971 resultados para Portuguese scientific publishers
Resumo:
Recent studies have revealed regional variation in the density and distribution of inhibitory neurons in different cortical areas, which are thought to reflect area-specific specializations in cortical circuitry. However, there are as yet few standardized quantitative data regarding how the inhibitory circuitry in prefrontal cortex (PFC), which is thought to be involved in executive functions such as cognition, emotion and decision making, compares to that in other cortical areas. Here we used immunohistochemical techniques to determine the density and distribution of parvalbumin (PV)-, calbindin (CB)-, and calretinin (CR)-immunoreactive (ir) neurons and axon terminals in the dorsolateral and orbital PFC of the owl monkey (Aotus trivirgatus), and compared them directly with data obtained using the same techniques in 11 different visual, somatosensory and motor areas. We found marked differences in the density of PV-ir, CB-ir, and CR-ir interneurons in several cortical areas. One hundred and twenty eight of all 234 possible between-area pairwise comparisons were significantly different. The density of specific subpopulations of these cells also varied among cortical areas, as did the density of axon terminals. Comparison of PFC with other cortical areas revealed that 40 of all 66 possible statistical comparisons of the density of PV-ir, CB-ir, and CR-ir cells were significantly different. We also found evidence for heterogeneity in the pattern of labeling of PV-ir, CB-ir, and CR-ir cells and axon terminals between the dorsolateral and orbital subdivisions of PFC. These data are likely to reflect basic differences in interneuron circuitry, which are likely to influence inhibitory function in the cortex. Copyright (C) 2003 S. Karger AG, Basel.
Resumo:
In this paper we present results on the optimization of multilayered a-SiC:H heterostructures that can be used as optical transducers for fluorescent proteins detection using the Fluorescence Resonance Energy Transfer approach. Double structures composed by pin based aSiC:H cells are analyzed. The color discrimination is achieved by ac photocurrent measurement under different externally applied bias. Experimental data on spectral response analysis, current-voltage characteristics and color and transmission rate discrimination are reported. An electrical model, supported by a numerical simulation gives insight into the device operation. Results show that the optimized a-SiC:H heterostructures act as voltage controlled optical filters in the visible spectrum. When the applied voltages are chosen appropriately those optical transducers can detect not only the selective excitation of specimen fluorophores, but also the subsequent weak acceptor fluorescent channel emission.
Resumo:
In this paper we present an amorphous silicon device that can be used in two operation modes to measure the concentration of ions in solution. While crystalline devices present a higher sensitivity, their amorphous counterpart present a much lower fabrication cost, thus enabling the production of cheap disposable sensors for use, for example, in the food industry. The devices were fabricated on glass substrates by the PECVD technique in the top gate configuration, where the metallic gate is replaced by an electrolytic solution with an immersed Ag/AgCl reference electrode. Silicon nitride is used as gate dielectric enhancing the sensitivity and passivation layer used to avoid leakage and electrochemical reactions. In this article we report on the semiconductor unit, showing that the device can be operated in a light-assisted mode, where changes in the pH produce changes on the measured ac photocurrent. In alternative the device can be operated as a conventional ion selective field effect device where changes in the pH induce changes in the transistor's threshold voltage.
Resumo:
Introdução: A produção e o uso da literatura científica são analisados, quantificados e interpretados pela bibliometria, ciência utilizada para estudos métricos da informação publicada e que estuda as questões relacionadas com a comunicação científica e a atividade científica. Objetivo: O estudo apresentado é uma análise bibliométrica da produção científica portuguesa da área da saúde indexada na Web of Science. Métodos: Analisa-se a produção referente ao período entre 1992 e final de 2011. A análise da produção científica centrou-se nas seguintes variáveis: categorias de classificação da Web of Science, tipologia de documentos indexados, títulos de revistas, distribuição por anos de publicação, afiliação institucional, idiomas, países de origem dos autores com quem foram estabelecidas relações de parceria científica e quem facultou os financiamentos à investigação científica. Resultados: Foram contabilizados 34.208 trabalhos. Destes, o artigo é a forma mais utilizada pelos autores portugueses para a divulgação dos resultados de investigação (58,5%). A década mais recente é contemplada com 75,4% dos registos. A maioria da produção com visibilidade internacional é oriunda de universidades e de centros de investigação hospitalar; institutos, laboratórios da indústria farmacêutica e universidades estrangeiras têm valores residuais. A colaboração com outros investigadores internacionais destaca-se no caso da Europa (73,2%). O financiamento da investigação científica é suportado basicamente pela Fundação para a Ciência e Tecnologia (59,5%), seguida da Comissão Europeia (17,8%). O inglês é o idioma mais usado para a divulgação dos resultados de investigação nacional na área da saúde (97,8%). Conclusões: O uso de bases de dados ou de plataformas científicas para estudos bibliométricos é um processo moroso e difícil. O total de trabalhos em análise foi sempre o mesmo mas, em algumas variáveis, os valores não coincidem, quer porque alguns dos registos foram classificados em mais do que uma categoria temática, quer pelos trabalhos multidisciplinares oriundos das mesmas instituições, quer pelos trabalhos de colaboração internacional. Também no presente estudo os artigos são o veículo privilegiado para a divulgação dos resultados científicos. Apontamento final: deve encorajar-se a utilização de outras plataformas científicas e de outras bases de dados para uma mais completa recuperação da produção científica nacional na área da saúde. Introduction: The production and the use of the scientific literature are analyzed, quantified and interpreted by bibliometry. Bibliometry is the science used in published information metric studies and studies the questions of scientific communication and the scientific production. Aim of the study: This study presents a bibliometric analysis of the indexed Web of Science Portuguese scientific production in the health field. Methods: We analyzed the production from 1992 to the end of 2011. This analysis focused in several variables: general categories areas of Web of Science, indexed document types, source titles, publication years, group/corporate authors, languages, identification of the countries with scientific partnerships and identification of the funding agencies for scientific research. Results: We found 34.208 works. From this, the article is the most common channel for disseminating the research results (58.5%). The most recent decade has 75.4% of the total of records. Most of the production with international visibility becomes from universities and hospital research centers; institutes, pharmaceutical labs or foreign universities have residual values. Collaborating with other international researchers is very common, particularly with Europe (73.2%). In general, the Fundação para a Ciência e Tecnologia supports the scientific research (59.5%), followed by the European Commission (17.8%). The language commonly used for disseminating the research results in health is the English (97.8%). Conclusions: Using databases or scientific platforms for bibliometric studies is a hard and difficult process. The total of works analyzed was always the same but, with some variables, the numbers does not coincide: a) some of the registries were classified in several categories; b) some of the multidisciplinary works were from the same institution; c) the large number of international partnership. In this study, articles are the privileged way for disseminating the scientific results. A last thought: the use of other scientific platforms and databases should be encouraged for a more complete retrieval of the national research production in health.
Resumo:
Introdução: A produção e o uso da literatura científica são analisados, quantificados e interpretados pela bibliometria, ciência utilizada para estudos métricos da informação publicada e que estuda as questões relacionadas com a comunicação científica e a atividade científica. Objetivo: O estudo apresentado é uma análise bibliométrica da produção científica portuguesa da área da saúde indexada na Web of Science. Métodos: Analisa-se a produção referente ao período entre 1992 e final de 2011. A análise da produção científica centrou-se nas seguintes variáveis: categorias de classificação da Web of Science, tipologia de documentos indexados, títulos de revistas, distribuição por anos de publicação, afiliação institucional, idiomas, países de origem dos autores com quem foram estabelecidas relações de parceria científica e quem facultou os financiamentos à investigação científica. Resultados: Foram contabilizados 34.208 trabalhos. Destes, o artigo é a forma mais utilizada pelos autores portugueses para a divulgação dos resultados de investigação (58,5%). A década mais recente é contemplada com 75,4% dos registos. A maioria da produção com visibilidade internacional é oriunda de universidades e de centros de investigação hospitalar; institutos, laboratórios da indústria farmacêutica e universidades estrangeiras têm valores residuais. A colaboração com outros investigadores internacionais destaca-se no caso da Europa (73,2%). O financiamento da investigação científica é suportado basicamente pela Fundação para a Ciência e Tecnologia (59,5%), seguida da Comissão Europeia (17,8%). O inglês é o idioma mais usado para a divulgação dos resultados de investigação nacional na área da saúde (97,8%). Conclusões: O uso de bases de dados ou de plataformas científicas para estudos bibliométricos é um processo moroso e difícil. O total de trabalhos em análise foi sempre o mesmo mas, em algumas variáveis, os valores não coincidem, quer porque alguns dos registos foram classificados em mais do que uma categoria temática, quer pelos trabalhos multidisciplinares oriundos das mesmas instituições, quer pelos trabalhos de colaboração internacional. Também no presente estudo os artigos são o veículo privilegiado para a divulgação dos resultados científicos. Apontamento final: deve encorajar-se a utilização de outras plataformas científicas e de outras bases de dados para uma mais completa recuperação da produção científica nacional na área da saúde. Introduction: The production and the use of the scientific literature are analyzed, quantified and interpreted by bibliometry. Bibliometry is the science used in published information metric studies and studies the questions of scientific communication and the scientific production. Aim of the study: This study presents a bibliometric analysis of the indexed Web of Science Portuguese scientific production in the health field. Methods: We analyzed the production from 1992 to the end of 2011. This analysis focused in several variables: general categories areas of Web of Science, indexed document types, source titles, publication years, group/corporate authors, languages, identification of the countries with scientific partnerships and identification of the funding agencies for scientific research. Results: We found 34.208 works. From this, the article is the most common channel for disseminating the research results (58.5%). The most recent decade has 75.4% of the total of records. Most of the production with international visibility becomes from universities and hospital research centers; institutes, pharmaceutical labs or foreign universities have residual values. Collaborating with other international researchers is very common, particularly with Europe (73.2%). In general, the Fundação para a Ciência e Tecnologia supports the scientific research (59.5%), followed by the European Commission (17.8%). The language commonly used for disseminating the research results in health is the English (97.8%). Conclusions: Using databases or scientific platforms for bibliometric studies is a hard and difficult process. The total of works analyzed was always the same but, with some variables, the numbers does not coincide: a) some of the registries were classified in several categories; b) some of the multidisciplinary works were from the same institution; c) the large number of international partnership. In this study, articles are the privileged way for disseminating the scientific results. A last thought: the use of other scientific platforms and databases should be encouraged for a more complete retrieval of the national research production in health.
Resumo:
Oxide based diluted magnetic semiconductor (DMS) materials have been a subject of increasing interest due to reports of room temperature ferromagnetism in several systems and their potential use in the development of spintronic devices. However, concerns on the stability of the magnetic properties of different DMS systems have been raised. Their magnetic moment is often unstable, vanishing with a characteristic decay time of weeks or months, which precludes the development of real applications. This paper reports on the ferromagnetic properties of two-year-aged Ti1-xCoxO2-δ reduced anatase nanopowders with different Co contents (0.03≤x≤0.10). Aged samples retain rather high values of magnetization, remanence and coercivity which provide strong evidence for a quite preserved long-range ferromagnetic order. In what concern Co segregation, some degree of metastability of the diluted Co doped anatase structure could be inferred in the case of the sample with the higher Co content.
Resumo:
Optical colour sensors based on multilayered a-SiC:H heterostructures can act as voltage controlled optical filters in the visible range. In this article we investigate the application of these structures for Fluorescence Resonance Energy Transfer (FRET) detection, The characteristics of a-SiC:H multilayered structure are studied both theoretically and experimentally in several wavelengths corresponding to different fluorophores. The tunable optical p-i'(a-SiC:H)-n/p-i(a-Si:H)-n heterostructures were produced by PECVD and tested for a proper fine tuning in the violet, cyan and yellow wavelengths. The devices were characterized through transmittance and spectral response measurements, under different electrical bias and frequencies. Violet, cyan and yellow signals were applied in simultaneous and results have shown that they can be recovered under suitable applied bias. A theoretical analysis supported by numerical simulation is presented.
Resumo:
Toxic amides, such as acrylamide, are potentially harmful to Human health, so there is great interest in the fabrication of compact and economical devices to measure their concentration in food products and effluents. The CHEmically Modified Field Effect Transistor (CHEMFET) based onamorphous silicon technology is a candidate for this type of application due to its low fabrication cost. In this article we have used a semi-empirical modelof the device to predict its performance in a solution of interfering ions. The actual semiconductor unit of the sensor was fabricated by the PECVD technique in the top gate configuration. The CHEMFET simulation was performed based on the experimental current voltage curves of the semiconductor unit and on an empirical model of the polymeric membrane. Results presented here are useful for selection and design of CHEMFET membranes and provide an idea of the limitations of the amorphous CHEMFET device. In addition to the economical advantage, the small size of this prototype means it is appropriate for in situ operation and integration in a sensor array.
Resumo:
The characteristics of tunable wavelength filters based on a-SiC:H multilayered stacked pin cells are studied both theoretically and experimentally. The optical transducers were produced by PECVD and tested for a proper fine tuning of the cyan and yellow fluorescent proteins emission. The active device consists of a p-i'(a-SiC:H)-n/p-i(a-Si:H)-n heterostructures sandwiched between two transparent contacts. Experimental data on spectral response analysis, current-voltage characteristics and color and transmission rate discrimination are reported. Cyan and yellow fluorescent input channels were transmitted together, each one with a specific transmission rate and different intensities. The multiplexed optical signal was analyzed by reading out, under positive and negative applied voltages, the generated photocurrents. Results show that the optimized optical transducer has the capability of combining the transient fluorescent signals onto a single output signal without losing any specificity (color and intensity). It acts as a voltage controlled optical filter: when the applied voltages are chosen appropriately the transducer can select separately the cyan and yellow channel emissions (wavelength and frequency) and also to quantify their relative intensities. A theoretical analysis supported by a numerical simulation is presented.
Resumo:
In this paper we present results on the use of a multilayered a-SiC:H heterostructure as a wavelength-division demultiplexing device for the visible light spectrum. The proposed device is composed of two stacked p-i-n photodiodes with intrinsic absorber regions adjusted to short and long wavelength absorption and carrier collection. An optoelectronic characterisation of the device was performed in the visible spectrum. Demonstration of the device functionality for WDM applications was done with three different input channels covering the long, the medium and the short wavelengths in the visible range. The recovery of the input channels is explained using the photocurrent spectral dependence on the applied voltage. An electrical model of the WDM device is proposed and supported by the solution of the respective circuit equations. Short range optical communications constitute the major application field, however other applications are also foreseen.
Resumo:
ZnO films doped with vanadium (ZnO:V) have been prepared by dc reactive magnetron sputtering technique at different substrate temperatures (RT–500 C). The effects of the substrate temperature on ZnO:V films properties have been studied. XRD measurements show that only ZnO polycrystalline structure has been obtained, no V2O5 or VO2 crystal phase can be observed. It has been found that the film prepared at low substrate temperature has a preferred orientation along the (002) direction. As the substrate temperature is increased, the (002) peak intensity decreases. When the substrate temperature reaches the 500 C, the film shows a random orientation. SEM measurements show a clear formation of the nano-grains in the sample surface when the substrate temperature is higher than 400 C. The optical properties of the films have been studied by measuring the specular transmittance. The refractive index has been calculated by fitting the transmittance spectra using OJL model combined with harmonic oscillator.
Resumo:
In the last decades TiAlN coatings deposited by PVD techniques have been extensively investigated but, nowadays, their potential development for tribological applications is relatively low. However, new coatings are emerging based on them, trying to improve wear behavior. TiAlSiN thin coatings are now investigated, analyzing if Si introduction increases the wear resistance of PVD films. Attending to the application, several wear test configurations has been recently used by some researchers. In this work, TiAlSiN thin coatings were produced by PVD Unbalanced Magnetron Sputtering technique and they were conveniently characterized using Scanning Electron Microscopy (SEM) provided with Energy Dispersive Spectroscopy (EDS), Atomic Force Microscopy (AFM), Electron Probe Micro-Analyzer (EPMA), Micro Hardness (MH) and Scratch Test Analysis. Properties as morphology, thickness, roughness, chemical composition and structure, hardness and film adhesion to the substrate were investigated. Concerning to wear characterization, two very different ways were chosen: micro-abrasion with ball-on-flat configuration and industrial non-standardized tests based on samples inserted in a feed channel of a selected plastic injection mould working with 30% (wt.) glass fiber reinforced polypropylene. TiAlSiN coatings with a small amount of about 5% (wt.) Si showed a similar wear behavior when compared with TiAlN reported performances, denoting that Si addition does not improve the wear performance of the TiAlN coatings in these wear test conditions.
Resumo:
Titanium Diboride (TiB2) presents high mechanical and physical properties. Some wear studies were also carried out in order to evaluate its tribological properties. One of the most popular wear tests for thin films is the ball-cratering configuration. This work was focused on the study of the tribological properties of TiB2 thin films using micro-abrasion tests and following the BS EN 1071-6: 2007 standard. Due to high hardness usually patented by these films, diamond was selected as abrasive on micro-abrasion tests. Micro-abrasion wear tests were performed under five different durations, using the same normal load, speed rotation and ball. Films were deposited by unbalanced magnetron sputtering Physical Vapour Deposition (PVD) technique using TiB2 targets. TiB2 films were characterized using different methods as Scanning Electron Microscopy (SEM), Energy Dispersive X-ray Spectroscopy (EDS), Atomic Force Microscopy (AFM), X-ray Diffraction (XRD), Electron Probe Micro-Analyser (EPMA), Ultra Micro Hardness and Scratch-test Analysis, allowing to confirm that TiB2 presents adequate mechanical and physical properties. Ratio between hardness (coating and abrasive particles), wear resistance and wear coefficient were studied, showing that TiB2 films shows excellent properties for tribological applications.
Resumo:
This paper presents the Pseudo phase plane (PPP) method for detecting the existence of a nanofilm on the nitroazobenzene-modified glassy carbon electrode (NAB-GC) system. This modified electrode systems and nitroazobenze-nanofilm were prepared by the electrochemical reduction of diazonium salt of NAB at the glassy carbon electrodes (GCE) in nonaqueous media. The IR spectra of the bare glassy carbon electrodes (GCE), the NAB-GC electrode system and the organic NAB film were recorded. The IR data of the bare GC, NAB-GC and NAB film were categorized into five series consisting of FILM1, GC-NAB1, GC1; FILM2, GC-NAB2, GC2; FILM3, GC-NAB3, GC3 and FILM4, GC-NAB4, GC4 respectively. The PPP approach was applied to each group of the data of unmodified and modified electrode systems with nanofilm. The results provided by PPP method show the existence of the NAB film on the modified GC electrode.
Resumo:
The aim of this work is to characterize the nanofilm consisting of the benzoic acid-modified glassy carbon (GC) electrode system through multidimensional scaling space analysis. The surface modification is based on the electrochemical reaction between the GC electrode and benzoic acid-diazonium salt (BA-DAS). As a result, the nonofilms regarding the benzoic acid-glassy carbon (BA-GC) electrode surface was obtained. For the analysis of the naonfilm of BC-GC electrode system, the IR spectra of the modified BA-GC electrode surface, GC surface and BA-DAS were recorded in the spectral range of 599.84 – 3996.34 [cm–1]. The IR data vectors of the above three forms were processed by the using the multidimensional scaling space approach to demonstrate the existence of a nanofilm on the modified BA-GC electrode system. Two- and three-dimensional MDS profiles obtained by application of multidimensional scaling approach to the data sets {CG1,...,CG10}, {BA-GC1,...,BA-GC10} and {FILM1,...,FILM10} allow a good recognition of the nanofilm on the modified glassy carbon (GC) electrode system.