970 resultados para Narrow Band Imaging


Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper we present the results of a coherent narrow-band search for continuous gravitational-wave signals from the Crab and Vela pulsars conducted on Virgo VSR4 data. In order to take into account a possible small mismatch between the gravitational-wave frequency and two times the star rotation frequency, inferred from measurement of the electromagnetic pulse rate, a range of 0.02 Hz around two times the star rotational frequency has been searched for both the pulsars. No evidence for a signal has been found and 95% confidence level upper limits have been computed assuming both that polarization parameters are completely unknown and that they are known with some uncertainty, as derived from x-ray observations of the pulsar wind torii. For Vela the upper limits are comparable to the spin-down limit, computed assuming that all the observed spin-down is due to the emission of gravitational waves. For Crab the upper limits are about a factor of 2 below the spin-down limit, and represent a significant improvement with respect to past analysis. This is the first time the spin-down limit is significantly overcome in a narrow-band search.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The dissertation presented here deals with high-precision Penning trap mass spectrometry on short-lived radionuclides. Owed to the ability of revealing all nucleonic interactions, mass measurements far off the line of ß-stability are expected to bring new insight to the current knowledge of nuclear properties and serve to test the predictive power of mass models and formulas. In nuclear astrophysics, atomic masses are fundamental parameters for the understanding of the synthesis of nuclei in the stellar environments. This thesis presents ten mass values of radionuclides around A = 90 interspersed in the predicted rp-process pathway. Six of them have been experimentally determined for the first time. The measurements have been carried out at the Penning-trap mass spectrometer SHIPTRAP using the destructive time-of-fligh ion-cyclotron-resonance (TOF-ICR) detection technique. Given the limited performance of the TOF-ICR detection when trying to investigate heavy/superheavy species with small production cross sections (σ< 1 μb), a new detection system is found to be necessary. Thus, the second part of this thesis deals with the commissioning of a cryogenic double-Penning trap system for the application of a highly-sensitive, narrow-band Fourier-transform ion-cyclotron-resonance (FT-ICR) detection technique. With the non-destructive FT-ICR detection method a single singly-charged trapped ion will provide the required information to determine its mass. First off-line tests of a new detector system based on a channeltron with an attached conversion dynode, of a cryogenic pumping barrier, to guarantee ultra-high vacuum conditions during mass determination, and of the detection electronics for the required single-ion sensitivity are reported.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper gives a general overview of the challenges that arise in using narrow-band signals, such as GSM, for localisation based on the time properties of the signal. Specifically, synchronisation and retrieving of time information are addressed. We pursue two contributions, namely, analysis of achievable synchronisation precision and processing of narrowband signals that can enable localization down to a meter. Keywords-localization, narrow band signals, TOA, TDOA I.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Time-based localization techniques such as multilateration are favoured for positioning to wide-band signals. Applying the same techniques with narrow-band signals such as GSM is not so trivial. The process is challenged by the needs of synchronization accuracy and timestamp resolution both in the nanoseconds range. We propose approaches to deal with both challenges. On the one hand, we introduce a method to eliminate the negative effect of synchronization offset on time measurements. On the other hand, we propose timestamps with nanoseconds accuracy by using timing information from the signal processing chain. For a set of experiments, ranging from sub-urban to indoor environments, we show that our proposed approaches are able to improve the localization accuracy of TDOA approaches by several factors. We are even able to demonstrate errors as small as 10 meters for outdoor settings with narrow-band signals.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Time-based indoor localization has been investigated for several years but the accuracy of existing solutions is limited by several factors, e.g., imperfect synchronization, signal bandwidth and indoor environment. In this paper, we compare two time-based localization algorithms for narrow-band signals, i.e., multilateration and fingerprinting. First, we develop a new Linear Least Square (LLS) algorithm for Differential Time Difference Of Arrival (DTDOA). Second, fingerprinting is among the most successful approaches used for indoor localization and typically relies on the collection of measurements on signal strength over the area of interest. We propose an alternative by constructing fingerprints of fine-grained time information of the radio signal. We offer comprehensive analytical discussions on the feasibility of the approaches, which are backed up by evaluations in a software defined radio based IEEE 802.15.4 testbed. Our work contributes to research on localization with narrow-band signals. The results show that our proposed DTDOA-based LLS algorithm obviously improves the localization accuracy compared to traditional TDOA-based LLS algorithm but the accuracy is still limited because of the complex indoor environment. Furthermore, we show that time-based fingerprinting is a promising alternative to power-based fingerprinting.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We design a Raman fibre laser with a short cavity providing narrow-band generation. The laser is based on a commercial single-mode fibre (980-HP) span of 12 m length. The laser generates up to 11 W of intracavity power. Even at high generation power, the laser spectrum is narrow (less than 200 pm) - several times narrower than for conventional Raman fibre lasers based on longer fibres. The intensity dynamics reveals indications of mode correlations. © 2014 Astro Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Narrow-band emission of spectral width down to ∼0.05 nm linewidth is achieved in the random distributed feedback fiber laser employing narrow-band fiber Bragg grating or fiber Fabry-Perot interferometer filters. The observed line-width is ∼10 times less than line-width of other demonstrated up to date random distributed feedback fiber lasers. The random DFB laser with Fabry-Perot interferometer filter provides simultaneously multi-wavelength and narrow-band (within each line) generation with possibility of further wavelength tuning. © 2013 Optical Society of America.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Narrow-band generation is achieved in random distributed feedback (RDFB) fiber laser by using narrow-band filters in the center of a distributed cavity. The resulting line-width of ∼0.1 nm is 10 times less than line-width in classical random distributed feedback fiber laser. Spectral properties can be optimized further. © 2012 OSA.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The wide adaptation of Internet Protocol (IP) as de facto protocol for most communication networks has established a need for developing IP capable data link layer protocol solutions for Machine to machine (M2M) and Internet of Things (IoT) networks. However, the wireless networks used for M2M and IoT applications usually lack the resources commonly associated with modern wireless communication networks. The existing IP capable data link layer solutions for wireless IoT networks provide the necessary overhead minimising and frame optimising features, but are often built to be compatible only with IPv6 and specific radio platforms. The objective of this thesis is to design IPv4 compatible data link layer for Netcontrol Oy's narrow band half-duplex packet data radio system. Based on extensive literature research, system modelling and solution concept testing, this thesis proposes the usage of tunslip protocol as the basis for the system data link layer protocol development. In addition to the functionality of tunslip, this thesis discusses the additional network, routing, compression, security and collision avoidance changes required to be made to the radio platform in order for it to be IP compatible while still being able to maintain the point-to-multipoint and multi-hop network characteristics. The data link layer design consists of the radio application, dynamic Maximum Transmission Unit (MTU) optimisation daemon and the tunslip interface. The proposed design uses tunslip for creating an IP capable data link protocol interface. The radio application receives data from tunslip and compresses the packets and uses the IP addressing information for radio network addressing and routing before forwarding the message to radio network. The dynamic MTU size optimisation daemon controls the tunslip interface maximum MTU size according to the link quality assessment calculated from the radio network diagnostic data received from the radio application. For determining the usability of tunslip as the basis for data link layer protocol, testing of the tunslip interface is conducted with both IEEE 802.15.4 radios and packet data radios. The test cases measure the radio network usability for User Datagram Protocol (UDP) based applications without applying any header or content compression. The test results for the packet data radios reveal that the typical success rate for packet reception through a single-hop link is above 99% with a round-trip-delay of 0.315s for 63B packets.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

ABSTRACT We present the first detailed spatiokinematical analysis and modelling of the planetary nebula Abell 41, which is known to contain the well-studied close-binary system MT Ser. This object represents an important test case in the study of the evolution of planetary nebulae with binary central stars as current evolutionary theories predict that the binary plane should be aligned perpendicular to the symmetry axis of the nebula. Deep narrow-band imaging in the light of [NII]6584Å, [OIII]5007 Å and [SII]6717+6731Å, obtained using ACAM on the William Herschel Telescope, has been used to investigate the ionization structure of Abell 41. Long-slit observations of the Ha and [NII]6584Å emission were obtained using the Manchester Echelle Spectrometer on the 2.1-m San Pedro Mártir Telescope. These spectra, combined with the narrow-band imagery, were used to develop a spatiokinematical model of [NII]6584Å emission from Abell 41. The best-fitting model reveals Abell 41 to have a waisted, bipolar structure with an expansion velocity of ~40 km s-1 at the waist. The symmetry axis of the model nebula is within 5° of perpendicular to the orbital plane of the central binary system. This provides strong evidence that the close-binary system, MT Ser, has directly affected the shaping of its nebula, Abell 41. Although the theoretical link between bipolar planetary nebulae and binary central stars is long established, this nebula is only the second to have this link, between nebular symmetry axis and binary plane, proved observationally.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We present Gemini-N GMOS and CFHT MOS spectroscopy of Wolf-Rayet candidates in the Local Group dwarf galaxy IC 10 that were previously identified by Massey et al. and Royer et al. From the present spectroscopic survey, the WC/WN ratio for IC 10 remains unusually high, given its low metallicity, although none of the WC9 stars suspected from narrow-band imaging are confirmed. Our spectroscopy confirms 9 newly discovered Wolf-Rayet candidates from Royer et al., whilst spectral types of 14 Wolf-Rayet stars previously observed by Massey & Armandroff are refined here. In total, there are 26 spectroscopically confirmed Wolf-Rayet stars in IC 10. All but one of the fourteen WC stars are WC4-6 stars, the exception being # 10 from Massey et al., a broad-lined, apparently single WC7 star. There are a total of eleven WN stars, which are predominantly early WN3-4 stars, but include a rare WN10 star, # 8 from Royer et al. # 5 from Massey et al. is newly identified as a transition WN/C star. Consequently, the WC/WN ratio for IC10 is 14/11similar to1.3, unusually high for a metal-poor galaxy. Re-evaluating recent photometric data of Massey & Holmes, we suggest that the true WC/WN ratio may not be as low as similar to0.3. Finally, we present ground-based finding charts for all confirmed WR stars, plus HST/WFPC2 charts for twelve cases.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

O carcinoma foi a principal causa de morte para cerca de 8,2 milhões de habitantes no ano de 2012 a nível mundial. Deste valor, estima-se que o carcinoma colo retal foi responsável por 694.000 mortes nesse mesmo ano. O tratamento eficaz deste carcinoma carece de uma deteção precoce de determinadas patologias associadas, nomeadamente, à presença de hemorragia ou pólipo na mucosa intestinal. Essa deteção precoce passa pela realização frequente de determinados exames clínicos invasivos, como a endoscopia e a colonoscopia, que poderão ser demasiado invasivos para o Homem para serem realizados regularmente. Assim surgiu a capsula endoscópica (CE) como método de diagnóstico pouco invasivo, confortável, seguro e com a funcionalidade de permitir a visualização de todo o trato gastrointestinal (TGI), uma vez que, com os métodos tradicionais de diagnóstico (endoscopia e colonoscopia) isso não acontece. Técnicas computacionais de processamento e análise de imagem automáticas, tais como filtros de suavização, remoção de ruído, deteção de contorno ou segmentação de zonas de interesse, podem ser utilizadas para facilitar a deteção destas patologias e homogeneizar a resposta entre diferentes clínicos, uma vez que, por cada exame de endoscopia por capsula são recolhidas cerca de 57 600 imagens. As imagens recolhidas a partir da CE passam por uma série de passos de processamento de imagem a m de clarificar a existência ou ausência de patologias no interior do TGI. Essa classificação pretende simplificar e auxiliar o clínico no diagnóstico precoce relativamente às patologias em causa, assim como reduzir o seu cansaço, aumentar a sua performance e aumentar a sua eficiência na análise de dados. Neste contexto e em parceria com a empresa INOVA+, esta tese está integrada no projeto PhotonicPill cofinanciado pelo QREN (Quadro de Referência Estratégico Nacional). Este projeto visa desenvolver um conjunto de módulos baseados em fotónica para incorporar numa CE, a m de possibilitar um diagnóstico mais preciso e atempado de diversas patologias, nomeadamente a presença de pólipos e hemorragias, assim como a possibilidade de terapêutica em locais do trato gastrointestinal de difícil acesso, como é o caso do intestino delgado. Um dos módulos baseados em fotónica assenta na tecnologia narrow band imaging (NBI). A contribuição desta tese no projeto prendeu-se no desenvolvimento de 3 métodos de deteção automática. O primeiro direcionado para a deteção de hemorragia, baseou-se na identificação dos valores mínimos e máximos dos canais de R,G,B para criar um valor de threshold duplo. De seguida, complementa-se o método através de operações morfológicas e operações locais. O segundo método de deteção automática é direcionado para a deteção de pólipo e baseou-se na aplicação da transformada de watershed juntamente com o cálculo de medidas associadas à forma típica de um pólipo. Por último, desenvolveu-se um método de deteção de vascularização na mucosa intestinal recorrendo essencialmente à deteção de valores máximos para cada canal do modelo RGB, definindo um valor de threshold máximo para cada um dos três canais. Uma vez testados os algoritmos e obtendo uma percentagem de especificidade e sensibilidade média superior a 70% em todos os métodos, desenvolveu-se um protótipo de uma interface gráfica para este sistema de apoio à decisão clínica que engloba os três parâmetros em análise: deteção de hemorragia, deteção de pólipo e deteção de vascularização. Esta interface fará toda a gestão do processo, ou seja, fara de forma automática a deteção e classificação das patologias a detetar, lançando uma mensagem de alerta ao clínico a informar se o paciente é ou não portador de alguma das anomalias em análise.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Emission line galaxies are the most easily detected and studied objects in the high redshift Universe. They are being used to trace the evolution of critical observables of the Universe such as Star Formation Rate densities, starburst properties and abundances. Most of the research is being done using [OII]3727 and UV lines, but Hα is still one the best tracers for Star Formation Rate and physical properties of current star-forming galaxies. As a complementary contribution to studies of galaxy evolution, our team has focused into a long-term project to study the population of Hα-selected star-forming galaxies of the Universe at different redshifts. In 1995 we first determined the local Hα luminosity function, and from it the Star Formation Rate density (SFRd) of the local Universe. We then, using narrow-band imaging in the optical, extended this measurement to z ≃ 0.24 and z ≃ 0.4. Working in the near-infrared, GTC will be a very powerful tool to study the evolution of the Hα emission-line galaxy populations at different redshifts. We will both quantify the SFRd evolution and characterize the star-forming galaxy populations by directly comparing the same observables at all redshifts up to z ≃ 2.5.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Through-wall imaging (TWI) may provide vital information on interior environment in cases when physically entering such environment would pose danger to the person involved. The concept of ultra wideband radar (UWB radar) is an emerging technology, which offers high spatial resolution, as opposed to narrow band radars. Thus, TWI applications using UWB radar have become a growing field of research with several applications in the civil and defense areas such as rescue and surveillance. For this study, a prototype system of UWB radar to TWI has been built. Analyses and result to several kinds of experiments have been presented, that is, detection and visualization of metallic targets behind wooden board wall and concrete blocks wall. The results are encouraging and show the advantages of using UWB radar for TWI. (C) 2011 Wiley Periodicals, Inc. Microwave Opt Technol Lett, 54:339-344, 2012; View this article online at wileyonlinelibrary.com. DOI 10.1002/mop.26543