908 resultados para dialysis dose


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Interdialytic weight gain (IDWG) can be reduced by lowering the dialysate sodium concentration ([Na]) in haemodialysis patients. It has been assumed that this is because thirst is reduced, although this has been difficult to prove. We compared thirst patterns in stable haemodialysis patients with high and low IDWG using a novel technique and compared the effect of low sodium dialysis (LSD) with normal sodium dialysis (NSD). Methods Eight patients with initial high IDWG and seven with low IDWG completed hourly visual analogue ratings of thirst using a modified palmtop computer during the dialysis day and the interdialytic day. The dialysate [Na] was progressively reduced by up to 5 mmol/l over five treatments. Dialysis continued at the lowest attained [Na] for 2 weeks and the measurements were repeated. The dialysate [Na] then returned to baseline and the process was repeated. Results Baseline interdialytic day mean thirst was higher than the dialysis day mean for the high IDWG group (49.9±14.0 vs 36.2±16.6) and higher than the low weight gain group (49.9±14.0 vs 34.1±14.6). This trend persisted on LSD, but there was a pronounced increase in post-dialysis thirst scores for both groups (high IDWG: 46±13 vs 30±21; low IDWG: 48±24 vs 33±18). The high IDWG group demonstrated lower IDWG during LSD than NSD (2.23±0.98 vs 2.86±0.38 kg; P<0.05). Conclusions Our results indicate that patients with high IDWG experience more intense feelings of thirst on the interdialytic day. LSD reduces their IDWG, but paradoxically increases thirst in the immediate post-dialysis period.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Some dialysis patients fail to comply with their fluid restriction causing problems due to volume overload. These patients sometimes blame excessive thirst. There has been little work in this area and no work documenting polydipsia among peritoneal dialysis (PD) patients. Methods We measured motivation to drink and fluid consumption in 46 haemodialysis patients (HD), 39 PD patients and 42 healthy controls (HC) using a modified palmtop computer to collect visual analogue scores at hourly intervals. Results Mean thirst scores were markedly depressed on the dialysis day (day 1) for HD (P<0.0001). The profile for day 2 was similar to that of HC. PD generated consistently higher scores than HD day 1 and HC (P = 0.01 vs. HC and P<0.0001 vs HD day 1). Reported mean daily water consumption was similar for HD and PD with both significantly less than HC (P<0.001 for both). However, measured fluid losses were similar for PD and HC whilst HD were lower (P<0.001 for both) suggesting that the PD group may have underestimated their fluid intake. Conclusion Our results indicate that HD causes a protracted period of reduced thirst but that the population's thirst perception is similar to HC on the interdialytic day despite a reduced fluid intake. In contrast, the PD group recorded high thirst scores throughout the day and were apparently less compliant with their fluid restriction. This is potentially important because the volume status of PD patients influences their survival.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background We have used serial visual analogue scores to demonstrate disturbances of the appetite profile in dialysis patients. This is potentially important as dialysis patients are prone to malnutrition yet have a lower nutrient intake than controls. Appetite disturbance may be influenced by accumulation of appetite inhibitors such as leptin and cholecystokinin (CCK) in dialysis patients. Methods Fasting blood samples were drawn from 43 controls, 50 haemodialysis (HD) and 39 peritoneal dialysis (PD) patients to measure leptin and CCK. Hunger and fullness scores were derived from profiles compiled using hourly visual analogue scores. Nutrient intake was derived from 3 day dietary records. Results Fasting CCK was elevated for PD (6.73 ± 4.42 ng/l vs control 4.99 ± 2.23 ng/l, P < 0.05; vs HD 4.43 ± 2.15 ng/l, P < 0.01). Fasting CCK correlated with the variability of the hunger (r = 0.426, P = 0.01) and fullness (r = 0.52, P = 0.002) scores for PD. There was a notable relationship with the increase in fullness after lunch for PD (r = 0.455, P = 0.006). When well nourished PD patients were compared with their malnourished counterparts, CCK was higher in the malnourished group (P = 0.004). Leptin levels were higher for the dialysis patients than controls (HD and PD, P < 0.001) with pronounced hyperleptinaemia evident in some PD patients. Control leptin levels demonstrated correlation with fullness scores (e.g. peak fullness, r = 0.45, P = 0.007) but the dialysis patients did not. PD nutrient intake (energy and protein intake, r = -0.56, P < 0.0001) demonstrated significant negative correlation with leptin. Conclusion Increased CCK levels appear to influence fullness and hunger perception in PD patients and thus may contribute to malnutrition. Leptin does not appear to affect perceived appetite in dialysis patients but it may influence nutrient intake in PD patients via central feeding centres.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE Malnutrition is common among peritoneal dialysis (PD) patients. Reduced nutrient intake contributes to this. It has long been assumed that this reflects disturbed appetite. We set out to define the appetite profiles of a group of PD patients using a novel technique. DESIGN Prospective, cross-sectional comparison of PD patients versus controls. SETTING Teaching hospital dialysis unit. PATIENTS 39 PD patients and 42 healthy controls. INTERVENTION Visual analog ratings were recorded at hourly intervals to generate daily profiles for hunger and fullness. Summary statistics were generated to compare the groups. Food intake was measured using 3-day dietary records. MAIN OUTCOME MEASURES Hunger and fullness profiles. Derived hunger and fullness scores. RESULTS Controls demonstrated peaks of hunger before mealtimes, with fullness scores peaking after meals. The PD profiles had much reduced premeal hunger peaks. A postmeal reduction in hunger was evident, but the rest of the trace was flat. The PD fullness profile was also flatter than in the controls. Mean scores were similar despite the marked discrepancy in the profiles. The PD group had lower peak hunger and less diurnal variability in their hunger scores. They also demonstrated much less change in fullness rating around mealtimes, while the mean and peak fullness scores were little different. The reported nutrient intake was significantly lower for PD. CONCLUSION The data suggest that PD patients normalize their mean appetite perception at a lower level of nutrient intake than controls, suggesting that patient-reported appetite may be misleading in clinical practice. There is a loss of the usual daily variation for the PD group, which may contribute to their reduced food intake. The technique described here could be used to assess the impact of interventions upon the abnormal PD appetite profile.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The high levels of end-stage renal disease among Indigenous Australians, particularly in remote areas of the country, are a serious public health concern. The magnitude of the problem is reflected in figures from the Australian and New Zealand Transplant and Dialysis Registry that show that Indigenous Australians experience end-stage renal disease at a rate almost 9–10 times higher than other non-Indigenous Australians. A majority of Indigenous Australians have to relocate to receive appropriate renal dialysis treatment. In some Australian states, renal treatment is based on self-care dialysis which allows those Indigenous Australians to be treated back in their community. Evidence clearly shows that reuniting renal patients with community and family improves overall health and well-being for those Indigenous Australians. With the appropriate resources, training, and support, self-care management of renal dialysis treatment is an effective way for Indigenous people with end-stage renal failure to be treated at home. In this context, the study was used to gain insight and further understanding of the impact that end-stage renal disease and renal dialysis treatment has had on the lives of Indigenous community members. The study findings are from 14 individually interviewed people from South East Queensland. Data from the interviews were analysed using a combination of thematic and content analysis. The study methodology was based on qualitative data principles where the Indigenous community members were able to share their experiences and journeys living with end-stage renal disease. Many of the experiences and understanding closely relate to the renal disease pattern and the treatment with other outside influences, such as social, cultural, and environmental influences, all having an equal impact. Each community member’s experience with end-stage renal disease is unique; some manage with family and medical support, while others try to manage independently. From the study, community members who managed their renal dialysis treatment independently were much more aware of their renal health status. The study provides recommendations towards a model of care to improve the health and well-being is based on self-care and self-determination principles.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The iPlan treatment planning sys-tem uses a pencil beam algorithm, with density cor-rections, to predict the doses delivered by very small (stereotactic) radiotherapy fields. This study tests the accuracy of dose predictions made by iPlan, for small-field treatments delivered to a planar solid wa-ter phantom and to heterogeneous human tissue using the BrainLAB m3 micro-multileaf collimator.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Knowledge of the accuracy of dose calculations in intensity-modulated radiotherapy of the head and neck is essential for clinical confidence in these highly conformal treatments. High dose gradients are frequently placed very close to critical structures, such as the spinal cord, and good coverage of complex shaped nodal target volumes is important for long term-local control. A phantom study is presented comparing the performance of standard clinical pencil-beam and collapsed-cone dose algorithms to Monte Carlo calculation and three-dimensional gel dosimetry measurement. All calculations and measurements are normalized to the median dose in the primary planning target volume, making this a purely relative study. The phantom simulates tissue, air and bone for a typical neck section and is treated using an inverse-planned 5-field IMRT treatment, similar in character to clinically used class solutions. Results indicate that the pencil-beam algorithm fails to correctly model the relative dose distribution surrounding the air cavity, leading to an overestimate of the target coverage. The collapsed-cone and Monte Carlo results are very similar, indicating that the clinical collapsed-cone algorithm is perfectly sufficient for routine clinical use. The gel measurement shows generally good agreement with the collapsed-cone and Monte Carlo calculated dose, particularly in the spinal cord dose and nodal target coverage, thus giving greater confidence in the use of this class solution.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Monitoring and enhancing patient compliance with peritoneal dialysis (PD) is a recurring and problematic theme in the renal literature. A growing body of literature also argues that a failure to understand the patient's perspective of compliance may be contributing to these problems. The aim of this study was to understand the concept of compliance with PD from the patient's perspective. Using the case study approach recommended by Stake (1995), five patients on PD consented to in-depth interviews that explored the meaning of compliance in the context of PD treatment and lifestyle regimens recommended by health professionals. Participants also discussed factors that influenced their choices to follow, disregard, or refine these regimens. Results indicate that health professionals acting in alignment with individual patient needs and wishes, and demonstrating an awareness of the constraints under which patients operate and the strengths they bring to their treatment, may be the most significant issues to consider with respect to definitions of PD compliance and the development of related compliance interventions. Aspects of compliance that promoted relative normality were also important to the participants in this study and tended to result in greater concordance with health professionals' advice.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Poor patient compliance with peritoneal dialysis (PD) has significant adverse effects on morbidity and mortality rates in individuals with chronic kidney disease (CKD). It also adds to the resource burdens of healthcare services and providers. This paper explores the notion of PD compliance in patients with CKD with reference to the relevant published literature. The analysis of the literature reveals that ‘PD compliance’ is a complex and challenging construct for both patients and health professionals. There is no universal definition of compliance that is widely adopted in practice and research, and therefore a lack of consensus on how to determine ‘compliant’ patient outcomes. There are also multiple and interconnected determinants of PD compliance that are context-bound, which healthcare professionals must be aware of, and which makes producing consensus of measuring PD compliance difficult. The complexity of the interventions required to produce even a modest improvement in PD compliance, which are described in this paper, are significant. Compliance with PD and other treatments for CKD is a multidimensional, context-bound concept, that to date has tended to efface the role and needs of the renal patient. We conclude the paper with the implications for contemporary practice.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study uses dosimetry film measurements and Monte Carlo simulations to investigate the accuracy of type-a (pencil-beam) dose calculations for predicting the radiation doses delivered during stereotactic radiotherapy treatments of the brain. It is shown that when evaluating doses in a water phantom, the type-a algorithm provides dose predictions which are accurate to within clinically relevant criteria, gamma(3%,3mm), but these predictions are nonetheless subtly different from the results of evaluating doses from the same fields using radiochromic film and Monte Carlo simulations. An analysis of a clinical meningioma treatment suggests that when predicting stereotactic radiotherapy doses to the brain, the inaccuracies of the type-a algorithm can be exacerbated by inadequate evaluation of the effects of nearby bone or air, resulting in dose differences of up to 10% for individual fields. The results of this study indicate the possible advantage of using Monte Carlo calculations, as well as measurements with high-spatial resolution media, to verify type-a predictions of dose delivered in cranial treatments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We consider the problem of how to efficiently and safely design dose finding studies. Both current and novel utility functions are explored using Bayesian adaptive design methodology for the estimation of a maximum tolerated dose (MTD). In particular, we explore widely adopted approaches such as the continual reassessment method and minimizing the variance of the estimate of an MTD. New utility functions are constructed in the Bayesian framework and are evaluated against current approaches. To reduce computing time, importance sampling is implemented to re-weight posterior samples thus avoiding the need to draw samples using Markov chain Monte Carlo techniques. Further, as such studies are generally first-in-man, the safety of patients is paramount. We therefore explore methods for the incorporation of safety considerations into utility functions to ensure that only safe and well-predicted doses are administered. The amalgamation of Bayesian methodology, adaptive design and compound utility functions is termed adaptive Bayesian compound design (ABCD). The performance of this amalgamation of methodology is investigated via the simulation of dose finding studies. The paper concludes with a discussion of results and extensions that could be included into our approach.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Oral intake of ascorbic acid is essential for optimum health in human beings. Continuous ambulatory peritoneal dialysis (CAPD) patients have an increased need for ascorbic acid, because of increased loss through dialysate, reduced intake owing to nausea and loss of appetite, and increased oxidative stress. However, optimum intake is still controversial. We studied 50 clinically stable patients to determine the relationship between oral ascorbic acid intake and serum ascorbic acid (SAA) level. Total oral intake ranged from 28 mg daily to 412 mg daily. Only one patient had an oral intake of ascorbic acid below 60 mg per day. The SAA levels ranged from 1 mg/L to 36.17 mg/L. Although a strong correlation existed between intake and SAA (p < 0.001, R2 = 0.47), the variation in SAA at any given intake level was wide. Of the studied patients, 62% had an SAA < 8.7 mg/L, 40% had an SAA < 5.1 mg/L (below the level in a healthy population), and 12% had a level below 2 mg/L (scorbutic). None of the patients demonstrated clinical manifestations of scurvy. Our results show that, in CAPD patients, ascorbic acid deficiency can be reliably detected only with SAA measurements, and oral intake may influence SAA level. To maintain ascorbic acid in the normal range for healthy adults, daily oral intake needs to be increased above the U.S. recommended dietary allowance to 80-140 mg.