926 resultados para expected university image


Relevância:

40.00% 40.00%

Publicador:

Resumo:

In radiotherapy planning, computed tomography (CT) images are used to quantify the electron density of tissues and provide spatial anatomical information. Treatment planning systems use these data to calculate the expected spatial distribution of absorbed dose in a patient. CT imaging is complicated by the presence of metal implants which cause increased image noise, produce artifacts throughout the image and can exceed the available range of CT number values within the implant, perturbing electron density estimates in the image. Furthermore, current dose calculation algorithms do not accurately model radiation transport at metal-tissue interfaces. Combined, these issues adversely affect the accuracy of dose calculations in the vicinity of metal implants. As the number of patients with orthopedic and dental implants grows, so does the need to deliver safe and effective radiotherapy treatments in the presence of implants. The Medical Physics group at the Cancer Centre of Southeastern Ontario and Queen's University has developed a Cobalt-60 CT system that is relatively insensitive to metal artifacts due to the high energy, nearly monoenergetic Cobalt-60 photon beam. Kilovoltage CT (kVCT) images, including images corrected using a commercial metal artifact reduction tool, were compared to Cobalt-60 CT images throughout the treatment planning process, from initial imaging through to dose calculation. An effective metal artifact reduction algorithm was also implemented for the Cobalt-60 CT system. Electron density maps derived from the same kVCT and Cobalt-60 CT images indicated the impact of image artifacts on estimates of photon attenuation for treatment planning applications. Measurements showed that truncation of CT number data in kVCT images produced significant mischaracterization of the electron density of metals. Dose measurements downstream of metal inserts in a water phantom were compared to dose data calculated using CT images from kVCT and Cobalt-60 systems with and without artifact correction. The superior accuracy of electron density data derived from Cobalt-60 images compared to kVCT images produced calculated dose with far better agreement with measured results. These results indicated that dose calculation errors from metal image artifacts are primarily due to misrepresentation of electron density within metals rather than artifacts surrounding the implants.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The aim of art, as transformer of the individual, has numerous sides which give the human beings a sense of enhancement and growth. It is considered by university the need for our students to take part of this process of social transformation in which they feel the need of helping the community when its members are at risk of social exclusion. Art is considered to be a means, a tool and a purpose for an artis-pedagogue to be used as a guide for the renewal. And the university is also considered as a focus of commitment by means of the development of good practices as well as adopting an open and innovative attitude to any changes aimed at living harmoniously within a more just society.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The purpose of this investigation was to evaluate body image dissatisfaction in relation to low self-esteem due to physical appearance in students of the Faculty of Medicine at the University of Los Andes in Mérida, Venezuela.  It was a non-experimental and correlational study.  The sample included 189 students (27% male and 73% female) with an average age of 19.58 ± 1.57 (men: 19.81 years of age ± 1.74 and women: 20.24 years of age ± 1.76).  Participants were intentionally selected from first-year courses of the Medicine, Nursing and Nutrition programs.  The Body Shape Questionnaire (BSQ) (Cooper and Taylor, 1987) was the instrument used to measure body image dissatisfaction and Graffar’s modified method (Méndez and De Méndez, 1994) was applied to determine the participants’ socioeconomic status.  A descriptive analysis (frequency, percentages, mean) and an inferential analysis (one-way ANOVA) were applied to the data using SPSS (Statistical Package for Social Sciences) version 9.0.  One of the most important findings in this study was the determination of a statistically significant relationship between dissatisfaction and body image and between low self-esteem and gender χ2 (2, N= 189) = 9.686, p=0.008.  Using ANOVA also helped determine that differences in the mean for dissatisfaction and low self-esteem levels with body image and gender are statistically significant, F= 11.236; p=0.008, F=10.23; p=0.002, respectively.  Conclusions: results obtained suggest a relationship between dissatisfaction and low self-esteem due to physical appearance. Consequently, subjects reject their body image because of a distorted or undistorted perception of their physical appearance, which can possibly affect self-esteem.  Moreover, it is observed that the students’ psychological health is more related to their satisfaction with their body-image than to the way their body image is perceived. Consequently, this group of participants must be analyzed regarding their self-esteem due to body image, as an expression in the institutional environment.  It is also important to emphasize that gender may be a risk factor concerning eating disorders.  We believe the foregoing because women showed higher dissatisfaction levels because of their physical appearance being conditioned by a higher dissatisfaction with their perceived body image, which is characterized by an overestimation of the physical dimension of their body image.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Particle-image velocimetry (PIV) was used to visualize the flow within an optically transparent pediatric ventricular assist device (PVAD) under development in our laboratory The device studied is a diaphragm type pulsatile pump with an ejection volume of 30 ml per beating cycle intended for temporary cardiac assistance as a bridge to transplantation or recovery in children. Of particular interest was the identification of flow patterns, including regions of stagnation and/or strong turbulence that often promote thrombus formation and hemolysis, which can degrade the usefulness of such devices. For this purpose, phase-locked PIV measurements were performed in planes parallel to the diaphram that drives the flow in the device. The test fluid was seeded with 10 Am polystyrene spheres, and the motion of these particles was used to determine the instantaneous flow velocity distribution in the illumination plane. These measurements revealed that flow velocities up to 1.0 m/s can occur within the PVAD. Phase-averaged velocity fields revealed the fixed vortices that drive the bulk flow within the device, though significant cycle-to-cycle variability was also quite apparent in the instantaneous velocity distributions, most notably during the filling phase. This cycle-to-cycle variability can generate strong turbulence that may contribute to greater hemolysis. Stagnation regions have also been observed between the input and output branches of the prototype, which can increase the likelihood of thrombus formation. [DOI: 10.1115/1.4001252]

Relevância:

30.00% 30.00%

Publicador:

Resumo:

As seen from Blair Road.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

As seen from Balir Road.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Formal elevation facing University of Queensland entrance roads.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

As seen from informal courtyard; Duhig Tower beyond.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Formal elevation facing University of Queensland entrance roads.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Formal elevation facing University of Queensland entrance roads.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Formal elevation facing University of Queensland entrance roads.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Entry from landscaped amphitheatre area.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Open-ended folded sheet metal gutter.