48 resultados para biomicroscopy


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To assess the safety and efficacy of transitioning patients whose intraocular pressure (IOP) had been insufficiently controlled on prostaglandin analog (PGA) monotherapy to treatment with travoprost 0.004%/timolol 0.5% fixed combination with benzalkonium chloride (TTFC). Methods: This prospective, multicenter, open-label, historical controlled, single-arm study transitioned patients who had primary open-angle glaucoma, pigment dispersion glaucoma, or ocular hypertension and who required further IOP reduction from PGA monotherapy to oncedaily treatment with TTFC for 12 weeks. IOP and safety (adverse events, corrected distance visual acuity, and slit-lamp biomicroscopy) were assessed at baseline, week 4, and week 12. A solicited ocular symptom survey was administered at baseline and at week 12. Patients and investigators reported their medication preference at week 12. Results: Of 65 patients enrolled, 43 had received prior travoprost therapy and 22 had received prior nontravoprost therapy (n = 18, bimatoprost; n = 4, latanoprost). In the total population, mean IOP was significantly reduced from baseline (P = 0.000009), showing a 16.8% reduction after 12 weeks of TTFC therapy. In the study subgroups, mean IOP was significantly reduced from baseline to week 12 (P = 0.0001) in the prior travoprost cohort (19.0% reduction) and in the prior nontravoprost cohort (13.1% reduction). Seven mild, ocular, treatment-related adverse events were reported. Of the ten ocular symptom questions, eight had numerically lower percentages with TTFC compared with prior PGA monotherapy and two had numerically higher percentages with TTFC (dry eye symptoms and ocular stinging/burning). At week 12, TTFC was preferred over prior therapy for 84.2% of patients (48 of 57) by the patients themselves, and for 94.7% of patients (54 of 57) by their physicians. Conclusion: When TTFC replaced PGA monotherapy in patients whose IOP had been uncontrolled, the outcome was a significant reduction in IOP and an acceptable safety and tolerability profile. Most patients and investigators preferred TTFC to prior PGA monotherapy. © 2012 Costa et al, publisher and licensee Dove Medical Press Ltd.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To observe the frequency of the occurrence of the anophthalmic socket in the Middle West region of the state of São Paulo and to describe the demographic profile of the carriers in a population-based data. Methods: A cross-sectional study involve a random sampling carried out in twelve cities of the Middle West region of the state of São Paulo, for which the reference center is the city of Botucatu was done. The participators were chosen by assortment which considered the houses of these people. It was established a sampling with 11,453 people. All the exams were realized using a Mobile Ophthalmologic Unit. The research protocol included the demographic data and the complete ophthalmologic exam (anamnesis, ocular and systemic antecedents, familiar antecedents, visual acuity with and without correction, tonometry, biomicroscopy, fundoscopy, and refraction exam). All the data were transferred to an Excel spreadsheet and submitted to a descriptive analysis and were presented by the frequency of the occurrence. Results: Ophthalmic socket frequency in the Middle West region of the state of São Paulo was 0.96%. We found 11 cases of anophthalmic socket, with involvement of 0.7 % in females and 1.3 %, male. The most common causes of anophthalmic socket were glaucoma (blind painful eye), microphthalmia, trauma, and endophthalmitis. The majority of the people were 40 years old or more, and we found just one person younger than 19 years old. Conclusion: The anophthalmic socket occurred in 0.96% of the habitants of the Middle West region of São Paulo State, occurring mainly in male and with large variety of the affected ages.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Cirurgia Veterinária - FCAV

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Ocular surface diseases are often diagnosed in brachycephalic dogs. The ophthalmic parameters of the Shih Tzu dogs are evaluated in this study since this breed is among the most commonly affected by these diseases. In this study, ophthalmic parameters of this breed were partly studied under physical restraint. Schirmer tear test, breakup time test, aesthesiometry, biomicroscopy, non-contact specular microscopy, laser flaremetry, applanation tonometry, ultrasonography and ophthalmoscopy were carried in 48 eyes of 24 male and female dogs, aged from two to four years, weighing between 5 and 10kg. All dogs were from a breeding kennel. Descriptive statistics were applied to the data. Mean and standard error for Schirmer tear test was 26.145±0.803mm min-1; breakup time test, 13.668±0.538s; and aesthesiometry, 2.395±0.071cm. The biomicroscopy evaluation showed that 70.83% of the eyes had medial entropion; 42% caruncular trichiasis; 33% distichiasis, 27% mild paracentral corneal opacity; and 13% corneal melanosis. Mean and standard error for endothelial cell density was 2221.591±20.161cells mm-2; endothelial cell hexagonality, 63.770±1.805%; endothelial cell area, 451.895±4.179mm2; central corneal thickness, 0.490±0.007 mm; laser flaremetry, 1.720±0.216PC ms-1; applanation tonometry, 16.118±0.460mmHg; axial length, 20.255±0.134mm; lens thickness, 6.624±0.031mm; anterior chamber, 4.064±0.109mm; and vitreous chamber, 9.565±0.054mm. Ophthalmoscopy findings were not different from previous reports for other breeds. The results showed that the ophthalmic Shih Tzu parameters did not differ from other breeds according to data in the literature, except for the breakup time and Cochet-Bonnet aesthesiometry.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE. To evaluate electrically evoked phosphene thresholds (EPTs) in healthy subjects and in patients with retinal disease and to assess repeatability and possible correlations with common ophthalmologic tests. METHODS. In all, 117 individuals participated: healthy subjects (n = 20) and patients with retinitis pigmentosa (RP, n = 30), Stargardt's disease (STG, n = 14), retinal artery occlusion (RAO, n = 20), nonarteritic anterior ischemic optic neuropathy (NAION, n = 16), and primary open-angle glaucoma (POAG, n = 17). EPTs were determined at 3, 6, 9, 20, 40, 60, and 80 Hz with 5+5-ms biphasic current pulses using DTL electrodes. Subjects were examined twice (test-retest range: 1-6 weeks). An empirical model was developed to describe the current-frequency relationship of EPTs. Visual acuity, visual field (kinetic + static), electrophysiology (RP, RAO, STG: Ganzfeld-electroretinography [ERG]/multifocal-ERG; POAG: pattern-ERG; NAION: VEP), slit-lamp biomicroscopy, fundus examination, and tonometry were assessed. RESULTS. EPTs varied between disease groups (20 Hz: healthy subjects: 0.062 +/- 0.038 mA; STG: 0.102 +/- 0.097 mA; POAG: 0.127 +/- 0.09 mA; NAION: 0.244 +/- 0.126 mA; RP: 0.371 +/- 0.223 mA; RAO: 0.988 +/- 1.142 mA). In all groups EPTs were lowest at 20 Hz. In patients with retinal diseases and across all frequencies EPTs were significantly higher than those in healthy subjects, except in STG at 20 Hz (P = 0.09) and 40 Hz (P = 0.17). Test-retest difference at 20 Hz was 0.006 mA in the healthy group and 0.003-0.04 mA in disease groups. CONCLUSIONS. Considering the fast, safe, and reliable practicability of EPT testing, this test might be used more often under clinical circumstances. Determination of EPTs could be potentially useful in elucidation of the progress of ophthalmologic diseases, either in addition to standard clinical assessment or under conditions in which these standard tests cannot be used meaningfully. (ClinicalTrials.gov number, NCT00804102.) (Invest Ophthalmol Vis Sci. 2012; 53: 7440-7448) DOI:10.1167/iovs.12-9612

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To describe the ophthalmological characteristics in a group of Noonan syndrome patients with proven mutations in the PTPN11 gene. Methods: Thirty-five Noonan syndrome patients with PTPN11 gene mutations underwent ophthalmological exams, which consisted of external inspection, slit-lamp biomicroscopy examination and an ophthalmoscopic examination after instillation of 1.0% tropicamide or 1.0% cyclopentolate. Results: All 35 patients had at least one abnormality upon ophthalmological examination. The eyelid and external eye abnormalities were the prevailing features, followed by prominent corneal nerves on slit-lamp exam. Fundus changes were detected in 8% of the subjects, mainly associated with high myopia. No statistically significant differences were observed among the patients presenting specific mutations in the PTPN11 gene. Conclusions: The current study further supports the finding that ocular symptoms account for a large fraction of the clinical manifestations of NS. Additional characteristics are described here. The roles for the various mutations of PTPN11 in ocular development are yet to be established.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Trabalho Final do Curso de Mestrado Integrado em Medicina, Faculdade de Medicina, Universidade de Lisboa, 2014

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE OF REVIEW: Imaging of the crystalline lens and intraocular lens is becoming increasingly more important to optimize the refractive outcome of cataract surgery, to detect and manage complications and to ascertain advanced intraocular lens performance. This review examines recent advances in anterior segment imaging. RECENT FINDINGS: The main techniques used for imaging the anterior segment are slit-lamp biomicroscopy, ultrasound biomicroscopy, scheimpflug imaging, phakometry, optical coherence tomography and magnetic resonance imaging. They have principally been applied to the assessment of intraocular lens centration, tilt, position relative to the iris and movement with ciliary body contraction. SUMMARY: Despite the advances in anterior chamber imaging technology, there is still the need for a clinical, high-resolution, true anatomical, noninvasive technique to image behind the peripheral iris. © 2007 Lippincott Williams & Wilkins, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: Macular oedema is not directly visible on digital photographs used in screening. Photographic surrogate markers are used to detect patients who may have macular oedema. Evidence suggests that only around 10% of patients with these surrogate markers referred to an ophthalmologist have macular oedema when examined by slit-lamp biomicroscopy. Purpose: The purpose of this audit was to determine how many patients with surrogate markers were truly identified by optical coherence tomography (OCT) as having macular oedema. Method: Data were collected from patients attending digital diabetic retinopathy screening. Patients who presented with surrogate markers for macular oedema also had an OCT scan. The fast macula scan on the Stratus OCT was used and an ophthalmologist reviewed the scans to determine whether macular oedema was present. Results: Out of 66 patients with maculopathy defined as haemorrhages or microaneurysms within one optic disc diameter (DD) of the fovea and visual acuity (VA) worse than 6/9 11 (17%) showed thickening on the OCT, only 4 (6%) had macular oedema. None required laser. Out of 155 patients with maculopathy defined as any exudate within one DD of the fovea or circinate within two DD 45 (29%) showed thickening on the OCT of these 27% required laser. Conclusion: OCT is a useful tool in screening to help identify those who need a true referral to ophthalmology for maculopathy. If exudate is present the chance of having macular oedema and requiring laser treatment is greater than the presence of microaneurysms within one DD and reduced VA.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Improvements in imaging chips and computer processing power have brought major advances in imaging of the anterior eye. Digitally captured images can be visualised immediately and can be stored and retrieved easily. Anterior ocular imaging techniques using slitlamp biomicroscopy, corneal topography, confocal microscopy, optical coherence tomography (OCT), ultrasonic biomicroscopy, computerised tomography (CT) and magnetic resonance imaging (MRI) are reviewed. Conventional photographic imaging can be used to quantify corneal topography, corneal thickness and transparency, anterior chamber depth and lateral angle and crystalline lens position, curvature, thickness and transparency. Additionally, the effects of tumours, foreign bodies and trauma can be localised, the corneal layers can be examined and the tear film thickness assessed. © 2006 The Authors.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To assess the validity and repeatability of objective compared to subjective contact lens fit analysis. Methods: Thirty-five subjects (aged 22.0. ±. 3.0 years) wore two different soft contact lens designs. Four lens fit variables: centration, horizontal lag, post-blink movement in up-gaze and push-up recovery speed were assessed subjectively (four observers) and objectively from slit-lamp biomicroscopy captured images and video. The analysis was repeated a week later. Results: The average of the four experienced observers was compared to objective measures, but centration, movement on blink, lag and push-up recovery speed all varied significantly between them (p <. 0.001). Horizontal lens centration was on average close to central as assessed both objectively and subjectively (p > 0.05). The 95% confidence interval of subjective repeatability was better than objective assessment (±0.128. mm versus ±0.168. mm, p = 0.417), but utilised only 78% of the objective range. Vertical centration assessed objectively showed a slight inferior decentration (0.371. ±. 0.381. mm) with good inter- and intrasession repeatability (p > 0.05). Movement-on-blink was lower estimated subjectively than measured objectively (0.269. ±. 0.179. mm versus 0.352. ±. 0.355. mm; p = 0.035), but had better repeatability (±0.124. mm versus ±0.314. mm 95% confidence interval) unless correcting for the smaller range (47%). Horizontal lag was lower estimated subjectively (0.562. ±. 0.259. mm) than measured objectively (0.708. ±. 0.374. mm, p <. 0.001), had poorer repeatability (±0.132. mm versus ±0.089. mm 95% confidence interval) and had a smaller range (63%). Subjective categorisation of push-up speed of recovery showed reasonable differentiation relative to objective measurement (p <. 0.001). Conclusions: The objective image analysis allows an accurate, reliable and repeatable assessment of soft contact lens fit characteristics, being a useful tool for research and optimisation of lens fit in clinical practice.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Full text: It seems a long time ago now since we were at the BCLA conference. The excellent FIFA World Cup in Brazil kept us occupied over the summer as well as Formula 1, Wimbledon, Tour de France, Commonwealth Games and of course exam paper marking! The BCLA conference this year was held in Birmingham at the International Convention Centre which again proved to be a great venue. The number of attendees overall was up on previous years, and at a record high of 1500 people. Amongst the highlights at this year's annual conference was the live surgery link where Professor Sunil Shah demonstrated the differences in technique between traditional phacoemulsification cataract surgery and femtosecond assisted phacoemulsification cataract surgery. Dr. Raquel Gil Cazorla, a research optometrist at Aston University, assisted in the procedure including calibrating the femtosecond laser. Another highlight for me was the session that I chaired, which was the international session organised by IACLE (International Association of CL Educators). There was a talk by Mirjam van Tilborg about dry eye prevalence in the Netherlands and how it was managed by medical general practitioners (GPs) or optometrists. It was interesting to know that there are only 2 schools of optometry there and currently under 1000 registered optometrists there. It also seems that GPs were more likely to blame CL as the cause for dry eye whereas optometrists who had a fuller range of tests were better at solving the issue. The next part of the session included the presentation of 5 selected posters from around the world. The posters were also displayed in the main poster area but were selected to be presented here as they had international relevance. The posters were: 1. Motivators and Barriers for Contact Lens Recommendation and Wear by Nilesh Thite (India) 2. Contact lens hygiene among Saudi wearers by Dr. Ali Masmaly (Saudi) 3. Trends of contact lens prescribing and patterns of contact lens practice in Jordan by Dr. Mera Haddad (Jordan) 4. Contact Lens Behaviour in Greece by Dr. Dimitra Makrynioti (Greece) 5. How practitioners inform ametropes about the benefits of contact lenses and overcome the potential barriers: an Italian survey, by Dr. Fabrizio Zeri (Italy) It was interesting to learn about CL practice in different parts, for example the CL wearing population ration in Saudi Arabia is around 1:2 Male:Female (similar to other parts of the world) and although the sale of CL is restricted to registered practitioners there are many unregistered outlets, like clothing stores, that flout the rules. In Jordan some older practitioners will still advise patients to use tap water or even saliva! But thankfully the newer generation of practitioners have been educated not to advise this. In Greece one of the concerns was that some practitioners may advise patients to use disposable lenses for longer than they should and again it seems to be the practitioners with inadequate education that would do this. In India it was found that cost was one barrier to using contact lenses but also some practitioners felt that they shouldn’t offer CLs due to cost too. In Italy sensitive eyes and CL care and maintenance were the barriers to CL wear but the motivators were vision and comfort and aesthetics. Finally the international session ended with the IACLE travel award and educator awards presented by IACLE president Shehzad Naroo and BCLA President Andrew Yorke. The travel award went to Wang Ling, Jinling Institute of Technology, Nanjing, China. There were 3 regional Contact Lens Educator of the Year Awards sponsored by Coopervision and presented by Dr. J.C. Aragorn of Coopervision. 1. Asia Pacific Region – Dr. Rajeswari Mahadevan of Sankara Nethralaya Medical Research Foundation, Chennai, India 2. Americas Region – Dr. Sergio Garcia of University of La Salle, Bogotá and the University Santo Tomás, Bucaramanga, Colombia 3. Europe/Africa – Middle East Region: Dr. Eef van der Worp, affiliated with the University of Maastricht, the Netherlands The posters above were just a small selection of those displayed at this year's BCLA conference. If you missed the BCLA conference then you can see the abstracts for all posters and talks in a virtual issue of CLAE very soon. The poster competition was kindly sponsored by Elsevier. The poster winner this year was: Joan Gispets – Corneal and Anterior Chamber Parameters in Keratoconus The 3 runners up were: Debby Yeung – Scleral Lens Central Corneal Clearance Assessment with Biomicroscopy Sarah L. Smith – Subjective Grading of Lid Margin Staining Heiko Pult – Impact of Soft Contact Lenses on Lid Parallel Conjunctival Folds My final two highlights are a little more personal. Firstly, I was awarded Honorary Life Fellowship of the BCLA for my work with the Journal, and I would like to thank the BCLA, Elsevier, the editorial board of CLAE, the reviewers and the authors for their support of my role. My final highlight from the BCLA conference this year was the final presentation of the conference – the BCLA Gold Medal award. The recipient this year was Professor Philip Morgan with his talk ‘Changing the world with contact lenses’. Phil was the person who advised me to go to my first BCLA conference in 1994 (funnily he didn’t attend himself as he was busy getting married!) and now 20 years later he was being honoured with the accolade of being the BCLA Gold Medallist. The date of his BCLA medal addressed was shared with his father's birthday so a double celebration for Phil. Well done to outgoing BCLA President Andy Yorke and his team at the BCLA (including Nick Rumney, Cheryl Donnelly, Sarah Greenwood and Amir Khan) on an excellent conference. And finally welcome to new President Susan Bowers. Copyright © 2014 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: Albinism is a rare genetic disorder of melanin production, which can affect only eyes or simultaneously eyes and skin/hair, resulting respectively in ocular (OA) or oculocutaneous albinism (OCA). Through of a case report of a child with OCA we pretend review ophthalmological manifestations of albinism. Case Report: A girl of West African descent was referenced to our appointment for ophthalmological evaluation of oculocutaneous albinism. Visual acuity was 20/310 OD e 20/630 OS by teller cards. In biomicroscopy, iris hypopigmentation and transillumination was visible, allowing to see spiral vessels and other iris details. Fundoscopy showed a denser and complex choroidal circulation due to lack of pigment in retinal pigment epithelium. Foveal hypoplasia was assumed because foveal pit is not apparent and vessels become less respectful of normal arcade and transverse the macula. Results: Melanin plays an important role in the development of the optic system and it’s absence leads to diverse ocular manifestations, such as: iris hypopigmentation and transillumination , reducted pigmentation of retinal pigment epithelium cells, photoreceptor rod cell deficits, foveal hypoplasia, optic nerve hypoplasia and misrouting of optic nerve at the chiasm, with temporal retina fibers inappropriately routed contralaterally instead of ipsilaterally. Photophobia, nystagmus, reduced visual acuity, color impairment and strabismus are other manifestations usually seen in albinism. Conclusion: Ophthalmologists must be familiar with the specific visual manifestations and needs of these patients. It is essential to correct refractive error to optimize visual acuity. Patients should also be advised to wear tinted glasses and sunblock. In more severely affected children they may benefit of low vision consultation and specialized low vision aids like telescopes.