612 resultados para Tanques acoplados


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present study aimed to compare the main zootechnical and economic indicators of farming tilapia in superintensive system developed in two different net cages dimensions: 6 and 18 m(3). Were used 12,960 juveniles male reversed Nile tilapia (Oreochromis niloticus), strain supreme, with an initial average weight of 32.0 g (+/- 0.85) for 6 m(3) net cages and 88.5 g (+/- 0.96) for 18 m(3) net cages. The fish were fed three times a day with commercial extruded ration, crude protein levels from 40 to 32%, particle size from 2 to 8 mm and daily feeding rate starting with 8% of live weight (LW), decreasing up to 1% LW. It was conclued that, although no statistical difference in most indicators zootechnical (P>0.05), the production of tilapias in bigger net cages resulted in lower average total cost and higher rentability per kg of fish produced, 34.4% higher, resulting in better profitability.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A maioria das instalações de abastecimento de água utiliza bombas hidráulicas do tipo turbobombas, requerendo que o interior de sua carcaça e da tubulação de sucção esteja preenchido com água (escorvados) para que a sucção da água possa ser efetivada. O escorvamento das bombas pode ser efetuado instalando-as abaixo do reservatório de captação (bomba afogada). Quando a bomba está acima do reservatório e o escorvamento é manual, é necessário usar válvulas-de-pé, que são suscetíveis ao mau funcionamento, limitando a confiabilidade do sistema, principalmente em caso de automação. Como alternativa à válvula-de-pé, neste trabalho, foram estudados dois tanques escorva, testados no Laboratório de Hidráulica e Irrigação da FCAV/UNESP - Jaboticabal, avaliando-se situações de altura manométrica de sucção de bomba centrífuga e relações entre volume útil do tanque e volume do tubo de sucção, tendo-se concluído: a) o volume do tanque de escorva é função do volume do tubo de sucção da instalação de bombeamento e da altura manométrica de sucção; b) o volume do tanque de escorva pode ser calculado seguindo-se a Lei de Boyle, com percentagem de acréscimo que, neste estudo, foi de 10% para um modelo de tanque e de 30% para o segundo modelo.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Only 32% of the population of Natal is attended by sewage, while the remaining population use pits and septic tanks. The characterization of the contents of septic tanks and pits contributes to the performance of such system and may guide the decision on treatment of these contents. The main of this research is to characterize the contents of interior residential pits and septic tanks in the greater Natal, with the following specific goals: to develop and manufacture a sampler capable of collecting a representative sample of the entire column (the surface scum, the clarified liquid and sludge bottom); to compare the contents of the tanks with the pits; to compare the contents of the septage from vacuum trucks; to relate the composition content with socioeconomic characteristics of households; to compare the content in both chambers of the septic tanks in series; to assess the situation of the content before and six months after the cleanness; and ultimately propose a pilot scale plant for treatment of septage. Once the sampler was developed, samples were collected within 14 septic tanks and 10 pits in many districts of Natal. Medians of the 24 systems were obtained: temperature, pH, conductivity, oil and grease, total solids, total suspended solids and sediments of 28.0 °C, 6.95; 882 mS/cm, 75.2 mg/L; 10,169 mg/L, 6,509 mg/L and 175 mL/L respectively; 111.0 mgN/L for ammonia, 130.5 mgN/ L for organic nitrogen, 0.2 mgN/L for nitrite, 0.4 mg/L for nitrate; 8935 mgO2/L for COD, 29.2 mgP/L for total phosphorus, thermotolerant coliforms from 9.95 E +06 CFU/100mL helminth eggs and 9.2 eggs/L with a maximum concentration of 688 eggs/L and minimum of 0 eggs/L. Medians of organic nitrogen and TKN were significantly different between groups of tanks and pits. The systems with cleanness gap from 11 and 20 years presented the higher concentrations for most variables. The effluent from the toilets and bathrooms participate more effectively in contributing fractions of solids, alkalinity, nitrogen, COD, total phosphorus, thermotolerant coliforms and helminth eggs. The systems used by socioeconomics class with income from R$ 3,700.00 to R$ 7,600.00, presented higher concentrations for COD, nitrogen, solids and helminth eggs. The first of the two chambers had always presented higher concentrations over the second compartment. The analysis of variance for most variables, showed that the values of septic tanks, pits and septage from vacuum trucks belong to the same group. In the samples taken after cleanness, the median of pH and temperature increased, while alkalinity, COD, organic nitrogen, total phosphorus, ammonia and helminth eggs decreased. The oils and greases and thermotolerant coliforms had slightly varied due to the continuous release of sewage into the systems that maintained their steady state concentrations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The sludge generated in stabilization ponds can be designed for various purposes, among them we mention agricultural use, recovery of degraded areas and civil construction. The choice of these alternatives should be made based on qualitative and quantitative characteristics of the sludge. In this context, this study characterized the digested sludge from an anaerobic lagoon in Cidade do Natal/RN, which deals exclusively with residues of depleted septic tanks and pits. The sludge showed levels of macro and micronutrients that confirm its potential for agriculture, with 139.49 g.kg -1 organic matter, 15.40 g.kg-1 nitrogen and metal concentrations below those required by Resolution No. 375/06 of CONAMA, besides the absence of fecal coliform and less than 0.15 viable helminthes eggs/g, on average. The particle size distribution showed that most of the particles have a diameter similar to the sand, allowing the replacement of this input, for example. Analysis of the leachate and of the sludge solubilized classified as non-inert and non-hazardous according to NBR 10.004/04. The volume produced in three years of operation by the pond was 1903.50m³, equivalent to approximately 400 kg of dry sludge. Overall, the concentrations of the parameters were similar to literature, although none of them addresses sludge anaerobic pond treating sewer from septic tanks and pits.The sludgepresents technical feasibility to various types of use, however the cost of dewatering and especially with transport can derail it. It needs to be made a more thorough study of the costs to prove its economic viability

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We studied the spin waves modes that can propagate in magnetic multilayers composed of ferromagnetic metallic films in the nanometer scale. The ferromagnetic films (iron) are separated and coupled through the nonmagnetic spacer films (chromium). The films that make up the multilayer are stacked in a quasiperiodic pattern, following the Fibonacci and double period sequences. We used a phenomenological theory taking into account: the Zeeman energy (between the ferromagnetic films and the external magnetic field), the energy of the magneto-crystalline anisotropy (present in the ferromagnetic films), the energy of the bilinear and biquadratic couplings (between the ferromagnetic films) and the energy of the dipole-dipole interaction (between the ferromagnetic films), to describe the system. The total magnetic energy of the system is numerically minimized and the equilibrium angles of the magnetization of each ferromagnetic film are determined. We solved the equation of motion of the multilayer to find the dispersion relation for the system and, as a consequence, the spin waves modes frequencies. Our theoretical results show that, in the case of trilayers (Fe/Cr/Fe), our model reproduces with excellent agreement experimental results of Brillouin light scattering, known from the literature, by adjusting the physical parameters of the nanofilms. Furthermore, we generalize the model to N ferromagnetic layers which allowed us to determine how complex these systems become when we increase the number of components. It is worth noting that our theoretical calculations generalize all the results known from the literature

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Intensive production of tilápias, in cages or net tanks, has been proposed as an alternative to increase fish production, that would generate income and offer animal protein in different tropical and subtropical countries. However, this system of production enriches the aquatic environment with nutrients, principally nitrogen and phosphor derived from the dejections of the metabolism of food and eventual food surpluses consumed by the fishes; the alimentation of the fishes in this production modality is dependent on fish food. The emission of these nutritions in levels above the limit that the system is capable metabolize can provoke a phenomenon called eutrofization, putting in risk the quality of water for public and for fish production activities. In this context the work had as a goal to evaluate the trófico state of the four reservoirs for intensive production of tilapias in net-tanks, in other words, he maximum fish production that the reservoirs are able to hold, keeping the desired quantity of nutrient concentrations in water for public use. The results of the four ecosystems in the Boqueirão de Parelhas reservoir showed that it s possible to have an intensive production of tilapias in net tanks, in this environment the annual average concentration of phosphor, was below the considered critical limits to deflagrate the process of eutrofization in semi-arid regions. The carrying capacity of the Boqueirão de Parelhas reservoir depends on the conversion of the feeding facts and phosphor content in the food but it should vary between 100 and 300 tons per year over a variation in the conversion feeding factor of 1,7 to 2,0:1 and a variation in the P in the food of 0,7 to 0,9%

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Avaliou-se o desempenho de tilápias-do-nilo (Oreochromis niloticus) criadas em tanques-rede e alimentadas com dietas contendo 27,0 (controle); 25,2; 24,3 e 22,7% de proteína digestível. Aminoácidos cristalinos (L-lisina, DL-metionina e L-treonina) foram adicionados à dieta considerando o conceito de proteína ideal e simulando o perfil de aminoácidos da dieta controle. Os peixes (34,63±19 g) foram alimentados manualmente com dietas isoenergéticas (3.075 kcal de energia digestível/kg de dieta) até saciedade aparente, três vezes ao dia, durante 91 dias. Utilizou-se um delineamento inteiramente casualizado, com quatro tratamentos, três repetições e 25 peixes/unidade experimental. Não foram observados efeitos dos níveis de proteína digestível sobre o ganho de peso, a conversão alimentar, a taxa de eficiência protéica, o peso da carcaça eviscerada, o rendimento de carcaça, o peso e o rendimento de filé, a sobrevivência e o hematócrito. Houve efeito quadrático dos níveis de proteína digestível sobre o consumo; o maior valor foi estimado para a dieta contendo 24,41% de proteína digestível e excreção de nitrogênio, na qual o melhor resultado estimado foi obtido com peixes que receberam a dieta contendo 24,92% de PD. Com a redução nos níveis de proteína digestível, observou-se aumento linear na retenção de nitrogênio. É possível reduzir o nível de proteína digestível, de 27 (29,1% de PB) para 24,3% (26,6% de PB), em dietas para tilápias-do-nilo criadas em tanques-rede. Essa redução deve ser feita por meio da suplementação de aminoácidos (com base no conceito de proteína ideal), considerando o desempenho e o custo da dieta/kg ganho em filé.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A produção de peixes em tanques-rede no Brasil tem aumentado nas últimas décadas. O baixo investimento inicial e o potencial hídrico representado pela enorme quantidade de água represada em nosso País têm atraído o interesse de empresários para essa atividade. O objetivo desse trabalho foi gerar informações sobre o efeito da densidade de estocagem no crescimento e produtividade da tilápia vermelha da Flórida criadas em tanques-rede. Foram instalados doze tanques-rede de 5 m3, numa represa de 1 ha, e estocados com 25, 50, 75 e 100 tilápias vermelhas da Flórida revertidas por m3. Os peixes foram alimentados com rações extrusadas comerciais contendo 32 e 28% PB por 253 dias. As temperaturas máxima, mínima e média da água foram 32,2, 16,0 e 23,9 C, respectivamente. Também foram monitorados a condutividade (58 mS/cm2), alcalinidade total (28 mg/L), amônia não ionizada (0,26 mg/L), nitrito (0,02 mg/L), oxigênio dissolvido (4,1 mg/L) e transparência da água (37 cm). Foram determinados o peso médio final (279,54g), comprimento padrão médio final (18,72cm), fator de condição (4,12), conversão alimentar aparente (3,15), taxa de sobrevivência (96,9%), ganho de peso diário (0,92g), taxa de crescimento específico (0,70%) e coeficientes de variação do peso (0,357%), do comprimento padrão (0,136%) e do fator de condição (0,136%). Não foram observadas diferenças significativas (P>0,05) entre as densidades de estocagem testadas nesses parâmetros. A densidade de estocagem de 100 peixes/m3 proporcionou a maior biomassa por m3 (P<0,001).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to evaluate the zootechnical performance and chemical composition of jundia juveniles Rhandia voulezi fed with mash, pelletized and extruded diets and cultivated in cages. One hundred and fifty fish were distributed in fifteen cages (0.20 m3), arranged in cages (5m3), in the hydroelectric plant of Governador José Richa, in Iguaçu River (Paraná-Brazil). The fish were fed five times a day, with mash, pelletized and extruded diets, containing 30% of protein and 3250 Kcal/kg of digestible energy/kg. At the end of 60 days, significant differences (p<0.05) were observed on fish performance. The fish that were fed with pelletized diet, presented higher average of final weight (44.08g), final length (16.51cm) and weight gain (36.65g). The different processes did not influence fish survival. The averages of protein and mineral matter of carcass chemical composition did not differ statistically (p<0.05), while the values of humidity and lipideos presented differences among treatments. The highest average of lipideos (8.59%) was observed in peletized diet. The mash diet provided fish with lower lipideo (5.45%) and higher humidity (75.98%) rates. A pelleted diet is most suitable for juvenile catfish R. voulezi cultivation in cages.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To compare the removal efficiency of solids, turbidity and apparent color between a conventional and a column settling tanks in a recirculating aquaculture system (RAS) for tilapia farming. Materials and methods. Tilapia with a stocking density between 30 and 33 kg/m3 were cultured in a RAS consisting of a water level control box, PVC piping system, three plastic tanks for culture, conventional horizontal flow settling tank (Con.ST), column vertical flow settling tank (Col.ST), three phase fluidized bed reactor, oxygen transfer reactor, air compressor, air blower, centrifugal pump. The Con.ST operated at a volume of 1.4 m3 and hydraulic retention time (HRT) of 2.94 h; and was drained weekly for washing and sludge collection, representing a 55%discharge of system water volume. The Col.ST operated with a volume of 0.30 m3 and HRT of 0.553 h. Three daily partial draining operations were executed, representing a discharge of 50% of the system volume. Results. The mean solids removal efficiencies were: 34.01 and 44.44%for total solids; 64.45 and 71.71% for suspended solids; 21.10 and 45.65% volatile solids; 65.51% and 62.79% for turbidity; and 56.37 and 50.91% for apparent color, respectively for Con.ST and Col.ST. Conclusions. The two settling devices are useful on removal of the studied parameters and presented similar performance on turbidity and apparent color removal; however, the Col.ST was more efficient than Con.ST for solids removal, requires less space, less volume and requires less discharge water volume, displaying feasibility for its use on RAS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)