955 resultados para Nasal polyps
Resumo:
Background: Deviated nasal septum (DNS) is one of the major causes of nasal obstruction. Polyvinylidene fluoride (PVDF) nasal sensor is the new technique developed to assess the nasal obstruction caused by DNS. This study evaluates the PVDF nasal sensor measurements in comparison with PEAK nasal inspiratory flow (PNIF) measurements and visual analog scale (VAS) of nasal obstruction. Methods: Because of piezoelectric property, two PVDF nasal sensors provide output voltage signals corresponding to the right and left nostril when they are subjected to nasal airflow. The peak-to-peak amplitude of the voltage signal corresponding to nasal airflow was analyzed to assess the nasal obstruction. PVDF nasal sensor and PNIF were performed on 30 healthy subjects and 30 DNS patients. Receiver operating characteristic was used to analyze the DNS of these two methods. Results: Measurements of PVDF nasal sensor strongly correlated with findings of PNIF (r = 0.67; p < 0.01) in DNS patients. A significant difference (p < 0.001) was observed between PVDF nasal sensor measurements and PNIF measurements of the DNS and the control group. A cutoff between normal and pathological of 0.51 Vp-p for PVDF nasal sensor and 120 L/min for PNIF was calculated. No significant difference in terms of sensitivity of PVDF nasal sensor and PNIF (89.7% versus 82.6%) and specificity (80.5% versus 78.8%) was calculated. Conclusion: The result shows that PVDF measurements closely agree with PNIF findings. Developed PVDF nasal sensor is an objective method that is simple, inexpensive, fast, and portable for determining DNS in clinical practice.
Resumo:
This paper presents the design technique that has been adopted for packaging of Polyvinylidene fluoride (PVDF) nasal sensor for biomedical applications. The PVDF film with the dimension of length 10mm, width 5mm and thickness 28 mu m was firmly adhered on one end of plastic base (8mmx5mmx30 mu m) in such a way that it forms a cantilever configuration leaving the other end free for deflection. Now with the leads attached on the surface of the PVDF film, the cantilever configuration becomes the PVDF nasal sensor. For mounting a PVDF nasal sensor, a special headphone was designed, that can fit most of the human head sizes. Two flexible strings are soldered on either side of the headphone. Two identical PVDF nasal sensors were then connected to either side of flexible string of the headphone in such a way that they are placed below the right and left nostrils respectively without disturbing the normal breathing. When a subject wares headphone along with PVDF nasal sensors, two voltage signals due to the piezoelectric property of the PVDF film were generated corresponding to his/her nasal airflow from right and left nostril. The entire design was made compact, so that PVDF nasal sensors along with headphone can be made portable. No special equipment or machines are needed for mounting the PVDF nasal sensors. The time required for packaging of PVDF nasal sensors was less and the approximate cost of the entire assembly (PVDF nasal sensors + headphone) was very nominal.
Resumo:
Objective: The aim of this study is to validate the applicability of the PolyVinyliDene Fluoride (PVDF) nasal sensor to assess the nasal airflow, in healthy subjects and patients with nasal obstruction and to correlate the results with the score of Visual Analogue Scale (VAS). Methods: PVDF nasal sensor and VAS measurements were carried out in 50 subjects (25-healthy subjects and 25 patients). The VAS score of nasal obstruction and peak-to-peak amplitude (Vp-p) of nasal cycle measured by PVDF nasal sensors were analyzed for right nostril (RN) and left nostril (LN) in both the groups. Spearman's rho correlation was calculated. The relationship between PVDF nasal sensor measurements and severity of nasal obstruction (VAS score) were assessed by ANOVA. Results: In healthy group, the measurement of nasal airflow by PVDF nasal sensor for RN and LN were found to be 51.14 +/- 5.87% and 48.85 +/- 5.87%, respectively. In patient group, PVDF nasal sensor indicated lesser nasal airflow in the blocked nostrils (RN: 23.33 +/- 10.54% and LN: 32.24 +/- 11.54%). Moderate correlation was observed in healthy group (r = 0.710, p < 0.001 for RN and r = 0.651, p < 0.001 for LN), and moderate to strong correlation in patient group (r = 0.751, p < 0.01 for RN and r = 0.885, p < 0.0001 for LN). Conclusion: PVDF nasal sensor method is a newly developed technique for measuring the nasal airflow. Moderate to strong correlation was observed between PVDF nasal sensor data and VAS scores for nasal obstruction. In our present study, PVDF nasal sensor technique successfully differentiated between healthy subjects and patients with nasal obstruction. Additionally, it can also assess severity of nasal obstruction in comparison with VAS. Thus, we propose that the PVDF nasal sensor technique could be used as a new diagnostic method to evaluate nasal obstruction in routine clinical practice. (C) 2015 Elsevier Inc. All rights reserved.
Resumo:
A correção de deformidades esqueléticas da face por meio de um tratamento ortodôntico-cirúrgico tornou-se uma opção segura e previsível. Os movimentos ósseos são milimetricamente calculados e executados cirurgicamente, assim como a oclusão é meticulosamente engrenada através dos movimentos ortodônticos. Os efeitos que os tecidos moles sofrem com as cirurgias ortognáticas são, no entanto, menos previsíveis, e apesar do principal objetivo da cirurgia ortognática ser uma melhora funcional, o componente estético é sem dúvida de extrema importância. Em especial, a região de base alar apresenta resultados muito variáveis, a despeito dos bons resultados esqueléticos atingidos. O objetivo deste estudo foi comparar 2 diferentes tipos de sutura utilizados na região de base do nariz, e observar qual tipo apresenta um resultado que melhor acompanhe os movimentos realizados pelo tecido esquelético. Trinta e cinco pacientes foram aleatoriamente distribuídos em 2 grupos. O grupo 1 funcionou como controle e os pacientes receberam a plicatura nasal intra-oral, que é o tipo de plicatura nasal mais descrito na literatura. Já os pacientes do grupo 2 receberam plicatura nasal extra-oral. Para análise estatística foram calculadas as médias e desvios padrões dos grupos, e a hipótese nula de que não havia diferença entre os 2 grupos foi testata com o teste T de Student. Em ambos os grupos ocorreu um alargamento da base do nariz, porém a média de alargamento do grupo 1 foi de 2,50 milímetros (mm), enquanto que a média de alargamento do grupo 2 foi de 1,26 mm. Além disso, o desvio padrão foi menor para o grupo 2, e a hipótese nula foi rejeitada (p<0,05), demonstrando que a diferença entre os grupos foi estatisticamente significativa. Pôde-se concluir que quando objetiva-se um controle mais previsível e rigoroso da base do nariz, a plicatura nasal extra-oral cumprirá melhor esta função.
Resumo:
Projeto de Pós-Graduação/Dissertação apresentado à Universidade Fernando Pessoa como parte dos requisitos para obtenção do grau de Mestre em Ciências Farmacêuticas
Resumo:
Ascorbic acid (AA) is thought to be an important antioxidant in the respiratory tract, whose regulation is yet to be fully characterized. We investigated whether AA in respiratory tract lining fluids (RTLFs) can be augmented by oral supplementation with AA. Plasma, nasal lavage fluids (NLFs), induced sputum (IS), and saliva were analyzed for AA immediately before and 2 h after ingestion of 2 g of AA in 13 healthy subjects. Concentrations of AA (median and range) were 52.5 (16.0-88.5), 2.4 (0.18-4.66), 2.4 (0.18-6.00), and 0.55 (0.18-18.90) micromol/l, respectively. Two hours after ingestion of AA, plasma AA increased 2-fold (p = .004), NLF AA increased 3-fold (p = .039), but IS and saliva AA did not increase. As AA concentrations in saliva and tracheobronchial secretions were low compared with other common extracellular components (such as urate), we evaluated the fate of AA in these fluids. Addition of AA to freshly obtained saliva or IS resulted in rapid depletion, which could be largely prevented or reversed by sodium azide or dithiothreitol. These findings suggest that oxidant-producing systems in saliva and airway secretions, such as heme peroxidases and other oxidizing substances, rapidly consume AA. Whereas oral supplementation resulted in detectable increases of AA in NLFs, its levels in tracheobronchial lining fluid, as measured by IS, were unaffected and remained relatively low, suggesting that AA may play a less significant antioxidant role in this compartment as compared with most other extracellular compartments.
Resumo:
Background The Allergic Rhinitis Clinical Investigator Collaborative (AR-CIC) uses a Nasal Allergen Challenge (NAC) model to study the pathophysiology of AR and provides proof of concept for novel therapeutics. The NAC model needs to ensure optimal participant qualification, allergen challenge, clinical symptoms capture and biological samples collection. Repeatability of the protocol is key to ensuring unbiased efficacy analysis of novel therapeutics. The effect of allergen challenge on IL-33 gene expression and its relation to IL1RL1 receptor and cytokine secretion was investigated. Methods Several iterations of the NAC protocol was tested, comparing variations of qualifying criteria based on the Total Nasal Symptom Score (TNSS) and Peak Nasal Inspiratory Flow (PNIF). The lowest allergen concentration was delivered and TNSS and PNIF recorded 15 minutes later. Participants qualified if the particular criteria for the protocol were met, otherwise the next higher allergen concentration (4-fold increase), was administered until the targets were reached. Participants returned for a NAC visit and received varying allergen challenge concentrations depending on the protocol, TNSS/PNIF were recorded at 15 minutes, 30 minutes, 1 hour, and hourly up to 12 hours, a 24 hour time point was added in later iterations. Repeatability was evaluated using a 3-4week interval between screening, NAC1, and NAC2 visits. Various biomarker samples were collected. Results A combined TNSS and PNIF criterion was more successful in qualifying participants. The cumulative allergen challenge (CAC) protocol proved more reliable in producing a robust clinical and biomarker response. Repeatability of the CAC protocol was achieved with a 3-week interval between visits, on a clinical and biological basis. IL-33 cytokine is an important biomarker in initiating the inflammatory response in AR in humans. IL-33 and IL1RL1 expression might employ a negative feedback mechanism in human nasal epithelial cells. Comparing the clinical and biological response to ragweed vs cat allergen challenge, proved the CAC protocol’s suitability for use employing different allergens. Conclusion The AR-CIC’s CAC protocol is an effective method of studying AR, capable of generating measurable and repeatable clinical and biomarker responses, enabling better understanding of AR pathophysiology and ensuring that any change would be purely due to medication under investigation in a clinical trial setting.
Resumo:
Pulmonary fluid clearance is regulated by the active transport of Na+ and Cl- through respiratory epithelial ion channels. Ion channel dysfunction contributes to the pathogenesis of various pulmonary fluid disorders including high-altitude pulmonary edema (HAPE) and neonatal respiratory distress syndrome (RDS). Nasal potential difference (NPD) measurement allows an in vivo investigation of the functionality of these channels. This technique has been used for the diagnosis of cystic fibrosis, the archetypal respiratory ion channel disorder, for over a quarter of a century. NPD measurements in HAPE and RDS suggest constitutive and acquired dysfunction of respiratory epithelial Na+ channels. Acute lung injury (ALI) is characterized by pulmonary edema due to alveolar epithelial-interstitial-endothelial injury. NPD measurement may enable identification of critically ill ALI patients with a susceptible phenotype of dysfunctional respiratory Na+ channels and allow targeted therapy toward Na+ channel function. text of link
Resumo:
We performed comprehensive genome-wide gene expression profiling (GEP) of extranodal nasal-type natural killer/T-cell lymphoma (NKTL) using formalin-fixed, paraffin-embedded tissue (n = 9) and NK cell lines (n = 5) in comparison with normal NK cells, with the objective of understanding the oncogenic pathways involved in the pathogenesis of NKTL and to identify potential therapeutic targets. Pathway and network analysis of genes differentially expressed between NKTL and normal NK cells revealed significant enrichment for cell cycle-related genes and pathways, such as PLK1, CDK1, and Aurora-A. Furthermore, our results demonstrated a pro-proliferative and anti-apoptotic phenotype in NKTL characterized by activation of Myc and nuclear factor kappa B (NF-kappa B), and deregulation of p53. In corroboration with GEP findings, a significant percentage of NKTLs (n = 33) overexpressed c-Myc (45.4%), p53 (87.9%), and NF-kappa B p50 (67.7%) on immunohistochemistry using a tissue microarray containing 33 NKTL samples. Notably, overexpression of survivin was observed in 97% of cases. Based on our findings, we propose a model of NKTL pathogenesis where deregulation of p53 together with activation of Myc and NF-kappa B, possibly driven by EBV LMP-1, results in the cumulative up-regulation of survivin. Down-regulation of survivin with Terameprocol (EM-1421, a survivin inhibitor) results in reduced cell viability and increased apoptosis in tumour cells, suggesting that targeting survivin may be a potential novel therapeutic strategy in NKTL. Copyright (C) 2011 Pathological Society of Great Britain and Ireland. Published by John Wiley & Sons, Ltd.
RUNX3 Inactivation in Colorectal Polyps Arising Through Different Pathways of Colonic Carcinogenesis
Resumo:
OBJECTIVES: We hypothesized that RUNX3 inactivation by promoter hypermethylation in colorectal polyps is an early molecular event in colorectal carcinogenesis.
METHODS: RUNX3 protein expression was analyzed immunohistochemically in 50 sporadic colorectal polyps comprising 19 hyperplastic polyps (HPs), 14 traditional serrated adenomas (TSAs), and 17 sporadic traditional adenomas (sTAs) as well as in 19 familial adenomatous polyposis (FAP) samples from 10 patients showing aberrant crypt foci (ACF) (n=91), small adenomas (SmAds) (n=40), and large adenomas (LAds) (n=13). In addition, we assessed the frequency of promoter hypermethylation of RUNX3 by methylation-specific PCR (MSP) in all the 50 sporadic polyps as well as 38 microdissected FAP polyps comprising ACF, SmAds, and LAds obtained from 7 FAP samples. A total of 12 normal colon samples were also included for RUNX3 MSP analysis.
RESULTS: Compared to normal colon (2 of 12, 16%) and sTAs (3 of 17, 18%), HPs (15 of 19, 79%) and TSAs (8 of 14, 57%) displayed significant inactivation of RUNX3 (P<0.05). In FAP, RUNX3 inactivation was more frequently seen in ACF (78 of 91, 86%), SmAds (25 of 40, 62%), and LAds (6 of 13, 46%) compared to normal mucosa (0 of 19, 0%) in the same samples (all P<0.05). Promoter hypermethylation of RUNX3 was significantly higher in colorectal polyps (64 of 87, 74%) compared to normal colon (2 of 12, 16%) (P=0.001). Serrated polyps such as HPs (17 of 19, 89%) and TSAs (12 of 14, 86%) were significantly more methylated than sTAs (7 of 17, 44%) (P=0.004). RUNX3 hypermethylation was observed in 28 of the total 38 (74%) FAP polyps. Overall, RUNX3 promoter methylation correlated with inactivation of RUNX3 expression in sporadic (27 of 36, 75%) (P=0.022) and FAP (21 of 28, 75%) (P=0.021) polyps.
CONCLUSIONS: Our data suggest that RUNX3 inactivation due to promoter hypermethylation in colorectal polyps represents an early event in colorectal cancer (CRC) progression. In addition, epigenetic RUNX3 inactivation is a frequent event in the serrated colonic polyps as well as in the ACF of FAP polyps.
Resumo:
For in vitro studies of airway pathophysiology, primary epithelial cells have many advantages over immortalised cell lines. Nasal epithelial cells are easier to obtain than bronchial epithelial cells and can be used as an alternative for in vitro studies. Our objective was to compare nasal and bronchial epithelial cells from subjects with COPD to establish if these cells respond similarly to pro-inflammatory stimuli. Cell cultures from paired nasal and bronchial brushings (21 subjects) were incubated with cigarette smoke extract (CSE) prior to stimulation with Pseudomonas aeruginosa lipopolysaccharide. IL-6 and IL-8 were measured by ELISA and Toll-like receptor 4 (TLR-4) message and expression by RT-PCR and FACS respectively. IL-8 release correlated significantly between the two cell types. IL-6 secretion was significantly less from bronchial compared to nasal epithelial cells and secreted concentrations did not correlate. A 4 h CSE incubation was immunosuppressive for both nasal and bronchial cells, however prolonged incubation for 24 h was pro-inflammatory solely for the nasal cells. CSE reduced TLR-4 expression in bronchial cells only after 24 h, and was without effect on mRNA expression. In subjects with COPD, nasal epithelial cells cannot substitute for in vitro bronchial epithelial cells in airway inflammation studies. © 2012 Comer et al.