996 resultados para Variable practice


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The usual practice in using a control chart to monitor a process is to take samples of size n from the process every h hours. This article considers the properties of the X̄ chart when the size of each sample depends on what is observed in the preceding sample. The idea is that the sample should be large if the sample point of the preceding sample is close to but not actually outside the control limits and small if the sample point is close to the target. The properties of the variable sample size (VSS) X̄ chart are obtained using Markov chains. The VSS X̄ chart is substantially quicker than the traditional X̄ chart in detecting moderate shifts in the process.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Polymeric insulation is an increasing tendency in projects and maintenance of electrical networks for power distribution and transmission. Electrical power devices (e. g., insulators and surge arresters) developed by using polymeric insulation presents many advantages compared to the prior power components using ceramic insulation, such as: a better performance under high pollution environment; high hydrophobicity; high resistance to mechanical, electrical and chemical stresses. The practice with silicone insulators in polluted environments has shown that the ideal performance is directly related to insulator design and polymer formulation. One of the most common misunderstandings in the design of silicone compounds for insulators is the amount of inorganic load used in their formulation. This paper attempts to clarify how the variation of the inorganic load amount affects physicochemical characteristics of different silicone compounds. The physicochemical evaluation is performed from several measurements, such as: density, hardness, elongation, tensile strength. In addition, the evaluation of the physicochemical structure is carried out using infrared test and scanning electronic microscopy (SEM). The electrical analysis is performed from the electric tracking wheel and erosion test, in agreement with the recommendation of the International Electrotechnical Commission (IEC). (C) 2014 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES: To describe noninvasive positive-pressure ventilation use in intensive care unit clinical practice, factors associated with NPPV failure and the associated prognosis. METHODS: A prospective cohort study. RESULTS: Medical disorders (59%) and elective surgery (21%) were the main causes for admission to the intensive care unit. The main indications for the initiation of noninvasive positive-pressure ventilation were the following: post-extubation, acute respiratory failure and use as an adjunctive technique to chest physiotherapy. The noninvasive positive-pressure ventilation failure group was older and had a higher Simplified Acute Physiology Score II score. The noninvasive positive-pressure ventilation failure rate was 35%. The main reasons for intubation were acute respiratory failure (55%) and a decreased level of consciousness (20%). The noninvasive positive-pressure ventilation failure group presented a shorter period of noninvasive positive-pressure ventilation use than the successful group [three (2-5) versus four (3-7) days]; they had lower levels of pH, HCO3 and base excess, and the FiO(2) level was higher. These patients also presented lower PaO2:FiO2 ratios; on the last day of support, the inspiratory positive airway pressure and expiratory positive airway pressure were higher. The failure group also had a longer average duration of stay in the intensive care unit [17 (10-26) days vs. 8 (5-14) days], as well as a higher mortality rate (9 vs. 51%). There was an association between failure and mortality, which had an odds ratio (95% CI) of 10.6 (5.93 - 19.07). The multiple logistic regression analysis using noninvasive positive pressure ventilation failure as a dependent variable found that treatment tended to fail in patients with a Simplified Acute Physiology Score II >= 34, an inspiratory positive airway pressure level >= 15 cmH2O and pH<7.40. CONCLUSION: The indications for noninvasive positive-pressure ventilation were quite varied. The failure group had a longer intensive care unit stay and higher mortality. Simplified Acute Physiology Score II >= 34, pH<7.40 and higher inspiratory positive airway pressure levels were associated with failure.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The diagnosis of a periprosthetic joint infection (PJI) can be challenging, either because of the variable clinical presentation or because of previous antimicrobial treatment interfering with the detection of the pathogen. In recent years, various means to diagnose PJI have been analyzed. These include invasive and non-invasive laboratory tests, imaging procedures, and novel techniques such as sonication of implants and the use of molecular microbiology. In this review, both established and novel diagnostic procedures are presented. An algorithm for detecting PJI in patients with acute and chronic symptoms is proposed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper reports on an exploration of the concept of 'supervision' as applied to allied health professionals within a large mental health service in one Australian State. A two-part methodology was used, with focus group interviews conducted with allied health professionals, and semi-structured telephone interviews with service managers. Fifty-eight allied health professionals participated in a series of seven focus groups. Semi-structured interviews were conducted with the Directors or Managers of mental health services in all 21 regions in the state. Allied health professionals and service managers both considered supervision to be an important mechanism for ensuring staff competence and best practice outcomes for consumers and carers. There was strong endorsement of the need for clarification and articulation of supervision policies within the organization, and the provision of appropriate resourcing to enable supervision to occur. Current practice in supervision was seen as ad hoc and of variable standard; the need for training in supervision was seen as critical. The supervision needs of newly graduated allied health professionals and those working in rural and regional areas were also seen as important. The need for a flexible and accessible model of supervision was clearly demonstrated.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pain management in premature and sick babies has long been recognisedas a vital component of neonatal care; however practices pertaining to painassessment and administration of analgesia remain variable in Neonatal Units(NNU). Sucrose has been identified as an effective agent in reducing pain during minorpainful procedures in premature babies but the uptake has been modest.This article (part 2) follows on from an earlier article on evidence to support theimplementation of sucrose administration as a measure for pain relief for minorprocedures (part 1) and will centre on practice-based change in the NNU and reflecton the strategies used as well as the effectiveness of the proposed change. A theoreticalchange model will be used as a framework to help unpack the influencesinherent within the change process.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES: To describe changes in the use of intravenous (IV) fluid by quantity and type in different regions of Australia and New Zealand. DESIGN, SETTING AND PARTICIPANTS: We conducted a retrospective ecological study examining regional and temporal trends in IV fluid consumption across Australia and New Zealand over the periods 2012-2013 and 2013- 2014, using national proprietary sales data as a surrogate for consumption, and demographic data from the public domain. RESULTS: More than 13.3 million litres of IV fluid were consumed in Australia and New Zealand in 2012-2013, and more than 13.9 million litres in 2013-2014, with colloid solutions accounting for < 2%. There was marked regional variation in consumption of fluids, by volumes and proportions used, when standardised to overall Australian and New Zealand values. There was no significant change in the overall volume of crystalloid solutions consumed but there was a significant decrease (9%; P = 0.02) in the ratio of unbalanced to balanced crystalloid solutions consumed. Consumption of all forms of colloid solutions decreased, with a 12% reduction overall (P = 0.02), primarily driven by a 67% reduction in the consumption of hydroxyethyl starch (HES) solutions. CONCLUSIONS: The amount and type of IV fluid use, as determined by fluid sales, is highly variable across Australia and New Zealand. However, overall use of balanced crystalloid solutions is increasing and the use of HES has decreased dramatically.