992 resultados para RESULTS EVALUATION


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Query-by-Example Spoken Term Detection (QbE STD) aims at retrieving data from a speech data repository given an acoustic query containing the term of interest as input. Nowadays, it has been receiving much interest due to the high volume of information stored in audio or audiovisual format. QbE STD differs from automatic speech recognition (ASR) and keyword spotting (KWS)/spoken term detection (STD) since ASR is interested in all the terms/words that appear in the speech signal and KWS/STD relies on a textual transcription of the search term to retrieve the speech data. This paper presents the systems submitted to the ALBAYZIN 2012 QbE STD evaluation held as a part of ALBAYZIN 2012 evaluation campaign within the context of the IberSPEECH 2012 Conference(a). The evaluation consists of retrieving the speech files that contain the input queries, indicating their start and end timestamps within the appropriate speech file. Evaluation is conducted on a Spanish spontaneous speech database containing a set of talks from MAVIR workshops(b), which amount at about 7 h of speech in total. We present the database metric systems submitted along with all results and some discussion. Four different research groups took part in the evaluation. Evaluation results show the difficulty of this task and the limited performance indicates there is still a lot of room for improvement. The best result is achieved by a dynamic time warping-based search over Gaussian posteriorgrams/posterior phoneme probabilities. This paper also compares the systems aiming at establishing the best technique dealing with that difficult task and looking for defining promising directions for this relatively novel task.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper deals with the evaluation of the reliability of the analytical results obtained by Kalman filtering. Two criteria for evaluation were compared: one is based on the autocorrelation analysis of the innovation sequence, the so-called NAC criterion; the other is the innovations number, which actually is the autocorrelation coefficient of the innovation sequence at the initial wavelength. Both criteria allow compensation for the wavelength positioning errors in spectral scans, but there exists a difference in the way they work. The NAC criterion can provide information about the reliability of an individual result, which is very useful for the indication of unmodelled emissions, while the innovations number should be incorporated with the normalization of the innovations or seek the help of the sequence itself for the same purpose. The major limitation of the NAC criterion is that it does not allow the theoretical modelling of continuous backgrounds, which, however, is convenient in practical analysis and can be taken with the innovations number criterion.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This work evaluates the effect of wavelength positioning errors in spectral scans on analytical results when the Kalman filtering technique is used for the correction of line interferences in inductively coupled plasma atomic emission spectrometry (ICP-AES). The results show that a positioning accuracy of 0.1 pm is required in order to obtain accurate and precise estimates for analyte concentrations. The positioning error in sample scans is more crucial than that in model scans. The relative bias in measured analyte concentration originating from a positioning error in a sample scan increases linearly with an increase in the magnitude of the error and the peak distance of the overlapping lines, but is inversely proportional to the signal-to-background ratio. By the use of an optimization procedure for the positions of scans with the innovations number as the criterion, the wavelength positioning error can be reduced and, correspondingly, the accuracy and precision of analytical results improved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

To evaluate the effects of chronic lead exposure on the nervous system in adults, a set of neurobehavioural and electrophysiological tests was administered to 99 lead exposed foundry employees and 61 unexposed workers. Current and past blood lead concentrations were used to estimate the degree of lead absorption; all previous blood lead concentrations had been less than or equal to 90 micrograms/100 ml. Characteristic signs (such as wrist extensor weakness) or symptoms (such as colic) of lead poisoning were not seen. Sensory conduction in the sural nerve was not affected. By contrast, various neurobehavioural functions deteriorated with increasing lead burden. Workers with blood lead concentrations between 40 and 60 micrograms/100 ml showed impaired performance on tests of verbal concept formation, visual/motor performance, memory, and mood. Thus impairment in central nervous system function in lead exposed adults occurred in the absence of peripheral nervous system derangement and increased in severity with increasing lead dose.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

© 2015 Elsevier Inc. All rights reserved.Background 12-lead ECG is a critical component of initial evaluation of cardiac ischemia, but has traditionally been limited to large, dedicated equipment in medical care environments. Smartphones provide a potential alternative platform for the extension of ECG to new care settings and to improve timeliness of care. Objective To gain experience with smartphone electrocardiography prior to designing a larger multicenter study evaluating standard 12-lead ECG compared to smartphone ECG. Methods 6 patients for whom the hospital STEMI protocol was activated were evaluated with traditional 12-lead ECG followed immediately by a smartphone ECG using right (VnR) and left (VnL) limb leads for precordial grounding. The AliveCor™ Heart Monitor was utilized for this study. All tracings were taken prior to catheterization or immediately after revascularization while still in the catheterization laboratory. Results The smartphone ECG had excellent correlation with the gold standard 12-lead ECG in all patients. Four out of six tracings were judged to meet STEMI criteria on both modalities as determined by three experienced cardiologists, and in the remaining two, consensus indicated a non-STEMI ECG diagnosis. No significant difference was noted between VnR and VnL. Conclusions Smartphone based electrocardiography is a promising, developing technology intended to increase availability and speed of electrocardiographic evaluation. This study confirmed the potential of a smartphone ECG for evaluation of acute ischemia and the feasibility of studying this technology further to define the diagnostic accuracy, limitations and appropriate use of this new technology.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Un-supervised hyperspectral remote-sensing reflectance data (<15 km from the shore) were collected from a moving research vessel. Two different processing methods were compared. The results were similar to concurrent Aqua-MODIS and Suomi-NPP-VIIRS satellite data.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND: In this study we aimed to evaluate the role of a SNP in intron I of the ERCC4 gene (rs744154), previously reported to be associated with a reduced risk of breast cancer in the general population, as a breast cancer risk modifier in BRCA1 and BRCA2 mutation carriers.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Objective-To determine whether porcine dermatitis and nephropathy syndrome (PDNS) could be experimentally induced in gnotobiotic swine.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We present three natural language marking strategies based on fast and reliable shallow parsing techniques, and on widely available lexical resources: lexical substitution, adjective conjunction swaps, and relativiser switching. We test these techniques on a random sample of the British National Corpus. Individual candidate marks are checked for goodness of structural and semantic fit, using both lexical resources, and the web as a corpus. A representative sample of marks is given to 25 human judges to evaluate for acceptability and preservation of meaning. This establishes a correlation between corpus based felicity measures and perceived quality, and makes qualified predictions. Grammatical acceptability correlates with our automatic measure strongly (Pearson's r = 0.795, p = 0.001), allowing us to account for about two thirds of variability in human judgements. A moderate but statistically insignificant (Pearson's r = 0.422, p = 0.356) correlation is found with judgements of meaning preservation, indicating that the contextual window of five content words used for our automatic measure may need to be extended. © 2007 SPIE-IS&T.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Background: The public health burden of coronary artery disease (CAD) is important. Perfusion cardiac magnetic resonance (CMR) is generally accepted to detect and monitor CAD. Few studies have so far addressed its costs and costeffectiveness. Objectives: To compare in a large CMR registry the costs of a CMR-guided strategy vs two hypothetical invasive strategies for the diagnosis and the treatment of patients with suspected CAD. Methods: In 3'647 patients with suspected CAD included prospectively in the EuroCMR Registry (59 centers; 18 countries) costs were calculated for diagnostic examinations, revascularizations as well as for complication management over a 1-year follow-up. Patients with ischemia-positive CMR underwent an invasive X-ray coronary angiography (CXA) and revascularization at the discretion of the treating physician (=CMR+CXA strategy). Ischemia was found in 20.9% of patients and 17.4% of them were revascularized. In ischemia-negative patients by CMR, cardiac death and non-fatal myocardial infarctions occurred in 0.38%/y. In a hypothetical invasive arm the costs were calculated for an initial CXA followed by FFR testing in vessels with ≥50% diameter stenoses (=CXA+FFR strategy). To model this hypothetical arm, the same proportion of ischemic patients and outcome was assumed as for the CMR+CXA strategy. The coronary stenosis - FFR relationship reported in the literature was used to derive the proportion of patients with ≥50% diameter stenoses (Psten) in the study cohort. The costs of a CXA-only strategy were also calculated. Calculations were performed from a third payer perspective for the German, UK, Swiss, and US healthcare systems.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Evaluation of major feed resources was conducted in four crop-livestock mixed farming systems of central southern Ethiopia, with 90 farmers, selected using multi-stage purposive and random sampling methods. Discussions were held with focused groups and key informants for vernacular name identification of feed, followed by feed sampling to analyse chemical composition (CP, ADF and NDF), in-vitro dry matter digestibility (IVDMD), and correlate with indigenous technical knowledge (ITK). Native pastures, crop residues (CR) and multi-purpose trees (MPT) are the major feed resources, demonstrated great variations in seasonality, chemical composition and IVDMD. The average CP, NDF and IVDMD values for grasses were 83.8 (ranged: 62.9–190), 619 (ranged: 357–877) and 572 (ranged: 317–743) g kg^(−1) DM, respectively. Likewise, the average CP, NDF and IVDMD for CR were 58 (ranged: 20–90), 760 (ranged: 340–931) and 461 (ranged: 285–637)g kg^(−1) DM, respectively. Generally, the MPT and non-conventional feeds (NCF, Ensete ventricosum and Ipomoea batatas) possessed higher CP (ranged: 155–164 g kg^(−1) DM) and IVDMD values (611–657 g kg^(−1) DM) while lower NDF (331–387 g kg^(−1) DM) and ADF (321–344 g kg^(−1) DM) values. The MPT and NCF were ranked as the best nutritious feeds by ITK while crop residues were the least. This study indicates that there are remarkable variations within and among forage resources in terms of chemical composition. There were also complementarities between ITK and feed laboratory results, and thus the ITK need to be taken into consideration in evaluation of local feed resources.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper presents the results of the crowd image analysis challenge, as part of the PETS 2009 workshop. The evaluation is carried out using a selection of the metrics available in the Video Analysis and Content Extraction (VACE) program and the CLassification of Events, Activities, and Relationships (CLEAR) consortium. The evaluation highlights the strengths of the authors’ systems in areas such as precision, accuracy and robustness.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper presents the results of the crowd image analysis challenge of the Winter PETS 2009 workshop. The evaluation is carried out using a selection of the metrics developed in the Video Analysis and Content Extraction (VACE) program and the CLassification of Events, Activities, and Relationships (CLEAR) consortium [13]. The evaluation highlights the detection and tracking performance of the authors’systems in areas such as precision, accuracy and robustness. The performance is also compared to the PETS 2009 submitted results.