920 resultados para eye Biometric


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Because dry eye disease is rare in children and its pathogenesis is less well known than in adults, its diagnosis is often overlooked. It can occur in association with a number of congenital, autoimmune, endocrine, and inflammatory disorders, or under certain environmental and nutritional conditions. In some cases, early detection allows the underlying cause of the dry eye to be successfully treated and eliminated. In other cases, the disease may represent a lifelong problem, whose proper management can prevent ulceration and scarring of the ocular surface. Because of the association of pediatric dry eye with other conditions, a multidisciplinary approach to diagnosis and treatment is usually required. The purpose of this review is to enhance physician awareness of dry eye in children, to describe the most frequently associated conditions, and to discuss the diagnostic and therapeutic options available.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective To report the biometric values and ultrasonographic aspects of the normal eye of the Striped owl (Rhinoptynx clamator). Sample population Twenty-seven healthy, free-living, adult Striped owls from the Ecological Park of Tiete Veterinary Ambulatory (Sao Paulo, Brazil). Procedures Both eyes of all owls underwent B-mode ultrasonographic examination and biometry was performed for lens axial length (WL), depth of the anterior (AC) and vitreous (VC) chambers, axial length of the globe (LB) and the pecten oculi (LP) of both eyes, using a 12 MHz probe. The owls were manually restrained without sedation and the eyes were topically anesthetized. Results Biometric and statistical findings were as follows: in the left eye, the means and standard deviations were: LB = 23.76 +/- 0.92 mm, WL = 7.79 +/- 0.27 mm, AC = 4.27 +/- 0.47 mm, VC = 11.36 +/- 0.29 mm and LP = 5.69 +/- 0.50 mm; in the right eye, the values were: LB = 24.25 +/- 0.79 mm, WL = 8.03 +/- 0.40 mm, AC = 4.56 +/- 0.52 mm, VC = 11.40 +/- 0.25 mm, and LP = 5.68 +/- 0.41 mm. No significant differences were found between left and right eyes measurements of LB, WL, AC, VC, and LP dimensions. Conclusions Ocular ultrasound aspects and biometric values of the Striped owl are reported. The study`s results provide means for various ocular measurements. The ultrasound is an easy and safe exam to be performed in the Striped owl`s eyes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Measures of eye activity, such as blink rate and scanning patterns, have been used extensively as psychophysiological indices of mental workload. In a review of measures derived from spontaneous eye activity it is shown that different measures are differentially sensitive to specific aspects of mental workload. A less well-known measure of non-spontaneous eye activity, the blink reflex, is also reviewed. Experiments using discrete punctuate stimuli and continuous tasks analogous to real-world systems show that blink reflexes are modulated by attention and that this modulation reflects modality-specific attentional engagement. Future research should examine the utility of the blink reflex according to the desirable properties of sensitivity, diagnosticity, validity, reliability, ease of use, unobtrusiveness, and operator acceptance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We studied the variation in toxin profiles of purified extracts of 10 individual specimens and two pools of ciguateric Caranx latus. High-performance liquid chromatography/mass spectrometry (HPLC/MS) identified in all individual samples at least seven Caribbean ciguatoxins (C-CTXs) comprising C-CTX-1 and its epimer C-CTX-2 ([M + H](+) m/z 1141.58), and five new C-CTX congeners with pseudo-molecular ions at m/z 1141.58, 1143.60, 1157.57, 1159.58, and 1127.57. In some samples, additional C-CTX isomers were detected with [M + H](+) ions at m/z 1141.58 (two), 1143.60 (one) and 1157.57 (two). The two low-toxic pools contained only four to six ciguatoxins. The comparison in relative proportions of four different mass classes ([M + H](+) at m/z 1141, 1143, 1157 and 1127) showed that the group at m/z 1157 increased (2-20%) with flesh toxicity. More than 80% of group m/z 1141 comprised C-CTX-1, C-CTX-2 and their isomer C-CTX-1 a whose level in this group correlated with fish toxicity. Contrary to low-toxic fishes, high-risk specimens had C-CTX-1 levels

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In response to movements involving a large part of the visual field, the eyes of vertebrates typically show an optokinetic nystagmus, a response in which both eyes are tightly yoked. Using a comparative approach, this study sets out to establish whether fish with independent spontaneous eye movements show independent optokinetic nystagmus in each eye. Two fish with independent spontaneous eye movements, the pipefish Corythoichthyes intestinalis and the sandlance Limnichthyes fasciatus were compared with the butterflyfish Chaetodon rainfordi, which exhibits tightly yoked eye movements. In the butterflyfish a single whole-field stimulus elicits conjugate optokinesis, whereas the sandlance and pipefish show asynchronous optokinetic movements. In a split drum experiment, when both eyes were stimulated in opposite directions with different speeds, both the sandlance and the pipefish compensated independently with each eye. The optokinetic response in the butterflyfish showed some disconjugacy but was generally confused. When one eye was occluded, the seeing eye was capable of driving the occluded eye in both the butterflyfish and the pipefish but not in the sandlance. Monocular occlusion therefore unmasks a link between the two eyes in the pipefish, which is overridden when both eyes receive visual input. The sandlance never showed any correlation between the eyes during optokinesis in all stimulus conditions. This suggests that there are different levels of linkage between the two eyes in the oculomotor system of teleosts, depending on the visual input.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação de Mestrado em Gestão e Conservação da Natureza.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia de Electrónica e Telecomunicações

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The ECG signal has been shown to contain relevant information for human identification. Even though results validate the potential of these signals, data acquisition methods and apparatus explored so far compromise user acceptability, requiring the acquisition of ECG at the chest. In this paper, we propose a finger-based ECG biometric system, that uses signals collected at the fingers, through a minimally intrusive 1-lead ECG setup recurring to Ag/AgCl electrodes without gel as interface with the skin. The collected signal is significantly more noisy than the ECG acquired at the chest, motivating the application of feature extraction and signal processing techniques to the problem. Time domain ECG signal processing is performed, which comprises the usual steps of filtering, peak detection, heartbeat waveform segmentation, and amplitude normalization, plus an additional step of time normalization. Through a simple minimum distance criterion between the test patterns and the enrollment database, results have revealed this to be a promising technique for biometric applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Diane Arbus‘ photographs are mainly about difference. Most of the time she is trying ‗[…] to suppress, or at least reduce, moral and sensory queasiness‘ (Sontag 1977: 40) in order to represent a world where the subject of the photograph is not merely the ‗other‘ but also the I. Her technique does not coax her subjects into natural poses. Instead she encourages them to be strange and awkward. By posing for her, the revelation of the self is identified with what is odd. This paper aims at understanding the geography of difference that, at the same time, is also of resistance, since Diane Arbus reveals what was forcefully hidden by bringing it into light in such a way that it is impossible to ignore. Her photographs display a poetic beauty that is not only of the ‗I‘ but also of the ‗eye‘. The world that is depicted is one in which we are all the same. She ―atomizes‖ reality by separating each element and ‗Instead of showing identity between things which are different […] everybody is shown to look the same.‘ (Sontag 1977: 47). Furthermore, this paper analyses some of Arbus‘ photographs so as to explain this point of view, by trying to argue that between rejecting and reacting against what is standardized she does not forget the geography of the body which is also a geography of the self. While creating a new imagetic topos, where what is trivial becomes divine, she also presents the frailty of others as our own.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The potential of the electrocardiographic (ECG) signal as a biometric trait has been ascertained in the literature over the past decade. The inherent characteristics of the ECG make it an interesting biometric modality, given its universality, intrinsic aliveness detection, continuous availability, and inbuilt hidden nature. These properties enable the development of novel applications, where non-intrusive and continuous authentication are critical factors. Examples include, among others, electronic trading platforms, the gaming industry, and the auto industry, in particular for car sharing programs and fleet management solutions. However, there are still some challenges to overcome in order to make the ECG a widely accepted biometric. In particular, the questions of uniqueness (inter-subject variability) and permanence over time (intra-subject variability) are still largely unanswered. In this paper we focus on the uniqueness question, presenting a preliminary study of our biometric recognition system, testing it on a database encompassing 618 subjects. We also performed tests with subsets of this population. The results reinforce that the ECG is a viable trait for biometrics, having obtained an Equal Error Rate of 9.01% and an Error of Identification of 15.64% for the entire test population.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A 5-year-old girl was bitten in her left eye by a lance-headed viper identified as Bothrops moojeni, measuring 115 cm of length. There was severe facial swelling and left exophthalmus, and enucleation of the eye was necessary. The patient apparently had mild systemic envenoming, but local inflammatory signs and histological evidence of necrosis suggest that both the mechanical trauma and the local action of the venom had a role in the genesis of the eye lesion. It is arguable if the loss of the eye could be prevented even if the antivenom was administered earlier.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mestrado em Engenharia Computação e Instrumentação Médica

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Biometric recognition has recently emerged as part of applications where the privacy of the information is crucial, as in the health care field. This paper presents a biometric recognition system based on the Electrocardiographic signal (ECG). The proposed system is based on a state-of-the-art recognition method which extracts information from the frequency domain. In this paper we propose a new method to increase the spectral resolution of low bandwidth ECG signals due to the limited bandwidth of the acquisition sensor. Preliminary results show that the proposed scheme reveals a higher identification rate and lower equal error rate when compared to previous approaches.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Astringency is an organoleptic property of beverages and food products resulting mainly from the interaction of salivary proteins with dietary polyphenols. It is of great importance to consumers, but the only effective way of measuring it involves trained sensorial panellists, providing subjective and expensive responses. Concurrent chemical evaluations try to screen food astringency, by means of polyphenol and protein precipitation procedures, but these are far from the real human astringency sensation where not all polyphenol–protein interactions lead to the occurrence of precipitate. Here, a novel chemical approach that tries to mimic protein–polyphenol interactions in the mouth is presented to evaluate astringency. A protein, acting as a salivary protein, is attached to a solid support to which the polyphenol binds (just as happens when drinking wine), with subsequent colour alteration that is fully independent from the occurrence of precipitate. Employing this simple concept, Bovine Serum Albumin (BSA) was selected as the model salivary protein and used to cover the surface of silica beads. Tannic Acid (TA), employed as the model polyphenol, was allowed to interact with the BSA on the silica support and its adsorption to the protein was detected by reaction with Fe(III) and subsequent colour development. Quantitative data of TA in the samples were extracted by colorimetric or reflectance studies over the solid materials. The analysis was done by taking a regular picture with a digital camera, opening the image file in common software and extracting the colour coordinates from HSL (Hue, Saturation, Lightness) and RGB (Red, Green, Blue) colour model systems; linear ranges were observed from 10.6 to 106.0 μmol L−1. The latter was based on the Kubelka–Munk response, showing a linear gain with concentrations from 0.3 to 10.5 μmol L−1. In either of these two approaches, semi-quantitative estimation of TA was enabled by direct eye comparison. The correlation between the levels of adsorbed TA and the astringency of beverages was tested by using the assay to check the astringency of wines and comparing these to the response of sensorial panellists. Results of the two methods correlated well. The proposed sensor has significant potential as a robust tool for the quantitative/semi-quantitative evaluation of astringency in wine.