967 resultados para Narrow-band interference filters


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Oversampled narrow-band single-loop and multistage resonator-based bandpass sigma-delta (Σ-Δ) modulators that can accommodate different passband center to sampling frequency ratios are reported. These tunable bandpass configurations are designed by analytically determining and subsequently verifying through detailed empirical simulations the required compensation hardware to deliver enhanced noise-shaping. It is demonstrated that comparatively superior in-band signal-to-noise ratios and dynamic ranges are attributed to the inclusion of appropriate digital feedforward and feedback compensators within these structures.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We design optimal band pass filters for electrons in semiconductor heterostructures, under a uniform applied electric field. The inner cells are chosen to provide a desired transmission window. The outer cells are then designed to transform purely incoming or outgoing waves into Bloch states of the inner cells. The transfer matrix is interpreted as a conformal mapping in the complex plane, which allows us to write constraints on the outer cell parameters, from which physically useful values can be obtained.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The principles of operation of an experimental prototype instrument known as J-SCAN are described along with the derivation of formulae for the rapid calculation of normalized impedances; the structure of the instrument; relevant probe design parameters; digital quantization errors; and approaches for the optimization of single frequency operation. An eddy current probe is used As the inductance element of a passive tuned-circuit which is repeatedly excited with short impulses. Each impulse excites an oscillation which is subject to decay dependent upon the values of the tuned-circuit components: resistance, inductance and capacitance. Changing conditions under the probe that affect the resistance and inductance of this circuit will thus be detected through changes in the transient response. These changes in transient response, oscillation frequency and rate of decay, are digitized, and then normalized values for probe resistance and inductance changes are calculated immediately in a micro processor. This approach coupled with a minimum analogue processing and maximum of digital processing has advantages compared with the conventional approaches to eddy current instruments. In particular there are: the absence of an out of balance condition and the flexibility and stability of digital data processing.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This invention relates to the manufacture of multi-layer interference filters for use with infra-red radiation, especially at wavelengths beyond 3.8 microns. A method of manufacturing a multi-layer interference filter comprising the steps of forming on a substrate successive layers of lead telluride and another material in alternation, under conditions in which sufficient oxygen is included in the lead telluride layers to reduce the apparent free charge carrier concentration therein, so that the resulting filter exhibits enhanced transparency to radiation of wavelengths greater than 3.8 microns and enhanced natural absorption to radiation of wavelength less than 3.8 microns.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper we present the results of a coherent narrow-band search for continuous gravitational-wave signals from the Crab and Vela pulsars conducted on Virgo VSR4 data. In order to take into account a possible small mismatch between the gravitational-wave frequency and two times the star rotation frequency, inferred from measurement of the electromagnetic pulse rate, a range of 0.02 Hz around two times the star rotational frequency has been searched for both the pulsars. No evidence for a signal has been found and 95% confidence level upper limits have been computed assuming both that polarization parameters are completely unknown and that they are known with some uncertainty, as derived from x-ray observations of the pulsar wind torii. For Vela the upper limits are comparable to the spin-down limit, computed assuming that all the observed spin-down is due to the emission of gravitational waves. For Crab the upper limits are about a factor of 2 below the spin-down limit, and represent a significant improvement with respect to past analysis. This is the first time the spin-down limit is significantly overcome in a narrow-band search.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The dissertation presented here deals with high-precision Penning trap mass spectrometry on short-lived radionuclides. Owed to the ability of revealing all nucleonic interactions, mass measurements far off the line of ß-stability are expected to bring new insight to the current knowledge of nuclear properties and serve to test the predictive power of mass models and formulas. In nuclear astrophysics, atomic masses are fundamental parameters for the understanding of the synthesis of nuclei in the stellar environments. This thesis presents ten mass values of radionuclides around A = 90 interspersed in the predicted rp-process pathway. Six of them have been experimentally determined for the first time. The measurements have been carried out at the Penning-trap mass spectrometer SHIPTRAP using the destructive time-of-fligh ion-cyclotron-resonance (TOF-ICR) detection technique. Given the limited performance of the TOF-ICR detection when trying to investigate heavy/superheavy species with small production cross sections (σ< 1 μb), a new detection system is found to be necessary. Thus, the second part of this thesis deals with the commissioning of a cryogenic double-Penning trap system for the application of a highly-sensitive, narrow-band Fourier-transform ion-cyclotron-resonance (FT-ICR) detection technique. With the non-destructive FT-ICR detection method a single singly-charged trapped ion will provide the required information to determine its mass. First off-line tests of a new detector system based on a channeltron with an attached conversion dynode, of a cryogenic pumping barrier, to guarantee ultra-high vacuum conditions during mass determination, and of the detection electronics for the required single-ion sensitivity are reported.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background This is the first ever evaluation of narrow band imaging (NBI), an innovative endoscopic imaging procedure, for the visualisation of pleural processes. Methods The pleural cavity was examined in 26 patients with pleural effusions using both white light and narrow band imaging during thoracoscopy under local anaesthesia. Results In the great majority of the patients narrow band imaging depicted the blood vessels more clearly than white light, but failed to reveal any differences in number, shape or size. Only in a single case with pleura thickened by chronic inflammation and metastatic spread of lung cancer did narrow band imaging show vessels that were not detectable under white light. Conclusion It is not yet possible to assess to what extent the evidence provided by NBI is superior to that achieved with white light. Further studies are required, particularly in the early stages of pleural processes.

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper gives a general overview of the challenges that arise in using narrow-band signals, such as GSM, for localisation based on the time properties of the signal. Specifically, synchronisation and retrieving of time information are addressed. We pursue two contributions, namely, analysis of achievable synchronisation precision and processing of narrowband signals that can enable localization down to a meter. Keywords-localization, narrow band signals, TOA, TDOA I.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Time-based localization techniques such as multilateration are favoured for positioning to wide-band signals. Applying the same techniques with narrow-band signals such as GSM is not so trivial. The process is challenged by the needs of synchronization accuracy and timestamp resolution both in the nanoseconds range. We propose approaches to deal with both challenges. On the one hand, we introduce a method to eliminate the negative effect of synchronization offset on time measurements. On the other hand, we propose timestamps with nanoseconds accuracy by using timing information from the signal processing chain. For a set of experiments, ranging from sub-urban to indoor environments, we show that our proposed approaches are able to improve the localization accuracy of TDOA approaches by several factors. We are even able to demonstrate errors as small as 10 meters for outdoor settings with narrow-band signals.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Time-based indoor localization has been investigated for several years but the accuracy of existing solutions is limited by several factors, e.g., imperfect synchronization, signal bandwidth and indoor environment. In this paper, we compare two time-based localization algorithms for narrow-band signals, i.e., multilateration and fingerprinting. First, we develop a new Linear Least Square (LLS) algorithm for Differential Time Difference Of Arrival (DTDOA). Second, fingerprinting is among the most successful approaches used for indoor localization and typically relies on the collection of measurements on signal strength over the area of interest. We propose an alternative by constructing fingerprints of fine-grained time information of the radio signal. We offer comprehensive analytical discussions on the feasibility of the approaches, which are backed up by evaluations in a software defined radio based IEEE 802.15.4 testbed. Our work contributes to research on localization with narrow-band signals. The results show that our proposed DTDOA-based LLS algorithm obviously improves the localization accuracy compared to traditional TDOA-based LLS algorithm but the accuracy is still limited because of the complex indoor environment. Furthermore, we show that time-based fingerprinting is a promising alternative to power-based fingerprinting.