965 resultados para Objective measurement


Relevância:

60.00% 60.00%

Publicador:

Resumo:

The purpose of this paper is to conduct a review of studies on cystoid macular edema published in the last seven years. Cystoid macular edema is a major cause of loss of visual acuity. It is the final common pathway of many diseases and can be caused by numerous processes including inflammatory, vascular, adverse drug reactions, retinal dystrophy or intraocular tumors. These processes disrupt the blood-retinal barrier, with fluid extravasation to the macular parenchyma. Imaging tests are essential for both detection and monitoring of this pathology. Fluorescein angiography and autofluorescence show the leakage of liquid from perifoveal vessels into the tissue where it forms cystic spaces. Optical coherence tomography is currently the gold standard technique for diagnosis and monitoring. This allows objective measurement of retinal thickness, which correlates with visual acuity and provides more complete morphological information. Based on the underlying etiology, the therapeutic approach can be either surgical or medical with anti-inflammatory drugs. We found that disruption of the blood-retinal barrier for various reasons is the key point in the pathogenesis of cystoid macular edema, therefore we believe that studies on its treatment should proceed on this path.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Previous investigations employing electropalatography (EPG) have identified articulatory timing deficits in individuals with acquired dysarthria. However, this technology is yet to be applied to the articulatory timing disturbance present in Parkinson's disease (PD). As a result, the current investigation aimed to use EPG to comprehensively examine the temporal aspects of articulation in a group of nine individuals with PD at sentence, word and segment level. This investigation followed on from a prior study (McAuliffe, Ward and Murdoch) and similarly, aimed to compare the results of the participants with PD to a group of aged (n=7) and young controls (n=8) to determine if ageing contributed to any articulatory timing deficits observed. Participants were required to read aloud the phrase I saw a ___ today'' with the EPG palate in-situ. Target words included the consonants /1/, /s/ and /t/ in initial position in both the /i/ and /a/ vowel environments. Perceptual investigation of speech rate was conducted in addition to objective measurement of sentence, word and segment duration. Segment durations included the total segment length and duration of the approach, closure/constriction and release phases of EPG consonant production. Results of the present study revealed impaired speech rate, perceptually, in the group with PD. However, this was not confirmed objectively. Electropalatographic investigation of segment durations indicated that, in general, the group with PD demonstrated segment durations consistent with the control groups. Only one significant difference was noted, with the group with PD exhibiting significantly increased duration of the release phase for /1a/ when compared to both the control groups. It is, therefore, possible that EPG failed to detect lingual movement impairment as it does not measure the complete tongue movement towards and away from the hard palate. Furthermore, the contribution of individual variation to the present findings should not be overlooked.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

* Chronic heart failure (CHF) is found in 1.5%–2.0% of Australians. Considered rare in people aged less than 45 years, its prevalence increases to over 10% in people aged ≥ 65 years. * CHF is one of the most common reasons for hospital admission and general practitioner consultation in the elderly (≥ 70 years). * Common causes of CHF are ischaemic heart disease (present in > 50% of new cases), hypertension (about two-thirds of cases) and idiopathic dilated cardiomyopathy (around 5%–10% of cases). * Diagnosis is based on clinical features, chest x-ray and objective measurement of ventricular function (eg, echocardiography). Plasma levels of B-type natriuretic peptide (BNP) may have a role in diagnosis, primarily as a test for exclusion. Diagnosis may be strengthened by a beneficial clinical response to treatment(s) directed towards amelioration of symptoms. * Management involves prevention, early detection, amelioration of disease progression, relief of symptoms, minimisation of exacerbations, and prolongation of survival.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The contributions in this research are split in to three distinct, but related, areas. The focus of the work is based on improving the efficiency of video content distribution in the networks that are liable to packet loss, such as the Internet. Initially, the benefits and limitations of content distribution using Forward Error Correction (FEC) in conjunction with the Transmission Control Protocol (TCP) is presented. Since added FEC can be used to reduce the number of retransmissions, the requirement for TCP to deal with any losses is greatly reduced. When real-time applications are needed, delay must be kept to a minimum, and retransmissions not desirable. A balance, therefore, between additional bandwidth and delays due to retransmissions must be struck. This is followed by the proposal of a hybrid transport, specifically for H.264 encoded video, as a compromise between the delay-prone TCP and the loss-prone UDP. It is argued that the playback quality at the receiver often need not be 100% perfect, providing a certain level is assured. Reliable TCP is used to transmit and guarantee delivery of the most important packets. The delay associated with the proposal is measured, and the potential for use as an alternative to the conventional methods of transporting video by either TCP or UDP alone is demonstrated. Finally, a new objective measurement is investigated for assessing the playback quality of video transported using TCP. A new metric is defined to characterise the quality of playback in terms of its continuity. Using packet traces generated from real TCP connections in a lossy environment, simulating the playback of a video is possible, whilst monitoring buffer behaviour to calculate pause intensity values. Subjective tests are conducted to verify the effectiveness of the metric introduced and show that the results of objective and subjective scores made are closely correlated.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

When we study the variables that a ffect survival time, we usually estimate their eff ects by the Cox regression model. In biomedical research, e ffects of the covariates are often modi ed by a biomarker variable. This leads to covariates-biomarker interactions. Here biomarker is an objective measurement of the patient characteristics at baseline. Liu et al. (2015) has built up a local partial likelihood bootstrap model to estimate and test this interaction e ffect of covariates and biomarker, but the R code developed by Liu et al. (2015) can only handle one variable and one interaction term and can not t the model with adjustment to nuisance variables. In this project, we expand the model to allow adjustment to nuisance variables, expand the R code to take any chosen interaction terms, and we set up many parameters for users to customize their research. We also build up an R package called "lplb" to integrate the complex computations into a simple interface. We conduct numerical simulation to show that the new method has excellent fi nite sample properties under both the null and alternative hypothesis. We also applied the method to analyze data from a prostate cancer clinical trial with acid phosphatase (AP) biomarker.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objectives: To evaluate the feasibility of a universally delivered CBT-based programme for pupils within a Scottish secondary school setting. Design: A pre-post, within and between groups design was utilised. Setting: Religious Moral Citizenship and Education (RMCE) classes in a Scottish secondary school. Participants: Four (n = 103) classes of third year secondary school pupils were arbitrarily allocated to two conditions: RMCE-as usual (RMCE-AU) controls, and LLTTF intervention. Intervention: Living Life to the Full (LLTTF) is a series of Cognitive Behavioural Therapy (CBT)-based booklets and accompanying 8 classes to improve coping skills. An adolescent version of LLTTF was recently developed. This was delivered over nine weeks by school teachers trained in the approach. Outcome measures: The Strengths and Difficulties Questionnaire, Rosenberg Self-Esteem scale, General Self-Efficacy Scale, and Locus of Control scale were administered at baseline and 9 week follow-up. To determine acceptability and utility of the materials course feedback was gathered weekly from the intervention group and a focus group (n=5) was conducted at 3 month follow up. Results: Outcome measures showed no significant improvement in overall wellbeing of those in the intervention group compared with that of the control group. Weekly feedback suggested that the majority of pupils found the materials useful and relevant. Focus group feedback suggested that pupils found the intervention useful, had utilised strategies in everyday life and would welcome recurring provision of such interventions within the school setting. Conclusions: Universally delivered CBT intervention is acceptable and feasible within the secondary school environment. However, objective measurement using standardised tools does not adequately corroborate qualitative feedback from pupils. Issues relating to measurement, study design and implementation of future interventions are discussed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The water diffusion attributable to concentration gradients is among the main mechanisms of water transport into the asphalt mixture. The transport of small molecules through polymeric materials is a very complex process, and no single model provides a complete explanation because of the small molecule`s complex internal structure. The objective of this study was to experimentally determine the diffusion of water in different fine aggregate mixtures (FAM) using simple gravimetric sorption measurements. For the purposes of measuring the diffusivity of water, FAMs were regarded as a representative homogenous volume of the hot-mix asphalt (HMA). Fick`s second law is generally used to model diffusion driven by concentration gradients in different materials. The concept of the dual mode diffusion was investigated for FAM cylindrical samples. Although FAM samples have three components (asphalt binder, aggregates, and air voids), the dual mode was an attempt to represent the diffusion process by only two stages that occur simultaneously: (1) the water molecules are completely mobile, and (2) the water molecules are partially mobile. The combination of three asphalt binders and two aggregates selected from the Strategic Highway Research Program`s (SHRP) Materials Reference Library (MRL) were evaluated at room temperature [23.9 degrees C (75 degrees F)] and at 37.8 degrees C (100 degrees F). The results show that moisture uptake and diffusivity of water through FAM is dependent on the type of aggregate and asphalt binder. At room temperature, the rank order of diffusivity and moisture uptake for the three binders was the same regardless of the type of aggregate. However, this rank order changed at higher temperatures, suggesting that at elevated temperatures different binders may be undergoing a different level of change in the free volume. DOI: 10.1061/(ASCE)MT.1943-5533.0000190. (C) 2011 American Society of Civil Engineers.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Shrimp is a frequent cause of food allergy. Tropomyosin is the major allergen in shrimp, and it shares homology to tropomyosins from other crustaceans, dust mites, cockroach, and parasites. Objective: The aim of this study was to determine the value of detection of IgE to shrimp tropomyosin in the diagnosis of shrimp allergy. Methods: We have studied 35 patients with asthma, rhinitis, or both who were sensitized to Dermatophagoides pteronyssinus. All subjects underwent skin prick testing in addition to double-blind, placebo-controlled food challenges (DBPCFC); oral open challenges; or both with shrimp. Measurements of IgE to shrimp and shrimp tropomyosin were carried out by means of CAP and chimeric ELISA, respectively. Results: Oral challenges confirmed the diagnosis of shrimp allergy in 7 patients. IgE measurement to shrimp tropomyosin was positive in 71.4% of the patients with shrimp allergy. Of the 28 patients without shrimp allergy, only 7.1% (2/28) had IgE to shrimp tropomyosin compared with 25% (7/28) who had IgE to shrimp and 35.7% (10/28) who had positive skin prick test responses to shrimp. Sensitivity was similar for all 3 methods (71.4%); in contrast, specificity of IgE to shrimp tropomyosin (92.8%) was greater than that of IgE to shrimp (75%) and skin prick testing (64.2%). With regard to diagnostic efficiency, measurement of IgE to shrimp tropomyosin was superior to measurement of IgE to shrimp and skin prick testing (88.5%, 74.2%, and 65.7%, respectively). Conclusion: Use of measurements of IgE to shrimp tropomyosin provided added value to the diagnosis of shrimp allergy. (J Allergy Clin Immunol 2010;125:872-8.)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective To investigate whether standardization of the multiplanar view (SMV) when evaluating the uterus using three-dimensional ultrasonography (3D-US) improves intra-and interobserver reliability and agreement with regard to endometrial measurement. Methods Two-dimensional (2D) and 3D-US was used to measure endometrial thickness by two observers in 30 women undergoing assisted reproduction treatment. Endometrial volume was measured with Virtual Organ Computer-aided AnaLysis (VOCAL (TM)) in the longitudinal (A) and coronal (C) planes using an unmodified multiplanar view (UMV) and a standardized multiplanar view (SMV). Measurement reliability was evaluated by intraclass correlation coefficient (ICC) and agreement was examined using Bland-Altman plots with limits of agreement (LoA). The ease of outlining the endometrial-myometrial interface was compared between the A-and C-planes using subjective assessment. Results Endometrial volume measurements using the SMV and A-plane were more reliable (intra-and interobserver ICCs, 0.979 and 0.975, respectively) than were measurements of endometrial thickness using 2D-US (intra-and interobserver ICCs, 0.742 and 0.702, respectively) or 3D-US (intra-and interobserver ICCs, 0.890 and 0.784, respectively). The LoAs were narrower for SMV than for UMV. Reliability and agreement were not much different between the A- and C-planes. However the observers agreed that delineating the endometrial-myometrial interface using the A-plane was easier (first and second observer, 50.0 and 46.7%, respectively) or `comparable` (50 and 53.3%, respectively), but never more difficult than using the C-plane. Conclusions Endometrial volume measurements are more reliable than endometrial thickness measurements and are best performed using SMV and the A-plane. Copyright (C) 2011 ISUOG. Published by John Wiley & Sons, Ltd.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective To evaluate the reliability of two- and three-dimensional ultrasonographic measurement of the thickness of the lower uterine segment (LUS) in pregnant women by transvaginal and transabdominal approaches. Methods This was a study of 30 pregnant women who bad bad at least one previous Cesarean section and were between 36 and 39 weeks` gestation, with singleton pregnancies in cephalic presentation. Sonographic examinations were performed by two observers using both 4-7-MHz transabdominal and 5-8-MHz transvaginal volumetric probes. LUS measurements were performed using two- and three-dimensional ultrasound, evaluating the entire LUS thickness transabdominally and the LUS muscular thickness transvaginally. Each observer measured the LUS four times by each method. Reliability was analyzed by comparing the mean of the absolute differences, the intraclass correlation coefficients, the 95% limits of agreement and the proportion of differences <1 mm. Results Transvaginal ultrasound provided greater reliability in LUS measurements than did transabdominal ultrasound. The use of three-dimensional ultrasound improved significantly the reliability of the LUS muscular thickness measurement obtained transvaginally. Conclusions Ultrasonographic measurement of the LUS muscular thickness transvaginally appears more reliable than does that of the entire LUS thickness transabdominally. The use of three-dimensional ultrasound should be considered to improve measurement reliability. Copyright (c) 2009 ISUOG. Published by John Wiley & Sons, Ltd.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova da Lisboa para obtenção do grau de Mestre em Engenharia e Gestão Industrial (MEGI)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dissertation to obtain a Master degree in Biotechnology

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE - The aim of our study was to assess the profile of a wrist monitor, the Omron Model HEM-608, compared with the indirect method for blood pressure measurement. METHODS - Our study population consisted of 100 subjects, 29 being normotensive and 71 being hypertensive. Participants had their blood pressure checked 8 times with alternate techniques, 4 by the indirect method and 4 with the Omron wrist monitor. The validation criteria used to test this device were based on the internationally recognized protocols. RESULTS - Our data showed that the Omron HEM-608 reached a classification B for systolic and A for diastolic blood pressure, according to the one protocol. The mean differences between blood pressure values obtained with each of the methods were -2.3 +7.9mmHg for systolic and 0.97+5.5mmHg for diastolic blood pressure. Therefore, we considered this type of device approved according to the criteria selected. CONCLUSION - Our study leads us to conclude that this wrist monitor is not only easy to use, but also produces results very similar to those obtained by the standard indirect method.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To determine technical procedures and criteria used by Brazilian physicians for measuring blood pressure and diagnosing hypertension. METHODS: A questionnaire with 5 questions about practices and behaviors regarding blood pressure measurement and the diagnosis of hypertension was sent to 25,606 physicians in all Brazilian regions through a mailing list. The responses were compared with the recommendations of a specific consensus and descriptive analysis. RESULTS: Of the 3,621 (14.1%) responses obtained, 57% were from the southeastern region of Brazil. The following items were reported: use of an aneroid device by 67.8%; use of a mercury column device by 14.6%; 11.9% of the participants never calibrated the devices; 35.7% calibrated the devices at intervals < 1 year; 85.8% measured blood pressure in 100% of the medical visits; 86.9% measured blood pressure more than once and on more than one occasion. For hypertension diagnosis, 55.7% considered the patient's age, and only 1/3 relied on consensus statements. CONCLUSION: Despite the adequate frequency of both practices, it was far from that expected, and some contradictions between the diagnostic criterion for hypertension and the number of blood pressure measurements were found. The results suggest that, to include the great majority of the medical professionals, disclosure of consensus statements and techniques for blood pressure measurement should go beyond the boundaries of medical events and specialized journals.