1000 resultados para Método de adição padrão


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A-Nperp, Pg-Nperp e mandibular plane). Thirty patients (male or female), with age varying from 19 to 48 years old were analyzed. All patients were diagnosted with mandibular retrognathism and submitted to bilateral sagital mandibular advancement. All tracings were performed in lateral cephalometric radiographs obtained one week before surgery. The intraclass correlation coefficient analysis (ICC), the t test adjusted for Tukey-Kramer test and Schuirmann test were applied. The results showed that the manual tracings and Nemotec® tracing had excellent reliabilities for all measures (ICC > 0.98). The Dolphin Imaging® showed low reliability in anterior facial height (value of ICC = 0.70), Co-A (value of ICC = 0.47) and Co-Gn (ICC value = 0.49). In A-Nperp, Pg-Nperp, Mandibular plan, SNA and SNB there were no differences between the 3 tracings (p > 0.05), for the anterior facial height measures differences were found between the Dolphin Imaging® and Nemotec® tracings, but no differences were observed as compared to the manual tracing (p > 0.05), in Co-A and Co-Gn measures t Dolphin Imaging® presented a significantly lower mean than the other methods (p > 0.05). The manual tracings were equivalent in 6 of 8 measures (A-Nperp, Pg-Nperp, md Plan, SNA, SNB and Co-A), there was no equivalence between the methods in the anterior facial height and Co-Gn measures (p < 0.01). The Dolphin Imaging® method was not equivalent in any of the 8 measures. It was concluded that in the manual tracing only the Co- Gn, Pg-Nperp and SNB measures confirmed the diagnosis of mandibular retrognathism, and the Nemotec® software showed better results than the Dolphin Imaging® software.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

To determinate the multielemental concentrations in biological samples using the technique of total reflection X-ray fluorescence (TRFX) is essential the use of standard samples. The aim of this study is the determination of the sensitivities of the relevant elements in standard samples (Multi Element atomic spectroscopy standard solution in HNO3 I) prepared in three solutions with different and known concentrations. Based on the sensitivities of the elements contained in the multilelementar standard sample, it can estimate the sensitivity for an element found in the biological sample and consequently it is possible to determinate the concentration, even though the standard does not contain this element. The measurement of fluorescence was performed at the Brazilian Synchrotron Light Laboratory (LNLS) in Campinas

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Dissertação para obtenção do grau de Mestre no Instituto Superior de Ciências da Saúde Egas Moniz

Relevância:

40.00% 40.00%

Publicador:

Resumo:

VARELA, M. L. et al. Influência da adição de resíduo de caulim nas propriedades tecnológicas de uma massa padrão de porcelanato produzido em escala industrial. Cerâmica, v.55, n.334 p.209-215. 2009.ISSN 0366-6913.Disponível em: . Acesso em: 06 out. 2010.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

VARELA, M. L. et al. Influência da adição de resíduo de caulim nas propriedades tecnológicas de uma massa padrão de porcelanato produzido em escala industrial. Cerâmica, v.55, n.334 p.209-215. 2009.ISSN 0366-6913.Disponível em: . Acesso em: 06 out. 2010.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Este trabalho propõe o desenvolvimento de métodos de preparo de amostra empregando a microextração líquido-líquido dispersiva (DLLME) para a extração e pré- concentração de Fe e Cu em vinho, seguido da determinação espectrofotométrica na região do ultravioleta-visível (UV-Vis). Nas extrações por DLLME, a complexação de Fe e Cu foi feita com pirrolidina ditiocarbamato de amônio (APDC) e dietilditiocarbamato de sódio (DDTC), respectivamente. Para a DLLME, foi usada uma mistura apropriada de pequenos volumes de dois solventes, um extrator e outro dispersor, a qual foi rapidamente injetada na amostra aquosa, ocorrendo à formação de uma dispersão e a extração praticamente instantânea dos analitos. Na otimização da DLLME para extração de Fe foram avaliados alguns parâmetros como, tipo de solvente extrator (C2Cl4, 80 µL) e dispersor (acetonitrila, 1300 µL) e seus volumes, pH (3,0), concentração do APDC (1%, m/v), adição de NaCl (0,02 mol L -1 ) e tempo de extração. Para extração de Cu foi aplicado um planejamento fatorial completo 25 para avaliar a influência de cinco variáveis independentes: volume dos solventes dispersor (acetonitrila, 1600 µL) e extrator (CCl4, 60 µL), concentração de DDTC (2%, m/v), pH (3,0) e concentração de NaCl. Após a otimização das condições para Fe, a curva de calibração com adição de analito foi linear entre 0,2 e 2,5 mg L-1 para vinho branco (R2 = 0,9985) e para vinho tinto (R2 = 0,9988). Para Cu, a curva de calibração com adição de analito foi linear entre 0,05 e 1,0 mg L-1 para vinho branco (R2 = 0,9995) e para vinho tinto (R2 = 0,9986). Os limites de quantificação foram de 0,75 e 0,37 mg L-1 para Fe e Cu, respectivamente. A exatidão foi avaliada utilizando ensaio de recuperação, as quais variaram entre 96% e 112%, com desvio padrão relativo inferior a 8%. Os métodos foram aplicados para 5 amostras de vinho branco e 5 amostras de vinho tinto, obtendo-se concentrações entre 1,3 e 5,3 e entre 2,5 e 4,4 mg L-1 para Fe e entre 0,4 e 1,5 e entre 0,9 e 2,5 mg L-1 para Cu, respectivamente. Os métodos desenvolvidos para a extração e pré-concentração de Fe e Cu em vinhos por DLLME e quantificação por UV-Vis mostraram-se adequados, em termos de linearidade, exatidão e precisão.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The northeastern region of Brazil has a large number of wells producing oil using a method of secondary recovery steam injection, since the oil produced in this region is essentially viscous. This recovery method puts the cement / coating on thermal cycling, due to the difference in coefficient of thermal expansion between cement and metal coating causes the appearance of cracks at this interface, allowing the passage of the annular fluid, which is associated with serious risk socioeconomic and environmental. In view of these cracks, a correction operation is required, resulting in more costs and temporary halt of production of the well. Alternatively, the oil industry has developed technology for adding new materials in cement pastes, oil well, providing high ductility and low density in order to withstand the thermo-mechanical loads generated by the injection of water vapor. In this context, vermiculite, a clay mineral found in abundance in Brazil has been applied in its expanded form in the construction industry for the manufacture of lightweight concrete with excellent insulation and noise due to its high melting point and the presence of air in their layers lamellar. Therefore, the vermiculite is used for the purpose of providing low-density cement paste and withstand high temperatures caused by steam injection. Thus, the present study compared the default folder containing cement and water with the folders with 6%, 8% and 10% vermiculite micron conducting tests of free water, rheology and compressive strength where it obtained the concentration of 8 % with the best results. Subsequently, the selected concentration, was compared with the results recommended by the API standard tests of filtered and stability. And finally, analyzed the results from tests of specific gravity and time of thickening. Before the study we were able to make a folder with a low density that can be used in cementing oil well in order to withstand the thermo-mechanical loads generated by steam injection

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A supressividade de solos e influenciada pela atividade microbiana, porém sua avaliação muitas vezes apresenta problemas. O método de hidrolise de FDA avalia a atividade celular nas amostras de solo, visto que a hidrolise e realizada por diversas enzimas. Amostras de 5g de solo são colocadas em frascos de Erlenmeyer (250 ml), juntamente com 20 ml de tampão fosfato de potássio (60 mM; pH 7,6). A reação de hidrolise de FDA e iniciada adicionando-se 0,2ml de solução estoque de FDA(2mg FDA/ml acetona). As amostras são incubadas por 20 min. em agitador (200 rpm) a 25o C. A reação é interrompida através da adição de 20 ml de acetona por frasco. A seguir procede-se a filtragem (Whatman n.1), coletando-se o filtrado em tubos de cultivo acondicionados em recipiente com gelo. Em espectrofotometro, determina-se a absorbancia (490nm) do filtrado. A concentração de FDA hidrolisado e obtida através de uma curva padrão feita conforme a metodologia descrita, porem adicionando-se conhecidas quantidades de FDA hidrolisado (60 min. em agua fervendo) as amostras. Altas correlações foram obtidas entre a taxa de hidrólise de FDA, de solos submetidos a diferentes cultivos (mata, pastagem, cana-de-açúcar e culturas anuais), e a supressividade a Rhizoctonia solani.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Brazilian regulations prohibit the addition of cocoa butter replacements to chocolate, in total or partial substitution. The objective of the present work was to check the quality standards of four of coating bitter Brasilian chocolate bars and five of coating milk chocolate bars, commercialized in Campinas. In order to check the possible addition of substitutes, the triacylglycerol composition was determined, and the results were analysed by Padley & Timms mathematical method. The triacylglycerol composition of each sample was determined by high temperature gas chromatography (HTGC). The presence of cocoa butter replacements was not detected in the brands of coating chocolate.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Atualmente, o aproveitamento de resíduos na construção civil tem sido estimulado, uma vez que esse setor apresenta-se como um dos maiores consumidores de materiais naturais em seus processos e produtos. As cinzas ocupam lugar de destaque entre os resíduos agroindustriais por resultarem de processos de geração de energia. Grande parte dessas cinzas possui atividade pozolânica, podendo ser utilizada como substituto parcial do cimento Portland, resultando numa economia significativa de energia e custo. Este trabalho faz parte de uma pesquisa mais ampla, a qual busca avaliar a viabilidade técnica da cinza da casca da castanha de caju (CCCC) como adição mineral em matrizes de cimento Portland, como também, propor uma metodologia de análise de cinzas agroindustriais. Aplicou-se a técnica de difratometria de raios X para avaliar a reatividade do hidróxido de cálcio pela cinza da casca da castanha de caju em pastas, empregaram-se teores de substituição entre 2,5 e 30,0% e os difratogramas das pastas foram comparados com os das pastas confeccionadas com sílica ativa, executados sobre as mesmas condições de ensaio. Os resultados apontam para a ausência de reatividade pozolânica da CCCC com o cimento Portland.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Solid-phase microextraction, using on-line bis(trimethylsilyl)trifluoroacetamide derivatisation, gas chromatography, and mass spectrometry, was evaluated in the quantification of 3-chloro-4-(dichloromethyl)-5-hydroxy-2(5H)-furanone (MX) in water samples. Fibres encompassing a wide range of polarities were used with headspace and direct immersion sampling. For the immersion procedure, various parameters affecting MX extraction, including pH, salinity, temperature, and extraction time were evaluated. The optimised method (polyacrylate fibre; 20% Na2SO4; pH 2.0; 60 min; 20 °C) was applied for reservoir chlorinated water samples-either natural or spiked with MX (50 ng L-1 and 100 ng L-1). The recovery of MX ranged from 44 to 72%. Quantification of MX in water samples was done using external standard and the selected ion monitoring mode. Correlation coefficient (0.98%), relative standard deviation (5%), limit of detection (30 ng L-1) and limit of quantification (50 ng L-1) were obtained from calibration curve.