934 resultados para Portata cardiaca, Fick, termodiluizione, Cardiac output, Indicatore, Pazienti
Resumo:
We have used an animal model to test the reliability of a new portable continuous-wave Doppler ultrasonic cardiac output monitor, the USCOM. In six anesthetized dogs, cardiac output was measured with a high-precision transit time ultrasonic flowprobe placed on the ascending aorta. The dogs' cardiac output was increased with a dopamine infusion (0-15 mug (.) kg(-1) (.) min(-1)). Simultaneous flowprobe and USCOM cardiac output measurements were made. Up to 64 pairs of readings were collected from each dog. Data were compared by using the Bland and Altman plot method and Lin's concordance correlation coefficient. A total of 319 sets of paired readings were collected. The mean (+/-SD) cardiac output was 2.62 +/- 1.04 L/min, and readings ranged from 0.79 to 5.73 L/min. The mean bias between the 2 sets of readings was -0.01 L/min, with limits of agreement (95% confidence intervals) of -0.34 to 0.31 L/min. This represents a 13% error. In five of six dogs, there was a high degree of concordance, or agreement, between the 2 methods, with coefficients >0.9. The USCOM provided reliable measurements of cardiac output over a wide range of values. Clinical trials are needed to validate the device in humans.
Resumo:
Copyright © 2014 International Anesthesia Research Society.BACKGROUND: Goal-directed fluid therapy (GDFT) is associated with improved outcomes after surgery. The esophageal Doppler monitor (EDM) is widely used, but has several limitations. The NICOM, a completely noninvasive cardiac output monitor (Cheetah Medical), may be appropriate for guiding GDFT. No prospective studies have compared the NICOM and the EDM. We hypothesized that the NICOM is not significantly different from the EDM for monitoring during GDFT. METHODS: One hundred adult patients undergoing elective colorectal surgery participated in this study. Patients in phase I (n = 50) had intraoperative GDFT guided by the EDM while the NICOM was connected, and patients in phase II (n = 50) had intraoperative GDFT guided by the NICOM while the EDM was connected. Each patient's stroke volume was optimized using 250- mL colloid boluses. Agreement between the monitors was assessed, and patient outcomes (postoperative pain, nausea, and return of bowel function), complications (renal, pulmonary, infectious, and wound complications), and length of hospital stay (LOS) were compared. RESULTS: Using a 10% increase in stroke volume after fluid challenge, agreement between monitors was 60% at 5 minutes, 61% at 10 minutes, and 66% at 15 minutes, with no significant systematic disagreement (McNemar P > 0.05) at any time point. The EDM had significantly more missing data than the NICOM. No clinically significant differences were found in total LOS or other outcomes. The mean LOS was 6.56 ± 4.32 days in phase I and 6.07 ± 2.85 days in phase II, and 95% confidence limits for the difference were -0.96 to +1.95 days (P = 0.5016). CONCLUSIONS: The NICOM performs similarly to the EDM in guiding GDFT, with no clinically significant differences in outcomes, and offers increased ease of use as well as fewer missing data points. The NICOM may be a viable alternative monitor to guide GDFT.
Resumo:
La portata media cardiaca, (cardiac output “CO”) è un parametro essenziale per una buona gestione dei pazienti o per il monitoraggio degli stessi durante la loro permanenza nell’unità di terapia intensiva. La stesura di questo elaborato prende spunto sull’articolo di Theodore G. Papaioannou, Orestis Vardoulis, and Nikos Stergiopulos dal titolo “ The “systolic volume balance” method for the non invasive estimation of cardiac output based on pressure wave analysis” pubblicato sulla rivista American Journal of Physiology-Heart and Circulatory Physiology nel Marzo 2012. Nel sopracitato articolo si propone un metodo per il monitoraggio potenzialmente non invasivo della portata media cardiaca, basato su principi fisici ed emodinamici, che usa l’analisi della forma d’onda di pressione e un metodo non invasivo di calibrazione e trova la sua espressione ultima nell’equazione Qsvb=(C*PPao)/(T-(Psm,aorta*ts)/Pm). Questa formula è stata validata dagli autori, con buoni risultati, solo su un modello distribuito della circolazione sistemica e non è ancora stato validato in vivo. Questo elaborato si pone come obiettivo quello di un’analisi critica di questa formula per la stima della portata media cardiaca Qsvb. La formula proposta nell'articolo verrà verificata nel caso in cui la circolazione sistemica sia approssimata con modelli di tipo windkessel. Dallo studio svolto emerge il fatto che la formula porta risultati con errori trascurabili solo se si approssima la circolazione sistemica con il modello windkessel classico a due elementi (WK2) e la portata aortica con un’onda rettangolare. Approssimando la circolazione sistemica con il modello windkessel a tre elementi (WK3), o descrivendo la portata aortica con un’onda triangolare si ottengono risultati con errori non più trascurabili che variano dal 7%-9% nel caso del WK2 con portata aortica approssimata con onda triangolare ad errori più ampi del 20% nei i casi del WK3 per entrambe le approssimazioni della portata aortica.
Resumo:
Obiettivo: studio longitudinale di una coorte di gravidanze gemellari e valutazione di eventuali correlazioni tra specifici parametri cardiaci materni ed esito sfavorevole della gravidanza. Metodi: Sono state arruolate in modo prospettico donne con gravidanze gemellari, sottoposte a controlli seriati della funzione cardiaca materna ( 20-23 settimane; 26-29 settimane e 30-33 settimane). Le pazienti in cui il parto si è verificato prima della 34°settimana compiuta di gestazione sono state escluse a priori dallo studio. Specifici parametri cardiaci campionati sono stati confrontati tra il gruppo di gravidanze con esito positivo ed il gruppo di pazienti che hanno sviluppato complicanze nel corso della gravidanza quali: preeclampsia o ipertensione gestazionale, basso peso alla nascita ( SGA: peso neonatale di uno o entrambi i feti < 5° centile per l’epoca di gestazione). Risultati: sono state incluse nello studio 28 gravidanze gemellari,di cui 8 complicate. Durante ogni visita abbiamo osservato un aumento significativo della gittata cardiaca ( CO ) e sistolica ( SV ) ed una caduta delle resistenze vascolari totali ( TVR ) nelle gravidanze gemellari normali vs complicate. Inoltre, CO, pressione arteriosa (BP), frequenza cardiaca ( HR ) e TVR son rimaste invariate nel corso dei controlli ambulatoriali per le gravidanze con esiti sfavorevole, mentre mostravano modificazioni significative ( CO, HR e BDP in aumento; TVR in diminuzione ) nel gruppo di pazienti con esito favorevole della gravidanza. Conclusioni: La valutazione longitudinale della funzione cardiaca materna sembra dimostrare una significativa differenza tra i valori dei parametri cardiaci materni delle gravidanze multiple non complicate, rispetto a quelle complicate da preeclampsia o neonati SGA.
Resumo:
Introducción: Diversos cambios ocurren en el sistema cardiovascular materno durante el embarazo, lo que genera un gran estrés sobre este sistema especialmente durante el tercer trimestre, pudiendo acentuarse en presencia de determinados factores de riesgo. Los objetivos de este estudio fueron, valorar las adaptaciones cardiovasculares producidas por un programa específico de ejercicio físico; su seguridad sobre el sistema cardiovascular materno y los resultados del embarazo; y su eficacia en el control de los factores de riesgo cardiovascular. Material y métodos: El diseño del estudio fue un ensayo clínico aleatorizado. 151 gestantes sanas fueron evaluadas mediante un ecocardiograma y un electrocardiograma en la semana 20 y 34 de gestación. Un total de 89 gestantes participaron en un programa de ejercicio físico (GE) desde el primer hasta el tercer trimestre de embarazo, constituido principalmente por 25-30 minutos de trabajo aeróbico (55-60% de la frecuencia cardiaca de reserva), trabajo de fortalecimiento general y específico, y un trabajo de tonificación del suelo pélvico; desarrollado 3 días a la semana con una duración de 55-60 minutos cada sesión. Las gestantes aleatoriamente asignadas al grupo de control (GC; n=62) permanecieron sedentarias durante el embarazo. El estudio fue aprobado por el Comité Ético de investigación clínica del Hospital Universitario de Fuenlabrada. Resultados: Las características basales fueron similares entre ambos grupos. A diferencia del GC, las gestantes del GE evitaron el descenso significativo del gasto cardiaco indexado, entre el 2º y 3ºT de embarazo, y conservaron el patrón geométrico normal del ventrículo izquierdo; mientras que en el GC cambió hacia un patrón de remodelado concéntrico. En la semana 20, las gestantes del GE presentaron valores significativamente menores de frecuencia cardiaca (GC: 79,56±10,76 vs. GE: 76,05±9,34; p=0,04), tensión arterial sistólica (GC: 110,19±10,23 vs. GE: 106,04±12,06; p=0,03); tensión arterial diastólica (GC: 64,56±7,88 vs. GE: 61,81±7,15; p=0,03); tiempo de relajación isovolumétrica (GC: 72,94±14,71 vs. GE: 67,05±16,48; p=0,04); y un mayor tiempo de deceleración de la onda E (GC: 142,09±39,11 vs. GE: 162,10±48,59; p=0,01). En la semana 34, el GE presentó valores significativamente superiores de volumen sistólico (GC: 51,13±11,85 vs. GE: 56,21±12,79 p=0,04), de llenado temprano del ventrículo izquierdo (E) (GC: 78,38±14,07 vs. GE: 85,30±16,62; p=0,02) y de tiempo de deceleración de la onda E (GC: 130,35±37,11 vs. GE: 146,61±43,40; p=0,04). Conclusión: La práctica regular de ejercicio físico durante el embarazo puede producir adaptaciones positivas sobre el sistema cardiovascular materno durante el tercer trimestre de embarazo, además de ayudar en el control de sus factores de riesgo, sin alterar la salud materno-fetal. ABSTRACT Background: Several changes occur in the maternal cardiovascular system during pregnancy. These changes produce a considerable stress in this system, especially during the third trimester, which can be increased in presence of some risk factors. The aims of this study were, to assess the maternal cardiac adaptations in a specific exercise program; its safety on the maternal cardiovascular system and pregnancy outcomes; and its effectiveness in the control of cardiovascular risk factors. Material and methods: A randomized controlled trial was designed. 151 healthy pregnant women were assessed by an echocardiography and electrocardiography at 20 and 34 weeks of gestation. A total of 89 pregnant women participated in a physical exercise program (EG) from the first to the third trimester of pregnancy. It consisted of 25-30 minutes of aerobic conditioning (55-60% of their heart rate reserve), general and specific strength exercises, and a pelvic floor muscles training; 3 times per weeks during 55-60 minutes per session. Pregnant women randomized allocated to the control group (CG) remained sedentary during pregnancy. The study was approved by the Research Ethics Committee of Hospital Universitario de Fuenlabrada. Results: Baseline characteristics were similar between groups. Difference from the CG, pregnant women from the EG prevented the significant decrease of the cardiac output index, between the 2nd and 3rd trimester of pregnancy, and preserved the normal left ventricular pattern; whereas in the CG shifted to concentric remodeling pattern. At 20 weeks, women in the EG had significant lower heart rate (CG: 79,56±10,76 vs. EG: 76,05±9,34; p=0,04), systolic blood pressure (CG: 110,19±10,23 vs. EG: 106,04±12,06; p=0,03); diastolic blood pressure (CG: 64,56±7,88 vs. EG: 61,81±7,15; p=0,03); isovolumetric relaxation time (GC: 72,94±14,71 vs. GE: 67,05±16,48; p=0,04); and a higher deceleration time of E Wave (GC: 142,09±39,11 vs. GE: 162,10±48,59; p=0,01). At 34 weeks, the EG had a significant higher stroke volume (CG: 51,13±11,85 vs. EG: 56,21±12,79 p=0,04), early filling of left ventricular (E) (CG: 78,38±14,07 vs. EG: 85,30±16,62; p=0,02) and deceleration time of E wave (CG: 130,35±37,11 vs. EG:146,61±43,40; p=0,04). Conclusion: Physical regular exercise program during pregnancy may produce positive maternal cardiovascular adaptations during the third trimester of pregnancy. In addition, it helps to control the cardiovascular risk factors without altering maternal and fetus health.
Resumo:
The study objective was to determine whether the ‘cardiac decompensation score’ could identify cardiac decompensation in a patient with existing cardiac compromise managed with intraaortic balloon counterpulsation (IABP). A one-group, posttest-only design was utilised to collect observations in 2003 from IABP recipients treated in the intensive care unit of a 450 bed Australian, government funded, public, cardiothoracic, tertiary referral hospital. Twenty-three consecutive IABP recipients were enrolled, four of whom died in ICU (17.4%). All non-survivors exhibited primarily rising scores over the observation period (p < 0.001) and had final scores of 25 or higher. In contrast, the maximum score obtained by a survivor at any time was 15. Regardless of survival, scores for the 23 participants were generally decreasing immediately following therapy escalation (p = 0.016). Further reflecting these changes in patient support, there was also a trend for scores to move from rising to falling at such treatment escalations (p = 0.024). This pilot study indicates the ‘cardiac decompensation score’ to accurately represent changes in heart function specific to an individual patient. Use of the score in conjunction with IABP may lead to earlier identification of changes occurring in a patient's cardiac function and thus facilitate improved IABP outcomes.
Resumo:
BACKGROUND: Heart failure is characterized by abnormalities in beta-adrenergic receptor (betaAR) signaling, including increased level of myocardial betaAR kinase 1 (betaARK1). Our previous studies have shown that inhibition of betaARK1 with the use of the Gbetagamma sequestering peptide of betaARK1 (betaARKct) can prevent cardiac dysfunction in models of heart failure. Because inhibition of betaARK activity is pivotal for amelioration of cardiac dysfunction, we investigated whether the level of betaARK1 inhibition correlates with the degree of heart failure. METHODS AND RESULTS: Transgenic (TG) mice with varying degrees of cardiac-specific expression of betaARKct peptide underwent transverse aortic constriction (TAC) for 12 weeks. Cardiac function was assessed by serial echocardiography in conscious mice, and the level of myocardial betaARKct protein was quantified at termination of the study. TG mice showed a positive linear relationship between the level of betaARKct protein expression and fractional shortening at 12 weeks after TAC. TG mice with low betaARKct expression developed severe heart failure, whereas mice with high betaARKct expression showed significantly less cardiac deterioration than wild-type (WT) mice. Importantly, mice with a high level of betaARKct expression had preserved isoproterenol-stimulated adenylyl cyclase activity and normal betaAR densities in the cardiac membranes. In contrast, mice with low expression of the transgene had marked abnormalities in betaAR function, similar to the WT mice. CONCLUSIONS: These data show that the level of betaARK1 inhibition determines the degree to which cardiac function can be preserved in response to pressure overload and has important therapeutic implications when betaARK1 inhibition is considered as a molecular target.
Resumo:
El compromiso del sistema cardiovascular es frecuente en los pacientes en estado crítico, por tanto la monitorización hemodinámica es esencial para un tratamiento apropiado dirigido a objetivos terapéuticos en este grupo de pacientes. La monitorización hemodinámica del gasto cardíaco y la estimación del volumen intravascular son fundamentales para el manejo de los pacientes pediátricos en estado crítico, la medición del gasto cardíaco es uno de los principales elementos para evaluar la situación hemodinámica y la perfusión tisular de un paciente ayudando a dirigir el tratamiento y a monitorizar la respuesta clínica en pacientes con choque séptico. La hipovolemia es una causa común para la falla circulatoria en pacientes en condición crítica, el encontrar un método confiable para medición de precarga es importante para guiar la administración de líquidos. Tradicionalmente se han utilizado medidas de la volemia asociadas como la presión venosa central (PVC), frecuencia cardiaca (FC), presión arterial (PA) y el gasto urinario. Estos indicadores tienen grandes factores de distracción que hacen que su valor sea limitado y por tanto se tengan que buscar alternativas más confiables. En años recientes se han postulado parámetros dinámicos para la evaluación de la precarga, entre ellos uno de los mas ampliamente estudiado es la medición de la variabilidad de Volumen sistólico (VVS); Este valor se basa en el concepto de que durante la inspiración, la disminución del retorno venoso produce una disminución del Volumen sistólico, lo cual se manifiesta como una disminución en la onda de pulso; Por tanto en una situación de hipovolemia esta diferencia será mayor, dado que será más evidente la disminución del volumen al final de la diástole. En adultos este parámetro se ha convertido en una herramienta útil para evaluar estado de volumen de los pacientes que se encuentran en estado crítico y ha demostrado su utilidad para predecir respuesta a administración de fluidos en diferentes poblaciones de pacientes. En la actualidad no hay estudios en niños que comparen la medición de VVS contra dichas medidas tradicionales de volemia.
Resumo:
Introducción: La sepsis es una de las principales causas de morbilidad y mortalidad en la población pediátrica a nivel mundial, siendo la disminución del gasto cardiaco uno de los principales factores asociados a mortalidad. Se ha planteado la diferencia venoarterial de pCO2 como predictor de la función miocárdica en pacientes con sepsis, sin embargo hasta el momento no hay estudios en la población pediátrica que lo evalúen. Objetivo: Determinar la capacidad predictora y las características operativas de la diferencia venoarterial de pCO2, como predictor de disfunción miocárdica en pacientes pediátricos con sepsis severa y choque séptico. Métodos: Para alcanzar los objetivos del estudio, se llevo a cabo un estudio prospectivo de pruebas diagnósticas. Se realizó ecocardiograma y diferencia venoarterial de pCO2 en cada paciente, posteriormente se calculó las características operativas de la diferencia venoarterial de pCO2 para determinar su utilidad. Resultados: Se incluyeron 71 pacientes. La mediana de la diferencia venoarterial de pCO2 no fue significativamente mayor en los pacientes que tuvieron disfunción cardiaca en el ecocardiograma en comparación con los que no tuvieron disfunción. Se encontró una relación estadísticamente significativa de valores de 1,5 a 2,1 mmHg, como predictor negativo de disfunción miocárdica con una sensibilidad de 100% y una especificidad de 88%. Conclusiones: La diferencia venoarterial de pCO2 requiere de estudios mas extensos para determinar la probabilidad como predictor de disfunción miocárdica en pacientes pediátricos con sepsis severa y choque séptico, incluso cuando otros biomarcadores se encuentran dentro de límites normales.
Resumo:
JUSTIFICATIVA E OBJETIVOS: Não existem estudos que relatem as repercussões renais determinadas pela injeção de doses elevadas de clonidina no espaço peridural. O objetivo do estudo foi avaliar os efeitos hemodinâmicos e renais determinados pela injeção de doses elevadas de clonidina no espaço peridural do cão. MÉTODO: Vinte animais anestesiados com tiopental sódico e fentanil foram distribuídos aleatoriamente e de forma duplamente encoberta em dois grupos: Grupo 1 ou placebo (n = 10), que recebeu 0,2 mL.kg-1 de solução fisiológica, e Grupo 2 ou clonidina (n = 10), que recebeu 0,2 mL.kg-1 de uma solução contendo 50 µg.mL-1 de clonidina, no espaço peridural. Foram avaliados os seguintes parâmetros hemodinâmicos: freqüência cardíaca (FC): bat.min-1; pressão arterial média (PAM): mmHg; pressão da artéria pulmonar ocluida (PAOP): mmHg; débito cardíaco (DC): L.min-1; volume sistólico (VS): mL; também, os seguintes parâmetros da função renal foram avaliados: fluxo sangüíneo renal (FSR): mL.min-1; resistência vascular renal (RVR): mmHg.mL-1.min; volume urinário minuto (VUM): mL.min-1; depuração de creatinina (D Cr): mL.min-1; depuração de para-aminohipurato (D PAH): mL.min-1; fração de filtração (FF); depuração de sódio (D Na): mL.min-1; depuração de potássio (D K): mL.min-1; excreção fracionária de sódio (EF Na): %; excreção urinária de sódio (U NaV): µEq.min-1; excreção urinária de potássio (U K V): µEq.min-1. O experimento consistiu em três momentos de 20 minutos cada. Os dados foram coletados aos 10 minutos de cada momento e a diurese, no início e no final de cada momento. Ao término de M1, a clonidina ou a solução fisiológica foi administrada no espaço peridural. Após período de 20 minutos iniciou-se M2 e, em seguida, M3. RESULTADOS: A clonidina na dose de 10 µg.kg-1 no espaço peridural do cão promoveu alterações significativas, com diminuições da freqüência cardíaca e do débito cardíaco e aumento da relação depuração de para-aminohipurato de sódio/débito cardíaco. CONCLUSÕES: Nas condições realizadas e nas doses empregadas, pode-se concluir que a clonidina não promoveu alteração da função renal, mas diminuiu valores hemodinâmicos (freqüência e débito cardíaco).
Resumo:
JUSTIFICATIVA E OBJETIVOS: A insuficiência renal aguda peri-operatória é responsável por elevada taxa de morbidade e mortalidade. Os fármacos alfa2-agonistas aumentam o débito urinário e promovem boa estabilidade hemodinâmica nesse período. O objetivo desta pesquisa foi estudar os efeitos renais e sobre a concentração plasmática do hormônio antidiurético (HAD) provocados pela dexmedetomidina no cão anestesiado. MÉTODO: Trinta e seis cães adultos, anestesiados com propofol, fentanil e isoflurano, foram divididos aleatoriamente em três grupos que receberam, de modo encoberto: G1 - injeção de 20 mL de solução de cloreto de sódio a 0,9%, em 10 minutos, seguida de injeção de 20 mL da mesma solução em uma hora; G2 - injeção de 20 mL de solução de cloreto de sódio a 0,9% contendo dexmedetomidina (1 µg.kg-1), em 10 minutos, seguida de injeção de 20 mL da mesma solução, com a mesma dose de dexmedetomidina (1 µg.kg-1), em uma hora e G3 - injeção de 20 mL de solução de cloreto de sódio a 0,9% contendo dexmedetomidina (2 µg.kg-1) em 10 minutos, seguida de injeção de 20 mL da mesma solução, com a mesma dose de dexmedetomidina (2 µg.kg-1), em uma hora. As variáveis renais, hemodinâmicas e a concentração plasmática do HAD foram estudadas em quatro momentos: M1 (controle) - imediatamente após o período de estabilização; M2 - após a injeção inicial de 20 mL da solução em estudo, em 10 minutos, coincidindo com o início da injeção da mesma solução, em uma hora; M3 - 30 minutos após M2 e M4 - 30 minutos após M3. RESULTADOS: A dexmedetomidina reduziu a freqüência cardíaca e promoveu estabilidade hemodinâmica, mantendo constante o débito cardíaco. Houve elevação do débito urinário no G2 e G3, em comparação com o G1. A osmolalidade urinária no G2 e G3 foi menor no M3 e M4 em relação ao M1 e M2. A depuração de água livre aumentou no G3. A concentração plasmática do HAD diminuiu no G3, apresentando valores mais baixos que os observados no G1 e G2 em M2 e M4. CONCLUSÕES: Os cães anestesiados com baixas doses de dexmedetomidina promovem diurese hídrica por inibir a secreção do hormônio antidiurético, havendo potencial para proteção renal em eventos isquêmicos.
Resumo:
Objective: the objectives were to analyze the cardiac effects of exposure to tobacco smoke (ETS), for a period of 30 days, alone and in combination with beta-carotene supplementation (BC). Research methods and procedures: Rats were allocated into: Air (control, n = 13); Air + BC (n = 11); ETS (n = 11); and BC + ETS (n = 9). In Air + BC and BC + ETS, 500 mg of BC were added to the diet. After three months of randomization, cardiac structure and function were assessed by echocardiogram. After that, animals were euthanized and morphological data were analyzed post-morten. One-way and two-way ANOVA were used to assess the effects of ETS, BC and the interaction between ETS and BC on the variables. Results: ETS presented smaller cardiac output (0.087 +/- 0.001 vs. 0.105 +/- 0.004 l/min; p = 0.007), higher left ventricular diastolic diameter (19.6 +/- 0.5 vs. 18.0 +/- 0.5 mm/kg; p = 0.024), higher left ventricular (2.02 +/- 0.05 vs. 1.70 +/- 0.03 g/kg; p < 0.001) and atrium (0.24 +/- 0.01 vs. 0.19 +/- 0.01 g/kg; p = 0.003) weight, adjusted to body weight of animals, and higher values of hepatic lipid hydroperoxide (5.32 +/- 0.1 vs. 4.84 +/- 0.1 nmol/g tissue; p = 0.031) than Air. However, considering those variables, there were no differences between Air and BC + ETS (0.099 +/- 0.004 l/min; 19.0 +/- 0.5 mm/kg; 1.83 +/- 0.04 g/kg; 0.19 +/- 0.01 g/kg; 4.88 +/- 0.1 nmol/g tissue, respectively; p > 0.05). Ultrastructural alterations were found in ETS: disorganization or loss of myofilaments, plasmatic membrane infolding, sarcoplasm reticulum dilatation, polymorphic mitochondria with swelling and decreased cristae. In BC + ETS, most fibers showed normal morphological aspects. Conclusion: One-month tobacco-smoke exposure induces functional and morphological cardiac alterations and BC supplementation attenuates this ventricular remodeling process.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)