990 resultados para Optic disc size
Resumo:
BACKGROUND: Drusen of the optic disc are associated with slowly progressive optic neuropathy, characterized by accumulation of acellular laminated concretions in the prelaminar portion of the optic nerve. Papillary hemorrhages and vascular shunts have been reported with disc drusen but their frequency and clinical significance is not well known. METHODS: Retrospective study of fundus photographs of 116 patients with disc drusen referred to the National Hospital for Neurology and Neurosurgery, London, between 1965 and 1991. RESULTS: Hemorrhages were found in 23 eyes from 16/116 (13.8%) patients. Most cases (68.8%, 11/16 cases) occurred in patients with buried drusen, and most hemorrhages were deeply located. Vascular shunts were present in 6.9% (8/116 cases), most frequently in patients with exposed drusen (6/8 cases), most being of the venous type (7/8 cases). DISCUSSION: Vascular anomalies are not rare in disc drusen, as 20.7% (24/116 cases) of our patients presented either disc hemorrhages or shunt vessels. Their presence supports the hypothesis of the slowly progressive nature of disc drusen and the more advanced stage of optic neuropathy in such eyes.
Resumo:
BACKGROUND/AIM: Elevated plasma homocysteine is a newly identified vascular risk factor among patients under age 55 years with cerebrovascular, cardiovascular, or peripheral vascular disease. This study sought to evaluate retrospectively the plasma homocysteine status among healthy younger patients with ischaemic optic disc disease. METHODS: 12 non-diabetic patients who had been diagnosed with non-arteritic anterior ischaemic optic neuropathy (NAION) before the age of 50 years were identified from chart review. None had experienced previous ischaemic cerebrovascular, cardiovascular, or peripheral vascular events. Plasma homocysteine, CBC, renal function, vitamin B6, vitamin B12, and folate levels were sampled in the fasting state. RESULTS: Two of 12 patients (17%) had hyperhomocysteinaemia. Both had experienced NAION in both eyes with recurrent episodes. Neither patient was hypertensive nor had a smoking history. One of these two patients had mild hypercholesterolaemia which did not warrant medication. CONCLUSIONS: Elevated plasma homocysteine may be associated with NAION. An evaluation for hyperhomocysteinaemia should be considered in patients with NAION who do not have the typical risk factor such as older age, diabetes, hypertension, or tobacco use. It should also be considered in young patients with bilateral or recurrent attacks of NAION.
Resumo:
Optic neuritis is an occasional complication of vaccination. Visual loss can be unilateral or bilateral, and most patients recover substantially without treatment. The presumptive mechanism is an immune-mediated demyelinating injury of the optic nerve. We report two patients who had permanent visual loss following influenza vaccination. Their pattern of visual loss, segmental optic disc changes, and failure of visual recovery were atypical for demyelinating optic neuritis and reminiscent of a primary ischemic injury to the optic nerve. We speculate that an immune complex-mediated vasculopathy following vaccination can cause anterior ischemic optic neuropathy. Clinicians should be aware of this entity because of the less favorable prognosis for visual recovery in these cases.
Resumo:
Purpose:Coats' disease is a non-hereditary condition characterized by idiopathic retinal telangiectasia, and exudative retinopathy. Although the exudation often spreads from the main areas of telangiectasia, there is a preferential accumulation of exudation in the macular area in Coats' disease. A subfoveal nodule has usually been described in the context of resolution of macular exudates after treatment of peripheral retinal telangiectasis. Nevertheless, a recent reports stressed out an uncommon prominent subfoveal nodule with peripheral exudates as initial presentation of Coats'disease. The purpose of this study was to report the prevalence of this presentation in a cohort of patients. Methods:All consecutive patients with Coats' disease referred to the Jules Gonin Eye Hospital between January 1979 and July 2006 were included. All charts were screened for a clear cut subfoveal circular lesion on fundus photographies at initial presentation. Results:95 patients suffering of Coat's disease were enrolled. 33 out of 95 patients had subtotal or total exudative retinal detachment, which impeded macular examination. 14 out of 62 (22.6%) resting patients presented with a clear cut prominent circular subfoveal lesion at initial presentation. All patients had unilateral disease. Mean age was 5.6 ± 3.5 year old at initial presentation. There were 4 females and 10 males. Pigmentation and size of the nodule were not homogenous. Mean diameter was 1.1 ± 0.5 optic disc diameter. Conclusions:The present study shows that subfoveal nodule is not such a rare primary presentation of Coats' disease in contrast to what it has been previously reported in the literature. Thus the initial finding of prominent subfoveal nodule associated with peripheral retinal findings made the diagnosis of Coats' disease highly likely.Physicians should be aware that a proeminent subfoveal nodule is a common initial presentation of Coats' disease as it can be confused clinically with Retinoblastoma.
Resumo:
BACKGROUND: Polycythemia vera (PV) is a hemopoetic disorder. Apparently, although thrombosis accounts for the majority of morbidity, AION has not been associated with PV so far. PATIENT AND FINDINGS: A 63 y-old woman with PV was hospitalized because of acute liver failure. She also experienced bilateral painless loss of vision. Bilateral, pale optic disc swelling with flame-like hemorrhages, more pronounced in the right eye, constricted visual fields, and relative afferent papillary defect (RAPD) on the right side were present. Computer tomography scan revealed no signs of intraorbital pathology, elevated intracranial pressure or hemorrhages. CLINICAL COURSE: We interpreted the findings as AION associated with the hyperviscosity syndrome. Liver transplantation had to be carried out in the next days. Three weeks later, vision improved slightly, but RAPD persisted, and disc pallor developed in both eyes. The patient died two months later. DISCUSSION: Central retinal artery and vein occlusions have been described as complications of Essential thrombocythemia, but not of PV. We observed a rare case of bilateral neuropathy suggestive of AION. This condition has so far not been associated with PV.
Resumo:
Suppression of oxidative injury by viral-mediated transfer of the human catalase gene was tested in the optic nerves of animals with experimental allergic encephalomyelitis (EAE). EAE is an inflammatory autoimmune disorder of primary central nervous system demyelination that has been frequently used as an animal model for the human disease multiple sclerosis (MS). The optic nerve is a frequent site of involvement common to both EAE and MS. Recombinant adeno-associated virus containing the human gene for catalase was injected over the right optic nerve heads of SJL/J mice that were simultaneously sensitized for EAE. After 1 month, cell-specific catalase activity, evaluated by quantitation of catalase immunogold, was increased approximately 2-fold each in endothelia, oligodendroglia, astrocytes, and axons of the optic nerve. Effects of catalase on the histologic lesions of EAE were measured by computerized analysis of the myelin sheath area (for demyelination), optic disc area (for optic nerve head swelling), extent of the cellular infiltrate, extravasated serum albumin labeled by immunogold (for blood–brain barrier disruption), and in vivo H2O2 reaction product. Relative to control, contralateral optic nerves injected with the recombinant virus without a therapeutic gene, catalase gene inoculation reduced demyelination by 38%, optic nerve head swelling by 29%, cellular infiltration by 34%, disruption of the blood–brain barrier by 64%, and in vivo levels of H2O2 by 61%. Because the efficacy of potential treatments for MS are usually initially tested in the EAE animal model, this study suggests that catalase gene delivery by using viral vectors may be a therapeutic strategy for suppression of MS.
Resumo:
Trabalho Final do Curso de Mestrado Integrado em Medicina, Faculdade de Medicina, Universidade de Lisboa, 2014
Resumo:
PURPOSE. It is well documented that myopia is associated with an increase in axial length or, more specifically, in vitreous chamber depth. Whether the transverse dimensions of the eye also increase in myopia is relevant to further understanding of its development. METHODS. The posterior retinal surface was localized in two-dimensional space in both eyes of young adult white and Taiwanese-Chinese iso- and anisomyopes (N = 56), from measured keratometry, A-scan ultrasonography, and central and peripheral refraction (±35°) data, with the aid of a computer modeling program designed for this purpose. Anisomyopes had 2 D or more interocular difference in their refractive errors, with mean values in their more myopic eyes of -5.57 D and in their less myopic eyes of -3.25 D, similar to the means of the two isomyopic groups. The derived retinal contours for the more and less myopic eyes were compared by way of investigating ocular shape changes that accompany myopia, in the posterior region of the vitreous chamber. The presence and size of optic disc crescents were also investigated as an index of retinal stretching in myopia. RESULTS. Relative to the less myopic eyes of anisometropic subjects, the more myopic eyes were more elongated and also distorted into a more prolate shape in both the white and Chinese groups. However, the Chinese eyes showed a greater and more uniform relative expansion of the posterior retinal surface in their more myopic eyes, and this was associated with larger optic disc crescents. The changes in the eyes of whites displayed a nasal-temporal axial asymmetry, reflecting greater enlargement of the nasal retinal sector. CONCLUSIONS. Myopia is associated with increased axial length and a prolate shape. This prolate shape is consistent with the proposed idea that axial and transverse dimensions of the eye are regulated differently. The observations that ocular shape changes are larger but more symmetrical in Chinese eyes than in eyes of whites warrant further investigation.
Resumo:
This article considers the clinical symptoms associated with hereditary optic atrophy and reviews recent progress in our understanding the genetics of the disorder. The major genes linked to optic atrophy are identified and how defects in these genes could lead to the optic disc pathology is discussed.
Resumo:
Purpose: Tilted disc syndrome has been described to be associated with obliquely directed long axis of the disc, oblique direction of vessels, retinal pigment epithelial conus, hypoplasia of retina, visual field defects and myopic astigmatism. This prospective study looks at corneal astigmatism in eyes with a tilted optic disc. Refractive errors in these eyes were also analyzed. Methods: Patients with tilted optic discs were identified prospectively by clinical evaluation (BI, VK). All the patients with obliquely directed long axis of the disc, oblique direction of vessels and retinal pigment epithelial conus were included in the study. Best corrected visual acuity, slit-lamp examination, optic disc measurements, keratometry and refraction were recorded. Results: Twenty four patients (41 eyes) were recruited for the study. Eighteen (75%) patients had bilateral tilted optic discs. Eighteen patients (75%) were females and six (25%) were males. The mean age was 62 years(range 9 – 86 years). 76% of the patients were myopic and 24% hypermetropic. The mean spherical equivalent was –7.49 dioptres (SD 1.7D, range +6D to -17D). The mean corneal astigmatism was 1.09D (SD 0.9D, range 0.25D to 3.80D). The 6 patients who had unilateral, untilted discs were used as a control group to compare their mean corneal astigmatism (1.32 D) with the rest. Student "t" test was performed. ("p" = 0.49). Conclusions: In our study, tilted disc syndrome was found to be largely bilateral and more commonly seen in females. Myopia was the commonest refractive error associated with this clinical condition. However, 24% of patients in this series were hypermetropic. No correlation between the tilting of the optic disc and significant corneal astigmatism was noted as previously reported.
Resumo:
OBJETIVO: Desenvolver a instrumentação e o "software" para topografia de córnea de grande-ângulo usando o tradicional disco de Plácido. O objetivo é permitir o mapeamento de uma região maior da córnea para topógrafos de córnea que usem a técnica de Plácido, fazendo-se uma adaptação simples na mira. MÉTODOS: Utilizando o tradicional disco de Plácido de um topógrafo de córnea tradicional, 9 LEDs (Light Emitting Diodes) foram adaptados no anteparo cônico para que o paciente voluntário pudesse fixar o olhar em diferentes direções. Para cada direção imagens de Plácido foram digitalizadas e processadas para formar, por meio de algoritmo envolvendo elementos sofisticados de computação gráfica, um mapa tridimensional completo da córnea toda. RESULTADOS: Resultados apresentados neste trabalho mostram que uma região de até 100% maior pode ser mapeada usando esta técnica, permitindo que o clínico mapeie até próximo ao limbo da córnea. São apresentados aqui os resultados para uma superfície esférica de calibração e também para uma córnea in vivo com alto grau de astigmatismo, mostrando a curvatura e elevação. CONCLUSÃO: Acredita-se que esta nova técnica pode propiciar a melhoria de alguns processos, como por exemplo: adaptação de lentes de contato, algoritmos para ablações costumizadas para hipermetropia, entre outros.
Resumo:
Purpose The aim of this study was to test the correlation between Fourier-domain (FD) optical coherence tomography (OCT) macular and retinal nerve fibre layer (RNFL) thickness and visual field (VF) loss on standard automated perimetry (SAP) in chiasmal compression. Methods A total of 35 eyes with permanent temporal VF defects and 35 controls underwent SAP and FD-OCT (3D OCT-1000; Topcon Corp.) examinations. Macular thickness measurements were averaged for the central area and for each quadrant and half of that area, whereas RNFL thickness was determined for six sectors around the optic disc. VF loss was estimated in six sectors of the VF and in the central 16 test points in the VF. The correlation between VF loss and OCT measurements was tested with Spearman`s correlation coefficients and with linear regression analysis. Results Macular and RNFL thickness parameters correlated strongly with SAP VF loss. Correlations were generally stronger between VF loss and quadrantic or hemianopic macular thickness than with sectoral RNFL thickness. For the macular parameters, we observed the strongest correlation between macular thickness in the inferonasal quadrant and VF loss in the superior temporal central quadrant (rho=0.78; P<0.001) whereas for the RNFL parameters the strongest correlation was observed between the superonasal optic disc sector and the central temporal VF defect (rho=0.60; P<0.001).
Resumo:
PURPOSE: To evaluate the impact of atypical retardation patterns (ARP) on detection of progressive retinal nerve fiber layer (RNFL) loss using scanning laser polarimetry with variable corneal compensation (VCC). DESIGN: Observational cohort study. METHODS: The study included 377 eyes of 221 patients with a median follow-up of 4.0 years. Images were obtained annually with the GDx VCC (Carl Zeiss Med, itec Inc, Dublin, California, USA), along with optic disc stereophotographs and standard automated perimetry (SAP) visual fields. Progression was determined by the Guided Progression Analysis software for SAP and by masked assessment of stereophotographs by expert graders. The typical scan score (TSS) was used to quantify the presence of ARPs on GDx VCC images. Random coefficients models were used to evaluate the relationship between ARP and RNFL thickness measurements over time. RESULTS: Thirty-eight eyes (10%) showed progression over time on visual fields, stereophotographs, or both. Changes in TSS scores from baseline were significantly associated with changes in RNFL thickness measurements in both progressing and nonprogressing eyes. Each I unit increase in TSS score was associated with a 0.19-mu m decrease in RNFL thickness measurement (P < .001) over time. CONCLUSIONS: ARPs had a significant effect on detection of progressive RNFL loss with the GDx VCC. Eyes with large amounts of atypical patterns, great fluctuations on these patterns over time, or both may show changes in measurements that can appear falsely as glaucomatous progression or can mask true changes in the RNFL. (Am J Ophthalmol 2009;148:155-163. (C) 2009 by Elsevier Inc. All rights reserved.)
Resumo:
Objective: To determine intraocular pressure (IOP)-dependent and IOP-independent variables associated with visual field (VF) progression in treated glaucoma. Design: Retrospective cohort of the Glaucoma Progression Study. Methods: Consecutive, treated glaucoma patients with repeatable VF loss who had 8 or more VF examinations of either eye, using the Swedish Interactive Threshold Algorithm (24-2 SITA-Standard, Humphrey Field Analyzer II; Carl Zeiss Meditec, Inc, Dublin, California), during the period between January 1999 and September 2009 were included. Visual field progression was evaluated using automated pointwise linear regression. Evaluated data included age, sex, race, central corneal thickness, baseline VF mean deviation, mean follow-up IOP, peak IOP, IOP fluctuation, a detected disc hemorrhage, and presence of beta-zone parapapillary atrophy. Results: We selected 587 eyes of 587 patients (mean [SD] age, 64.9 [13.0] years). The mean (SD) number of VFs was 11.1 (3.0), spanning a mean (SD) of 6.4 (1.7) years. In the univariable model, older age (odds ratio [OR], 1.19 per decade; P = .01), baseline diagnosis of exfoliation syndrome (OR, 1.79; P = .01), decreased central corneal thickness (OR, 1.38 per 40 mu m thinner; P < .01), a detected disc hemorrhage (OR, 2.31; P < .01), presence of beta-zone parapapillary atrophy (OR, 2.17; P < .01), and all IOP parameters (mean follow-up, peak, and fluctuation; P < .01) were associated with increased risk of VF progression. In the multivariable model, peak IOP (OR, 1.13; P < .01), thinner central corneal thickness (OR, 1.45 per 40 mu m thinner; P < .01), a detected disc hemorrhage (OR, 2.59; P < .01), and presence of beta-zone parapapillary atrophy (OR, 2.38; P < .01) were associated with VF progression. Conclusions: IOP-dependent and IOP-independent risk factors affect disease progression in treated glaucoma. Peak IOP is a better predictor of progression than is IOP mean or fluctuation.
Resumo:
PURPOSE. To evaluate the effect of disease severity on the diagnostic accuracy of the Cirrus Optical Coherence Tomograph (Cirrus HD-OCT; Carl Zeiss Meditec, Inc., Dublin, CA) for glaucoma detection. METHODS. One hundred thirty-five glaucomatous eyes of 99 patients and 79 normal eyes of 47 control subjects were recruited from the longitudinal Diagnostic Innovations in Glaucoma Study (DIGS). The severity of the disease was graded based on the visual field index (VFI) from standard automated perimetry. Imaging of the retinal nerve fiber layer (RNFL) was obtained using the optic disc cube protocol available on the Cirrus HD-OCT. Pooled receiver operating characteristic (ROC) curves were initially obtained for each parameter of the Cirrus HD-OCT. The effect of disease severity on diagnostic performance was evaluated by fitting an ROC regression model, with VFI used as a covariate, and calculating the area under the ROC curve (AUCs) for different levels of disease severity. RESULTS. The largest pooled AUCs were for average thickness (0.892), inferior quadrant thickness (0.881), and superior quadrant thickness (0.874). Disease severity had a significant influence on the detection of glaucoma. For the average RNFL thickness parameter, AUCs were 0.962, 0.932, 0.886, and 0.822 for VFIs of 70%, 80%, 90%, and 100%, respectively. CONCLUSIONS. Disease severity had a significant effect on the diagnostic performance of the Cirrus HD-OCT and thus should be considered when interpreting results from this device and when considering the potential applications of this instrument for diagnosing glaucoma in the various clinical settings. (Invest Ophthalmol Vis Sci. 2010;51:4104-4109) DOI:10.1167/iovs.094716