992 resultados para Magnetic Levitation, Superconduzione Magnetica, Transrapid, Yamanashi, Guideway


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

"August 1994."

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Magnetic levitation bearings eliminate friction, wear and the need for lubrication and so have high speed capability and potential for vibration control. One noteworthy development in the realm of magnetic levitation is the self-bearing or bearingless motor - an electromagnetic machine that supports its own rotor by way of magnetic forces generated by windings on its stator. Accordingly, various winding schemes have been proposed to accomplish the task of force production. This thesis proposes a novel concept of winding based on a bridge connection for polyphase self-bearing rotating electrical machines with the following advantages: • the connection uses a single set of windings and thus power loss is relatively low when compared with self-bearing motors with conventional dual set of windings. • the motor and levitation controls are segregated such that only one motor inverter is required for the normal torque production and levitation forces are produced by using auxiliary power supplies of relatively low current and voltage rating. The usual way of controlling the motor is retained. • there are many variant winding schemes to meet special needs. • independent power supplies for levitation control offer redundancy for fault tolerance. This thesis dwells specifically on the conceptual design and implementation of the proposed single set of windings scheme. The new connection has been verified to exhibit characteristics of a self-bearing motor via coupled-field finite element analysis: results are crosschecked analytically. Power loss and other aspects such as cost, design implementation are compared to support the newly proposed connection as a potential alternative to present designs.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Hirota et al. [6] found that the magneto-Archimedes force could be used to levitate biological materials at different heights in pressurized oxygen, providing the possibility to separate them. However the magnetic levitation of mineral particles has not been widely explored. With this in mind some preliminary experiments were performed by levitating pure mineral materials in a paramagnetic solution manganese (II) chloride. Besides the report of levitation heights of various mineral particles in manganese (II) chloride solution, the lines obtained from the basic formula provided by previous researchers were compared with experimental data. The act of cryogenic paramagnetic fluid in the magneto-Archimedes levitation was also demonstrated. The obtained results are compared with the same particle levitation heights in manganese (II) chloride solution. © 2014 Elsevier B.V.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In the casting of reactive metals, such as titanium alloys, contamination can be prevented if there is no contact between the hot liquid metal and solid crucible. This can be achieved by containing the liquid metal by means of high frequency AC magnetic field. A water cooled current-carrying coil, surrounding the metal can then provide the required Lorentz forces, and at the same time the current induced in the metal can provide the heating required to melt it. This ‘attractive’ processing solution has however many problems, the most serious being that of the control and containment of the liquid metal envelope, which requires a balance of the gravity and induced inertia forces on the one side, and the containing Lorentz and surface tension forces on the other. To model this process requires a fully coupled dyna ic solution of the flow fields, magnetic field and heat transfer/melding process to account for. A simplified solution has been published previously providing quasi-static solutions only, by taking the irrotational ‘magnetic pressure’ term of the Lorentz force into account. The authors remedy this deficiency by modelling the full problem using CFD techniques. The salient features of these techniques are included in this paper, as space allows.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We present practical modelling techniques for electromagnetically agitated liquid metal flows involving dynamic change of the fluid volume and shape during melting and the free surface oscillation. Typically the electromagnetic field is strongly coupled to the free surface dynamics and the heat-mass transfer. Accurate pseudo-spectral code and the k-omega turbulence model modified for complex and transitional flows with free surfaces are used for these simulations. The considered examples include magnetic suspension melting, induction scull remelting (cold crucible), levitation and aluminium electrolysis cells. The process control and the energy savings issues are analysed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In high intensity and high gradient magnetic fields the volumetric force on diamagnetic material, such as water, leads to conditions very similar to microgravity in a terrestrial laboratory. In principle, this opens the possibility to determine material properties of liquid samples without wall contact, even for electrically non-conducting materials. In contrast, AC field levitation is used for conductors, but then terrestrial conditions lead to turbulent flow driven by Lorentz forces. DC field damping of the flow is feasible and indeed practiced to allow property measurements. However, the AC/DC field combination acts preferentially on certain oscillation modes and leads to a shift in the droplet oscillation spectrum.What is the cause? A nonlinear spectral numerical model is presented, to address these problems

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In high intensity and high gradient magnetic fields the volumetric force on diamagnetic material, such as water, leads to conditions very similar to microgravity in a terrestrial laboratory. In principle, this opens the possibility to determine material properties of liquid samples without wall contact, even for electrically non-conducting materials. In contrast, AC field levitation is used for conductors, but then terrestrial conditions lead to turbulent flow driven by Lorentz forces. DC field damping of the flow is feasible and indeed practiced to allow property measurements. However, the AC/DC field combination acts preferentially on certain oscillation modes and leads to a shift in the droplet oscillation spectrum.What is the cause? A nonlinear spectral numerical model is presented, to address these problems.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Electromagnetic levitation of liquid metal droplets can be used to measure the properties of highly reactive liquid materials. Two independent numerical models, the commercial COMSOL and the spectral-collocation based free surface code SPHINX, have been applied to solve the transient electromagnetic, fluid flow and thermodynamic equations, which describe the levitated liquid motion and heating processes. The SPHINX model incorporates free surface deformation to accurately model the oscillations that result from the interaction between the electromagnetic and gravity forces, temperature dependent surface tension, magnetically controlled turbulent momentum transport. The models are adapted to incorporate periodic laser heating at the top of the droplet, which is used to measure the thermal conductivity of the material. Novel effects in the levitated droplet of magnetically damped turbulence and nonlinear growth of velocities in high DC magnetic field are analysed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The intense AC magnetic field required to produce levitation in terrestrial conditions, along with the buoyancy and thermo-capillary forces, results in turbulent convective flow within the droplet. The use of a homogenous DC magnetic field allows the convective flow to be damped. However the turbulence properties are affected at the same time, leading to a possibility that the effective turbulent damping is considerably reduced. The MHD modified K-Omega turbulence model allows the investigation of the effect of magnetic field on the turbulence. The model incorporates free surface deformation, the temperature dependent surface tension, turbulent momentum transport, electromagnetic and gravity forces. The model is adapted to incorporate a periodic laser heating at the top of the droplet, which have been used to measure the thermal conductivity of the material by calculating the phase lag between the frequency of the laser heating and the temperature response at the bottom. The numerical simulations show that with the gradual increase of the DC field the fluid flow within the droplet is initially increasing in intensity. Only after a certain threshold magnitude of the field the flow intensity starts to decrease. In order to achieve the flow conditions close to the ‘laminar’ a D.C. magnetic field >4 Tesla is required to measure the thermal conductivity accurately. The reduction in the AC field driven flow in the main body of the drop leads to a noticeable thermo-capillary convection at the edge of the droplet. The uniform vertical DC magnetic field does not stop a translational oscillation of the droplet along the field, which is caused by the variation in total levitation force due to the time-dependent surface deformation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introducción: El uso de la estimulación cerebral no invasiva en procesos de rehabilitación es de gran interés, por cuanto con mediación tecnológica se generan nuevas posibilidades de recuperación motora, a partir de la activación de la corteza cerebral. El objetivo del estudio es establecer la evidencia del uso terapéutico de la EMT, relacionado con el desempeño motor de pacientes con enfermedades del sistema nervioso central. Metodología: Se realizó una revisión sistemática de la literatura. Se incluyeron 10 estudios en el análisis cualitativo que incluyó la evaluación de calidad con la escala de Jadad y del riesgo de sesgo con la herramienta Cochrane. Fueron excluidos 1613 estudios. Se aplicó el protocolo del estudio para la extracción, revisión y validez de los estudios incluidos. Resultados: La evidencia disponible muestra resultados positivos del uso terapéutico de la EMT en el desempeño motor en aspectos como la aceleración, la fuerza de pinza y de agarre, la estabilidad y la fuerza muscular, así como una mejor velocidad de la marcha y una disminución en la frecuencia y severidad de los espasmos. Discusión: La EMT puede constituir una estrategia terapéutica para mejorar el desempeño motor en pacientes con ECV, Lesión Medular y enfermedad de Parkinson, que requiere más investigación por la heterogeneidad de los diseños y medidas de descenlace utilizados, así como por la alta variabilidad interindividual que hace complejo estandarizar los protocolos de su uso terapéutico.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We report on the measurements of both vertical and lateral levitation forces between a permanent magnet NdFeB and a polycrystalline YBa4Cu6O7-delta superconductor. The analysis of the obtained results revealed an interesting correlation between the behavior of the forces in the field-cooled and zero-field-cooled regimes, resembling the structure of the so-called susceptibility spectrum chi ''(chi'). Such force-force diagrams can be useful for identifying flux distribution structure inside a superconducting material. (C) 2012 American Institute of Physics. [http://dx.doi.org/10.1063/1.4743006]

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aim of the present study was to evaluate the accuracy of transrectal ultrasound biopsy (TRUS-biopsy) directed to regions with abnormal MRI and/or MRSI (magnetic resonance spectroscopic imaging ) for both the transition (TZ) and the peripheral (PZ) zones in patients who presented with persistent suspect for prostate cancer and with prior negative biopsy. We also evaluated relationship between MRSI results and histopathological findings of biopsy. 54 patients with the aforementioned characteristics underwent MRI/MRSI at least 6 months after prior negative biopsy; interval between MRI/3D-MRSI and the further TRUS-biopsy was less than 3 months. The prostate was divided in 12 regions both for imaging interpretation and biopsy. Moreover one to three cores more were taken from each region with abnormal MRI and/or 3D-MRSI. Twenty-two out of 54 patients presented cancer at MRI/MRSI-directed-TRUS-biopsy. On a patient basis the highest accuracy was obtained by assigning malignancy on a positive finding with MRSI and MRI even though it was not significantly greater than that obtained using MRI alone (area under the ROC curve, AUC: 0.723 vs. 0.676). On a region (n=648) basis the best accuracy was also obtained by considering positive both MRSI and MRI for PZ (0.768) and TZ (0.822). Twenty-eight per cent of cores with prostatitis were false positive findings on MRSI, whereas only 2.7% of benign prostatic hyperplasia was false positive. In conclusion the accuracy of MRI/MRSI-directed biopsies in localization of prostate cancer is good in patient and region analyses. The combination of both MRI and MRSI results makes TRUS-biopsy more accurate particularly in the TZ (0.822) for patients with prior negative biopsies. Histopathological analysis showed that the main limitation of MRSI is the percentage of false positive findings due to prostatitis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Cerebellar malformation are increasingly diagnosed in utero. To assess the effectiveness of ultrasound and fetal magnetic resonance in the antenatal prediction of long term neurodevelopmental delay. STUDY DESIGN: We collected 105 cases of cerebellum malformation in the period 2000-2010 in Bologna and Bari University. Classification included cystic anomalies of posterior fossa and cerebellar hypoplasia. RESULTS: The greater group included Blake’s pouch cysts and mega cisterna magna cases (58/105). These cases seemed to have a good prognosis with a good outcome both in association with other anomalies and isolated. In cases of Dandy Walker malformation, vermis hypoplasia and cerebellum hypoplasia there were few survivors, so it was so difficult to outline some conclusion for child outcome. Despite great neuroimaging advances, in our study, ultrasound and MR reached a similar sensitivity (62-63%) for the diagnosis of posterior fossa anomalies, but the number of MR was lower compared with ultrasonography. CONCLUSION: Ultrasonography remains the screening method of choice for evaluation of cerebellum anatomy but probably MR imaging can improve some details expecially in the third trimester. Despite the data on Dandy Walker, vermis hypoplasia and cerebellum hypoplasia were conflicting and uncertain, for Blake and mega cisterna magna we can considered a rather good outcome.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Scopo del nostro studio è quello di valutare i disturbi cognitivi in relazione al tasso di microembolia cerebrale in due gruppi di pazienti trattati per lesione carotidea asintomatica con endoarterectomia (CEA) o stenting (CAS). Comparando le due metodiche mediante l’utilizzo di risonanza magnetica in diffusione (DW-MRI), neuromarkers (NSE e S100β) e test neuropsicometrici. MATERIALE E METODI: 60 pazienti sono stati sottoposti a rivascolarizzazione carotidea (CEA n=32 e CAS n=28). Sono stati tutti valutati con DW-MRI e Mini-Mental State Examination (MMSE) test nel preoperatorio, a 24 ore, a 6 ed a 12 mesi dall’intervento. In tutti sono stati dosati i livelli sierici di NSE e S100β mediante 5 prelievi seriati nel tempo, quello basale nel preoperatorio, l’ultimo a 24 ore. L’ananlisi statistica è stata effettuata con test t di Student per confronti multipli per valori continui e con test χ2 quadro e Fisher per le variabili categoriche. Significatività P <0,05. RISULTATI: Non vi è stato alcun decesso. Un paziente del gruppo CAS ha presentato un ictus ischemico. In 6 pazienti CAS ed in 1 paziente CEA si sono osservate nuove lesioni subcliniche alla RMN-DWI post-operatoria (21,4% vs 3% p=0,03). Nel gruppo CAS le nuove lesioni presenti alla RMN sono risultate significativamente associate ad un declino del punteggio del MMSE (p=0,001). L’analisi dei livelli di NSE e S100β ha mostrato un significativo aumento a 24 ore nei pazienti CAS (P = .02). A 12 mesi i pazienti che avevano presentato nuove lesioni ischemiche nel post-operatorio hanno mostrato minor punteggio al MMSE, non statisticamente significativo. CONCLUSIONI: I neuromarkers in combinazione con MMSE e RMN-DWI possono essere utilizzati nella valutazione del declino cognitivo correlato a lesioni silenti nell’immediato postoperatorio di rivascolarizzazione carotidea. Quest’ultime dovrebbero essere valutate quindi non solo rispetto al tasso di mortalità e ictus, ma anche rispetto al tasso di microembolia.