994 resultados para Similar tests


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Resumen tomado de la publicaci??n

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Consistency of performance across tasks that assess syntactic comprehension in aphasia has clinical and theoretical relevance. In this paper we add to the relatively sparse previous work on how sentence comprehension abilities are influenced by the nature of the assessment task. Aims: Our aims are: (1) to compare linguistic performance across sentence-picture matching, enactment, and truth-value judgement tasks; (2) to investigate the impact of pictorial stimuli on syntactic comprehension. Methods Procedures: We tested a group of 10 aphasic speakers (3 with fluent and 7 with non-fluent aphasia) in three tasks (Experiment 1): (i) sentence-picture matching with four pictures, (ii) sentence-picture matching with two pictures, and (iii) enactment. A further task of truth-value judgement was given to a subgroup of those speakers (n=5, Experiment 2). Similar sentence types across all tasks were used and included canonical (actives, subject clefts) and non-canonical (passives, object clefts) sentences. We undertook two types of analyses: (a) we compared canonical and non-canonical sentences in each task; (b) we compared performance between (i) actives and passives, (ii) subject and object clefts in each task. We examined the results of all participants as a group and as case-series. Outcomes Results: Several task effects emerged. Overall, the two-picture sentence-picture matching and enactment tasks were more discriminating than the four-picture condition. Group performance in the truth-value judgement task was similar to two-picture sentence-picture matching and enactment. At the individual level performance across tasks contrasted to some group results. Conclusions: Our findings revealed task effects across participants. We discuss reasons that could explain the diverse profiles of performance and the implications for clinical practice.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The present study aims to evaluate the probiotic potential of lactic acid bacteria (LAB) isolated from naturally fermented olives and select candidates to be used as probiotic starters for the improvement of the traditional fermentation process and the production of newly added value functional foods. Seventy one (71) lactic acid bacterial strains (17 Leuconostoc mesenteroides, 1 Ln. pseudomesenteroides, 13 Lactobacillus plantarum, 37 Lb. pentosus, 1 Lb. paraplantarum, and 2 Lb. paracasei subsp. paracasei) isolated from table olives were screened for their probiotic potential. Lb. rhamnosus GG and Lb. casei Shirota were used as reference strains. The in vitro tests included survival in simulated gastrointestinal tract conditions, antimicrobial activity (against Listeria monocytogenes, Salmonella Enteritidis, Escherichia coli O157:H7), Caco-2 surface adhesion, resistance to 9 antibiotics and haemolytic activity. Three (3) Lb. pentosus, 4 Lb. plantarum and 2 Lb. paracasei subsp. paracasei strains demonstrated the highest final population (>8 log cfu/ml) after 3 h of exposure at low pH. The majority of the tested strains were resistant to bile salts even after 4 h of exposure, while 5 Lb. plantarum and 7 Lb. pentosus strains exhibited partial bile salt hydrolase activity. None of the strains inhibited the growth of the pathogens tested. Variable efficiency to adhere to Caco-2 cells was observed. This was the same regarding strains' susceptibility towards different antibiotics. None of the strains exhibited β-haemolytic activity. As a whole, 4 strains of Lb. pentosus, 3 strains of Lb. plantarum and 2 strains of Lb. paracasei subsp. paracasei were found to possess desirable in vitro probiotic properties similar to or even better than the reference probiotic strains Lb. casei Shirota and Lb. rhamnosus GG. These strains are good candidates for further investigation both with in vivo studies to elucidate their potential health benefits and in olive fermentation processes to assess their technological performance as novel probiotic starters.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study determined the sensory shelf life of a commercial brand of chocolate and carrot cupcakes, aiming at increasing the current 120 days of shelf life to 180. Appearance, texture, flavor and overall quality of cakes stored at six different storage times were evaluated by 102 consumers. The data were analyzed by analysis of variance and linear regression. For both flavors, the texture presented a greater loss in acceptance during the storage period, showing an acceptance mean close to indifference on the hedonic scale at 120 days. Nevertheless, appearance, flavor and overall quality stayed acceptable up to 150 days. The end of shelf life was estimated at about 161 days for chocolate cakes and 150 days for carrot cakes. This study showed that the current 120 days of shelf life can be extended to 150 days for carrot cake and to 160 days for chocolate cake. However, the 180 days of shelf life desired by the company were not achieved. PRACTICAL APPLICATIONS This research shows the adequacy of using sensory acceptance tests to determine the shelf life of two food products (chocolate and carrot cupcakes). This practical application is useful because the precise determination of the shelf life of a food product is of vital importance for its commercial success. The maximum storage time should always be evaluated in the development or reformulation of new products, changes in packing or storage conditions. Once the physical-chemical and microbiological stability of a product is guaranteed, sensorial changes that could affect consumer acceptance will determine the end of the shelf life of a food product. Thus, the use of sensitive and reliable methods to estimate the sensory shelf life of a product is very important. Findings show the importance of determining the shelf life of each product separately and to avoid using the shelf time estimated for a specific product on other, similar products.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We have investigated if a new LEDs system has enough efficient energy to promote efficient shear and tensile bonding strength resistance under standardized tests. LEDs 470 +/- 10 nm can be used to photocure composite during bracket fixation. Advantages considering resistance to tensile and shear bonding strength when these systems were used are necessary to justify their clinical use. Forty eight human extracted premolars teeth and two light sources were selected, one halogen lamp and a LEDs system. Brackets for premolar were bonded through composite resin. Samples were submitted to standardized tests. A comparison between used sources under shear bonding strength test, obtained similar results; however, tensile bonding test showed distinct results: a statistical difference at a level of 1% between exposure times (40 and 60 seconds) and even to an interaction between light source and exposure time. The best result was obtained with halogen lamp use by 60 seconds, even during re-bonding; however LEDs system can be used for bonding and re-bonding brackets if power density could be increased.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

CONTEXTO E OBJETIVO: A falta de consenso sobre os protocolos de rastreamento e diagnóstico do diabetes gestacional, associada às dificuldades na realização do teste oral simplificado do diabete gestacional (o teste de tolerância a 100 g de glicose, considerado padrão-ouro) justificam a comparação com alternativas. O objetivo deste trabalho é comparar o teste padrão-ouro a dois testes de rastreamento: associação de glicemia de jejum e fatores de risco (GJ + FR) e o teste oral simplificado de tolerância a 50 g de glicose (TTG 50 g), com o teste de tolerância a 100 g de glicose (TTG 100 g). TIPO DE ESTUDO E LOCAL: Estudo de coorte longitudinal, prospectivo, realizado no Serviço de Ginecologia e Obstetrícia do Hospital Universitário da Universidade Federal de Mato Grosso do Sul. MÉTODOS: 341 gestantes foram submetidas aos três testes. Calcularam-se os índices de sensibilidade (S), especificidade (E), valores preditivos (VPP e VPN), razões de probabilidade (RPP e RPN) e resultados falsos (FP e FN), positivos e negativos da associação GJ + FR e do TTG 50 g em relação ao TTG 100 g. Compararam-se as médias das glicemias de uma hora pós-sobrecarga (1hPS) com 50 e 100 g. Na análise estatística, empregou-se o teste t de Student, com limite de significância de 5%. RESULTADOS: A associação GJ + FR encaminhou mais gestantes (53,9%) para a confirmação diagnóstica que o TTG 50 g (14,4%). Os dois testes foram equivalentes nos índices de S (86,4 e 76,9%), VPN (98,7 e 98,9%), RPN (0,3 e 0,27) e FN (15,4 e 23,1%). As médias das glicemias 1hPS foram semelhantes, 106,8 mg/dl para o TTG 50 g e 107,5 mg/dl para o TTG 100 g. CONCLUSÕES: Os resultados da eficiência diagnóstica associados à simplicidade, praticabilidade e custo referendaram a associação GJ + FR como o mais adequado para o rastreamento. A equivalência das glicemias de 1hPS permitiram a proposição de um novo protocolo de rastreamento e diagnóstico do diabete gestacional, com menores custo e desconforto.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The identification of appropriate laboratory measures to confirm clinical hypotheses is important in routine paracoccidioidomycosis medical care. The clinical records and laboratory reports of 401 paracoccidioidomycosis patients attended at the Tropical Diseases Area, Faculdade de Medicina de Botucatu, from 1974 to 2008 were reviewed. Direct mycological (DM), cell block (CB), histopathological (HP), and double immunodiffusion (DID) tests were evaluated before treatment. Typical Paracoccidioides brasiliensis yeast forms were observed in clinical specimens of 86% of the patients, but 14% were detected only by serological test. DM of 51 different tissue specimens produced 74.5% sensitivity, and 62.5% sensitivity was observed in 112 sputum samples. CB in 483 sputum samples generated 55.3% sensitivity. HP performed in 239 samples from different tissues revealed 96.7% sensitivity. Serology carried out in 351 patients and 200 healthy controls provided 90.0% sensitivity, 100.0% specificity, 100.0% positive predictive value, 85.1% negative predictive value and 93.6% accuracy. Comparisons of laboratory measurements performed in the same patient showed that sensitivity decreases from HP to DID to CB and DM, with the last two assays providing similar sensitivities. This study demonstrated that P. brasiliensis identification by HP, CB, and/or DM associated with DID is sufficient to establish the laboratorial diagnosis of paracoccidioidomycosis in practically all cases. (C) 2011 Royal Society of Tropical Medicine and Hygiene. Published by Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We have investigated if a new LEDs system has enough efficient energy to promote efficient shear and tensile bonding strength resistance under standardized tests. LEDs 470 +/- 10 nm can be used to photocure composite during bracket fixation. Advantages considering resistance to tensile and shear bonding strength when these systems were used are necessary to justify their clinical use. Forty eight human extracted premolars teeth and two light sources were selected, one halogen lamp and a LEDs system. Brackets for premolar were bonded through composite resin. Samples were submitted to standardized tests. A comparison between used sources under shear bonding strength test, obtained similar results; however, tensile bonding test showed distinct results: a statistical difference at a level of 1% between exposure times (40 and 60 seconds) and even to an interaction between light source and exposure time. The best result was obtained with halogen lamp use by 60 seconds, even during re-bonding; however LEDs system can be used for bonding and re-bonding brackets if power density could be increased.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

With recent advances in technology and research into drug delivery, the modernization of tests and greater emphasis on the predictability of therapeutic effect by means of in vitro tests, the dissolution test and the study of dissolution profiles are gaining more and more importance. Though introduced initially as a way of characterizing the release profile of poorly soluble drugs, dissolution tests are currently part of pharmacopoeial monographs on almost all the oral solid pharmaceutical forms. The objective of this study was to determine the dissolution profile (percent drug dissolved versus time) of the pioneer brand, generic and similar pharmaceutical capsules containing 500mg cephalexin. Three pharmaceutical brands (reference, generic and similar) were subjected to the dissolution test and in vitro dissolution profiles were recorded. From the results of the dissolution test, it was concluded that the samples met the acceptance criterion, as no difference was observed in the percentage of the drug dissolved in a standard time. The dissolution profile indicated that this medicine, in this pharmaceutical form, dissolves readily (85% of the drug dissolved in 15 minutes) and the curves showed great similarity, suggesting that the 3 brands are pharmaceutically equivalent.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A major aspect in geosynthetics creep analysis is the load level applied to the specimen, usually referred as a percentage of the geosynthetic ultimate tensile strength (UTS). Since both tensile and creep standard tests are performed with in-isolation specimens, they may not reproduce the possibly significant effect of soil-geosynthetic interaction. A new creep testing machine was recently developed and successfully addressed this concern. However, further developments allowed tensile tests to be performed in the same conditions used in nonconventional creep ones. This paper presents the results of nonconventional tensile tests performed with a woven biaxial polyester geogrid. They were used to define its UTS in the same conditions employed in creep tests performed with the new equipment. Despite changes in tensile curves shapes were found, the UTS from confined, accelerated and confined-accelerated tensile tests were quite similar to those obtained with standard tensile test procedure.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The insecticide imidacloprid and the herbicide sulfentrazone are two different classes of pesticides that are used for pest control in sugarcane agriculture. To evaluate the genotoxic potential of low concentrations of these two pesticides alone and in mixture, the comet assay and the micronucleus (MN) test employing fluorescence in situ hybridization (FISH) with a centromeric probe were applied in human hepatoma cell lines (HepG2), in a 24-h assay. Mutagenicity was assessed by Salmonella/microsome assay with TA98 and TA100 strains in the absence and presence of an exogenous metabolizing system (S9). The results showed significant inductions of MN in HepG2 cells by both pesticides, for all the tested concentrations. As evidenced in the comet assay, only the imidacloprid presented significant responses. When the two pesticides were associated, a significant induction of damage was observed in the HepG2 cells by the comet assay, but not by the MN test. Moreover, the MN induced by the mixtures of the pesticides appeared at lower levels than those induced by sulfentrazone and imidacloprid when tested alone. According to the FISH results, the damage induced by imidacloprid in the HepG2 cells resulted from a clastogenic action of this insecticide (76.6% of the MN did not present a centromeric signal). For the herbicide sulfentrazone and for the mixture of the pesticides, a similar frequency of MN with and without the presence of the centromeric signal (herbicide: 52.45% of the MN without centromeric signal and 47.54% of the MN with centromeric signal; mixture: 48.71% of the MN without centromeric signal and 51.42% of the MN with centromeric signal) was verified. Based on these results, it was concluded that each one of the pesticides evaluated interacts with the DNA of HepG2 cells and causes irreparable alterations in the cells. However, the combination of the pesticides showed an antagonistic effect on the cells and the damage induced was milder and not persistent in HepG2 cells. The results obtained by the Ames test did not point out significant results.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: The negative sensory properties of casein hydrolysates (HC) often limit their usage in products intended for human consumption, despite HC being nutritious and having many functional benefits. Recent, but taxonomically limited, evidence suggests that other animals also avoid consuming HC when alternatives exist. Methodology/Principal Findings: We evaluated ingestive responses of five herbivorous species (guinea pig, mountain beaver, gopher, vole, and rabbit) and five omnivorous species (rat, coyote, house mouse, white-footed mouse, and deer mouse; N = 16–18/species) using solid foods containing 20% HC in a series of two-choice preference tests that used a nonprotein, cellulose-based alternative. Individuals were also tested with collagen hydrolysate (gelatin; GE) to determine whether it would induce similar ingestive responses to those induced by HC. Despite HC and GE having very different nutritional and sensory qualities, both hydrolysates produced similar preference score patterns. We found that the herbivores generally avoided the hydrolysates while the omnivores consumed them at similar levels to the cellulose diet or, more rarely, preferred them (HC by the white-footed mouse; GE by the rat). Follow-up preference tests pairing HC and the nutritionally equivalent intact casein (C) were performed on the three mouse species and the guinea pigs. For the mice, mean HC preference scores were lower in the HC v C compared to the HC v Cel tests, indicating that HC’s sensory qualities negatively affected its consumption. However, responses were species-specific. For the guinea pigs, repeated exposure to HC or C (4.7-h sessions; N = 10) were found to increase subsequent HC preference scores in an HC v C preference test, which was interpreted in the light of conservative foraging strategies thought to typify herbivores. Conclusions/Significance: This is the first empirical study of dietary niche-related taxonomic differences in ingestive responses to protein hydrolysates using multiple species under comparable conditions. Our results provide a basis for future work in sensory, physiological, and behavioral mechanisms of hydrolysate avoidance and on the potential use of hydrolysates for pest management.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An Adaptive Optic (AO) system is a fundamental requirement of 8m-class telescopes. We know that in order to obtain the maximum possible resolution allowed by these telescopes we need to correct the atmospheric turbulence. Thanks to adaptive optic systems we are able to use all the effective potential of these instruments, drawing all the information from the universe sources as best as possible. In an AO system there are two main components: the wavefront sensor (WFS) that is able to measure the aberrations on the incoming wavefront in the telescope, and the deformable mirror (DM) that is able to assume a shape opposite to the one measured by the sensor. The two subsystem are connected by the reconstructor (REC). In order to do this, the REC requires a “common language" between these two main AO components. It means that it needs a mapping between the sensor-space and the mirror-space, called an interaction matrix (IM). Therefore, in order to operate correctly, an AO system has a main requirement: the measure of an IM in order to obtain a calibration of the whole AO system. The IM measurement is a 'mile stone' for an AO system and must be done regardless of the telescope size or class. Usually, this calibration step is done adding to the telescope system an auxiliary artificial source of light (i.e a fiber) that illuminates both the deformable mirror and the sensor, permitting the calibration of the AO system. For large telescope (more than 8m, like Extremely Large Telescopes, ELTs) the fiber based IM measurement requires challenging optical setups that in some cases are also impractical to build. In these cases, new techniques to measure the IM are needed. In this PhD work we want to check the possibility of a different method of calibration that can be applied directly on sky, at the telescope, without any auxiliary source. Such a technique can be used to calibrate AO system on a telescope of any size. We want to test the new calibration technique, called “sinusoidal modulation technique”, on the Large Binocular Telescope (LBT) AO system, which is already a complete AO system with the two main components: a secondary deformable mirror with by 672 actuators, and a pyramid wavefront sensor. My first phase of PhD work was helping to implement the WFS board (containing the pyramid sensor and all the auxiliary optical components) working both optical alignments and tests of some optical components. Thanks to the “solar tower” facility of the Astrophysical Observatory of Arcetri (Firenze), we have been able to reproduce an environment very similar to the telescope one, testing the main LBT AO components: the pyramid sensor and the secondary deformable mirror. Thanks to this the second phase of my PhD thesis: the measure of IM applying the sinusoidal modulation technique. At first we have measured the IM using a fiber auxiliary source to calibrate the system, without any kind of disturbance injected. After that, we have tried to use this calibration technique in order to measure the IM directly “on sky”, so adding an atmospheric disturbance to the AO system. The results obtained in this PhD work measuring the IM directly in the Arcetri solar tower system are crucial for the future development: the possibility of the acquisition of IM directly on sky means that we are able to calibrate an AO system also for extremely large telescope class where classic IM measurements technique are problematic and, sometimes, impossible. Finally we have not to forget the reason why we need this: the main aim is to observe the universe. Thanks to these new big class of telescopes and only using their full capabilities, we will be able to increase our knowledge of the universe objects observed, because we will be able to resolve more detailed characteristics, discovering, analyzing and understanding the behavior of the universe components.