976 resultados para Linear range


Relevância:

60.00% 60.00%

Publicador:

Resumo:

ε-Caprolactam (CAP) is a monomer of nylon 6 used as food packaging for bologna sausage, turkey blanquettes, fowl breast, pâtés and ham luncheon meat. After polymerization a part of the monomer can remain in the packaging and migrate into the food. The aim of this work was develop and validate a single laboratory method to determine CAP in ethanol 95% that simulates fatty food characteristics. Thus, linear range was 2 to 32 mg/L of CAP, detection and quantification limits were 0.83 and 1.63 mg/L, respectively. Repeatability showed Hor Rat values lower than 2 while recovery range was 97.5 to 106.5%. The method was considered adequate for purpose.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

It was found that cinnamic acid can react with potassium permanganate in the acidic medium and produce chemiluminescence, which was greatly enhanced by glyoxal. Under the optimum conditions, the linear range for the determination of cinnamic acid was 1.0×10-8 to 1.0×10-4 mol L-1 with a detection limit of 8.0×10-9 mol L-1, the relative standard deviation was 1.7% for 2.0×10-6 mol L-1 cinnamic acid solution in nine repeated measurements. This method was found to be novel0simple0fast and sensitive, it was successfully applied to the determination of cinnamic acid in human urine. Furthermore, the possible reaction mechanism was also discussed.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A simple and sensitive method has been proposed for the determination of sibutramine-HCl in energy drinks, green tea and pharmaceutical formulations using differential pulse voltammetry performed on a hanging mercury drop electrode. In the chosen experimental condition (Mcllvaine pH 4.0 buffer, 50 mV pulse amplitude and 40 mV s-1 scan velocity), sibutramine-HCl presented a reversible behavior and a peak maximum at -80 mV. Detection limit was 0.4 mg L-1 and the working linear range extended up to 33.3 mg L-1 (r = 0.99). Analysis of real and fortified samples enabled recoveries between 91 and 102%. The electroanalytical method was compared with a HPLC method which indicated it accuracy.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A fast analytical method for determination of hydroquinone in pharmaceutical formulations employing batch injection analysis (BIA) with amperometric detection using a boron-doped diamond electrode is described. The supporting electrolyte was a 0.1 mol L-1 H2SO4 solution (the single reagent used for analysis). The method showed good repeatability (RSD of 0.45%, n=20), wide linear range (from 10 to 2000 µmol L-1, R=0.9999), low detection limit (0.016 µmol L-1) and satisfactory recovery values (91-96%). Accuracy of the method was evaluated by comparative analyses using high-performance liquid-chromatography. The ability to replace the electronic pipette by disposable syringes (injection procedure) in BIA systems was also shown.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This work focused on the development and validation of an RP-HPLC-UV method for quantification of beta-lactam antibiotics in three pharmaceutical samples. Active principles analyzed were amoxicillin and ampicillin, in 3 veterinary drugs. Mobile phase comprised 5 mmol L-1 phosphoric acid solution at pH 2.00, acetonitrile with gradient elution mode and detection wavelength at 220 nm. The method was validated according to the Brazilian National Health Surveillance regulation, where linear range and linearity, selectivity, precision, accuracy and ruggedness were evaluated. Inter day precision and accuracy for pharmaceutical samples 1, 2 and 3 were: 1.43 and 1.43%; 4.71 and 3.74%; 2.72 and 1.72%, respectively, while regression coefficients for analytical curves exceeded 0.99. The method had acceptable merit figure values, indicating reliable quantification. Analyzed samples had active principle concentrations varying from -12 to +21% compared to manufacturer label claims, rendering the medicine unsafe for administration to animals.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In this research, scanometry was used as a new, simple, fast and inexpensive method for a colorimetric determination of Mn2+ ion in water samples and thermocouple wire through the use of periodate reagent in an acidic medium. The results showed the oxidization of colorless Mn2+ ion by periodate and the formation of a purplish MnO4- ion. The system had a linear range of 1.0 to 70.0 µg mL-1 Mn2+ ion with a detection limit of 0.314 µg mL-1 and a relative standard deviation of 2.77% for G color value. This method has the capability to determine low levels of Mn2+ ion in thermocouple wire and water samples.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The binding of [Ru(PAN)(PPh3)2(ISN)]Cl (PAN = 1-(2'-Pyridylazo)-2-naphtholate) to bovine serum albumin (BSA) was investigated by spectroscopic techniques. According to analysis of the results from the Stern-Volmer equation, the ruthenium complex is able to quench the fluorescence intensity of BSA via a dynamic mechanism. The thermodynamic parameters were calculated (ΔH = 30.3 kJ mol-1; ΔS = 195.4 J mol-1 K-1), indicating that hydrophobic force is the main interaction driving force. The site marker competitive experiments revealed that the binding site of ruthenium complex was in the sub-domain IIA of BSA. FTO glass with a film of BSA-[Ru(PAN)(PPh3)2(ISN)]Cl was used as an ascorbic acid sensor. The linear range of the modified electrode was between 1 and 8 × 10-6 mol L-1.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

AbstractThis work describes the development of a biosensor based on the tyrosinase enzyme (Tyr) for the determination of phenol (PHEN) in laboratory effluent samples derived from ammoniacal nitrogen analysis of the water samples from the Muquém dam in the city of Cariús, CE, using square-wave voltammetry (SWV). The electrode modification consisted of the immobilization of gold nanoparticles, multi-walled carbon nanotubes, cobalt phthalocyanine, and Tyr on a glassy carbon electrode. The electrolyte, pH, enzyme quantity, and voltammetric parameters were optimized to detect PHEN. The analytical curves presented a linear range from 4.97 × 10-6 mol L-1 to 6.10 × 10-5 mol L-1, and the detection limit (DL) and quantitation limit (QL) values were 4.81 × 10-6 mol L-1 and 4.97 × 10-6mol L-1, respectively. The repetition of measurements with the same biosensor and repetition for three other prepared biosensors exhibited a relative standard deviation (RSD) of 5.50 and 1.75%, respectively. The percentage recovery of PHEN in effluent samples varied from 86.40 to 105.04%. The stability of the biosensor was evaluated (at 21 days) with satisfactory results, showing 97.86% of the initial response. Moreover, the DL and recovery percentages agreed with the established values from CONAMA and ABNT, respectively. Thus, the electrode configuration developed seems a promising tool in the detection and quantification of PHEN in complex samples.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper describes a comparative study between the procedures of deconvolution and the second-order derivative of square wave voltammograms to achieve separation of the voltammetric peaks of levofloxacin (LEVO) and norfloxacin (NOR), for their simultaneous quantification in urine samples. The obtained results indicate that the use of second-derivative voltammograms coupled with carbon screen-printed electrodes is the most efficient approach for completely separating the voltammetric peaks of LEVO and NOR. In addition, this approach has produced detection limits lower than 1.0 µmol L-1 and a wide linear range for both drugs. The proposed method was successfully used to simultaneously determine LEVO and NOR in spiked human and bovine urine samples with recovery percentages close to 100% for all analyzed samples.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In this work is proposed a solid phase preconcentration system of Co2+ ions and its posterior determination by GFAAS in which fractional factorial design and response surface methodology (RSM) were used for optimization of the variables associated with preconcentration system performance. The method is based on cobalt extraction as a complex Co2+-PAN (1:2) in a mini-column of polyurethane foam (PUF) impregnated with 1-(2-pyridylazo)-naphthol (PAN) followed by elution with HCl solution and its determination by GFAAS. The chemical and flow variables studied were pH, buffer concentration, eluent concentration and preconcentration and elution flow rates. Results obtained from fractional factorial design 2(5-1) showed that only the variables pH, buffer concentration and interaction (pH X buffer concentration) based on analysis of variance (ANOVA) were statistically significant at 95% confidence level. Under optimised conditions, the method provided an enrichment factor of 11.6 fold with limit of detection and quantification of 38 and 130 ng L-1, respectively, and linear range varying from 0.13 to 10 µg L-1. The precision (n = 9) assessed by relative standard deviation (RSD) was respectively 5.18 and 2.87% for 0.3 and 3.0 µg L-1 cobalt concentrations.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In this paper, a new, simple and sensitive method for arsenic determination in soil is proposed. This is based on the reduction of silver (I) and iron (III) ions by arsine followed by a complexation reaction of iron (II) with the spectrophotometric reagent Br-PADAP 2-(5-bromo-2-pyridylazo)-5-di-ethylaminophenol. Arsenic determination with a Sandell's sensitivity of 3.1 10-4 cm-2, linear range from 0.1 µg ml-1 to 2.0 µg ml-1 (r560 = 0.9995), molar absorptivity of 2.45 10(5) l mol-1 cm-1 and a concentration detection limit of 1.4 ng ml-1 (3s) were obtained using a 10 ml sample volume. Selectivity was increased with the use of EDTA as a masking agent. The proposed method was applied for arsenic determination in the presence of several ions amounts in digested soil samples. The results revealed that antimony (III), mercury (II), germanium (IV), platinum (IV) interferes at all analyzed proportions. The interferences can be easily removed by the use of EDTA. Precision and accuracy obtained were satisfactory with a R.S.D. < 5 %. Recovery of arsenic in soil samples varied from 95.55 to 102.70 % with a mean of 99.63 %. These results demonstrated that the proposed method is applicable for arsenic analysis in different soil samples.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A simple analytical method for quantification of atenolol in pharmaceutical formulations by diffuse reflectance spectroscopy is described. The method is based on the reaction, on the filter paper surface, between the drug and p-chloranil producing a colored compound. The best reaction conditions were obtained with 20 µL of atenolol solution and 20 µL of p-chloranil. All reflectance measurements were carried out at 550 nm and the linear range was from 1.13x10-2 to 7.88x10-2 mol L-1 (r = 0.9992). The limit of detection was 2.80 x 10-3 mol L-1. The proposed method was successfully applied to analysis of different commercial brands of pharmaceutical formulations and the results obtained by the proposed method were in good agreement with those obtained using the British Pharmacopoeia method.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A method for determination of organohalogen pesticides in strawberry by gas chromatography with electron capture detection was validated and applied in a monitoring program. Linearity, matrix effects, and day effect were evaluated for the analytes alpha-endosulfan, beta-endosulfan, endosulfan sulphate, lambda-cyhalothrin, procymidone, and trifluralin. The linear range varied according to the chromatographic response of the analyte. Significant matrix effects were observed. The mean recoveries ranged from 74.6 to 115.4%, with repeatability standard deviations between 1.6 and 21.0% and intermediate precision between 5.9 and 21.0%. Detection, quantification and decision limit, and detection capacity ranged from 0.003 to 0.007 mg/kg, 0.005 to 0.013 mg/kg; 0.003 to 3.128 mg/kg; and 0.005 to 3.266 mg/kg, respectively. The method was fit for the purpose of monitoring organohalogen residues in strawberries. Residues of these pesticides were detected in 124 of the 186 samples analyzed between 2009 and 2011 in the state of Minas Gerais. Nine of them did not comply with the current legislation requirements; among them, seven (3.8%) had residues of unauthorized pesticide for the culture of strawberry, one (0.5%) had residues above the maximum residue limit, and another one (0.5%) exhibited both non-conformities.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Flow injection analysis (FIA) was applied to the determination of both chloride ion and mercury in water. Conventional FIA was employed for the chloride study. Investigations of the Fe3 +/Hg(SCN)2/CI-,450 nm spectrophotometric system for chloride determination led to the discovery of an absorbance in the 250-260 nm region when Hg(SCN)2 and CI- are combined in solution, in the absence of iron(III). Employing an in-house FIA system, absorbance observed at 254 nm exhibited a linear relation from essentially 0 - 2000 Jlg ml- 1 injected chloride. This linear range spanning three orders of magnitude is superior to the Fe3+/Hg(SCN)2/CI- system currently employed by laboratories worldwide. The detection limit obtainable with the proposed method was determin~d to be 0.16 Jlg ml- 1 and the relative standard deviation was determined to be 3.5 % over the concentration range of 0-200 Jig ml- 1. Other halogen ions were found to interfere with chloride determination at 254 nm whereas cations did not interfere. This system was successfully applied to the determination of chloride ion in laboratory water. Sequential injection (SI)-FIA was employed for mercury determination in water with the PSA Galahad mercury amalgamation, and Merlin mercury fluorescence detection systems. Initial mercury in air determinations involved injections of mercury saturated air directly into the Galahad whereas mercury in water determinations involved solution delivery via peristaltic pump to a gas/liquid separator, after reduction by stannous chloride. A series of changes were made to the internal hardware and valving systems of the Galahad mercury preconcentrator. Sequential injection solution delivery replaced the continuous peristaltic pump system and computer control was implemented to control and integrate all aspects of solution delivery, sample preconcentration and signal processing. Detection limits currently obtainable with this system are 0.1 ng ml-1 HgO.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Le dioxyde de carbone (CO2) est un résidu naturel du métabolisme cellulaire, la troisième substance la plus abondante du sang, et un important agent vasoactif. À la moindre variation de la teneur en CO2 du sang, la résistance du système vasculaire cérébral et la perfusion tissulaire cérébrale subissent des changements globaux. Bien que les mécanismes exacts qui sous-tendent cet effet restent à être élucidés, le phénomène a été largement exploité dans les études de réactivité vasculaire cérébrale (RVC). Une voie prometteuse pour l’évaluation de la fonction vasculaire cérébrale est la cartographie de la RVC de manière non-invasive grâce à l’utilisation de l’Imagerie par Résonance Magnétique fonctionnelle (IRMf). Des mesures quantitatives et non-invasives de de la RVC peuvent être obtenus avec l’utilisation de différentes techniques telles que la manipu- lation du contenu artériel en CO2 (PaCO2) combinée à la technique de marquage de spin artériel (Arterial Spin Labeling, ASL), qui permet de mesurer les changements de la perfusion cérébrale provoqués par les stimuli vasculaires. Toutefois, les préoccupations liées à la sensibilité et la fiabilité des mesures de la RVC limitent de nos jours l’adoption plus large de ces méthodes modernes de IRMf. J’ai considéré qu’une analyse approfondie ainsi que l’amélioration des méthodes disponibles pourraient apporter une contribution précieuse dans le domaine du génie biomédical, de même qu’aider à faire progresser le développement de nouveaux outils d’imagerie de diagnostique. Dans cette thèse je présente une série d’études où j’examine l’impact des méthodes alternatives de stimulation/imagerie vasculaire sur les mesures de la RVC et les moyens d’améliorer la sensibilité et la fiabilité de telles méthodes. J’ai aussi inclus dans cette thèse un manuscrit théorique où j’examine la possible contribution d’un facteur méconnu dans le phénomène de la RVC : les variations de la pression osmotique du sang induites par les produits de la dissolution du CO2. Outre l’introduction générale (Chapitre 1) et les conclusions (Chapitre 6), cette thèse comporte 4 autres chapitres, au long des quels cinq différentes études sont présentées sous forme d’articles scientifiques qui ont été acceptés à des fins de publication dans différentes revues scientifiques. Chaque chapitre débute par sa propre introduction, qui consiste en une description plus détaillée du contexte motivant le(s) manuscrit(s) associé(s) et un bref résumé des résultats transmis. Un compte rendu détaillé des méthodes et des résultats peut être trouvé dans le(s) dit(s) manuscrit(s). Dans l’étude qui compose le Chapitre 2, je compare la sensibilité des deux techniques ASL de pointe et je démontre que la dernière implémentation de l’ASL continue, la pCASL, offre des mesures plus robustes de la RVC en comparaison à d’autres méthodes pulsés plus âgées. Dans le Chapitre 3, je compare les mesures de la RVC obtenues par pCASL avec l’utilisation de quatre méthodes respiratoires différentes pour manipuler le CO2 artérielle (PaCO2) et je démontre que les résultats peuvent varier de manière significative lorsque les manipulations ne sont pas conçues pour fonctionner dans l’intervalle linéaire de la courbe dose-réponse du CO2. Le Chapitre 4 comprend deux études complémentaires visant à déterminer le niveau de reproductibilité qui peut être obtenu en utilisant des méthodes plus récentes pour la mesure de la RVC. La première étude a abouti à la mise au point technique d’un appareil qui permet des manipulations respiratoires du CO2 de manière simple, sécuritaire et robuste. La méthode respiratoire améliorée a été utilisée dans la seconde étude – de neuro-imagerie – où la sensibilité et la reproductibilité de la RVC, mesurée par pCASL, ont été examinées. La technique d’imagerie pCASL a pu détecter des réponses de perfusion induites par la variation du CO2 dans environ 90% du cortex cérébral humain et la reproductibilité de ces mesures était comparable à celle d’autres mesures hémodynamiques déjà adoptées dans la pratique clinique. Enfin, dans le Chapitre 5, je présente un modèle mathématique qui décrit la RVC en termes de changements du PaCO2 liés à l’osmolarité du sang. Les réponses prédites par ce modèle correspondent étroitement aux changements hémodynamiques mesurés avec pCASL ; suggérant une contribution supplémentaire à la réactivité du système vasculaire cérébral en lien avec le CO2.