965 resultados para carbon paste electrodes
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
A potentiometric sensor constructed from a mixture of 25% (m/m) spinel-type manganese oxide (lambda-MnO2), 50% (m/m) graphite powder and 25% (m/m) mineral oil is used for the determination of lithium ions in a flow injection analysis system. Experimental parameters, such as pH of the carrier solution, flow rate, injection sample volume, and selectivity for Li+ against other alkali and alkaline-earth ions and the response time of this sensor were investigated. The sensor response to lithium ions was linear in the concentration range 8.6 x 10(-5) - 1.0 x 10(-2) mol L-1 with a slope 78.9 +/- 0.3 mV dec(-1) over a wide pH range 7 - 10 (Tris buffer), without interference of other alkali and alkaline-earth metals. For a flow rate of 5.0 mL min(-1) and a injection sample volume of 408.6 muL, the relative standard deviation for repeated injections of a 5.0 x 10(-4) mol L-1 lithium ions was 0.3%.
Resumo:
A mercury-free electrode chemically modified with carbon paste containing dimethylglyoxime was used for determination of nickel in fuel ethanol. The instrumental parameters and composition of the modified paste were optimized. The analytical curve for nickel determination from 5.0 x 10(-9) to 5.0 x10(-7) mol(-1) was obtained using 25 min of accumulation time. The detection limit and amperometric sensitivity obtained for this method were 2.7 x 10 mol(-1) and 5.2 x 10(8) mu A mol(-1) L, respectively. The values for nickel concentration in four commercial samples of fuel ethanol were obtained in the range of 1.1 x 10(-8) to 6.9 x 10(-8) mol(-1). A comparison to graphite furnace atomic absorption spectrometry (GFAAS) was performed for nickel determination in commercial samples of ethanol.
Resumo:
In this communication we report a proof of concept study of the use of cyclic voltammetry with a polyeugenol-modified glassy carbon (GC) electrode to selectively detect L-cysteine in the presence of both DL-homocysteine and glutathione in perchloric acid. The formation of a polyeugenol-modified gold electrode is also reported for the first time.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
The preparation and electrochemical characterization of a carbon paste electrode modified with N.N′-ethylenebis(salicylideneiminato) oxovanadium(IV) complex ([VO(Salen)]) as well as its behavior as electrocatalyst toward the oxidation of dipyrone were investigated. The electrochemical behavior of the modified electrode and the electrooxidation of dipyrone were explored using cyclic voltammetry. The voltammetric response of the modified electrode is based on two reactions. One electrochemical related to the oxidation of the metallic center of the [VO(Salen)] and the other involving the chemical redox process involving the oxidized form of the complex and the reduced form of dipyrone. The best voltammetric response was observed for a paste composition of 25% (m/m) [VO(Salen)], KCl solution pH from 5.5 to 8.0 as the electrolyte and potential scan rate of 10 mV s-1 in the presence of dipyrone. A linear voltammetric response for dipyrone was obtained in the concentration range from 9.9 × 106 to 2.8 × 10 -3 mol L-1, with a detection limit of 7.2 × 10 -6 mol L-1. Among of several compounds tested as potential interference, only ascorbic acid presented some interference. The proposed electrode is useful for the quality control and routine analysis of dipyrone in pharmaceutical formulations.
Resumo:
This work has been carried out in order to determine the copper content in sugar cane spirit samples from the south of Minas Gerais, using a carbon paste electrode modified with ascorbic acid and carbon nanotubes using the square wave voltammetry technique. The following parameters were studied: Ed (deposit potencial). Td (deposit time), f (frequency), A (amplitude) and ΔEs (increment scanning). The analytical curve was built in an interval from 0.5 to 12 mg L-1 and a coefficient of linear correlation of 0.997 Three sugar cane spirit samples were analysed, which presented copper content ranging from 0.29 to 1.59 mg L-1.
Resumo:
An eletroanalytical method for determination of arsenic in sugar cane brandy using an electrode consisting of carbon paste modified with carbon nanotubes (CNTPE) and mineral oil has been developed. The cyclic (CV) and linear sweep voltammetry modes (LSV) with cathodic stripping were employed for CNTPE containing mineral oil. The analytical curves were linear from 30.0 to 80.0 µg L-1 for LSV. The limit of detection (L.O.D.) was 10.45 μg L-1 and limit of quantification (L.O.Q.) was 34.33 μg L-1. The developed method was applied to the determination of arsenic in tree commercial sugar cane brandy samples. The results were in good agreement with those obtained by HGAAS, showing that CNTPE containing mineral oil can be successfully employed to the simultaneous determination of arsenic in sugar cane brandy samples.
Resumo:
In this work we present an electrochemical study using carbon paste electrode (CPE) with CuFeS2 in solutions with different concentrations of Fe2+ ions in order to evaluate the possible interaction between these ions and mineral sulfide in the absence and presence of the bacteria Acidithiobacillus ferroxidans.
Resumo:
With the fast growth of cancer research, new analytical methods are needed to measure anticancer drugs. This is usually accomplished by using sophisticated analytical instruments. Biosensors are attractive candidates for measuring anticancer drugs, but currently few biosensors can achieve this goal. In particular, it is challenging to have a general method to monitor various types of anticancer drugs with different structures. In this work, a biosensor was developed to detect anticancer drugs by modifying carbon paste electrodes with glutathione-s-transferase (GST) enzymes. GST is widely studied in the metabolism of xenobiotics and is a major contributing factor in resistance to anticancer drugs. The measurement of anticancer drugs is based on competition between 1-chloro-2,4-dinitrobenzene (CDNB) and the drugs for the GST enzyme in the electrochemical potential at 0.1 V vs. Ag/AgCl by square wave voltammetry (SWV) or using a colorimetric method. The sensor shows a detection limit of 8.8 mu M cisplatin and exhibits relatively long life time in daily measurements. (C) 2014 Elsevier B.V. All rights reserved.
Resumo:
The work reported here shows a direct experimental comparison of the sensitivities of AlN solidly mounted resonators (SMR)-based biosensors fabricated with standard metal electrodes and with carbon nanotube electrodes. SMRs resonating at frequencies around 1.75 GHz have been fabricated, some devices using a thin film of multi-wall carbon nanotubes (CNTs) as the top electrode material and some identical devices using a chromium/gold electrode. Protein solutions with different concentrations were loaded on the top of the resonators and their responses to mass-load from physically adsorbed coatings were investigated. Results show that resonators using CNTs as the top electrode material exhibited higher frequency change for a given load due to the higher active surface area of a thin film of interconnecting CNTs compared to that of a metal thin film electrode and hence exhibited greater mass loading sensitivity. It is therefore concluded that the use of CNT electrodes on resonators for their use as gravimetric biosensors is viable and worthwhile.
Resumo:
Composites consisting of polyaniline (PANI) coatings inside the microporosity of an activated carbon fibre (ACF) were prepared by electrochemical and chemical methods. Electrochemical characterization of both composites points out that the electrodes with polyaniline show a higher capacitance than the pristine porous carbon electrode. These materials have been used to develop an asymmetric capacitor based on activated carbon (AC) as negative electrode and an ACF–PANI composite as positive electrode in H2SO4 solution as electrolyte. The presence of a thin layer of polyaniline inside the porosity of the activated carbon fibres avoids the oxidation of the carbon material and the oxygen evolution reaction is produced at more positive potentials. This capacitor was tested in a maximum cell voltage of 1.6 V and exhibited high energy densities, calculated for the unpackaged active materials, with values of 20 W h kg−1 and power densities of 2.1 kW kg−1 with excellent cycle lifetime (90% during the first 1000 cycles) and high coulombic efficiency.
Resumo:
The electroanalytical determination of isoprenaline in pharmaceutical preparations of a homemade carbon paste electrode modified with copper(II) hexacyanoferrate(III) (CuHCF) was studied by cyclic voltammetry. Several parameters were studied for the optimization of the sensor such as electrode composition, electrolytic solution, pH effect, potential scan rate and interferences in potential. The optimum conditions were found in an electrode composition (in mass) of 15% CuHCF, 60% graphite and 25% mineral oil in 0.5 mol l(-1) acetate buffer solution at pH 6.0. The analytical curve for isoprenaline was linear in the concentration range from 1.96 x 10(-4) to 1.07 x 10(-3) mol l(-1) with a detection limit of 8.0 x 10(-5) mol l(-1). The relative standard deviation was 1.2% for 1.96 x 10(-4) mol l(-1) isoprenaline solution (n=5). The procedure was successfully applied to the determination of isoprenaline in pharmaceutical preparations; the CuHCF modified carbon paste electrode gave comparable results to those results obtained using a UV spectrophotometric method. (C) 2004 Elsevier B.V. All rights reserved.
Resumo:
The electrochemical behavior of a carbon paste electrode modified (CPEM) with N,N′-ethylenebis(salicylideneiminato)oxovanadium(IV) complex ([(VO)-O-IV(Salen)]) was investigated as a new sensor for cysteine. Cyclic voltammetry at the modified electrode in 0.1 mol L-1 KCl Solution (pH 5.0) showed a single-electron reduction/oxidation of the Couple VO3+/VO2+. The CPEM with [VO(Salen)] presented good electrochemical stability in a wide pH range (4.0-10.0) and an ability to electrooxidate cysteine at 0.65 V versus SCE. These results demonstrate the viability of the use of this modified electrode as an amperometric sensor for cysteine determination. © 2004 Elsevier B.V. All rights reserved.
Resumo:
The growing market of electrical cars, portable electronics, photovoltaic systems..etc. requires the development of efficient, low-cost, and low environmental impact energy storage devices (ESDs) including batteries and supercapacitors.. Due to their extended charge-discharge cycle, high specific capacitance, and power capabilities supercapacitors are considered among the most attractive ESDs. Over the last decade, research and development in supercapacitor technology have accelerated: thousands of articles have been published in the literature describing the electrochemical properties of the electrode materials and electrolyte in addition to separators and current collectors. Carbon-based supercapacitor electrodes materials have gained increasing attention due to their high specific surface area, good electrical conductivity, and excellent stability in harsh environments, as well as other characteristics. Recently, there has been a surge of interest in activated carbon derived from low-cost abundant sources such as biomass for supercapacitor electrode materials. Also, particular attention was given to a major challenging issue concerning the substitution of organic solutions currently used as electrolytes due to their highest electrochemical stability window even though their high cost, toxicity, and flammability. In this regard, the main objective of this thesis is to investigate the performances of supercapacitors using low cost abundant safe, and low environmental impact materials for electrodes and electrolytes. Several prototypes were constructed and tested using natural resources through optimization of the preparation of appropriate carbon electrodes using agriculture by-products waste or coal (i.e. Argan shell or Anthracite from Jerrada). Such electrodes were tested using several electrolyte formulations (aqueous and water in salt electrolytes) beneficing their non-flammability, lower cost, and environmental impact; the characteristics that provide a promising opportunity to design safer, inexpensive, and environmentally friendly devices compared to organic electrolytes.