942 resultados para Meishan Section


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article examines some questions of statutory interpretation as they apply to section 130 of the Land Title Act 1994 (Qld)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Most studies examining determinants of rising rates of caesarean section have examined patterns in documented reasons for caesarean over time in a single location. Further insights could be gleaned from cross-cultural research that examines practice patterns in locations with disparate rates of caesarean section at a single time point. Methods We compared both rates of and main reason for pre-labour and intrapartum caesarean between England and Queensland, Australia, using data from retrospective cross-sectional surveys of women who had recently given birth in England (n = 5,250) and Queensland (n = 3,467). Results Women in Queensland were more likely to have had a caesarean birth (36.2%) than women in England (25.1% of births; OR = 1.44, 95% CI = 1.28-1.61), after adjustment for obstetric characteristics. Between-country differences were found for rates of pre-labour caesarean (21.2% vs. 12.2%) but not for intrapartum caesarean or assisted vaginal birth. Compared to women in England, women in Queensland with a history of caesarean were more likely to have had a pre-labour caesarean and more likely to have had an intrapartum caesarean, due only to a previous caesarean. Among women with no previous caesarean, Queensland women were more likely than women in England to have had a caesarean due to suspected disproportion and failure to progress in labour. Conclusions The higher rates of caesarean birth in Queensland are largely attributable to higher rates of caesarean for women with a previous caesarean, and for the main reason of having had a previous caesarean. Variation between countries may be accounted for by the absence of a single, comprehensive clinical guideline for caesarean section in Queensland. Keywords: Caesarean section; Childbirth; Pregnancy; Cross-cultural comparison; Vaginal birth after caesarean; Previous caesarean section; Patient-reported data; Quality improvement

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Here we report on an unconventional Ni-P alloy-catalyzed, high-throughput, highly reproducible chemical vapor deposition of ultralong carbon microcoils using acetylene precursor in the temperature range 700-750 °C. Scanning electron microscopy analysis reveals that the carbon microcoils have a unique double-helix structure and a uniform circular cross-section. It is shown that double-helix carbon microcoils have outstanding superelastic properties. The microcoils can be extended up to 10-20 times of their original coil length, and quickly recover the original state after releasing the force. A mechanical model of the carbon coils with a large spring index is developed to describe their extension and contraction. Given the initial coil parameters, this mechanical model can successfully account for the geometric nonlinearity of the spring constants for carbon micro- and nanocoils, and is found in a good agreement with the experimental data in the whole stretching process.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

SupaCee section is one of the cold-formed steel members which is increasingly used in the construction sector. It is characterized by unique ribbed web and curved lip elements, and is claimed to be more economical with extra strength than the traditional channel sections. SupaCee sections are widely used in Australia as floor joists, bearers, purlins and girts. Many experimental and numerical studies have been carried out to evaluate the behaviour and design of conventional channel beams subject to web crippling. To date, however, no investigation has been conducted into the web crippling behaviour and strength of SupaCee sections. Current cold-formed steel design equations do not include any design procedures for SupaCee sections. Hence experimental studies were conducted to assess the web crippling behaviour and strengths of SupaCee sections under ETF and ITF load cases. Thirty six web crippling tests were conducted and the capacity results were compared with the predictions from the AS/NZS 4600 and AISI design rules developed for conventional channel sections. Comparison of ultimate web crippling capacities from tests showed that AS/NZS 4600 and AISI design equations are unconservative for SupaCee sections under ETF load case, but are overly conservative for ITF load case. Hence new equations were proposed to determine the web crippling capacities of SupaCee sections based on the experimental results from this study. Suitable design rules were also developed within the direct strength method format. This paper presents the details of this experimental study of SupaCee sections subject to web crippling and the results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Surgical site infections following caesarean section are a serious and costly adverse event for Australian hospitals. In the United Kingdom, 9% of women are diagnosed with a surgical site infection following caesarean section either in hospital or post-discharge (Wloch et al 2012, Ward et al 2008). Additional staff time, pharmaceuticals and health supplies, and increased length of stay or readmission to hospital are often required (Henman et al 2012). Part of my PhD investigated the economics of preventing post-caesarean infection. This paper summarises a review of relevant infection prevention strategies. Administering antibiotic prophylaxis 15 to 60 minutes pre-incision, rather than post cordclamping, is probably the most important infection prevention strategy for caesarean section (Smaill and Gyte2010, Liu et al 2013, Dahlke et al 2013). However the timing of antibiotic administration is reportedly inconsistent in Australian hospitals. Clinicians may be taking advice from the influential, but out-dated RANZCOG and United States Centers for Disease Control and Prevention guidelines (Royal Australian and New Zealand College of Obstetricians and Gynaecologists 2011, Mangram et al 1999). A number of other important international clinical guidelines, including Australia's NHMRC guidelines, recommend universal prophylactic antibiotics pre-incision for caesarean section (National Health and Medical Research Council 2010, National Collaborating Centre for Women's and Children's Health 2008, Anderson et al 2008, National Collaborating Centre for Women's and Children's Health 2011, Bratzler et al 2013, American College of Obstetricians and Gynecologists 2011a, Antibiotic Expert Group 2010). We need to ensure women receive preincision antibiotic prophylaxis, particularly as nurses and midwives play a significant role in managing an infection that may result from sub-optimal practice. It is acknowledged more explicitly now that nurses and midwives can influence prescribing and administration of antibiotics through informal approaches (Edwards et al 2011). Methods such as surgical safety checklists are a more formal way for nurses and midwives to ensure that antibiotics are administered pre-incision (American College of Obstetricians and Gynecologists 2011 b). Nurses and midwives can also be directly responsible for other infection prevention strategies such as instructing women to not remove pubic hair in the month before the expected date of delivery and wound management education (Ng et al 2013). Potentially more costly but effective strategies include using a Chlorhexidine-gluconate (CHG) sponge preoperatively (in addition to the usual operating room skin preparation) and vaginal cleansing with a povidone-iodine solution (Riley et al 2012, Rauk 2010, Haas, Morgan, and Contreras 2013).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Women undergoing cesarean section are vulnerable to adverse effects associated with inadvertent perioperative hypothermia, but there has been a lack of synthesized evidence for temperature management in this population. This systematic review aimed to synthesize the best available evidence in relation to preventing hypothermia in mothers undergoing cesarean section surgery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Commonwealth legislation covering insurance contracts contains numerous provisions designed to control the operation and effect of terms in life and general insurance contracts. For example, the Life Insurance Act 1995 (Cth) contains provisions regulating the consequences attendant upon incorrect statements in proposals [1] and non-payment of premiums, [2] provides that an insurer may only exclude liability in the case of suicide if it has made express provision for such contingency in its policy, [3] and severely restricts the efficacy of conditions as to war risks. [4] The Insurance Contracts Act 1984 (Cth) is even more intrusive and has a major impact upon contractual provisions in the general insurance field. It is beyond the scope of this note to explore all of these provisions in any detail but examples of controls and constraints imposed upon the operation and effect of contractual provisions include the following. A party is precluded from relying upon a provision in a contract of insurance if such reliance would amount to a failure to act with the utmost good faith. [5] Similarly, a policy provision which requires differences or disputes arising out of the insurance to be submitted to arbitration is void, [6] unless the insurance is a genuine cover for excess of loss over and above another specified insurance. [7] Similarly clause such as conciliation clauses, [8] average clauses, [9] and unusual terms [10] are given qualified operation. [11] However the provision in the Insurance Contracts Act that has the greatest impact upon, and application to, a wide range of insurance clauses and claims is s 54. This section has already generated a significant volume of case law and is the focus of this note. In particular this note examines two recent cases. The first, Johnson v Triple C Furniture and Electrical Pty Ltd [2012] 2 Qd R 337, (hereafter the Triple C case), is a decision of the Queensland Court of Appeal; and the second, Matthew Maxwell v Highway Hauliers Pty Ltd [2013] WASCA 115, (hereafter the Highway Hauliers case), is a decision of the Court of Appeal in Western Australia. This latter decision is on appeal to the High Court of Australia. The note considers too the decision of the New South Wales Court of Appeal in Prepaid Services Pty Ltd v Atradius Credit Insurance NV [2013] NSWCA 252 (hereafter the Prepaid Services case).These cases serve to highlight the complex nature of s 54 and its application, as well as the difficulty in achieving a balance between an insurer and an insured's reasonable expectations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Galvanic corrosion is a common phenomenon in Carbon Fibre Reinforced Polymer (CFRP) strengthened steel structures in wet environments and submerged conditions, which reduces durability by weakening the bond between the CFRP and steel substrate. CFRP materials have already been proven to have superior resistance to corrosion and chemical attacks but the adhesive and steel are generally affected by long-term exposure to moisture, especially in conjunction with salts resulting from deicing of ocean spray. This paper presents the results of a research program to improve the durability of CFRP strengthened steel circular hollow section (CHS) members by treating the steel surface with an epoxy based adhesion promoter and inserting Glass Fibre Reinforced Polymer (GFRP) as a galvanic corrosion barrier against simulated sea water. It also presents the effects of accelerated corrosion on the bond of CFRP strengthened hollow steel members. The program consisted of four CFRP strengthened steel beams and one unstrengthened steel beam. Two strengthened beams were used as control while the other two beams were exposed to a highly corrosive environment to induce accelerated corrosion. The corrosion rate was considered 10% which represents a moderate level of loss in the cross-sectional area of the steel tube throughout its intended service life. The beams were then loaded to failure under four-point bending. The research findings indicate that the accelerated corrosion adversely affected the ultimate strength of the conditioned beams and the embedded glass fibre enhanced the bond durability.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper reports the details of an experimental study of cold-formed steel hollow section columns at ambient and elevated temperatures. In this study the global buckling behaviour of cold-formed Square Hollow Section (SHS) slender columns under axial compression was investigated at various uniform elevated temperatures up to 700℃. The results of these column tests are reported in this paper, which include the buckling/failure modes at elevated temperatures, and ultimate load versus temperature curves. Finite element models of tested columns were also developed and their behaviour and ultimate capacities at ambient and elevated temperatures were studied. Fire design rules given in European and American standards including the Direct Strength Method (DSM) based design rules were used to predict the ultimate capacities of tested columns at elevated temperatures. Elevated temperature mechanical properties and stress-strain models given in European steel design standards and past researches were used with design rules and finite element models to investigate their effects on SHS column capacities. Comparisons of column capacities from tests and finite element analyses with those predicted by current design rules were used to determine the accuracy of currently available column design rules in predicting the capacities of SHS columns at elevated temperatures and the need to use appropriate elevated temperature material stress-strain models. This paper presents the important findings derived from the comparisons of these column capacities.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fire safety plays a vital role in building design because appropriate level of fire safety is important to safeguard lives and property. Cold-formed steel channel sections along with fire-resistive plasterboards are used to construct light-gauge steel frame (LSF) floor systems to provide adequate fire resistance ratings (FRR). It is common practice to use lipped channel sections (LCS) as joists in LSF floor systems, and past research has only considered such systems. This research focuses on adopting improved joist sections such as hollow flange channel (HFC) sections to improve the structural performance and FRR of cold-formed LSF floor systems under standard fire conditions. The structural and thermal performances of LSF floor systems made of a welded HFC, LiteSteel Beams (LSB), with different plasterboard and insulation configurations, were investigated using four full-scale fire tests under standard fires. These fire tests showed that the new LSF floor system with LSB joists improved the FRR in comparison to that of conventional LCS joists. Fire tests have provided valuable structural and thermal performance data of tested floor systems that included time-temperature profiles and failure times, temperatures, and modes. This paper presents the details of the fire tests conducted in this study and their results along with some important findings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Instability of thin-walled open-section laminated composite beams is studied using the finite element method. A two-noded, 8 df per node thin-walled open-section laminated composite beam finite element has been used. The displacements of the element reference axis are expressed in terms of one-dimensional first order Hermite interpolation polynomials, and line member assumptions are invoked in formulation of the elastic stiffness matrix and geometric stiffness matrix. The nonlinear expressions for the strains occurring in thin-walled open-section beams, when subjected to axial, flexural and torsional loads, are incorporated in a general instability analysis. Several problems for which continuum solutions (exact/approximate) are possible have been solved in order to evaluate the performance of finite element. Next its applicability is demonstrated by predicting the buckling loads for the following problems of laminated composites: (i) two layer (45°/−45°) composite Z section cantilever beam and (ii) three layer (0°/45°/0°) composite Z section cantilever beam.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effect of a magnetic field on the flow and oxygenation of an incompressible Newtonian conducting fluid in channels with irregular boundaries has been investigated. The geometric parameter δ, which is a ratio of the mean half width of the channel d to the characteristic length λ along the channel over which the significant changes in the flow quantities occur, has been used for perturbing the governing equations. Closed form solutions of the various order equations are presented for the stream function. The equations for oxygen partial pressure remain nonlinear even after perturbation, therefore a numerical solution is presented. The expressions for shear stress at a wall and pressure distributions are derived. Here the separation in the flow occurs at a higher Reynolds number than the corresponding non-magnetic case. It is found that the magnetic field has an effect on local oxygen concentration but has a little effect on the saturation length.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A modified DLTS technique is proposed for the direct measurement of capture cross-section of MOS surface states. The nature of temperature and energy dependence σn is inferred from data analysis. Temperature dependence of σn is shown to be consistent with the observed DLTS line shapes.