995 resultados para circulatory support
Long-term continuous-flow left ventricular assist devices (LVAD) as bridge to heart transplantation.
Resumo:
Heart transplantation (HTx) is the treatment of choice for end-stage heart failure but the limited availability of heart's donors still represents a major issue. So long-term mechanical circulatory support (MCS) has been proposed as an alternative treatment option to assist patients scheduled on HTx waiting list bridging them for a variable time period to cardiac transplantation-the so-called bridge-to-transplantation (BTT) strategy. Nowadays approximately 90% of patients being considered for MCS receive a left ventricular assist device (LVAD). In fact, LVAD experienced several improvements in the last decade and the predominance of continuous-flow over pulsatile-flow technology has been evident since 2008. The aim of the present report is to give an overview of continuous-flow LVAD utilization in the specific setting of the BTT strategy taking into consideration the most representative articles of the scientific literature and focusing the attention on the evolution, clinical outcomes, relevant implications on the HTx strategy and future perspectives of the continuous-flow LVAD technology.
Resumo:
O objetivo foi a padronização de modelo experimental de coração isolado parabiótico em coelhos, testando sua estabilidade e durabilidade, para fins de pesquisa cardiovascular. Foram utilizados 66 coelhos raça Norfolk-2000 divididos em grupo doador do coração isolado e animais suporte, totalizando 33 preparações. Mediante auxilio de bombas peristálticas estabeleceu-se suporte circulatório para o coração isolado mantendo-se fluxo constante(16ml/min.). Um balão intraventricular foi inserido no ventrículo esquerdo, sendo ajustado para gerar pressão diastólica de ± 10mmHg. A freqüência foi fixada em 120 batimentos por minuto mediante o uso de marcapasso. Foram avaliadas variáveis hemodinâmicas, laboratoriais e anatomopatológicas. Das 33 preparações, 13 foram excluídas mediante critérios pré-estabelecidos. Das 20 restantes, 10 cumpriram o tempo máximo do protocolo(180 minutos). Com relação ao animal suporte houve deterioração hemodinâmica progressiva c/ queda da pressão arterial média(89,30±6,09mmHg->47,50±6,35mmHg). Com relação ao corações isolado, das 10 preparações que cumpriram os 180 minutos de protocolo, houve estabilidade hemodinâmica. As variáveis laboratoriais mostraram queda progressiva do sódio, potássio e hemoglobina, sendo compatível com hemodiluição. O exame anatomopatológico mostrou espaçamento maior entre fibras, compatível com edema. O presente modelo mostrou estabilidade e atividade de 100% das preparações em 60 minutos, havendo perdas progressivas chegando a 50% das preparações em atividade em 180 minutos. O presente modelo, dentro das limitações estabelecidas é viável para pesquisas cardiovasculares.
Resumo:
OBJETIVO: Este estudo avaliou o desempenho hemodinâmico e as alterações miocárdicas decorrentes do emprego de dispositivos de assistência ventricular esquerda (DAVE), associado ou não à descompressão do ventrículo direito por meio de derivação cavo-pulmonar, sendo esses achados comparados ao emprego de assistência circulatória biventricular. MÉTODOS: Vinte e um suínos foram submetidos à indução de insuficiência cardíaca através de fibrilação ventricular, sendo a atividade circulatória mantida por DAVE durante 180 minutos. No grupo controle, foi apenas implantado o DAVE. No grupo derivação, além do DAVE foi realizada cirurgia de derivação cavo-pulmonar. No grupo biventricular, foi instituída assistência biventricular. Foram monitoradas as pressões intracavitárias por 3 horas de assistência e amostras do endocárdio dos dois ventrículos foram coletadas e analisadas à microscopia óptica e eletrônica. RESULTADOS: O lactato sérico foi significativamente menor no grupo biventricular (P=0,014). A diferença observada entre o fluxo do DAVE nos grupos derivação e controle (+55±14 ml/kg/min, P=0,072) não foi significativa, enquanto que o fluxo no grupo biventricular foi significativamente maior (+93±17 ml/kg/min, P=0,012) e se manteve estável durante o experimento. A pressão arterial média (PAM) se manteve constante apenas no grupo biventricular (P<0,001), que também apresentou diminuição significativa das pressões em câmaras direitas. Na análise ultraestrutural, notou-se menor presença edema miocárdico no ventrículo direito no grupo biventricular (P=0,017). CONCLUSÃO: Os resultados apresentados demonstram que o desempenho hemodinâmico da assistência ventricular esquerda associada à derivação cavo-pulmonar, neste modelo experimental, não foi superior ao observado com a assistência de ventrículo esquerdo isolada e não substituiu a assistência biventricular de maneira efetiva.
Resumo:
The PediaFlow pediatric ventricular assist device is a miniature magnetically levitated mixed flow pump under development for circulatory support of newborns and infants (3-15 kg) with a targeted flow range of 0.3-1.5 L/min. The first generation design of the PediaFlow (PF1) was manufactured with a weight of approximately 100 g, priming volume less than 2 mL, length of 51 mm, outer diameter of 28 mm, and with 5-mm blood ports. PF1 was evaluated in an in vitro flow loop for 6 h and implanted in ovines for three chronic experiments of 6, 17, and 10 days. In the in vitro test, normalized index of hemolysis was 0.0087 ± 0.0024 g/100L. Hemodynamic performance and blood biocompatibility of PF1 were characterized in vivo by measurements of plasma free hemoglobin, plasma fibrinogen, total plasma protein, and with novel flow cytometric assays to quantify circulating activated ovine platelets. The mean plasma free hemoglobin values for the three chronic studies were 4.6 ± 2.7, 13.3 ± 7.9, and 8.8 ± 3.3 mg/dL, respectively. Platelet activation was low for portions of several studies but consistently rose along with observed animal and pump complications. The PF1 prototype generated promising results in terms of low hemolysis and platelet activation in the absence of complications. Hemodynamic results validated the magnetic bearing design and provided the platform for design iterations to meet the objective of providing circulatory support for young children with exceptional biocompatibility.
Resumo:
Improvement of heart failure therapy has led to a far better survival and quality of life of patients. Treatment of the underlying disease, patient education and improvement of compliance and consequent upgrading of medical heart failure therapy often delays further progression to an advanced stage of heart failure. Nevertheless heart failure remains a chronic progressive disease and it is up to the treating clinician to identify the signs of advanced heart failure in a timely manner in order to evaluate patients for further treatment strategies such as heart transplantation. This article should help define advanced heart failure and illustrate how patients are evaluated for further therapy. Outcome of heart transplantation or mechanically assisted circulatory support is strongly associated to proper patient selection and timing.
Resumo:
OBJECTIVES: This study analyzes the results of the arterial switch operation for transposition of the great arteries in member institutions of the European Congenital Heart Surgeons Association. METHODS: The records of 613 patients who underwent primary arterial switch operations in each of 19 participating institutions in the period from January 1998 through December 2000 were reviewed retrospectively. RESULTS: A ventricular septal defect was present in 186 (30%) patients. Coronary anatomy was type A in 69% of the patients, and aortic arch pathology was present in 20% of patients with ventricular septal defect. Rashkind septostomy was performed in 75% of the patients, and 69% received prostaglandin. There were 37 hospital deaths (operative mortality, 6%), 13 (3%) for patients with an intact ventricular septum and 24 (13%) for those with a ventricular septal defect (P < .001). In 36% delayed sternal closure was performed, 8% required peritoneal dialysis, and 2% required mechanical circulatory support. Median ventilation time was 58 hours, and intensive care and hospital stay were 6 and 14 days, respectively. Although of various preoperative risk factors the presence of a ventricular septal defect, arch pathology, and coronary anomalies were univariate predictors of operative mortality, only the presence of a ventricular septal defect approached statistical significance (P = .06) on multivariable analysis. Of various operative parameters, aortic crossclamp time and delayed sternal closure were also univariate predictors; however, only the latter was an independent statistically significant predictor of death. CONCLUSIONS: Results of the procedure in European centers are compatible with those in the literature. The presence of a ventricular septal defect is the clinically most important preoperative risk factor for operative death, approaching statistical significance on multivariable analysis.
Resumo:
PURPOSE OF REVIEW: This review will discuss the rationale and clinical utility of percutaneous left ventricular assist devices in the management of patients with cardiogenic shock. RECENT FINDINGS: Left ventricular assist devices maintain partial or total circulatory support in case of severe left ventricular failure. Currently, two percutaneous left ventricular assist devices are available for clinical use: the TandemHeart and the Impella Recover LP system. Compared with the intraaortic balloon pump, the TandemHeart has been shown to significantly reduce preload and to augment cardiac output. In a randomized comparison between the TandemHeart and intraaortic balloon pump support in patients with cardiogenic shock, the improved cardiac index afforded by the left ventricular assist device resulted in a more rapid decrease in serum lactate and improved renal function. There were, however, no significant differences with respect to 30-day mortality, and complications including limb ischemia and severe bleeding were more frequent with left ventricular assist devices than intraaortic balloon pump support. SUMMARY: The advent of percutaneous left ventricular assist devices constitutes an important advance in the management of patients with severe cardiogenic shock and may serve as bridge to recovery or heart transplantation in carefully selected patients. While improvement of hemodynamic parameters appears promising, it remains to be determined whether this benefit translates into improved clinical outcome.
Resumo:
Over the past few decades, advances in ventricular assist device (VAD) technology have provided a promising therapeutic strategy to treat heart failure patients. Despite the improved performance and encouraging clinical outcomes of the new generation of VADs based on rotary blood pumps (RBPs), their physiologic and hematologic effects are controversial. Currently, clinically available RBPs run at constant speed, which results in limited control over cardiac workload and introduces blood flow with reduced pulsatility into the circulation. In this review, we first provide an update on the new challenges of mechanical circulatory support using rotary pumps including blood trauma, increased non-surgical bleeding rate, limited cardiac unloading, vascular malformations, end-organ function, and aortic valve insufficiency. Since the non-physiologic flow characteristic of these devices is one of the main subjects of scientific debate in the literature, we next emphasize the latest research regarding the development of a pulsatile RBP. Finally, we offer an outlook for future research in the field.
Resumo:
The clinical importance of pulsatility is a recurring topic of debate in mechanical circulatory support. Lack of pulsatility has been identified as a possible factor responsible for adverse events and has also demonstrated a role in myocardial perfusion and cardiac recovery. A commonly used method for restoring pulsatility with rotodynamic blood pumps (RBPs) is to modulate the speed profile, synchronized to the cardiac cycle. This introduces additional parameters that influence the (un)loading of the heart, including the timing (phase shift) between the native cardiac cycle and the pump pulses, and the amplitude of speed modulation. In this study, the impact of these parameters upon the heart-RBP interaction was examined in terms of the pressure head-flow (HQ) diagram. The measurements were conducted using a rotodynamic Deltastream DP2 pump in a validated hybrid mock circulation with baroreflex function. The pump was operated with a sinusoidal speed profile, synchronized to the native cardiac cycle. The simulated ventriculo-aortic cannulation showed that the level of (un)loading and the shape of the HQ loops strongly depend on the phase shift. The HQ loops displayed characteristic shapes depending on the phase shift. Increased contribution of native contraction (increased ventricular stroke work [WS ]) resulted in a broadening of the loops. It was found that the previously described linear relationship between WS and the area of the HQ loop for constant pump speeds becomes a family of linear relationships, whose slope depends on the phase shift.
Resumo:
Thesis (Ph.D.)--University of Washington, 2016-06
Resumo:
Cardiogenic shock (CS) has a poor prognosis. The heterogeneity in the mortality through different subgroups suggests that some factors can be useful to perform risk stratification and guide management. We aimed to find predictors of in-hospital mortality in these patients. We analyzed all cases of cardiogenic shock due to medical conditions admitted in our intensive acute cardiovascular care unity from November 2010 till November 2015. Clinical, biochemical and hemodynamic variables were registered, as was the Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) profile at 24 h of CS diagnosis. From a total of 281 patients, 28 died within the first 24 h and were not included in the analysis. A total of 253 patients survived the first 24 h, mean age was 68.8 ± 14.4 years, and 174 (68.8%) were men. Etiologies: acute coronary syndrome 146 (57.7%), acute heart failure 60 (23.7%), arrhythmias 35 (13.8%), and others 12 (4.8%). A total of 91 patients (36.0%) died during hospitalization. We found the following independent predictors of in-hospital mortality: age (odds ratio [OR] 1.032, 95% confidence interval [CI] 1.003–1.062), blood glucose (OR 1.004, 95% CI 1.001–1.008), heart rate (OR 1.014, 95% CI 1.001–1.028), and INTERMACS profile (OR 0.168, 95% CI 0.107–0.266). In patients with CS the INTERMACS profile at 24 h of diagnosis was associated with higher in-hospital mortality. This and other prognostic variables (age, blood glucose, and heart rate) may be useful for risk stratification and to select appropriate medical or invasive interventions.
Resumo:
Since the first clinical use of extracorporeal circulation in the last century [1] by John Gibbon and the first successful mechanical support of the left ventricular function by Forest Dodrill [2], the progress of techniques and technologies has helped to develop minimised systems for extracorporeal circulatory and respiratory support. However, the fact is that, despite the advanced technologies used for extracorporeal support, successful application in order to be benefit a critically ill population requires highly trained and skilled teams. Application of these highly sophisticated techniques in life-saving situations inside and/or outside the operating room is a procedure with certain pitfalls and dangers. The aim of this review is to provide a short overview of the technical aspects of extracorporeal circulation, with a look at the recent literature and clinical experiences focusing on technical as well surgical considerations regarding the urgent and/or emergent usage of a central as well as peripheral extracorporeal system.
Resumo:
32
Resumo:
This is an analysis of the theoretical and practical construction of the methodology of Matrix Support by means of studies on Paideia Support (Institutional and Matrix Support), which is an inter-professional work of joint care in recent literature and official documents of the Unified Health System (SUS). An attempt was made to describe methodological concepts and strategies. A comparative analysis of Institutional Support and Matrix Support was also conducted using the epistemological framework of Field and Core Knowledge and Practices.
Resumo:
Phylogenetic relationships among species of the Myzorhynchella Section of Anopheles (Nyssorhynchus) were investigated using the nuclear ribosomal DNA second internal transcribed spacer (ITS2), the nuclear whitegene and mitochondrial cytochrome oxidase subunit I (COI) regions. The recently described Anopheles pristinus and resurrected Anopheles guarani were also included in the study. Bayesian phylogenetic analyses found Anopheles parvus to be the most distantly related species within the Section, a finding that is consistent with morphology. An. pristinus and An. guarani were clearly resolved from Anopheles antunesi and Anopheles lutzii, respectively. An. lutzii collected in the same mountain range as the type locality were found within a strongly supported clade, whereas individuals from the southern state of Rio Grande do Sul, tentatively identified as An. lutzii based on adult female external morphology, were distinct from An. lutzii, An. antunesi and from each other, and may therefore represent two new sympatric species. A more detailed examination of An. lutzii sensu latoalong its known geographic range is recommended to resolve these anomalous relationships.