982 resultados para MIMIC computer
Resumo:
Sleeper is an 18'00" musical work for live performer and laptop computer which exists as both a live performance work and a recorded work for audio CD. The work has been presented at a range of international performance events and survey exhibitions. These include the 2003 International Computer Music Conference (Singapore) where it was selected for CD publication, Variable Resistance (San Francisco Museum of Modern Art, USA), and i.audio, a survey of experimental sound at the Performance Space, Sydney. The source sound materials are drawn from field recordings made in acoustically resonant spaces in the Australian urban environment, amplified and acoustic instruments, radio signals, and sound synthesis procedures. The processing techniques blur the boundaries between, and exploit, the perceptual ambiguities of de-contextualised and processed sound. The work thus challenges the arbitrary distinctions between sound, noise and music and attempts to reveal the inherent musicality in so-called non-musical materials via digitally re-processed location audio. Thematically the work investigates Paul Virilio’s theory that technology ‘collapses space’ via the relationship of technology to speed. Technically this is explored through the design of a music composition process that draws upon spatially and temporally dispersed sound materials treated using digital audio processing technologies. One of the contributions to knowledge in this work is a demonstration of how disparate materials may be employed within a compositional process to produce music through the establishment of musically meaningful morphological, spectral and pitch relationships. This is achieved through the design of novel digital audio processing networks and a software performance interface. The work explores, tests and extends the music perception theories of ‘reduced listening’ (Schaeffer, 1967) and ‘surrogacy’ (Smalley, 1997), by demonstrating how, through specific audio processing techniques, sounds may shifted away from ‘causal’ listening contexts towards abstract aesthetic listening contexts. In doing so, it demonstrates how various time and frequency domain processing techniques may be used to achieve this shift.
Resumo:
Aim: To investigate workplace cultures in the acquisition of computer usage skills by mature age workers. Methods: Data were gathered through focus groups conducted at job network centres in the Greater Brisbane metropolitan region. Participants who took part were a mixture of workers and job-seekers. Results: The results suggest that mature age workers can be exposed to inappropriate computer training practices and age-insensitive attitudes towards those with low base computer skills. Conclusions: There is a need for managers to be observant of ageist attitudes in the work place and to develop age-sensitive strategies to help mature age workers learn computer usage skills. Mature age workers also need to develop skills in ways which are practical and meaningful to their work.
Resumo:
Scoliosis is a spinal deformity, involving a side-to-side curvature of the spine in the coronal plane as well as a rotation of the spinal column in the transverse plane. The coronal curvature is measured using a Cobb angle. If the deformity is severe, treatment for scoliosis may require surgical intervention whereby a rod is attached to the spinal column to correct the abnormal curvature. In order to provide surgeons with an improved ability to predict the likely outcomes following surgery, techniques to create patient-specific finite element models (FEM) of scoliosis patients treated at the Mater Children’s Hospital (MCH) in Brisbane are being developed and validated. This paper presents a comparison of the simulated and clinical data for a scoliosis patient treated at MCH.
Resumo:
Discrete event-driven simulations of digital communication networks have been used widely. However, it is difficult to use a network simulator to simulate a hybrid system in which some objects are not discrete event-driven but are continuous time-driven. A networked control system (NCS) is such an application, in which physical process dynamics are continuous by nature. We have designed and implemented a hybrid simulation environment which effectively integrates models of continuous-time plant processes and discrete-event communication networks by extending the open source network simulator NS-2. To do this a synchronisation mechanism was developed to connect a continuous plant simulation with a discrete network simulation. Furthermore, for evaluating co-design approaches in an NCS environment, a piggybacking method was adopted to allow the control period to be adjusted during simulations. The effectiveness of the technique is demonstrated through case studies which simulate a networked control scenario in which the communication and control system properties are defined explicitly.
Resumo:
Despite the size and growth of the computer and video gaming industry – as well as the increasing use of the medium for the placement of advertising and product placement – researchers have neglected this area. By drawing on existing literature and research in similar and related areas of film product placement, sponsorship and interactivity, the authors present a conceptual overview and identify areas for research.
Resumo:
Computers not only increase the speed and efficiency of our mental efforts, but in the process they also alter the problem-solving tasks we are faced with and, in so doing, they alter the cognitive processes we use to solve problems. Computers are fundamentally changing our forms of thinking (Colc & Griffin, 1980). Therefore, the computer should be seen as not only having the potential to amplify human mental capabilities, but also of providing a catalyst for intellectual development.
Resumo:
Computer aided joint replacement surgery has become very popular during recent years and is being done in increasing numbers all over the world. The accuracy of the system depends to a major extent, on accurate registration and immobility of the tracker attachment devices to the bone. This study was designed to asses the forces needed to displace the tracker attachment devices in the bone simulators. Bone simulators were used to maintain the uniformity of the bone structure during the study. The fixation devices tested were 3mm diameter self drilling, self tapping threaded pin, 4mm diameter self tapping cortical threaded pin, 5mm diameter self tapping cancellous threaded pin and a triplanar fixation device ‘ortholock’ used with three 3mm pins. All the devices were tested for pull out, translational and rotational forces in unicortical and bicortical fixation modes. Also tested was the normal bang strength and forces generated by leaning on the devices. The forces required to produce translation increased with the increasing diameter of the pins. These were 105N, 185N, and 225N for the unicortical fixations and 130N, 200N, 225N for the bicortical fixations for 3mm, 4mm and 5mm diameter pins respectively. The forces required to pull out the pins were 1475N, 1650N, 2050N for the unicortical, 1020N, 3044N and 3042N for the bicortical fixated 3mm, 4mm and 5mm diameter pins. The ortholock translational and pull out strength was tested to 900N and 920N respectively and still it did not fail. Rotatory forces required to displace the tracker on pins was to the magnitude of 30N before failure. The ortholock device had rotational forces applied up to 135N and still did not fail. The manual leaning forces and the sudden bang forces generated were of the magnitude of 210N and 150N respectively. The strength of the fixation pins increases with increasing diameter from three to five mm for the translational forces. There is no significant difference in pull out forces of four mm and five mm diameter pins though it is more that the three mm diameter pins. This is because of the failure of material at that stage rather than the fixation device. The rotatory forces required to displace the tracker are very small and much less that that can be produced by the surgeon or assistants in single pins. Although the ortholock device was tested to 135N in rotation without failing, one has to be very careful not to put any forces during the operation on the tracker devices to ensure the accuracy of the procedure.
Resumo:
Vertebrplasty involved injecting cement into a fractured vertebra to provide stabilisation. There is clinical evidence to suggest however that vertebroplasty may be assocated with a higher risk of adjacent vertebral fracture; which may be due to the change in material properties of the post-procedure vertebra modifying the transmission of mechanical stresses to adjacent vertebrae.
Resumo:
The current understanding of students’ group metacognition is limited. The research on metacognition has focused mainly on the individual student. The aim of this study was to address the void by developing a conceptual model to inform the use of scaffolds to facilitate group metacognition during mathematical problem solving in computer supported collaborative learning (CSCL) environments. An initial conceptual framework based on the literature from metacognition, cooperative learning, cooperative group metacognition, and computer supported collaborative learning was used to inform the study. In order to achieve the study aim, a design research methodology incorporating two cycles was used. The first cycle focused on the within-group metacognition for sixteen groups of primary school students working together around the computer; the second cycle included between-group metacognition for six groups of primary school students working together on the Knowledge Forum® CSCL environment. The study found that providing groups with group metacognitive scaffolds resulted in groups planning, monitoring, and evaluating the task and team aspects of their group work. The metacognitive scaffolds allowed students to focus on how their group was completing the problem-solving task and working together as a team. From these findings, a revised conceptual model to inform the use of scaffolds to facilitate group metacognition during mathematical problem solving in computer supported collaborative learning (CSCL) environments was generated.
Resumo:
Computer tomography has been used to image and reconstruct in 3-D an Egyptian mummy from the collection of the British Museum. This study of Tjentmutengebtiu, a priestess from the 22nd dynasty (945-715 BC) revealed invaluable information of a scientific, Egyptological and palaeopathological nature without mutilation and destruction of the painted cartonnage case or linen wrappings. Precise details on the removal of the brain through the nasal cavity and the viscera from the abdominal cavity were obtained. The nature and composition of the false eyes were investigated. The detailed analysis of the teeth provided a much closer approximation of age at death. The identification of materials used for the various amulets including that of the figures placed in the viscera was graphically demonstrated using this technique.
Resumo:
Scoliosis is a three-dimensional spinal deformity which requires surgical correction in progressive cases. In order to optimize correction and avoid complications following scoliosis surgery, patient-specific finite element models (FEM) are being developed and validated by our group. In this paper, the modeling methodology is described and two clinically relevant load cases are simulated for a single patient. Firstly, a pre-operative patient flexibility assessment, the fulcrum bending radiograph, is simulated to assess the model's ability to represent spine flexibility. Secondly, intra-operative forces during single rod anterior correction are simulated. Clinically, the patient had an initial Cobb angle of 44 degrees, which reduced to 26 degrees during fulcrum bending. Surgically, the coronal deformity corrected to 14 degrees. The simulated initial Cobb angle was 40 degrees, which reduced to 23 degrees following the fulcrum bending load case. The simulated surgical procedure corrected the coronal deformity to 14 degrees. The computed results for the patient-specific FEM are within the accepted clinical Cobb measuring error of 5 degrees, suggested that this modeling methodology is capable of capturing the biomechanical behaviour of a scoliotic human spine during anterior corrective surgery.