962 resultados para ex-votos
Resumo:
Neural mechanisms underlying the onset and maintenance of epileptic seizures involve alterations in inhibitory and/or excitatory neurotransmitter pathways. Thus, the prospecting of novel molecules from natural products that target both inhibition and excitation systems has deserved interest in the rational design of new anticonvulsants. We isolated the alkaloids (+)-erythravine and ( +)-11-alpha-hydroxyerythravine from the flowers of Erythrina mulungu and evaluated the action of these compounds against chemically induced seizures in rats. Our results showed that the administration of different doses of (+)-erythravine inhibited seizures evoked by bicuculline, pentylenetetrazole, and kainic acid at maximum of 80, 100, and 100%, respectively, whereas different doses of (+)-11-alpha-hydroxy-erythravine inhibited seizures at a maximum of 100% when induced by bicuculline, NMDA, and kainic acid, and, to a lesser extent, PTZ (60%). The analysis of mean latency to seizure onset of nonprotected animals, for specific doses of alkaloids, showed that (+)-erythravine increased latencies to seizures induced by bicuculline. Although (+)-erythravine exhibited very weak anticonvulsant action against seizures induced by NMDA, this alkaloid increased the latency in this assay. The increase in latency to onset of seizures promoted by (+)-11-alpha-hydroxy-erythravine reached a maximum of threefold in the bicuculline test. All animals were protected against death when treated with different doses of (+)-11-alpha-hydroxy-erythravine in the tests using the four chemical convulsants. Identical results were obtained when using (+)-erythravine in the tests of bicuculline, NMDA, and VIZ, and, to a lesser extent, kainic acid. Therefore, these data validate the anticonvulsant properties of the tested alkaloids, which is of relevance in consideration of the ethnopharmacological/biotechnological potential of E. mulungu. (C) 2010 Elsevier Inc. All rights reserved.
Resumo:
Introduction. Lung tranplantation, a consolidated treatment for end-stage lung disease, utilizes preservation solutions, such as low potassium dextran (LPD), to mitigate ischemia reperfusion injury. We sought the local development of LPD solutions in an attempt to facilitate access and enhance usage. We also sought to evaluate the effectiveness of a locally manufactured LPD solution in a rat model of ex vivo lung perfusion. Methods. We randomized the following groups \?\adult of male Wistar rats (n = 25 each): Perfadex (LPD; Vitro life, Sweden); locally manufactured LPD-glucose (LPDnac) (Farmoterapica, Brazil), and normal saline solution (SAL) with 3 ischemic times (6, 12, and 24 hours). The harvested heart lung blocks were flushed with solution at 4 C. After storage, the blocks were connected to an IL-2 Isolated Perfused Rat or Guinea Pig Lung System (Harvard Apparatus) and reperfused with homologous blood for 60 minutes. Respiratory mechanics, pulmonary artery pressure, perfusate blood gas analysis, and lung weight were measured at 10-minute intervals. Comparisons between groups and among ischemic times were performed using analysis of variance with a 5% level of significance. Results. Lungs preserved for 24 hours were nonviable and therefore excluded from the analysis. Those preserved for 6 hours showed better ventilatory mechanics when compared with 12 hours. The oxygenation capacity was not different between lungs flushed with LPD or LPDnac, regardless of the ischemic time. SAL lungs showed higher PCO(2) values than the other solutions. Lung weight increased over time during perfusion; however, there were no significant differences among the tested solutions (LPD, P = .23; LPDnac, P = .41; SAL, P = .26). We concluded that the LPDnac solution results in gas exchange were comparable to the original LPD (Perfadex); however ventilatory mechanics and edema formation were better with LPD, particularly among lungs undergoing 6 hours of cold ischemia.
Resumo:
To better understand the T-cell hyporesponsiveness of patients with paracoccidioidomycosis, we tested the hypothesis that the T cells were committed to apoptosis. We show here that T cells of patients with paracoccidioidomycosis overexpress caspase 9 and caspase 8 but express low Bcl-2 levels and that interleukin-2 was unable to revert the hyporesponsiveness. These data suggest that the T cells would in vivo be driven to a tolerant state and apoptosis.
Resumo:
Carcinoma ex-pleomorphic adenoma (CXPA) is an aggressive salivary gland malignancy, usually derived from a long-standing or a recurrent benign tumor, the pleomorphic adenoma (PA). In the context of dynamic reciprocity, changes in the composition and structure of extracellular matrix proteins and cell surface receptors have been frequently associated with dysfunctional adhesion and invasive behavior of tumor cells. It is not fully understood if these changes are involved in the conversion of PA to CXPA. In this study, different progression stages of CXPA were investigated regarding the expression of the major extracellular matrix proteins, collagen type I, and of E-cadherin and beta-catenin, the components of adherens junctions. By immunohistochemical analysis, we have demonstrated that direct contact of tumor cells with fibrillar type I collagen, particularly near the invasive front and in invasive areas prevailing small nests of CXPA cells, could be associated with reduced expression of the E-cadherin and beta-catenin adhesion molecules and with invasive behavior of epithelial; but not of CXPA with myoepithelial component. Our results also suggested that this association could depend on the organization of collagen molecules, being prevented by high-order polymeric structures. These findings could implicate the local microenvironment in the transition from the premalignant PA to invasive CXPA.
Resumo:
This study was conducted to analyze the participation of tenascin and fibronectin, components of the extracellular matrix. in different types of carcinoma ex pleomorphic adenoma (CXPA). Seventeen cases of CXPA, classified according to the presence of epithelial and myoepithelial cells and the degree of invasion-intracapsular, minimally, and frankly invasive carcinoma-were immunohistochemically labeled for tenascin and fibronectin. Normal salivary gland included in the specimens showed tenascin only around the excretory duct, and fibronectin slightly expressed all over the stroma of the gland. In reminiscent pleomorphic adenoma, tenascin and fibronectin were observed around tubular structures and in the stroma. Both tenascin and fibronectin were expressed in all the CXPA studied. In areas of in situ carcinoma of the intracapsular type, the expression of these extracellular matrix proteins was enhanced compared with areas of residual pleomorphic adenoma. In intracapsular and minimally invasive types of CXPA, some areas of the tumor border presented tenascin and no fibronectin, pattern that may represent the real invasive front. In frankly invasive CXPA type with only epithelial component, fibronectin was strongly observed in a fibrillar network pattern, and tenascin was only focal. In frankly invasive type with myoepithelial component, tenascin staining was very strong and diffuse. This study showed different patterns of expression of tenascin and fibronectin along the process of tumorigenesis and tumor progression in CXPA, a fact that might play a role in invasion properties of these tumors.
Resumo:
Since the first description of Leishmania (Viannia) shawi, few studies were performed with this parasite. In the present work, the in vivo and ex vivo behavior of L. (Viannia) shawi infection was studied using murine model. Peritoneal macrophages from BALB/c and C57BL/6 mice were infected with promastigotes in the stationary phase of growth; after 24 h, the infection index and nitric oxide (NO) levels in the supernatant of the cultures were analyzed. BALB/c and C57BL/6 mice were infected into the hind footpad, and at each 2 weeks, mice were sacrificed, and the histological changes of the skin inoculation site, parasitism, and humoral immune responses were evaluated during 8 weeks. Ex vivo experiments showed that macrophages of BALB/c presented higher infection index and lesser NO levels than macrophages of C57BL/6. In vivo experiments showed that BALB/c presented higher lesion size than C57BL/6 mice; similarly, the histopathological changes and the parasitism in skin were more exacerbate in BALB/c mice. In draining lymph nodes, the main change was increase of germinative centers, and parasites were detected from 6 weeks pi onwards in both mice strain. IgG was detected in BALB/c mice from 4 weeks, while in C57BL/6, from 6 weeks pi onwards. Taken together, these results indicate that BALB/c showed a classical behavior of susceptibility when compared to C57BL/6 mice.
Resumo:
Introduction. Only about 15% of the potential candidates for lung donation are considered suitable for transplantation. A new method for ex vivo lung perfusion (EVLP) can be used to evaluate and recondition ""marginal,"" nonacceptable lungs. We have herein described an initial experience with ex vivo perfusion of 8 donor lungs deemed nonacceptable. Materials and Methods. After harvesting, the lungs were perfused ex vivo with Steen Solution, an extracellular matrix with high colloid osmotic pressure. A membrane oxygenator connected to the circuit received gas from a mixture of nitrogen and carbon dioxide, maintaining a normal mixed venous blood gas level in the perfusate. The lungs were gradually rewarmed, reperfused, and ventilated for evaluation through analyses of oxygenation capacity, pulmonary vascular resistance (PVR), lung compliance (LC), and biopsy. Results. The arterial oxygen pressure (with inspired oxygen fraction of 100%) increased from a mean of 206 mm Hg in the organ donor at the referring hospital to a mean of 498 mm Hg during the ex vivo evaluation. After 1 hour of EVLP, PVR varied from 440-1454 dynes/sec/cm(5); LC was in the range of 26-90 mL/cmH(2)O. There was no histological deterioration after 10 hours of cold ischemia and 1 hour of EVLP. Conclusions. The ex vivo evaluation model can improve oxygenation capacity of ""marginal"" lungs rejected for transplantation. It has great potential to increase lung donor availability and, possibly, reduce time on the waiting list.
Resumo:
Objective: Natural killer T (NKT) cells are efficiently targeted by HIV and severely reduced in numbers in the circulation of infected individuals. The functional capacity of the remaining NKT cells in HIV-infected individuals is poorly characterized. This study measured NKT cell cytokine production directly ex vivo and compared these responses with both the disease status and NKT subset distribution of individual patients. Methods: NKT cell frequencies, subsets, and ex-vivo effector functions were measured in the peripheral blood mononuclear cells of HIV-infected patients and healthy controls by flow cytometry. We measured cytokines from NKT cells after stimulation with either a-galactosyl ceramide-loaded CD1d dimers (DimerX-alpha GalCer) or phorbol myristate acetate and ionomycin. Results: The frequencies of NKT cells secreting interferon-gamma and tumor necrosis factor-alpha were significantly lower in HIV-infected patients than healthy controls after DimerX-alpha GalCer treatment, but responses were similar after treatment with phorbol myristate acetate and ionomycin. The magnitude of the interferon-gamma response to DimerX-alpha GalCer correlated inversely with the number of years of infection. Both interferon-gamma and tumor necrosis factor-alpha production in response to DimerX-alpha GalCer correlated inversely with CD161 expression. Conclusion: The ex-vivo Th1 responses of circulating NKT cells to CD1d-glycolipid complexes are impaired in HIV-infected patients. NKT cell functions may be progressively lost over time in HIV infection, and CD161 is implicated in the regulation of NKT cell responsiveness. (C) 2009 Wolters Kluwer Health vertical bar Lippincott Williams & Wilkins
Resumo:
Objective: This in situ/ex vivo study assessed the effect of titanium tetrafluoride (TiF4) on permanent human enamel subjected to erosion. Design: Ten volunteers took part in this study performed in two phases. In the first phase (ERO), they wore acrylic palatal appliances containing two enamel blocks, divided into two rows: TiF4 (F) and no-TiF4 (no-F). During the 1st day, the formation of a salivary pellicle was allowed. In the 2nd day, the TiF4 solution was applied on one row (ERO + F), whereas on the other row no treatment was performed (ERO + no-F). From 3rd until 7th day, the blocks were subjected to erosion, 4x per day. In the 2nd phase (no-ERO), the volunteers wore acrylic palatal appliances containing one enamel block, during 2 days, to assess the effect of TiF4 only (no-ERO + F). Enamel alterations were determined using profilometry (wear), microhardness (%SMHC) tests, scanning electron microscope and microprobe analysis. The %SMHC and wear were tested using ANOVA and Tukey`s post hoc tests (p < 0.05). Results: The mean of %SMHC and wear ( mu m) values ( +/- S.D.) were, respectively: ERO + F -73.32 +/- 5.16(A)/2.40 +/- 0.60(a); ERO + no-F -83.49 +/- 4.59B/1.17 +/- 0.48(b) and no-ERO + F -67.92 +/- 6.16(A)/0.21:E 0.09(c). In microscope analysis, the no-F group showed enamel with honeycomb appearance. For F groups, it was observed a surface coating with microcracks. The microprobe analysis revealed the presence of the following elements (%) in groups ERO + F, ERO + no-F and no-ERO + F, respectively: Ca (69.9, 72.5, 66.25); P (25.9, 26.5, 26.06); Ti (3.0, 0, 5.93). Conclusions: The TiF4 was unable to reduce dental erosion. (c) 2007 Elsevier Ltd. All rights reserved.
Resumo:
This in situ/ex vivo study assessed the effect of different concentrations of fluoride in dentifrices on dentin subjected to erosion or to erosion plus abrasion. Ten volunteers took part in this crossover and double-blind study performed in 3 phases (7 days). They wore acrylic palatal appliances containing 4 bovine dentin blocks divided in two rows: erosion and erosion plus abrasion. The blocks were subjected to erosion by immersion ex vivo in a cola drink (60 s, pH 2.6) 4 times daily. During this step, the volunteers brushed their teeth with one of three dentifrices D (5,000 ppm F, NaF, silica); C (1,100 ppm F, NaF, silica) and placebo (22 ppm F, silica). Then, the respective dentifrice slurry (1: 3) was dripped on dentin surfaces. While no further treatment was performed in one row, the other row was brushed using an electric toothbrush for 30 s ex vivo. The appliances were replaced in the mouth and the volunteers rinsed with water. Dentin loss was determined by profilometry and analyzed by 2-way ANOVA/Bonferroni test (alpha = 0.05). Dentin loss after erosive-abrasive wear was significantly greater than after erosion alone. Wear was significantly higher for the placebo than for the D and C dentifrices, which were not significantly different from each other. It can be concluded that the presence of fluoride concentrations around 1,100 ppm in dentifrices is important to reduce dentin wear by erosion and erosion + abrasion, but the protective effect does not increase with fluoride concentration. Copyright (C) 2008 S. Karger AG, Basel.
Resumo:
Individuals with cariogenic diet can also consume erosive beverages. Thus, it seems necessary to investigate a possible caries/erosion interaction. To test in situ/ex vivo a combination of these challenges, 11 subjects wore intraoral appliances containing four enamel blocks randomly assigned. In the first 2-week phase, the appliances were immersed in a cola drink 3 times/day. Two blocks were free of plaque (erosion only: EO) and two blocks were covered with plaque (erosion + plaque: EP). In the second 2-week phase, four new blocks were all covered with plaque and subjected to a sucrose solution 8 times/day. Among the four new blocks, two were also subjected to the cola drink 3 times/day (erosion + caries: EC) while the other two were not (caries only: CO). Thus, in EO, the specimens were fixed at the intraoral appliance level. In EP, EC and CO they were fixed 1.0 mm under the appliance level and covered with plastic meshes for dental plaque accumulation. Changes in wear and hardness were measured. Data were tested using ANOVA and Tukey`s test (p < 0.05). Mean values of wear (mu m) and change in hardness (kp/mm(2)) were: EO 4.82/310; EP 0.14/48; EC 0.34/245; CO 0.42/309. With respect to surface softening, EP and EC differed significantly from each other and from EO and CO, which did not differ significantly. EO presented significantly higher wear than the other groups. The data suggest that the presence of dental plaque can decrease the acid attack of an erosive drink and the association of erosive and cariogenic challenges showed less enamel alterations when compared to erosive or cariogenic challenges only. Copyright (C) 2008 S. Karger AG, Basel
Resumo:
Objective: As resin-modified glass-ionomer cement (RMGIC) is an adhesive material, its association to dentin bonding agents (DBAs) was previously proposed. This study investigated the adjunctive behavior of an RMGIC with etch-and-rinse bonding systems under in situ/ex vivo cariogenic challenge. Method and Materials: Bovine enamel blocks (3 3 2 mm) were randomly assigned to group VP, Vitremer + its own primer (3M ESPE); group VSB, Vitremer + Single Bond (3M ESPE); and group VPB, Vitremer + Prime & Bond 2.1 (Dentsply). Two blocks of each group were randomly placed in an acrylic palatal appliance, so each appliance included six blocks. Volunteers (n = 10) wore these appliances according to given instructions to promote a sucrose challenge eight times/day for 15 days. After this period, the blocks were removed from the devices and cleaned, and demineralization was assessed through longitudinal microhardness analysis (Knoop indenter, 25 g/5 s). Data were submitted to three-way ANOVA and Tukey test (P < .05). Results: No treatment was able to completely avoid demineralization. All materials showed a statistically significant difference in mineral loss when the microhardness on the outer enamel was compared with deeper regions (P < .05). Conclusion: Association of the tested RMGICs with etch-and-rinse DBAs did not seem to be more beneficial against caries than the conventional treatment with RMGIC. (Quintessence Int 2010; 41: e192-e199)
Resumo:
Objective. The aim of this study was to compare GPX instruments and hand files for gutta-percha removal. Study design. Fifty maxillary central incisors with a single straight canal were instrumented and filled. The teeth were divided into 5 groups of 10 specimens each, according to the gutta-percha removal techniques: group 1: GPX (21-mm-long teeth); group 2: GPX and xylol as solvent (21-mm-long teeth); group 3: GPX (25-mm-long teeth); group 4: GPX and xylol as solvent (25-mm-long teeth); and group 5: hand files and xylol as solvent. The amount of time for gutta-percha removal and the number of fractured instruments were evaluated. Radiographs were taken, and the teeth were grooved longitudinally and split. The area of residual debris was measured using Sigma Scan software. Results. The time for filling material removal was significantly shorter when GPX was used (P < .05). Overall, hand files and solvent produced fewer remnants of filling materials (P < .05). In the GPX 25 mm-long teeth group, the filling material was not removed in the apical third. Conclusions. Under the experimental conditions, the GPX instruments proved to be faster than hand instruments in removing root filling materials; however, hand instruments left a smaller amount of residual filling materials on the canal walls. The GPX instruments did not pull the gutta-percha beyond its tip. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2010; 110: 675-680)
Resumo:
Objective. The aim of this study was to evaluate the precision of working length determination of 3 electronic apex locators (EALs): Root ZX, RomiApex D-30, and Ipex at 0.0 mm, at the apical foramen (AF), and at 1.0 mm short of the AF. Methodology. Thirty-eight mandibular premolars had their real lengths previously determined. Electronic measurements were determined at 1.0 mm, followed by measurements at 0.0 mm, performed in triplicate. Results. Precision of devices at 1.0 mm and 0.0 mm were: 94.7% and 97.4%, respectively (Root ZX); 78.9% and 97.4% (RomiApex D-30); and 76.3% and 97.4% (Ipex). Although no statistical differences were observed between the EALs at 0.0, at 1.0 mm Root ZX performed significantly better than the others. Conclusion. The EALs had acceptable precision when measuring the working length at the AF. However, when used at levels short of the AF, only Root ZX did not suffer a significant negative effect on precision. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2010;110:e57-e61)