932 resultados para dose


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives This randomised, controlled trial compared the effectiveness of 0.12% chlorhexidine (CHX) gel and 304% fluoride toothpaste to prevent early childhood caries (ECC) in a birth cohort by 24 months. Methods The participants were randomised to receive either (i) twice daily toothbrushing with toothpaste and once daily 0.12% CHX gel (n = 110) or (ii) twice daily toothbrushing with toothpaste only (study controls) (n = 89). The primary outcome measured was caries incidence and the secondary outcome was percentage of children with mutans streptococci (MS). All mothers were contacted by telephone at 6, 12, and 18 months. At 24 months, all children were examined at a community dental clinic. Results At 24 months, the caries prevalence was 5% (3/61) in the CHX and 7% (4/58) in the controls (P = 0.7). There were no differences in percentages of MS-positive children between the CHX and control groups (54%vs 53%). Only 20% applied the CHX gel once daily and 80% less than once daily. Conclusions Toothbrushing using 304% fluoride toothpaste with or without the application of chlorhexidine gel (0.12%) reduces ECC from 23% found in the general community to 5–7%. The lack of effect with chlorhexidine is likely to be due to low compliance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Crash statistics that include the blood alcohol concentration (BAC) of vehicle operators reveal that crash involved motorcyclists are over represented at low BACs (e.g., ≤0.05%). This riding simulator study compared riding performance and hazard response under three low dose alcohol conditions (sober, 0.02% BAC, 0.05% BAC). Forty participants (20 novice, 20 experienced) completed simulated rides in urban and rural scenarios while responding to a safety-critical peripheral detection task (PDT). Results showed a significant increase in the standard deviation of lateral position in the urban scenario and PDT reaction time in the rural scenario under 0.05% BAC compared with zero alcohol. Participants were most likely to collide with an unexpected pedestrian in the urban scenario at 0.02% BAC, with novice participants at a greater relative risk than experienced riders. Novices chose to ride faster than experienced participants in the rural scenario regardless of BAC. Not all results were significant, emphasising the complex situation of the effects of low dose BAC on riding performance, which needs further research. The results of this simulator study provide some support for a legal BAC for motorcyclists below 0.05%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective Bronchiolitis, one of the most common reasons for hospitalisation in young children, is particularly problematic in Indigenous children. Macrolides may be beneficial in settings where children have high rates of nasopharyngeal bacterial carriage and frequent prolonged illness. The aim of our double-blind placebo-controlled randomised trial was to determine if a large single dose of azithromycin (compared to placebo) reduced length of stay (LOS), duration of oxygen (O2) and respiratory readmissions within 6 months of children hospitalised with bronchiolitis. We also determined the effect of azithromycin on nasopharyngeal microbiology. Methods Children aged ≤18 months were randomised to receive a single large dose (30 mg/kg) of either azithromycin or placebo within 24 hrs of hospitalisation. Nasopharyngeal swabs were collected at baseline and 48hrs later. Primary endpoints (LOS, O2) were monitored every 12 hrs. Hospitalised respiratory readmissions 6-months post discharge was collected. Results 97 children were randomised (n = 50 azithromycin, n = 47 placebo). Median LOS was similar in both groups; azithromycin = 54 hours, placebo = 58 hours (difference between groups of 4 hours 95%CI -8, 13, p = 0.6). O2 requirement was not significantly different between groups; Azithromycin = 35 hrs; placebo = 42 hrs (difference 7 hours, 95%CI -9, 13, p = 0.7). Number of children re-hospitalised was similar 10 per group (OR = 0.9, 95%CI 0.3, 2, p = 0.8). At least one virus was detected in 74% of children. The azithromycin group had reduced nasopharyngeal bacterial carriage (p = 0.01) but no difference in viral detection at 48 hours. Conclusion Although a single dose of azithromycin reduces carriage of bacteria, it is unlikely to be beneficial in reducing LOS, duration of O2 requirement or readmissions in children hospitalised with bronchiolitis. It remains uncertain if an earlier and/or longer duration of azithromycin improves clinical and microbiological outcomes for children.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Hydroxyurea (HU), an inhibitor of ribonucleotide reductase, may potentiate the activity of 5-fluorouracil (5-FU) and folinic acid (FA) by reducing the deoxyribonucleotide pool available for DNA synthesis and repair. However as HU may inhibit the formation of 5-fluoro-2-deoxyuridine-5- monophosphate (FdUMP), one of the principal active metabolites of 5-FU, the scheduling of HU may be critical. In vitro experiments suggest that administration of HU following 5-FU, maintaining the concentration in the region of I mM for six or more hours, significantly enhances the efficacy of 5-FU. Patients and methods: 5-FU/FA was given as follows: days 1 and 2 - FA 250 mg/m 2 (max. 350 mg) over two hours followed by 5-FU 400 mg/m 2 by intravenous bolus (ivb) over 15 minutes and subsequently 5-FU 400 mg/m 2 infusion (ivi) over 22 hours. HU was administered on day 3 immediately after the 5-FU with 3 g ivb over 15 minutes followed by 12 g ivi over 12 hours. Results: Thirty patients were entered into the study. Median survival was nine months (range 1-51 + months). There were eight partial responses (28%, 95% CI: 13%-47%). The median duration of response was 6.5 (range 4-9 months). Grade 3-4 toxicities included neutropenia (grade 3 in eight patients and grade 4 in five), anaemia (grade 3 in one patient) and diarrhoea (grade 3 in two patients). Neutropenia was associated with pyrexia in two patients. Phlebitis at the infusion site occurred in five patients. The treatment was complicated by pulmonary embolism in one patient and deep venous thrombosis in another. Conclusion: HU administered in this schedule is well tolerated. Based on these results and those of other phase II studies, a randomised phase III study of 5-FU, FA and HU versus 5-FU and FA using the standard de Gramont schedule is recommended.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aims of this phase I study were to establish the maximum tolerated dose, safety profile and activity of liposomal daunorubicin, DaunoXome (NeXstar Pharmaceuticals), in the treatment of metastatic breast cancer. DaunoXome was administered intravenously over 2 h in 21 day cycles and doses were increased from 80 to 100, 120 and 150 mg m 2. Sixteen patients were enrolled. A total of 70 cycles of DaunoXome were administered. The maximum tolerated dose was 120 mg m 2, the dose-limiting toxicity being prolonged grade 4 neutropenia or neutropenic pyrexia necessitating dose reductions at 120 and 150 mg m 2. Asymptomatic cardiotoxicity was observed in three patients: grade 1 in one treated with a cumulative dose of 800 mg m 2 and grade 2 in two, one who received a cumulative dose of 960 mg m 2 and the other a cumulative dose of 600 mg m 2 with a previous neoadjuvant doxorubicin chemotherapy of 300 mg m 2. Tumour response was evaluable in 15 patients, of whom two had objective responses, six had stable disease and seven had progressive disease. In conclusion, DaunoXome is associated with mild, manageable toxicities and has anti-tumour activity in metastatic breast cancer. The findings support further phase II evaluation of DaunoXome alone and in combination with other standard non-anthracycline cytotoxic or novel targeted agents. Although the dose-limiting toxicity for DaunoXome was febrile neutropenia at 120 mg m 2, we would recommend this dose for further evaluation, as the febrile neutropenia occurred after four or more cycles in three of the four episodes seen, was short lived and uncomplicated. © 2002 Cancer Research UK.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this phase I/II dose escalating study was to establish the maximum tolerated dose (MTD) of gemcitabine and paclitaxel given in combination in non-small cell lung cancer (NSCLC). 12 patients with stage IIIB and IV NSCLC received paclitaxel administered intravenously over 1 h followed by gemcitabine given over 30 min on days 1, 8 and 15 every 28 days. Pneumonitis was the principal side-effect observed with 4 patients affected. Of these, 1 experienced grade 3 toxicity after one cycle of treatment and the others had grade 2 toxicity. All 4 cases responded to prednisolone. No other significant toxicities were observed. Of the 8 evaluable patients, 3 had a partial response and 2 had minor responses. The study was discontinued due to this dose-limiting toxicity. The combination of paclitaxel and gemcitabine shows promising antitumour activity in NSCLC, however, this treatment schedule may predispose to pneumonitis. (C) 2000 Elsevier Science Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To obtain accurate Monte Carlo simulations of small radiation fields, it is important model the initial source parameters (electron energy and spot size) accurately. However recent studies have shown that small field dosimetry correction factors are insensitive to these parameters. The aim of this work is to extend this concept to test if these parameters affect dose perturbations in general, which is important for detector design and calculating perturbation correction factors. The EGSnrc C++ user code cavity was used for all simulations. Varying amounts of air between 0 and 2 mm were deliberately introduced upstream to a diode and the dose perturbation caused by the air was quantified. These simulations were then repeated using a range of initial electron energies (5.5 to 7.0 MeV) and electron spot sizes (0.7 to 2.2 FWHM). The resultant dose perturbations were large. For example 2 mm of air caused a dose reduction of up to 31% when simulated with a 6 mm field size. However these values did not vary by more than 2 % when simulated across the full range of source parameters tested. If a detector is modified by the introduction of air, one can be confident that the response of the detector will be the same across all similar linear accelerators and the Monte Carlo modelling of each machine is not required.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dose-finding trials are a form of clinical data collection process in which the primary objective is to estimate an optimum dose of an investigational new drug when given to a patient. This thesis develops and explores three novel dose-finding design methodologies. All design methodologies presented in this thesis are pragmatic. They use statistical models, incorporate clinicians' prior knowledge efficiently, and prematurely stop a trial for safety or futility reasons. Designing actual dose-finding trials using these methodologies will minimize practical difficulties, improve efficiency of dose estimation, be flexible to stop early and reduce possible patient discomfort or harm.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two sources of uncertainty in the X ray computed tomography imaging of polymer gel dosimeters are investigated in the paper.The first cause is a change in postirradiation density, which is proportional to the computed tomography signal and is associated with a volume change. The second cause of uncertainty is reconstruction noise.A simple technique that increases the residual signal to noise ratio by almost two orders of magnitude is examined.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The transplantation of autologous bone graft as a treatment for large bone defects has the limitation of harvesting co-morbidity and limited availability. This drives the orthopaedic research community to develop bone graft substitutes. Routinely, supra-physiological doses of bone morphogenetic proteins (BMPs) are applied perpetuating concerns over undesired side effects and cost of BMPs. We therefore aimed to design a composite scaffold that allows maintenance of protein bioactivity and enhances growth factor retention at the implantation site. Critical-sized defects in sheep tibiae were treated with the autograft and with two dosages of rhBMP-7, 3.5 mg and 1.75 mg, embedded in a slowly degradable medical grade poly(ε-caprolactone) (PCL) scaffold with β-tricalcium phosphate microparticles (mPCL-TCP). Specimens were characterised by biomechanical testing, microcomputed tomography and histology. Bridging was observed within 3 months for the autograft and both rhBMP-7 treatments. No significant difference was observed between the low and high rhBMP-7 dosages or between any of the rhBMP-7 groups and autograft implantation. Scaffolds alone did not induce comparable levels of bone formation compared to the autograft and rhBMP-7 groups. In summary, the mPCL-TCP scaffold with the lower rhBMP-7 dose led to equivalent results to autograft transplantation or the high BMP dosage. Our data suggest a promising clinical future for BMP application in scaffold-based bone tissue engineering, lowering and optimising the amount of required BMP.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dose-finding designs estimate the dose level of a drug based on observed adverse events. Relatedness of the adverse event to the drug has been generally ignored in all proposed design methodologies. These designs assume that the adverse events observed during a trial are definitely related to the drug, which can lead to flawed dose-level estimation. We incorporate adverse event relatedness into the so-called continual reassessment method. Adverse events that have ‘doubtful’ or ‘possible’ relationships to the drug are modelled using a two-parameter logistic model with an additive probability mass. Adverse events ‘probably’ or ‘definitely’ related to the drug are modelled using a cumulative logistic model. To search for the maximum tolerated dose, we use the maximum estimated toxicity probability of these two adverse event relatedness categories. We conduct a simulation study that illustrates the characteristics of the design under various scenarios. This article demonstrates that adverse event relatedness is important for improved dose estimation. It opens up further research pathways into continual reassessment design methodologies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction Given the known challenges of obtaining accurate measurements of small radiation fields, and the increasing use of small field segments in IMRT beams, this study examined the possible effects of referencing inaccurate field output factors in the planning of IMRT treatments. Methods This study used the Brainlab iPlan treatment planning system to devise IMRT treatment plans for delivery using the Brainlab m3 microMLC (Brainlab, Feldkirchen, Germany). Four pairs of sample IMRT treatments were planned using volumes, beams and prescriptions that were based on a set of test plans described in AAPM TG 119’s recommendations for the commissioning of IMRT treatment planning systems [1]: • C1, a set of three 4 cm volumes with different prescription doses, was modified to reduce the size of the PTV to 2 cm across and to include an OAR dose constraint for one of the other volumes. • C2, a prostate treatment, was planned as described by the TG 119 report [1]. • C3, a head-and-neck treatment with a PTV larger than 10 cm across, was excluded from the study. • C4, an 8 cm long C-shaped PTV surrounding a cylindrical OAR, was planned as described in the TG 119 report [1] and then replanned with the length of the PTV reduced to 4 cm. Both plans in each pair used the same beam angles, collimator angles, dose reference points, prescriptions and constraints. However, one of each pair of plans had its beam modulation optimisation and dose calculation completed with reference to existing iPlan beam data and the other had its beam modulation optimisation and dose calculation completed with reference to revised beam data. The beam data revisions consisted of increasing the field output factor for a 0.6 9 0.6 cm2 field by 17 % and increasing the field output factor for a 1.2 9 1.2 cm2 field by 3 %. Results The use of different beam data resulted in different optimisation results with different microMLC apertures and segment weightings between the two plans for each treatment, which led to large differences (up to 30 % with an average of 5 %) between reference point doses in each pair of plans. These point dose differences are more indicative of the modulation of the plans than of any clinically relevant changes to the overall PTV or OAR doses. By contrast, the maximum, minimum and mean doses to the PTVs and OARs were smaller (less than 1 %, for all beams in three out of four pairs of treatment plans) but are more clinically important. Of the four test cases, only the shortened (4 cm) version of TG 119’s C4 plan showed substantial differences between the overall doses calculated in the volumes of interest using the different sets of beam data and thereby suggested that treatment doses could be affected by changes to small field output factors. An analysis of the complexity of this pair of plans, using Crowe et al.’s TADA code [2], indicated that iPlan’s optimiser had produced IMRT segments comprised of larger numbers of small microMLC leaf separations than in the other three test cases. Conclusion: The use of altered small field output factors can result in substantially altered doses when large numbers of small leaf apertures are used to modulate the beams, even when treating relatively large volumes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The reporting and auditing of patient dose is an important component of radiotherapy quality assurance. The manual extraction of dose-volume metrics is time consuming and undesirable when auditing the dosimetric quality of a large cohort of patient plans. A dose assessment application was written to overcome this, allowing the calculation of various dose-volume metrics for large numbers of plans exported from treatment planning systems. This application expanded on the DICOM-handling functionality of the MCDTK software suite. The software extracts dose values in the volume of interest by using a ray casting point-in-polygon algorithm, where the polygons have been defined by the contours in the RTSTRUCT file...

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective Recently, Taylor et al. reported that use of the BrainLAB m3 microMLC, for stereotactic radiosurgery, results in a decreased out-of-field dose in the direction of leaf-motion compared to the outof- field dose measured in the direction orthogonal to leaf-motion [1]. It was recommended that, where possible, patients should be treated with their superior–inferior axes aligned with the microMLCs leafmotion direction, to minimise out-of-field doses [1]. This study aimed, therefore, to examine the causes of this asymmetry in outof- field dose and, in particular, to establish that a similar recommendation need not be made for radiotherapy treatments delivered by linear accelerators without external micro-collimation systems. Methods Monte Carlo simulations were used to study out-of-field dose from different linear accelerators (the Varian Clinacs 21iX and 600C and the Elekta Precise) with and without internal MLCs and external microMLCs [2]. Results Simulation results for the Varian Clinac 600C linear accelerator with BrainLAB m3 microMLC confirm Taylor et als [1] published experimental data. The out-of-field dose in the leaf motion direction is deposited by lower energy (more obliquely scattered) photons than the out-of-field dose in the orthogonal direction. Linear accelerators without microMLCs produce no asymmetry in out-offield dose. Conclusions The asymmetry in out-of-field dose previously measured by Taylor et al. [1] results from the shielding characteristics of the BrainLAB m3 microMLC device and is not produced by the linear accelerator to which it is attached.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cancers of the brain and central nervous system account for 1.6% of new cancers and 1.8% of cancer deaths globally. The highest rates of all developed nations are observed in Australia and New Zealand. There are known complexities associated with dose measurement of very small radiation fields. Here, 3D dosimetric verification of treatments for small intracranial tumours using gel dosimetry was investigated.