971 resultados para Rf Inhomogeneity
Resumo:
Dissertação para obtenção do Grau de Mestre em Engenharia Eletrotécnica e de Computadores, pela Universidade Nova de Ciências e Tecnologia
Resumo:
Dissertação para obtenção do Grau de Mestre em Engenharia Electrotécnica
Resumo:
In this thesis a CMOS low-power and low-voltage RF receiver front-end is presented. The main objective is to design this RF receiver so that it can be powered by a piezoelectric energy harvesting power source, included in a Wireless Sensor Node application. For this type of applications the major requirements are: the low-power and low-voltage operation, the reduced area and cost and the simplicity of the architecture. The system key blocks are the LNA and the mixer, which are studied and optimized with greater detail, achieving a good linearity, a wideband operation and a reduced introduction of noise. A wideband balun LNA with noise and distortion cancelling is designed to work at a 0.6 V supply voltage, in conjunction with a double-balanced passive mixer and subsequent TIA block. The passive mixer operates in current mode, allowing a minimal introduction of voltage noise and a good linearity. The receiver analog front-end has a total voltage conversion gain of 31.5 dB, a 0.1 - 4.3 GHz bandwidth, an IIP3 value of -1.35 dBm, and a noise figure lower than 9 dB. The total power consumption is 1.9 mW and the die area is 305x134.5 m2, using a standard 130 nm CMOS technology.
Resumo:
FUNDAMENTO: Ablação por radiofrequência (ARF) em crianças consiste em uma prática cada vez mais frequente. OBJETIVO: Avaliar, em nossa instituição, os resultados da ARF em crianças com idade abaixo de 15 anos. MÉTODOS: Foram analisadas 125 crianças submetidas à ARF entre maio de 1991 a maio de 2010. RESULTADOS: Sessenta e sete (53,6%) crianças eram do sexo masculino, com idade entre 44 dias e 15 anos (média de 8,6 ± 3,3 anos) e peso mediano de 31 kg. Cardiopatia esteve presente em 21 (16,8%) pacientes. A ARF de vias acessórias (VA) foi o procedimento mais comum (62 crianças - 49,6%). A ARF de taquicardias por reentrada nodal (TRN) foi a segunda arritmia mais frequente, em 27 (21,6%), seguida de taquicardias atriais (TA), em 16 (12,8%) e de taquicardias ventriculares (TV) em 8 (6,4%) crianças. Os critérios de sucesso foram alcançados em 86,9%, 96,1%, 80% e 62,5% dos pacientes submetidos à ARF de VA, TRN, TA e TV, respectivamente. Os bloqueios atrioventriculares transitórios (BAVT) ocorreram durante a ARF em 4 (3,2%) e BRD em 7 (5,6%) crianças. Vinte e cinco crianças foram submetidos à nova ARF por insucesso inicial ou recorrência. Durante o seguimento médio de 5,5 ± 3,4 anos, 107 (88,4%) persistiram sem recorrência. Não houve diferença estatística em relação aos resultados e à idade em que o paciente se submeteu ao procedimento. Nenhuma criança apresentou BAVT persistente ou necessitou de marca-passo definitivo. CONCLUSÃO: A ablação por cateter é uma alternativa terapêutica segura e eficiente em crianças com taquicardias recorrentes refratárias ao tratamento clínico.
Resumo:
Magdeburg, Univ., Fak. für Elektrotechnik und Informationstechnik, Diss., 2010
Resumo:
Combined media on photographic paper. 104" x 170"
Resumo:
Este proyecto tiene como objetivo diseñar un nuevo receptor SAR biestático para el sistema SABRINA (SAR Bistatic fixed Receiver for INterferometric Applications) caracterizando el sistema que ya existía. El nuevo dispositivo deberá cumplir con las características y requisitos del escenario teniendo en cuenta la potencia recibida y el ruido de cuantificación de la tarjeta digitalizadora. Con este fin se introducen previamente conocimientos de teoría RADAR y SAR. Además, se deberá compactar al máximo el sistema para conseguir un receptor autocontenido que facilite su traslado. Para tal fin se ha incorporado a la caja del receptor un sintetizador programable que actúa de oscilador local de las cadenas de recepción y una fuente de alimentación que provee la tensión a todos los componentes activos del dispositivo. Por otra parte el proyecto ilustra las diferentes campañas de experimentos que se han realizado durante el periodo de trabajo.
Resumo:
En la actualidad, la gran cantidad de aplicaciones que surgen dentro del ámbito de la radiofrecuencia hacen que el desarrollo de dispositivos dentro de este campo sea constante. Estos dispositivos cada vez requieren mayor potencia para frecuencias de trabajo elevadas, lo que sugiere abrir vías de investigación sobre dispositivos de potencia que ofrezcan los resultados deseados para altas frecuencias de operación (GHz). Dentro de este ámbito, el objetivo principal de este proyecto es el de realizar un estudio sobre este tipo de dispositivos, siendo el transistor LDMOS el candidato elegido para tal efecto, debido a su buen comportamiento en frecuencia para tensiones elevadas de funcionamiento.
Resumo:
En els últims anys printed electronics està aixecant un gran interès entre la indústria electrònica. Aquest tipus de procés consisteix en imprimir circuits amb tècniques d'impressió convencionals utilitzant tintes conductores, resistives, dielèctriques o semiconductores sobre substrats flexibles de baix cost com paper o plàstic. Fer servir aquestes tècniques s'espera que suposi una reducció dels costos de producció degut a que és un procés totalment additiu el que fa que sigui més senzill i es redueixi la quantitat de material emprat. El disseny de dispositius bàsics com resistències, condensadors i bobines per posteriorment veure la relació entre simulacions i valors obtinguts ha ocupat la primera part del projecte. La segona s’ha centrat en fer prototips d’antenes per a RFID (Radio Frequency IDentification) amb la tecnologia que es disposa a CEPHIS (Centre de Prototips i Solucions Hardwre-Software). Tot això ha servit per caracteritzar la tecnologia de la que es disposa i saber en quins apartats s’ha de seguir treballant per aconseguir millors prestacions.
Resumo:
High-field (>or=3 T) cardiac MRI is challenged by inhomogeneities of both the static magnetic field (B(0)) and the transmit radiofrequency field (B(1)+). The inhomogeneous B fields not only demand improved shimming methods but also impede the correct determination of the zero-order terms, i.e., the local resonance frequency f(0) and the radiofrequency power to generate the intended local B(1)+ field. In this work, dual echo time B(0)-map and dual flip angle B(1)+-map acquisition methods are combined to acquire multislice B(0)- and B(1)+-maps simultaneously covering the entire heart in a single breath hold of 18 heartbeats. A previously proposed excitation pulse shape dependent slice profile correction is tested and applied to reduce systematic errors of the multislice B(1)+-map. Localized higher-order shim correction values including the zero-order terms for frequency f(0) and radiofrequency power can be determined based on the acquired B(0)- and B(1)+-maps. This method has been tested in 7 healthy adult human subjects at 3 T and improved the B(0) field homogeneity (standard deviation) from 60 Hz to 35 Hz and the average B(1)+ field from 77% to 100% of the desired B(1)+ field when compared to more commonly used preparation methods.
Resumo:
This study focuses on methylamphetamine (MA) seizures made by the Australian Federal Police (AFP) to investigate the use of chemical profiling in an intelligence perspective. Correlation coefficients were used to obtain a similarity degree between a population of linked samples and a population of unlinked samples. Although it was demonstrated that a general framework can be followed for the use of any forensic case data in an intelligence-led perspective, threshold values have to be re-evaluated for each type of illicit drug investigated. Unlike the results obtained in a previous study on 3,4-methylenedioxymethylamphetamine (MDMA) seizures, chemical profiles of MA samples coming from the same seizure showed relative inhomogeneity, limiting their ability to link seizures. Different hypotheses were investigated to obtain a better understanding of this inhomogeneity although no trend was observed. These findings raise an interesting discussion in regards to the homogeneity and representativeness of illicit drug seizures (for intelligence purposes). Further, it also provides some grounds to discuss the initial hypotheses and assumptions that most forensic science studies are based on.
Resumo:
At 3 T, the effective wavelength of the RF field is comparable to the dimension of the human body, resulting in B1 standing wave effects and extra variations in phase. This effect is accompanied by an increase in B0 field inhomogeneity compared to 1.5 T. This combination results in nonuniform magnetization preparation by the composite MLEV weighted T2 preparation (T2 Prep) sequence used for coronary magnetic resonance angiography (MRA). A new adiabatic refocusing T2 Prep sequence is presented in which the magnetization is tipped into the transverse plane with a hard RF pulse and refocused using a pair of adiabatic fast-passage RF pulses. The isochromats are subsequently returned to the longitudinal axis using a hard RF pulse. Numerical simulations predict an excellent suppression of artifacts originating from B1 inhomogeneity while achieving good contrast enhancement between coronary arteries and surrounding tissue. This was confirmed by an in vivo study, in which coronary MR angiograms were obtained without a T2 Prep, with an MLEV weighted T2 Prep and the proposed adiabatic T2 Prep. Improved quantitative and qualitative coronary MRA image measurement was achieved using the adiabatic T2 Prep at 3 T.
Resumo:
This poster shows how to efficiently observe high-frequency figures of merit in RF circuits by measuring DC temperature with CMOS-compatible built-in sensors.
Resumo:
PURPOSE: Multinuclear magnetic resonance spectroscopy and imaging require a radiofrequency probe capable of transmitting and receiving at the proton and non-proton frequencies. To minimize coupling between probe elements tuned to different frequencies, LC (inductor-capacitor) traps blocking current at the (1) H frequency can be inserted in non-proton elements. This work compares LC traps with LCC traps, a modified design incorporating an additional capacitor, enabling control of the trap reactance at the low frequency while maintaining (1) H blocking. METHODS: Losses introduced by both types of trap were analysed using circuit models. Radiofrequency coils incorporating a series of LC and LCC traps were then built and evaluated at the bench. LCC trap performance was then confirmed using (1) H and (13) C measurements in a 7T human scanner. RESULTS: LC and LCC traps both effectively block interaction between non-proton and proton coils at the proton frequency. LCC traps were found to introduce a sensitivity reduction of 5±2%, which was less than half of that caused by LC traps. CONCLUSION: Sensitivity of non-proton coils is critical. The improved trap design, incorporating one extra capacitor, significantly reduces losses introduced by the trap in the non-proton coil. Magn Reson Med 72:584-590, 2014. © 2013 Wiley Periodicals, Inc.