Sensor for cysteine based on oxovanadium(IV) complex of Salen modified carbon paste electrode
Contribuinte(s) |
Universidade Estadual Paulista (UNESP) |
---|---|
Data(s) |
20/05/2014
25/10/2016
20/05/2014
25/10/2016
13/05/2005
|
Resumo |
The electrochemical behavior of a carbon paste electrode modified (CPEM) with N,N′-ethylenebis(salicylideneiminato)oxovanadium(IV) complex ([(VO)-O-IV(Salen)]) was investigated as a new sensor for cysteine. Cyclic voltammetry at the modified electrode in 0.1 mol L-1 KCl Solution (pH 5.0) showed a single-electron reduction/oxidation of the Couple VO3+/VO2+. The CPEM with [VO(Salen)] presented good electrochemical stability in a wide pH range (4.0-10.0) and an ability to electrooxidate cysteine at 0.65 V versus SCE. These results demonstrate the viability of the use of this modified electrode as an amperometric sensor for cysteine determination. © 2004 Elsevier B.V. All rights reserved. |
Identificador |
Sensors and Actuators B-chemical. Lausanne: Elsevier B.V. Sa, v. 106, n. 2, p. 619-625, 2005. 0925-4005 http://hdl.handle.net/11449/283 http://acervodigital.unesp.br/handle/11449/283 10.1016/j.snb.2004.07.031 WOS:000228969100018 |