951 resultados para Methods validation


Relevância:

40.00% 40.00%

Publicador:

Resumo:

In vitro release of bioidentical hormones in four different liposomal transdermal emulsions (containing testosterone, progesterone, estradiol, or estradiol and estriol) was assessed. For this purpose, novel high-performance liquid chromatography methods were developed and validated in an eco-friendly manner and used to determine the in vitro release of such products. The methods were suitable for our intended goal, and the emulsions employed were found to be effective as transporting candidates for the efficient release of hormones in the transdermal delivery of human sexual steroids.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The aim of this work was to develop and validate simple, accurate and precise spectroscopic methods (multicomponent, dual wavelength and simultaneous equations) for the simultaneous estimation and dissolution testing of ofloxacin and ornidazole tablet dosage forms. The medium of dissolution used was 900 ml of 0.01N HCl, using a paddle apparatus at a stirring rate of 50 rpm. The drug release was evaluated by developed and validated spectroscopic methods. Ofloxacin and ornidazole showed 293.4 and 319.6nm as λmax in 0.01N HCl. The methods were validated to meet requirements for a global regulatory filing. The validation included linearity, precision and accuracy. In addition, recovery studies and dissolution studies of three different tablets were compared and the results obtained show no significant difference among products.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In today's logistics environment, there is a tremendous need for accurate cost information and cost allocation. Companies searching for the proper solution often come across with activity-based costing (ABC) or one of its variations which utilizes cost drivers to allocate the costs of activities to cost objects. In order to allocate the costs accurately and reliably, the selection of appropriate cost drivers is essential in order to get the benefits of the costing system. The purpose of this study is to validate the transportation cost drivers of a Finnish wholesaler company and ultimately select the best possible driver alternatives for the company. The use of cost driver combinations as an alternative is also studied. The study is conducted as a part of case company's applied ABC-project using the statistical research as the main research method supported by a theoretical, literature based method. The main research tools featured in the study include simple and multiple regression analyses, which together with the literature and observations based practicality analysis forms the basis for the advanced methods. The results suggest that the most appropriate cost driver alternatives are the delivery drops and internal delivery weight. The possibility of using cost driver combinations is not suggested as their use doesn't provide substantially better results while increasing the measurement costs, complexity and load of use at the same time. The use of internal freight cost drivers is also questionable as the results indicate weakening trend in the cost allocation capabilities towards the end of the period. Therefore more research towards internal freight cost drivers should be conducted before taking them in use.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES

Relevância:

40.00% 40.00%

Publicador:

Resumo:

To validate a model for investigating the effects of analgesic drugs on mechanical, thermal and electrical stimulation testing. To investigate repeatability, sensitivity and specificity of nociceptive tests. Randomised experiment with 2 observers in 2 phases. Mechanical (M), thermal (TL) and electrical (E) stimuli were applied to the dorsal metacarpus (M-left and TL-right) and coronary band of the left thoracic limb (E) and a thoracic thermal stimulus (TT) was applied caudal to the withers in 8 horses (405 ± 43 kg). Stimuli intensities were increased until a clear avoidance response was detected without exceeding 20 N (M), 60°C (TL and TT) and 15 V (E). For each set of tests, 3 real stimuli and one sham stimulus were applied (32 per animal) using a blinded, randomised, crossover design repeated after 6 months. A distribution frequency and, for each stimulus, Chi-square and McNemar tests compared both the proportion of positive responses detected by 2 observers and the 2 study phases. The κ coefficients estimated interobserver agreement in determining endpoints. Sensitivity (384 tests) and specificity (128 tests) were evaluated for each nociceptive stimulus to assess the evaluators' accuracy in detecting real and sham stimuli. Nociceptive thresholds were 3.1 ± 2 N (M), 8.1 ± 3.8 V (E), 51.4 ± 5.5°C (TL) and 55.2 ± 5.3°C (TT). The level of agreement after all tests, M, E, TL and TT, was 90, 100, 84, 98 and 75%, respectively. Sensitivity was 89, 100, 89, 98 and 70% and specificity 92, 97, 88, 91 and 94%, respectively. The high interobserver agreement, sensitivity and specificity suggest that M, E and TL tests are valid for pain studies in horses and are suitable tools for investigating antinociceptive effects of analgesics in horses.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)