965 resultados para descending aorta


Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND Malperfusion adversely affects outcomes in patients with acute type A aortic dissection, but reliable quantitative data are lacking. OBJECTIVES The aim of this study was to analyze the impact of various forms of malperfusion on early outcome. METHODS A total of 2,137 consecutive patients enrolled in GERAADA (German Registry for Acute Aortic Dissection Type A) who underwent surgery between 2006 and 2010, of whom 717 (33.6%) had any kind of pre-operative malperfusion, were retrospectively analyzed. RESULTS All-cause 30-day mortality was 16.9% and varied substantially according to the number of organ systems affected by malperfusion (none, 12.6%; 1 system, 21.3%; 2 systems, 30.9%; 3 systems, 43.4%; p < 0.001). Pre-operative cerebral malperfusion, comatose state, peripheral malperfusion, visceral malperfusion, involvement of supra-aortic branches, coronary malperfusion, and renal malperfusion were all independent predictors of developing any post-operative malperfusion syndrome. When survival was considered, age, peripheral malperfusion, involvement of supra-aortic branches, coronary malperfusion, spinal malperfusion, a primary entry in the descending aorta, and pre-operative comatose state were independent predictors, again with increasing significance. CONCLUSIONS Malperfusion remains a severe clinical condition with strong potential for adverse outcomes in patients undergoing surgery for acute type A aortic dissection. The GERAADA registry suggests that the impact of the number of organs involved and the type of malperfusion on outcome differs substantially. Introducing an appropriate classification system, such as "complicated" and uncomplicated" acute type A aortic dissection, might help predict individual risk as well as select a surgical strategy that may quickly resolve malperfusion.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The implementation of new surgical techniques offers chances but carries risks. Usually, several years pass before a critical appraisal and a balanced opinion of a new treatment method are available and rely on the evidence from the literature and expert's opinion. The frozen elephant trunk (FET) technique has been increasingly used to treat complex pathologies of the aortic arch and the descending aorta, but there still is an ongoing discussion within the surgical community about the optimal indications. This paper represents a common effort of the Vascular Domain of EACTS together with several surgeons with particular expertise in aortic surgery, and summarizes the current knowledge and the state of the art about the FET technique. The majority of the information about the FET technique has been extracted from 97 focused publications already available in the PubMed database (cohort studies, case reports, reviews, small series, meta-analyses and best evidence topics) published in English.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

To assess spatial and temporal pressure characteristics in patients with repaired aortic coarctation compared to young healthy volunteers using time-resolved velocity-encoded three-dimensional phase-contrast magnetic resonance imaging (4D flow MRI) and derived 4D pressure difference maps. After in vitro validation against invasive catheterization as gold standard, 4D flow MRI of the thoracic aorta was performed at 1.5T in 13 consecutive patients after aortic coarctation repair without recoarctation and 13 healthy volunteers. Using in-house developed processing software, 4D pressure difference maps were computed based on the Navier-Stokes equation. Pressure difference amplitudes, maximum slope of pressure amplitudes and spatial pressure range at mid systole were retrospectively measured by three readers, and twice by one reader to assess inter- and intraobserver agreement. In vitro, pressure differences derived from 4D flow MRI showed excellent agreement to invasive catheter measurements. In vivo, pressure difference amplitudes, maximum slope of pressure difference amplitudes and spatial pressure range at mid systole were significantly increased in patients compared to volunteers in the aortic arch, the proximal descending and the distal descending thoracic aorta (p < 0.05). Greatest differences occurred in the proximal descending aorta with values of the three parameters for patients versus volunteers being 19.7 ± 7.5 versus 10.0 ± 2.0 (p < 0.001), 10.9 ± 10.4 versus 1.9 ± 0.4 (p = 0.002), and 8.7 ± 6.3 versus 1.6 ± 0.9 (p < 0.001). Inter- and intraobserver agreements were excellent (p < 0.001). Noninvasive 4D pressure difference mapping derived from 4D flow MRI enables detection of altered intraluminal aortic pressures and showed significant spatial and temporal changes in patients with repaired aortic coarctation.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Cardiovascular disease (CVD) continues to be one of the top causes of mortality in the world. World Heart Organization (WHO) reported that in 2004, CVD contributed to almost 30% of death from estimated worldwide death figures of 58 million[1]. Heart failure treatment varies from lifestyle adjustment to heart transplantation; its aims are to reduce HF symptoms, prolong patient survival and minimize risk [2]. One alternative available in the market for HF treatment is Left Ventricular Assist Device (LVAD). Chronic Intermittent Mechanical Support (CIMS) device is a novel (LVAD) heart failure treatment using counterpulsation similar to Intra Aortic Balloon Pumps (IABP). However, the implantation site of the CIMS balloon is in the ascending aorta just distal to aortic valve contrasted with IABP in the descending aorta. Counterpulsation coupled with implantation close to the aortic valve enables comparable flow augmentation with reduced balloon volume. Two prototypes of the CIMS balloon were constructed using rapid prototyping: the straight-body model is a cylindrical tube with a silicone membrane lining with zero expansive compliance. The compliant-body model had a bulging structure that allowed the membrane to expand under native systolic pressure increasing the device’s static compliance to 1.5 mL/mmHg. This study examined the effect of device compliance and vascular compliance on counterpulsating flow augmentation. Both prototypes were tested on a two-element Windkessel model human mock circulatory loop (MCL). The devices were placed just distal to aortic valve and left coronary artery. The MCL mimicked HF with cardiac output of 3 L/min, left ventricular pressure of 85/15 mmHg, aortic pressure of 70/50 mmHg and left coronary artery flow rate of 66 mL/min. The mean arterial pressure (MAP) was calculated to be 57 mmHg. Arterial compliance was set to be1.25 mL/mmHg and 2.5 mL/mmHg. Inflation of the balloon was triggered at the dicrotic notch while deflation was at minimum aortic pressure prior to systole. Important haemodynamics parameters such as left ventricular pressure (LVP), aortic pressure (AoP), cardiac output (CO), left coronary artery flowrate (QcorMean), and dP (Peak aortic diastolic augmentation pressure – AoPmax ) were simultaneously recorded for both non-assisted mode and assisted mode. ANOVA was used to analyse the effect of both factors (balloon and arterial compliance) to flow augmentation. The results showed that for cardiac output and left coronary artery flowrate, there were significant difference between balloon and arterial compliance at p < 0.001. Cardiac output recorded maximum output at 18% for compliant body and stiff arterial compliance. Left coronary artery flowrate also recorded around 20% increase due to compliant body and stiffer arterial compliance. Resistance to blood ejection recorded highest difference for combination of straight body and stiffer arterial compliance. From these results it is clear that both balloon and arterial compliance are statistically significant factors for flow augmentation on peripheral artery and reduction of resistance. Although the result for resistance reduction was different from flow augmentation, these results serves as an important aspect which will influence the future design of the CIMS balloon and its control strategy. References: 1. Mathers C, Boerma T, Fat DM. The Global Burden of disease:2004 update. Geneva: World Heatlh Organization; 2008. 2. Jessup M, Brozena S. Heart Failure. N Engl J Med 2003;348:2007-18.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Voluntary methadone administration for the purpose of sedation eventually resulting in the infant's death is extremely infrequent, though it has been observed. In this report, we describe an autopsy case pertaining to a 32-month-old infant who was repeatedly exposed to methadone by his parents. Autopsy revealed a coarctation of the aorta with a focal stenosis located at the junction of the distal aortic arch and the descending aorta. Left ventricular hypertrophy was also observed. Both these findings were considered to not have played a role in the child's death. Methadone was detected in the femoral blood (0.633 mg/l), urine (5.25 mg/l), bile (2.64 mg/l), and gastric contents (1.08 mg). A segmental hair analysis showed the presence of methadone and morphine in both the proximal and distal portion of the lock. Methadone was also detected in nail samples. A segmental hair analysis performed on the younger brother of the deceased revealed the presence of methadone and morphine in both the proximal and distal segments, as well as the presence of 6-monoacetylmorphine exclusively in the distal portion. Though the parents denied any involvement in methadone administration or exposure for the purpose of sedation, the manner of death was listed as homicide. The case emphasizes the usefulness of hair analysis to identify threatening situations for the children of drug-dependent parents and possibly support measures by the authorities to recognize and intervene in these potentially fatal situations.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Background: The frozen elephant trunk(FET) technique is one of the last evolution in the treatment of complex pathologies of the aortic arch and the descending thoracic aorta.Materials and methods: Between January 2007 and March 2021, a total of 396 patients underwent total aortic arch replacements with the FET technique in our centre.The main indications were thoracic aortic aneurysm(n=104,28.2%), chronic aortic dissection(n=224,53.4%) and acute aortic dissection(n=68, 18.4%). We divided the population in two groups according the position of the distal anastomosis (zone 2 vs zone 3) and the length of the stent graft (< 150 mm vs > 150 mm): conservative group (Zone 2 anastomosis + stent length < 150mm, n. 140 pts) and aggressive group (zone 3 anastomosis + stent length > 150mm, n. 141). Results: The overall 30-day mortality rate was 13%(48/369); the risk factor analysis showed that an aggressive approach was neither a risk factor for major complication (permanent dialysis, tracheostomy, bowel malperfusion and permanent paraplegia) neither for 30-day mortality. The survival rate at 1, 5,10 and 15 years was 87.7%,75%,61.3% and 58.4% respectively. During the follow up, an aortic reintervention was performed in 122 patients (38%), 5 patients received a non-aortic cardiac surgery. Freedom from aortic reintervention at 1-,5- and 10-year was 77%,54% and 44% respectively. The freedom from aortic reintervention was higher in the ‘aggressive’ group (62.5%vs40.0% at 5 years, log-rank=0.056). An aggressive approach was not protective for aortic reintervention at follow up and for death at follow up. Conclusions: The FET technique represents a feasible and efficient option in the treatment of complex thoracic aortic pathologies. An aortic reintervention after FET is very common and the decision-making approach should consider and balance the higher risk of an aggressive approach in terms of post-operative complication versus the higher risk of a second aortic reintervention at follow-up.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Despite the improvements achieved in antibiotic therapy, severe aortic infection resulting in mycotic aneurysms is still a highly lethal disease and surgical management remains a challenging task. PATIENTS AND METHODS: A total of 43 patients with severe aortic infections were analyzed and separated in four groups: (1) Infections of the aortic root Ventriculo-aortic disconnection due to deep aortic infection (6 patients). Two patients were operated using homo-composit grafts. Of the 6 patients total, one died early and two died late during a mean follow-up of 6 years. The two patients with homografts are still alive. (2) Infections of the ascending aorta and the aortic arch. In situ repair for mycotic aneurysmal lesions of the ascending aorta was performed in 6 patients using synthetic graft material in 4/6, biological material in 1/6 and direct suture in 1/6. Two patients had to be reoperated; one of them died early. There was no recurrent infection during a mean follow-up of 6 years. (3) Infections of the descending thoracic and thoraco-abdominal aorta in-situ repair for mycotic aneurysmal lesions of the descending and thoraco-abdominal aorta was performed in 12 patients using homografts in five. Two patients died early and two other patients died late during a mean follow-up of 6 years. (4) Infections of the infrarenal abdominal aorta. In this series of 19 patients with mycotic infrarenal aortic aneurysms, in situ reconstruction was performed in 12 (5/12 with homografts) and extra-anatomic reconstruction (axillo-femoral bypass) was performed in 7. Hospital mortality was 5/19 patients and another 5/19 patients died during a mean follow-up of 6 years. One of the early deaths was due to aortic stump rupture. Two patients with axillo-femoral reconstructions were later converted to descending-thoracic-aortic-bifemoral bypasses. Five thromboses of axillo-femoral bypasses were observed in three of the seven patients with extra-anatomic repairs. RESULTS: Infections of the aortic root, the ascending aorta and the aortic arch are approached with total cardio-pulmonary bypass, using cardioplegic myocardial protection and deep hypothermia with circulatory arrest if necessary. Proximal unloading and distal support using partial cardiopulmonary bypass is preferred for repair of infected descending and thoracoabdominal aortic lesions, whereas no such adjuncts are required for repair of infected infrarenal aortic lesions. CONCLUSIONS: The anatomical location of the aortic infection and the availability of homologous graft material are the main factors determining the surgical strategy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aortotracheal fistula is a rare condition that is invariably fatal if not diagnosed and surgically treated. Patients usually present with small intermittent hemoptysis. The findings using computerized tomography (CT) are usually diagnostic. CT should be considered in the initial investigation of patients suspected to have such a disease. A 62-year-old woman with a aneurysm of the descending thoracic aorta presented with new-onset back pain and hemoptysis. The hemoptysis was thought to be the result of invasion of the bronchial tree by the aneurysm.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

El reparo endovascular de la aorta torácica (REVAT), se ha incrementado en el mundo en los últimos años con relación al abierto. Los resultados de la intervención son controversiales. La información en Colombia es insuficiente. Objetivo: Comparar los resultados clínicos del REVAT frente al reparo abierto en la Fundación Cardio Infantil (Bogotá, Col) entre 2002 y 2011. Metodología: Análisis retrospectivo de la cohorte de pacientes sometidos a reparo abierto (Grupo 1) en comparación de REVAT (grupo 2). En cada uno de los grupos se evaluó el tiempo quirúrgico, tasa de morbilidad (infección, hemo-rragia, isquemia medular, evento cerebrovascular [ECV] y falla renal postoperatoria), mortalidad, reintervención y estancia hospitalaria. Para las comparaciones se realizó un análisis univariado considerando un valor p<0.05 estadísticamente significativo. Resultados: Fueron incluidos 57 pacientes en el análisis (26% reparo abierto; 74% REVAT). Se reintervinieron 2 pacientes por endofugas tipo 1 en el Grupo 2 y un caso por sangrado en el Grupo 1. La mortalidad operatoria fue (Grupo1: 20%; Grupo 2: 2.3%). El tiempo quirúrgico fue de 398 ± 180 min Grupo 1 versus 85.5 ± 35 min en el Grupo 2 (p:0.0001) y el tiempo de estancia hospitalaria promedio fue de 9.8 días:Grupo 1 y 5,3 días Grupo 2 [p:0.01]). El tiempo promedio de seguimiento fue 4,8± 3,1 años. Conclusiones: El REVAT parece ofrecer menor morbilidad, mortalidad, tiempo quirúrgico y estancia hospitalaria respecto al reparo abierto, aunque las pobla-ciones de pacientes incluidos no fueron estrictamente comparables. Se requieren nuevos análisis en un diseño prospectivo, idealmente aleatorizado para documentar los beneficios a largo plazo de este tipo de reparo.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES The purpose of this study is to delineate changes in aortic geometry and diameter due to dissection. BACKGROUND Aortic diameter is the major criterion for elective ascending aortic replacement for dilated ascending aortas to prevent aortic dissection. However, recommendations are made on the basis of clinical experience and observation of diameters of previously dissected aortas. METHODS Six tertiary centers on 2 continents reviewed their acute aortic dissection type A databases, which contained 1,821 patients. Included were all non-Marfan patients with nonbicuspid aortic valves who had undergone computed tomography angiography <2 years before and within 12 h after aortic dissection onset. Aortic geometry before and after dissection onset were compared. RESULTS Altogether, 63 patients were included (27 spontaneous and 36 retrograde dissections, median age 68 [57; 77] years; 54% were men). In all but 1 patient, maximum ascending aortic diameter was <55 mm before aortic dissection onset. The largest increase in diameter and volume induced by the dissection were observed in the ascending aorta (40.1 [36.6; 45.3] mm vs. 52.9 [46.1; 58.6] mm, +12.8 mm; p < 0.001; 124.0 [90.8; 162.5] cm(3) vs. 171.0 [147.0; 197.0] cm(3), +47 cm(3); p < 0.001). Mean aortic arch diameter increased from 39.8 (30.5; 42.6) mm to 46.4 (42.0; 51.6) mm (+6.6 mm; p < 0.001) and descending thoracic aorta diameter from 31.2 (27.0; 33.3) mm to 34.9 (30.9; 39.5) mm (+3.7 mm; p < 0.001). Changes in thoracic aorta geometry were similar for spontaneous and retrograde etiology. CONCLUSIONS Geometry of the thoracic aorta is affected by aortic dissection, leading to an increase in diameter that is most pronounced in the ascending aorta. Both spontaneous and retrograde dissection result in similar aortic geometry changes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introdution: The transcatheter aortic valve implantation in the treatment of high-risk symptomatic aortic stenosis has increased the number of implants every year. The learning curve for transcatheter aortic valve implantation has improved since the last 12 years, allowing access alternatives. The aim of this study is to approach the implantation of transcatheter aortic valve through transaortic via associated with off-pump cardiopulmonary bypass surgery in a 67-year-old man, with chronic obstructive pulmonary disease, arterial hypertension and kidney transplant. Off-pump coronary artery bypass surgery was performed and the valve in the aortic position was released successfully. There were no complications in the intraoperative and postoperative period. Gradient reduction, effective orifice increasing of the prosthesis and absence of valvular regurgitation after implantation were observed by transesophageal echocardiography. Procedural success demonstrates that implantation of transcatheter aortic valve through the ascending aorta associated with coronary artery bypass surgery without CPB is a new option for these patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: Avaliar as características demográficas e de imagens da trombose endoluminal em uma série de pacientes submetidos a tratamento endovascular do aneurisma de aorta abdominal (TEAAA). MÉTODOS: Avaliamos as características de imagem que permitiram o diagnóstico da trombose endoluminal em uma série de 30 pacientes submetidos ao TEAAA, com seguimento de 5 a 29 meses, através de exames de tomografia computadorizada multidetectores (TCMD) de 64 canais. RESULTADOS: Foram diagnosticados dez casos de trombose luminal (33,3%), sendo que em três pacientes a trombose foi total de um ramo ilíaco. CONCLUSÃO: A TCMD permitiu o diagnóstico de diferentes tipos de trombose endoluminal em pacientes submetidos ao TEAAA. O uso desta modalidade diagnóstica minimamente invasiva deverá ser encorajado na prática clínica.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Descending pronociceptive pathways may be implicated in states of persistent pain. Paw skin incision is a well-established postoperative pain model that causes behavioral nociceptive responses and enhanced excitability of spinal dorsal horn neurons. The number of spinal c-Fos positive neurons of rats treated intrathecally with serotonin, noradrenaline or acetylcholine antagonists where evaluated to study the descending pathways activated by a surgical paw incision. Results: The number of c-Fos positive neurons in laminae I/II ipsilateral, lamina V bilateral to the incised paw, and in lamina X significantly increased after the incision. These changes: remained unchanged in phenoxybenzamine-treated rats; were increased in the contralateral lamina V of atropine-treated rats; were inhibited in the ipsilateral lamina I/II by 5-HT(1/2B/2C) (methysergide), 5-HT(2A) (ketanserin) or 5-HT(1/2A/2C/5/6/7) (methiothepin) receptors antagonists, in the ipsilateral lamina V by methysergide or methiothepin, in the contralateral lamina V by all the serotonergic antagonists and in the lamina X by LY 278,584, ketanserin or methiothepin. Conclusions: We conclude: (1) muscarinic cholinergic mechanisms reduce incision-induced response of spinal neurons inputs from the contralateral paw; (2) 5-HT(1/2A/2C/3) receptors-mediate mechanisms increase the activity of descending pathways that facilitates the response of spinal neurons to noxious inputs from the contralateral paw; (3) 5-HT(1/2A/2C) and 5-HT(1/2C) receptors increases the descending facilitation mechanisms induced by incision in the ipsilateral paw; (4) 5-HT(2A/3) receptors contribute to descending pronociceptive pathways conveyed by lamina X spinal neurons; (5) alpha-adrenergic receptors are unlikely to participate in the incision-induced facilitation of the spinal neurons.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We investigated the mechanism by which extracellular acidification promotes relaxation in rat thoracic aorta. The relaxation response to HCl-induced extracellular acidification (7.4 to 6.5) was measured in aortic rings pre-contracted with phenylephrine (Phe, 10(-6) M) or KCl (45 mM). The vascular reactivity experiments were performed in endothelium-intact and denuded rings, in the presence or absence of indomethacin (10(-5) M), L-NAME (10(-4) M), apamin (10(-6) M), and glibenclamide (10(-5) M). The effect of extracellular acidosis (pH 7.0 and 6.5) on nitric oxide (NO) production was evaluated in isolated endothelial cells loaded with diaminofluorescein-FM diacetate (DAF-FM DA, 5 mu M). The extracellular acidosis failed to induce any changes in the vascular tone of aortic rings pre-contracted with KCl, however, it caused endothelium-dependent and independent relaxation in rings pre-contracted with Phe. This acidosis induced-relaxation was inhibited by L-NAME, apamin, and glibenclamide, but not by indomethacin. The acidosis (pH 7.0 and 6.5) also promoted a time-dependent increase in the NO production by the isolated endothelial cells. These results suggest that extracellular acidosis promotes vasodilation mediated by NO, K(ATP) and SK(Ca), and maybe other K(+) channels in isolated rat thoracic aorta. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: To investigate the mechanism through which the extracellular alkalinization promotes relaxation in rat thoracic aorta. Methods: The relaxation response to NaOH-induced extracellular alkalinization (7.4-8.5) was measured in aortic rings pre-contracted with phenylephrine (Phe, 10(-6) M). The vascular reactivity experiments were performed in endothelium-intact and -denuded rings, in the presence or and absence of indomethacin (10(-5) M), NG-nitro-L-arginine methyl ester (L-NAME, 10(-4) M), N-(6-Aminohexyl)-5-chloro-1-naphthalenesulfonamide/HCl (W-7, 10(-7) M), 2,5-dimethylbenzimidazole (DMB, 2 x 10(-5) M) and methyl-B-cyclodextrin (10(-2) M). In addition, the effects of NaOH-induced extracellular alkalinization (pH 8.0 and 8.5) on the intracellular nitric oxide (NO) concentration was evaluated in isolated endothelial cells loaded with diaminofluorescein-FM diacetate (DAF-FM DA, 5 mu M), in the presence and absence of DMB (2 x 10(-5) M). Results: The extracellular alkalinization failed to induce any change in vascular tone in aortic rings pre-contracted with KCl. In rings pre-contracted with Phe, the extracellular alkalinization caused relaxation in the endothelium-intact rings only, and this relaxation was maintained after cyclooxygenase inhibition; completely abolished by the inhibition of nitric oxide synthase (NOS), Ca(2+)/calmodulin and Na(+)/Ca(2+). exchanger (NCX), and partially blunted by the caveolae disassembly. Conclusions: These results suggest that, in rat thoracic aorta, that extracellular alkalinization with NaOH activates the NCX reverse mode of endothelial cells in rat thoracic aorta, thereby the intracellular Ca(2+) concentration and activating the Ca(2+)/calmodulin-dependent NOS. In turn, NO is released promoting relaxation. (C) 2010 Elsevier Inc. All rights reserved.