995 resultados para aerosol-OT
Resumo:
The incidence of over-education is here assessed by applying some standard subjective and objective indicators and a new skill-based indicator of over-education to the national samples of eight European countries in the REFLEX survey. With the exception of Spain, the results reveal that over-education is a minor risk amongst European tertiary graduates. Yet, the contrast between the standard indicators and the skill-based indicator reveals the existence of an over-education of a moderate kind in countries with high tertiary attainment rates (Norway, Finland and Netherlands). Such a type of over-education does not come to the surface when applying the standard indicators. Our results also reveal the importance of higher education differentiation (i.e. field of study and branch of higher education) for understanding the risk of over-education. Graduates from humanistic fields, bachelor courses and vocational colleges are more exposed to over-education, though their disadvantage varies across-nationally to a significant extent.
Resumo:
The use of urinary hexane diamine (HDA) as a biomarker to assess human respiratory exposure to hexamethylene diisocyanate (HDI) aerosol was evaluated. Twenty-three auto body shop workers were exposed to HDI biuret aerosol for two hours using a closed exposure apparatus. HDI exposures were quantified using both a direct-reading instrument and a treated-filter method. Urine samples collected at baseline, immediately post exposure, and every four to five hours for up to 20 hours were analyzed for HDA using gas chromatography and mass spectrometry. Mean urinary HDA (microg/g creatinine) sharply increased from the baseline value of 0.7 to 18.1 immediately post exposure and decreased rapidly to 4.7, 1.9 and 1.1, respectively, at 4, 9, and 18 hours post exposure. Considerable individual variability was found. Urinary HDA can assess acute respiratory exposure to HDI aerosol, but may have limited use as a biomarker of exposure in the workplace. [Authors]
Resumo:
A Knudsen flow reactor has been used to quantify surface functional groups on aerosols collected in the field. This technique is based on a heterogeneous titration reaction between a probe gas and a specific functional group on the particle surface. In the first part of this work, the reactivity of different probe gases on laboratory-generated aerosols (limonene SOA, Pb(NO3)2, Cd(NO3)2) and diesel reference soot (SRM 2975) has been studied. Five probe gases have been selected for the quantitative determination of important functional groups: N(CH3)3 (for the titration of acidic sites), NH2OH (for carbonyl functions), CF3COOH and HCl (for basic sites of different strength), and O3 (for oxidizable groups). The second part describes a field campaign that has been undertaken in several bus depots in Switzerland, where ambient fine and ultrafine particles were collected on suitable filters and quantitatively investigated using the Knudsen flow reactor. Results point to important differences in the surface reactivity of ambient particles, depending on the sampling site and season. The particle surface appears to be multi-functional, with the simultaneous presence of antagonistic functional groups which do not undergo internal chemical reactions, such as acid-base neutralization. Results also indicate that the surface of ambient particles was characterized by a high density of carbonyl functions (reactivity towards NH2OH probe in the range 0.26-6 formal molecular monolayers) and a low density of acidic sites (reactivity towards N(CH3)3 probe in the range 0.01-0.20 formal molecular monolayer). Kinetic parameters point to fast redox reactions (uptake coefficient ?0>10-3 for O3 probe) and slow acid-base reactions (?0<10-4 for N(CH3)3 probe) on the particle surface. [Authors]
Resumo:
Each year, approximately five million people die worldwide from putatively vaccine-preventable mucosally transmitted diseases. With respect to mass vaccination campaigns, one strategy to cope with this formidable challenge is aerosol vaccine delivery, which offers potential safety, logistical, and cost-saving advantages over traditional vaccination routes. Additionally, aerosol vaccination may elicit pivotal mucosal immune responses that could contain or eliminate mucosally transmitted pathogens in a preventative or therapeutic vaccine context. In this current preclinical non-human primate investigation, we demonstrate the feasibility of aerosol vaccination with the recombinant poxvirus-based vaccine vectors NYVAC and MVA. Real-time in vivo scintigraphy experiments with radiolabeled, aerosol-administered NYVAC-C (Clade C, HIV-1 vaccine) and MVA-HPV vaccines revealed consistent mucosal delivery to the respiratory tract. Furthermore, aerosol delivery of the vaccines was safe, inducing no vaccine-associated pathology, in particular in the brain and lungs, and was immunogenic. Administration of a DNA-C/NYVAC-C prime/boost regime resulted in both systemic and anal-genital HIV-specific immune responses that were still detectable 5 months after immunization. Thus, aerosol vaccination with NYVAC and MVA vectored vaccines constitutes a tool for large-scale vaccine efforts against mucosally transmitted pathogens.
Resumo:
Benjamín de Tudela (en hebreo Biniamín ben rabbí Yonah mi- Tudela) es, sin duda, un navarro universal. Judío de la aljama tudelana, se ignora la fecha de su nacimiento (acaso hacia 1130). Hijo de rabino y viajero infatigable, sólo sabemos de este personaje lo poco que de él se menciona en su famoso Libro de Viajes o Séfer-masa`ot, fruto de sus vivas experiencias -las más de las veces directas- exquisitamente plasmadas en su relación de viaje, redactadas en hebreo. Conocedor del romance navarro vernáculo de la época, sabía hebreo - su lengua de instrucción y cultivo literario- y árabe, entendiendo acaso el griego y el latín.
Resumo:
New products available for food creations include a wide variety of "supposed" food grade aerosol sprays. However, the gas propellants used cannot be considered as safe. The different legislations available did not rule any maximum residue limits, even though these compounds have some limits when used for other food purposes. This study shows a preliminary monitoring of propane, butane and dimethyl ether residues, in cakes and chocolate after spraying, when these gases are used as propellants in food aerosol sprays. Release kinetics of propane, butane and dimethyl ether were measured over one day with sprayed food, left at room temperature or in the fridge after spraying. The alkanes and dimethyl ether analyses were performed by headspace-gas chromatography-mass spectrometry/thermal conductivity detection, using monodeuterated propane and butane generated in situ as internal standards. According to the obtained results and regardingthe extrapolations of the maximum residue limits existing for these substances, different delays should be respected according to the storage conditions and the gas propellant to consume safely the sprayed food.
Resumo:
The complex chemical and physical nature of combustion and secondary organic aerosols (SOAs) in general precludes the complete characterization of both bulk and interfacial components. The bulk composition reveals the history of the growth process and therefore the source region, whereas the interface controls--to a large extent--the interaction with gases, biological membranes, and solid supports. We summarize the development of a soft interrogation technique, using heterogeneous chemistry, for the interfacial functional groups of selected probe gases [N(CH(3))(3), NH(2)OH, CF(3)COOH, HCl, O(3), NO(2)] of different reactivity. The technique reveals the identity and density of surface functional groups. Examples include acidic and basic sites, olefinic and polycyclic aromatic hydrocarbon (PAH) sites, and partially and completely oxidized surface sites. We report on the surface composition and oxidation states of laboratory-generated aerosols and of aerosols sampled in several bus depots. In the latter case, the biomarker 8-hydroxy-2'-deoxyguanosine, signaling oxidative stress caused by aerosol exposure, was isolated. The increase in biomarker levels over a working day is correlated with the surface density N(i)(O3) of olefinic and/or PAH sites obtained from O(3) uptakes as well as with the initial uptake coefficient, γ(0), of five probe gases used in the field. This correlation with γ(0) suggests the idea of competing pathways occurring at the interface of the aerosol particles between the generation of reactive oxygen species (ROS) responsible for oxidative stress and cellular antioxidants.
Resumo:
PURPOSE: Unlike in the outpatient setting, delivery of aerosols to critically ill patients may be considered complex, particularly in ventilated patients, and benefits remain to be proven. Many factors influence aerosol delivery and recommendations exist, but little is known about knowledge translation into clinical practice. METHODS: Two-week cross-sectional study to assess the prevalence of aerosol therapy in 81 intensive and intermediate care units in 22 countries. All aerosols delivered to patients breathing spontaneously, ventilated invasively or noninvasively (NIV) were recorded, and drugs, devices, ventilator settings, circuit set-up, humidification and side effects were noted. RESULTS: A total of 9714 aerosols were administered to 678 of the 2808 admitted patients (24 %, CI95 22-26 %), whereas only 271 patients (10 %) were taking inhaled medication before admission. There were large variations among centers, from 0 to 57 %. Among intubated patients 22 % (n = 262) received aerosols, and 50 % (n = 149) of patients undergoing NIV, predominantly (75 %) inbetween NIV sessions. Bronchodilators (n = 7960) and corticosteroids (n = 1233) were the most frequently delivered drugs (88 % overall), predominantly but not exclusively (49 %) administered to patients with chronic airway disease. An anti-infectious drug was aerosolized 509 times (5 % of all aerosols) for nosocomial infections. Jet-nebulizers were the most frequently used device (56 %), followed by metered dose inhalers (23 %). Only 106 (<1 %) mild side effects were observed, despite frequent suboptimal set-ups such as an external gas supply of jet nebulizers for intubated patients. CONCLUSIONS: Aerosol therapy concerns every fourth critically ill patient and one-fifth of ventilated patients.