946 resultados para Lenses.


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Silicone hydrogel (SiH) contact lenses have been available for over a decade. During that time, these highly innovative materials and designs have continually improved and now represent a major percentage of fits within the global contact lens market.1 Their high oxygen transmissibility has drastically reduced the incidence of hypoxia-related conditions such as corneal edema, limbal hyperaemia, and corneal vascularisation.2,3 However, there remain significant challenges in the quest for the ideal contact lens. The silicone material used in SiH contact lenses is inherently more hydrophobic than the non-silicone hydrogel materials. SiH lens manufacturers must find ways to overcome lens surface hydrophobicity since it can create issues in terms of lens wettability and surface deposition. Achieving ideal lens water content presents yet another challenge since increasing water content in a silicone hydrogel lens can reduce oxygen transmissibility. This is because increasing water content results in decreased silicone content in the lens and silicone is a better transmitter of oxygen than water.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Contrary to what many practitioners believe, current generation contact lenses are easy to fit, are well tolerated, provide superior vision, are physiologically compatible with the anterior ocular structures, cause few serious complications and are cost effective. These factors will be explored with examples of advancements that have occurred in contact lens practice over the past two decades. Consideration will also be given to the role of optometrists, the contact lens industry and educational institutions in promoting contact lenses as an alternative form of vision correction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose:Multifocal contact lenses (MCLs) have been available for decades. A review of the literature suggests that while, historically, these lenses have been partially successful, they have struggled to compete with monovision (MV). More recent publications suggest that there has been an improvement in the performance of these lenses. This study set out to investigate whether the apparent improved lens performance reported in the literature is reflected in clinical practice. Methods:Data collected over the last 5yrs via the International Contact Lens Prescribing Survey Consortium was reviewed for patients over the age of 45yrs. The published reports of clinical trials were reviewed to assess lens performance over the time period. Results:Data review was of 16,680 presbyopic lens fits in 38 countries. The results are that 29% were fit with MCLs, 8% MV and 63% single vision (SV). A previous survey conducted in Australia during 1988-89 reported that 9% of presbyopes were fit with MCLs, 29% MV and 63% SV. The results from our survey for Australia alone were 28% (MV 13%) vs 9% (MV 29%) suggesting an increase in usage of MCLs from 1988-89 to 2010. A review of the literature indicates the reported level of visual acuities with MCLs in comparison to MV has remained equivalent over this time period, yet preference has switch from MV to MCLs. Conclusions:There is evidence that currently more MCLs than MV are being fit to presbyopes, compared to 1988-89. This increased use is likely due to the improved visual performance of these lenses, which is not demonstrated with acuity measures but reported by wearers, suggesting that patient-based subjective ratings are currently the best way to measure visual performance.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rigid lenses, which were originally made from glass (between 1888 and 1940) and later from polymethyl methacrylate or silicone acrylate materials, are uncomfortable to wear and are now seldom fitted to new patients. Contact lenses became a popular mode of ophthalmic refractive error correction following the discovery of the first hydrogel material – hydroxyethyl methacrylate – by Czech chemist Otto Wichterle in 1960. To satisfy the requirements for ocular biocompatibility, contact lenses must be transparent and optically stable (for clear vision), have a low elastic modulus (for good comfort), have a hydrophilic surface (for good wettability), and be permeable to certain metabolites, especially oxygen, to allow for normal corneal metabolism and respiration during lens wear. A major breakthrough in respect of the last of these requirements was the development of silicone hydrogel soft lenses in 1999 and techniques for making the surface hydrophilic. The vast majority of contact lenses distributed worldwide are mass-produced using cast molding, although spin casting is also used. These advanced mass-production techniques have facilitated the frequent disposal of contact lenses, leading to improvements in ocular health and fewer complications. More than one-third of all soft contact lenses sold today are designed to be discarded daily (i.e., ‘daily disposable’ lenses).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The deposition of biological material (biofouling) onto polymeric contact lenses is thought to be a major contributor to lens discomfort and hence discontinuation of wear. We describe a method to characterize lipid deposits directly from worn contact lenses utilizing liquid extraction surface analysis coupled to tandem mass spectrometry (LESA-MS/MS). This technique effected facile and reproducible extraction of lipids from the contact lens surfaces and identified lipid molecular species representing all major classes present in human tear film. Our data show that LESA-MS/MS is a rapid and comprehensive technique for the characterization of lipid-related biofouling on polymer surfaces.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Whether the first daily disposable soft contact lens to enter the market in 1994 was the Premier lens (Award Technology, Scotland, UK; subsequently purchased by Bausch & Lomb, Rochester New York, USA) or the 1-Day Acuvue lens (Johnson and Johnson Vision Care, Jacksonville, Florida, USA) has long been a matter of bitter dispute1 but whatever the answer, this year marks the 20th anniversary of the launch of this modality of lens wear...

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Photographers from community and mainstream media organisations bring the everyday of favela communities to the attention of Rio de Janeiro’s society from different perspectives. While mainstream photojournalists mainly report on favelas from outside to inside, denouncing wrongdoings and human rights abuses, community photographers do it from the opposite direction, from inside to outside, presenting images of the everyday life of favela communities. This paper takes an ethnographic and discursive approach to comparing these two categories of photographers to ask how their different practices can yield benefits for the people living in marginalised communities. Furthermore, by adapting Foucault and Bourdieu’s theories, this study examines photographers’ habitus so as to determine how cultural capital and economic capital that they possess shape their subjectivity and, as such, the fields of community and mainstream photojournalism. This study has no intention of creating polarised distinctions between community and mainstream photojournalism. Instead, the research aims, through the investigation of the working practices, identities, and discourses of photographers from community and mainstream media organisations, to identify the activities and limitations of both community and mainstream in order to build an understanding about how the media ecology works best within both.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We thank Dr Shedden and Dr Pall for their insightful comments and the opportunity to clarify a number of points from our work.1 The “protection factor” (PF) expressed as the inverse of the transmittance of contact lens (CL) material (1/Tλ), where T is the percentage transmittance of ultraviolet radiation (UVR) in a given waveband (UVC, UVB or UVA) of the UV spectrum for contact lenses is the standard method for reporting PF values and as such there should not be any controversy. We have calculated the PF for each wavelength across the entire UV spectrum (UVC, UVB, UVA) as presented in figure 3 of our previous publication.1 In that article, we were simply stating the observation when transmission in the UVC spectra band is considered especially because appreciable amounts of potentially carcinogenic short UV wavelengths was shown to be present in sunlight in our region three decades ago2 and these short wavelength photons are reported to be more biologically damaging to ocular tissues.3 In addition, the depletion of the Ozone layer is still continuing. Nevertheless, we understand the concern of the authors that the results of the PF might be confusing to those who are not familiar with the science of UVR and as such we have made some revisions to the findings of the calculated PF...

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose To evaluate the influence of cone location and corneal cylinder on RGP corrected visual acuities and residual astigmatism in patients with keratoconus. Methods In this prospective study, 156 eyes from 134 patients were enrolled. Complete ophthalmologic examination including manifest refraction, Best spectacle visual acuity (BSCVA), slit-lamp biomicroscopy was performed and corneal topography analysis was done. According to the cone location on the topographic map, the patients were divided into central and paracentral cone groups. Trial RGP lenses were selected based on the flat Sim K readings and a ‘three-point touch’ fitting approach was used. Over contact lens refraction was performed, residual astigmatism (RA) was measured and best-corrected RGP visual acuities (RGPVA) were recorded. Results The mean age (±SD) was 22.1 ± 5.3 years. 76 eyes (48.6%) had central and 80 eyes (51.4%) had paracentral cone. Prior to RGP lenses fitting mean (±SD) subjective refraction spherical equivalent (SRSE), subjective refraction astigmatism (SRAST) and BSCVA (logMAR) were −5.04 ± 2.27 D, −3.51 ± 1.68 D and 0.34 ± 0.14, respectively. There were statistically significant differences between central and paracentral cone groups in mean values of SRSE, SRAST, flat meridian (Sim K1), steep meridian (Sim K2), mean K and corneal cylinder (p-values < 0.05). Comparison of BSCVA to RGPVA shows that vision has improved 0.3 logMAR by RGP lenses (p < 0.0001). Mean (±SD) RA was −0.72 ± 0.39 D. There were no statistically significant differences between RGPVAs and RAs of central and paracentral cone groups (p = 0.22) and (p = 0.42), respectively. Pearson's correlation analysis shows that there is a statistically significant relationship between corneal cylinder and BSCVA and RGPVA, However, the relationship between corneal cylinder and residual astigmatism was not significant. Conclusions Cone location has no effect on the RGP corrected visual acuities and residual astigmatism in patients with keratoconus. Corneal cylinder and Sim K values influence RGP-corrected visual acuities but do not influence residual astigmatism.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Systematic reviews and meta-analyses are used to combine results across studies to determine an overall effect. Meta-analysis is especially useful for combining evidence to inform social policy, but meta-analyses of applied social science research may encounter practical issues arising from the nature of the research domain. The current paper identifies potential resolutions to four issues that may be encountered in systematic reviews and meta-analyses in social research. The four issues are: scoping and targeting research questions appropriate for meta-analysis; selecting eligibility criteria where primary studies vary in research design and choice of outcome measures; dealing with inconsistent reporting in primary studies; and identifying sources of heterogeneity with multiple confounded moderators. The paper presents an overview of each issue with a review of potential resolutions, identified from similar issues encountered in meta-analysis in medical and biological sciences. The discussion aims to share and improve methodology in systematic reviews and meta-analysis by promoting cross-disciplinary communication, that is, to encourage 'viewing through different lenses'.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose To investigate if the accuracy of intraocular pressure (IOP) measurements using rebound tonometry over disposable hydrogel (etafilcon A) contact lenses (CL) is affected by the positive power of the CLs. Methods The experimental group comprised 26 subjects, (8 male, 18 female). IOP measurements were undertaken on the subjects’ right eyes in random order using a Rebound Tonometer (ICare). The CLs had powers of +2.00D and +6.00D. Measurements were taken over each contact lens and also before and after the CLs had been worn. Results The IOP measure obtained with both CLs was significantly lower compared to the value without CLs (t test; p<0.001) but no significant difference was found between the two powers of CLs. Conclusions Rebound tonometry over positive hydrogel CLs leads to a certain degree of IOP underestimation. This result didn’t change for the two positive lenses used in the experiment, despite their large difference in power and therefore in lens thickness. Optometrists should bear this in mind when measuring IOP with the rebound tonometer over plus power contact lenses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the study, we used the Agilent 8453 spectrophotometer (which is equipped with a limiting aperture that restricts the light beam to the central 5 mm of the contact lens), to measure the transmittance of various coloured contact lenses including the one Day Acuvue define manufactured by Johnson and Johnson which the authors represent. We measured the instrument baseline before the transmittance spectra of lenses were tested. The values of lens transmittances were thus the difference between baseline and lens measurement at each time. The transmittance measurements were obtained at 0.5 nm intervals, from 200 to 700 nm after a soak in saline to remove the influence of any surface active agents within the packaging products. The technique used in our study was not very different from how other research studies [2], [3], [4], [5] and [6] have measured the spectra transmittances of contact lenses...

Relevância:

20.00% 20.00%

Publicador: