conversion was necessary in one patient (1.1%). CONCLUSIONS: : IVUS provides all information necessary for device selection, target site identification as well as safe and correct deployment of thoracic endoprostheses and makes periprocedural angiography unnecessary, thus avoiding the risk of renal failure because of contrast medium.
Resumo:
Els avenços tecnològics en els camps de la informàtica i l'entreteniment ha evolucionatmolt ràpidament els darrers anys.Els ordinadors han augmentat la seva potència, han anat adquirint capacitats multimèdia i han arribat al punt de poder reproduir tranquil·lament els nous formats d'alta definició.El televisors i reproductors han passat un procés de sofisticació, el qual els ha dotat de noves característiques, com el teletext, el suport per les funcionalitats de la tdt i capacitat per reproduir formats provinents del àmbit informàtic.Per tant no seria estrany que tots dos mons acabin convergint, de manera que puguemdotar el menjador de casa amb les capacitats que han estat exclusives del món informàtic.Amb el temps han anat apareixent solucions que pretenien cobrir aquestes necessitats,amb més o menys èxit, però amb diversos inconvenients, ja que no deixaven de ser unpedaç sobre un aparell "tradicional".La finalitat d'aquest projecte és la de construir un HTPC (Home Theater PC), és a dir, un equip informàtic dotat de capacitats multimèdia i adequat per manipular des del sofà de casa nostra.Per acomplir aquesta finalitat primer haurem d'adquirir el maquinari. D'entrada el htpc ensí haurà de ser de mides reduïdes i silenciós, haurà de disposar de sortides vga, dvi i hdmi, i a més, ser capaç de reproduir formats d'alta definició sense cap complicació. El control d'aquest s'haurà de realitzar mitjançant algun dispositiu que no requereixi una superfície plana.A continuació caldrà escollir el programari amb el qual anirà equipat, per tant, haurem de triar alguna distribució de GNU/Linux, instal·lar-hi l'entorn d'escriptori KDE4, i la resta de programari específic com el navegador, correu electrònic, reproducció multimèdia, etc.El productes resultant serà un HTPC, que tal com hem dit, el podrem utilitzar des delssofàs de casa nostra de forma còmode i fàcil.
Resumo:
AIM: Fabry disease is considered primarily as a progressive small vessel disease, with ischaemic degenerative lesions involving the kidneys, brain and heart. Macrovascular involvement in male patients includes an accelerated wall hypertrophy of the radial artery and a thickening of the intima-media of the common carotid artery. The aim of this study is to evaluate the prevalence and severity of carotid artery atherosclerosis in hemizygous and heterozygous patients with Fabry disease, compared with a matched control population. METHODS: The common carotid artery intima-media thickness (IMT) of 53 patients with Fabry disease (24 men, 29 women) was measured by high-definition ultrasonography, and the presence or absence of atherosclerotic plaques reported. Results were compared with those of 120 age-matched healthy individuals (83 men, 37 women). RESULTS: The common carotid artery IMT was increased to the same extent in male and female patients with Fabry disease (706+/-211 microm and 749+/-395 microm, respectively) compared with that of the control population (614+/-113 microm). In the Fabry population, IMT did not correlate with either systolic blood pressure or with renal function (plasma creatinine). In the control population, only systolic blood pressure was positively and significantly correlated with IMT. Atherosclerotic plaques in the common carotid artery were not observed in any patient with Fabry disease, whereas 34% of the control population had carotid artery plaques, as evidenced by focal non-homogeneous intima-media thickening greater than 1.2 mm. CONCLUSION: This study presents evidence of a major increase in common carotid artery IMT, both in hemizygous and heterozygous patients with Fabry disease, in the absence of focal atherosclerotic plaques. These results suggest that the conduit arteries may be protected from atherosclerosis in Fabry disease.
Resumo:
PURPOSE: We investigated the influence of beam modulation on treatment planning by comparing four available stereotactic radiosurgery (SRS) modalities: Gamma-Knife-Perfexion, Novalis-Tx Dynamic-Conformal-Arc (DCA) and Dynamic-Multileaf-Collimation-Intensity-Modulated-radiotherapy (DMLC-IMRT), and Cyberknife. MATERIAL AND METHODS: Patients with arteriovenous malformation (n = 10) or acoustic neuromas (n = 5) were planned with different treatment modalities. Paddick conformity index (CI), dose heterogeneity (DH), gradient index (GI) and beam-on time were used as dosimetric indices. RESULTS: Gamma-Knife-Perfexion can achieve high degree of conformity (CI = 0.77 ± 0.04) with limited low-doses (GI = 2.59 ± 0.10) surrounding the inhomogeneous dose distribution (D(H) = 0.84 ± 0.05) at the cost of treatment time (68.1 min ± 27.5). Novalis-Tx-DCA improved this inhomogeneity (D(H) = 0.30 ± 0.03) and treatment time (16.8 min ± 2.2) at the cost of conformity (CI = 0.66 ± 0.04) and Novalis-TX-DMLC-IMRT improved the DCA CI (CI = 0.68 ± 0.04) and inhomogeneity (D(H) = 0.18 ± 0.05) at the cost of low-doses (GI = 3.94 ± 0.92) and treatment time (21.7 min ± 3.4) (p<0.01). Cyberknife achieved comparable conformity (CI = 0.77 ± 0.06) at the cost of low-doses (GI = 3.48 ± 0.47) surrounding the homogeneous (D(H) = 0.22 ± 0.02) dose distribution and treatment time (28.4min±8.1) (p<0.01). CONCLUSIONS: Gamma-Knife-Perfexion will comply with all SRS constraints (high conformity while minimizing low-dose spread). Multiple focal entries (Gamma-Knife-Perfexion and Cyberknife) will achieve better conformity than High-Definition-MLC of Novalis-Tx at the cost of treatment time. Non-isocentric beams (Cyberknife) or IMRT-beams (Novalis-Tx-DMLC-IMRT) will spread more low-dose than multiple isocenters (Gamma-Knife-Perfexion) or dynamic arcs (Novalis-Tx-DCA). Inverse planning and modulated fluences (Novalis-Tx-DMLC-IMRT and CyberKnife) will deliver the most homogeneous treatment. Furthermore, Linac-based systems (Novalis and Cyberknife) can perform image verification at the time of treatment delivery.
Resumo:
Vehicle operations in underwater environments are often compromised by poor visibility conditions. For instance, the perception range of optical devices is heavily constrained in turbid waters, thus complicating navigation and mapping tasks in environments such as harbors, bays, or rivers. A new generation of high-definition forward-looking sonars providing acoustic imagery at high frame rates has recently emerged as a promising alternative for working under these challenging conditions. However, the characteristics of the sonar data introduce difficulties in image registration, a key step in mosaicing and motion estimation applications. In this work, we propose the use of a Fourier-based registration technique capable of handling the low resolution, noise, and artifacts associated with sonar image formation. When compared to a state-of-the art region-based technique, our approach shows superior performance in the alignment of both consecutive and nonconsecutive views as well as higher robustness in featureless environments. The method is used to compute pose constraints between sonar frames that, integrated inside a global alignment framework, enable the rendering of consistent acoustic mosaics with high detail and increased resolution. An extensive experimental section is reported showing results in relevant field applications, such as ship hull inspection and harbor mapping
Resumo:
Optical coherence tomography (OCT) is a promising medical imaging technique that uses light to capture real-time cross-sectional images from biological tissues in micrometer resolution. Commercially available optical coherence tomography systems are employed in diverse applications, including art conservation and diagnostic medicine, notably in cardiology and ophthalmology. Application of this technology in the brain may enable distinction between white matter and gray matter, and obtainment of detailed images from within the encephalon. We present, herein, the in vivo implementation of OCT imaging in the rat brain striatum. For this, two male 60-day-old rats (Rattus norvegicus, Albinus variation, Wistar) were stereotactically implanted with guide cannulas into the striatum to guide a 2.7-French diameter high-definition OCT imaging catheter (Dragonfly™, St. Jude Medical, USA). Obtained images were compared with corresponding histologically stained sections to collect imaging samples. A brief analysis of OCT technology and its current applications is also reported, as well as intra-cerebral OCT feasibility on brain mapping during neurosurgical procedures.