928 resultados para conditions of contact


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A combination of factors has dictated patterns of prescribing to contact lens wearers in different age groups over time, such as the evolution of manufacturing technology in bringing better lens designs and replacement frequency options; the aging population demographic; and the knowledge and attitudes of practitioners. Here we explore evolving lens fitting practices at the opposite poles of the age spectrum—children and presbyopes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Rigid lenses, which were originally made from glass (between 1888 and 1940) and later from polymethyl methacrylate or silicone acrylate materials, are uncomfortable to wear and are now seldom fitted to new patients. Contact lenses became a popular mode of ophthalmic refractive error correction following the discovery of the first hydrogel material – hydroxyethyl methacrylate – by Czech chemist Otto Wichterle in 1960. To satisfy the requirements for ocular biocompatibility, contact lenses must be transparent and optically stable (for clear vision), have a low elastic modulus (for good comfort), have a hydrophilic surface (for good wettability), and be permeable to certain metabolites, especially oxygen, to allow for normal corneal metabolism and respiration during lens wear. A major breakthrough in respect of the last of these requirements was the development of silicone hydrogel soft lenses in 1999 and techniques for making the surface hydrophilic. The vast majority of contact lenses distributed worldwide are mass-produced using cast molding, although spin casting is also used. These advanced mass-production techniques have facilitated the frequent disposal of contact lenses, leading to improvements in ocular health and fewer complications. More than one-third of all soft contact lenses sold today are designed to be discarded daily (i.e., ‘daily disposable’ lenses).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE. To examine the deposition of tear phospholipids and cholesterol onto worn contact lenses and the effect of lens material and lens care solution. METHODS. Lipids were extracted from tears and worn contact lenses using 2:1 chloroform: Methanol and the extract washed with aqueous ammonium acetate, before analysis by electrospray ionization tandem mass spectrometry (ESI-MS/MS). RESULTS. Twenty-three molecular lipids from the sphingomyelin (SM) and phosphatidylcholine (PC) classes were detected in tears, with total concentrations of each class determined to be 5 ± 1 pmol/μL (~3.8 μg/mL) and 6 ± 1 pmol/μL (~ 4.6μg/mL), respectively. The profile of individual phospholipids in both of these classes was shown to be similar in contact lens deposits. Deposition of representative polar and nonpolar lipids were shown to be significantly higher on senofilcon A contact lenses, with ~59 ng/lens SM, 195 ng/lens PC, and 9.9 μg/lens cholesterol detected, whereas balafilcon A lens extracts contained ~19 ng/lens SM, 19 ng/lens PC, and 3.9 μg/lens cholesterol. Extracts from lenses disinfected and cleaned with two lens care solutions showed no significant differences in total PC and SM concentrations; however, a greater proportion of PC than SM was observed, compared with that in tears. CONCLUSIONS. Phospholipid deposits extracted from worn contact lenses show a molecular profile similar to that in tears. The concentration of representative polar and nonpolar lipids deposited onto contact lenses is significantly affected by lens composition. There is a differential efficacy in the removal of PC and SM with lens care solutions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background A population-based, cross-sectional telephone survey was conducted to estimate the penetrance and characteristics of contact lens wear in Australia. Methods Based on postcode distribution, 42,749 households around Australia were randomly selected from the national electronic telephone directory. During calls, the number of individuals and contact lens wearers in each household aged between 15 and 64 years was ascertained. Contact lens wearers were interviewed using a structured questionnaire, to determine details of demographics, lens type, mode of lens wear and hygienic habits. Contact lens wear characteristics and habits were compared by lens type and mode of use. Results Of the 32,405 households contacted, 19,171 (59.2 per cent) agreed to participate. The penetrance of contact lens wear during the study period was 5.01 per cent (95% CI: 4.78-5.24). The mean age of lens wearers was 36.5 ± 18.3 years and 63.4 per cent were female. There were significant differences in the habits and characteristics of lens wearers depending on their lens type and mode of use. Conclusions The penetrance of contact lens wear concurs with market estimates and equates to approximately 680,000 contact lens wearers aged between 15 and 64 years in Australia. This is the most detailed and extensive population-based survey of contact lens wearers ever conducted. The discrepancies found between the characteristics of lens wearers surveyed in this study compared to those in previous studies of contact lens practitioners highlights the importance of study design. These results may be applied to other regions with similar health-care and regulatory systems.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Bulk heterojunction organic solar cells based on poly[4,7-bis(3- dodecylthiophene-2-yl) benzothiadiazole-co-benzothiadiazole] and [6,6]-phenyl C71-butyric acid methyl ester are investigated. A prominent kink is observed in the fourth quadrant of the current density-voltage (J-V) response. Annealing the active layer prior to cathode deposition eliminates the kink. The kink is attributed to an extraction barrier. The J-V response in these devices is well described by a power law. This behavior is attributed to an imbalance in charge carrier mobility. An expected photocurrent for the device displaying a kink in the J-V response is determined by fitting to a power law. The difference between the expected and measured photocurrent allows for the determination of a voltage drop within the device. Under simulated 1 sun irradiance, the peak voltage drop and contact resistance at short circuit are 0.14 V and 90 Ω, respectively. © 2012 American Institute of Physics.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose The aim was to assess the compatibility of different multipurpose solutions (MPSs) with one type of silicone hydrogel (SiH) contact lens by, assessing the changes in both ultraviolet (UV) and visible light transmissibility of the hydrogel lens caused by the MPSs. Methods The light transmittance from 200-700 nm were measured for the lotrafilcon B blister pack solution (BPS), six MPSs namely, ReNuMultiPlus Multi-Purpose Solution (Bausch and Lomb Inc., Rochester NY, USA.); Complete RevitaLens Multi-Purpose (Abbott Medical Optics Inc., Quarryvale Co. Dublin, Ireland); All In One Light (Sauflon Pharmaceuticals Ltd., Twickenham, England); SOLO-care AQUA™ (Ciba Vision Corporation Duluth, Georgia, USA.); Biomedics All-in-one solution (CooperVision, Hamble, UK); and HippiaMultiPlus All-in-one solution (Interojo Inc., Kyeonggi-do, Korea), and a lotrafilcon B SiH lens (before and after storage), using a spectrophotometer. Results The UV transmitted through the BPS and the MPS were similar (p >.05, for all), except for the HippiaMultiPlus which was lower (p < 0.001) by 19.8%. Mean transparency values were statistically (p<.001) significantly different between the BPS and the MPSs. All MP solution/SiH lens combinations resulted in relatively high UV transmittance values especially in the UVC spectrum, and significantly increased (p <.001) the visible light transmittance values of the SiH lens. Greater changes in transparency were observed in the ReNu/SiH lens (28.5%) and the Complete RevitaLens/SiH lens (24.9%) combinations. Conclusion The six MPSs showed significant variations in the transmitted UV and visible light. Similar to the BPS, all MPSs were equally transparent, but showed very poor UVA & UVB attenuation, except for the Hippia MultiPlus. The MPS/SiH lens combinations did not significantly affect the lens transparency but it significant increased the lens transmittance of UV radiation, after storage. Further in-vivo studies are needed to validate if this effect is constant.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Extensive research conducted in the occupational stress literature has failed to provide convincing support for the stress-buffering effects of work control on employee adjustment. Drawing on research conducted in the laboratory context, it was proposed that the stress-buffering effects of work control on employee adjustment would be more marked at high, rather than low, levels of self-efficacy. In a sample of 100 customer service representatives, a significant three-way interaction among role conflict, work control and self-efficacy (measured at Time 1) was observed on (low) depersonalization (measured at Time 2). Consistent with expectations, work control reduced the negative effects of work stress on this outcome measure only for employees who perceived high levels of self-efficacy at work. In addition, there was evidence to suggest that self-efficacy moderated the main effects of work control on job satisfaction and somatic health. These findings are discussed in terms of their theoretical contribution to the job strain model, and also in relation to workplace interventions designed to improve levels of employee adjustment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Prediction of the initiation, appearance and emergence of leaves is critically important to the success of simulation models of crop canopy development and some aspects of crop ontogeny. Data on leaf number and crop ontogeny were collected on five cultivars of maize differing widely in maturity and genetic background grown under natural and extended photoperiods, and planted on seven sowing dates from October 1993 to March 1994 at Gatton, South-east Queensland. The same temperature coefficients were established for crop ontogeny before silking, and the rates of leaf initiation, leaf tip appearance and full leaf expansion, the base, optimum and maximum temperatures for each being 8, 34 and 40 degrees C. After silking, the base temperature for ontogeny was 0 degrees C, but the optimum and maximum temperatures remained unchanged. The rates of leaf initiation, appearance of leaf tips and full leaf expansion varied in a relatively narrow range across sowing times and photoperiod treatments, with average values of 0.040 leaves (degrees Cd)-1, 0.021 leaves (degrees Cd)-1, and 0.019 leaves (degrees Cd)-1, respectively. The relationships developed in this study provided satisfactory predictions of leaf number and crop ontogeny (tassel initiation to silking, emergence to silking and silking to physiological maturity) when assessed using independent data from Gatton (South eastern Queensland), Katherine and Douglas Daly (Northern Territory), Walkamin (North Queensland) and Kununurra (Western Australia).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction Cannabis remains the most used illegal substance across the globe, and negative outcomes and disorders are common. A spotlight therefore falls on reductions in cannabis use in people with cannabis use disorder. Current estimates of unassisted cessation or reduction in cannabis use rely on community surveys, and few studies focus on individuals with disorder. A key interest of services and researchers is to estimate effect size of reductions in consumption among treatment seekers who do not obtain treatment. Effects within waiting list or information-only control conditions of randomised controlled trials offer an opportunity to study this question. Method This paper examines the extent of reductions in days of cannabis use in the control groups of randomised controlled trials on treatment of cannabis use disorders. A systematic literature search was performed to identify trials that reported days of cannabis use in the previous 30 (or equivalent). Results Since all but one of the eight identified studies had delayed treatment controls, results could only be summarised across 2–4 months. Average weighted days of use in the previous 30 days fell from 24.5 to 19.9, and a meta-analysis using a random effects model showed an average reduction of 0.442 SD. However, every study had at least one significant methodological issue. Conclusions While further high-quality data is needed to confirm the observed effects, these results provide a baseline from which researchers and practitioners can estimate the extent of change required to detect effects of cannabis treatments in services or treatment trials.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

1. 1. An increase in the oxidation of succinate by hepatic mitochondria in rats exposed to hypoxia (O2-N2; 1:9, v/v) or hypobaria (0.5 atm) was observed which appears to be due to modification of the activity of the rate-limiting succinate dehydrogenase [succinate: (acceptor) oxidoreductase, EC 1.3.99.1].

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Bearing area analysis has been used to study the real area of contact and compliance of rough turned steel cylinders in compression. Calculations show that the elastic real area of contact is very small compared to the plastic real area of contact, and that local compliance due to flattening of asperity tips is a small proportion of the total compliance obtained from experiments. The fact that increased load brings more and more new asperities under load rather than enlarging the contact spots leads to a rather simple load-compliance relation for a rough cylinder, viz., W' = Nh · K1δn, where W0 = K1δn defines the load-compliance relation of the individual asperities, and Nh represents the number of asperities bearing the load.