925 resultados para LOW-VOLTAGE
Resumo:
It is possible to prepare low‐voltage varistors from the zinc antimony spinel Zn7Sb2O12 with breakdown voltages in the range of 3–20 V and nonlinearity coefficient α=7–15. The varistor property is due to the formation of high ohmic potential barriers at the grain boundary regions on low‐ohmic n‐type grain interiors of the polycrystalline samples. The method of preparation of the spinel, synthesized by coprecipitation followed by annealing under restricted partial pressures of oxygen, controls the mixed valence states for antimony, namely, Sb3+ and Sb5+. This is critical in attaining high nonlinearity and lower breakdown voltages.
Resumo:
The firing characteristics of the simple triggered vacuum gap (TVG) using lead zirconate titanate as dielectric material in the triggered gap are described. This TVG has a long life of about 2000 firings without appreciable deterioration of the electrical properties for main discharge currents upto 3 kA and is much superior to these made with Supramica (Mycalex Corporation of America) and silicon carbide as used in our earlier investigations. The effects of the variation of trigger voltage, trigger curcit, trigger pulse duration, trigger pulse energy, main gap voltage, main gap separation and main circuit energy on the firing characteristics have been studied. Trigger resistance progressively decreases with the number of firings of the trigger gap and as well as of the main gap. This decrease in the trigger resistance is more pronounced for main discharge currents exceeding 10 kA. The minimum trigger current required for reliable firing decreases with increase of trigger voltage upto a threshold value of 1.2 kV and there-onwards saturates at 3.0 A. This value is less than that obtained with Supramica as dielectric material. One hundred percent firing probability of the TVG at main gap voltages as low as 50 V is possible and this low voltage breakdown of the main gap appears to be similar to the breakdown at low pressures between moving plasma by other workers. and the cold electrodes immersed in it, as reported.
Resumo:
This paper presents a low energy memory decoder architecture for ultra-low-voltage systems containing multiple voltage domains. Due to limitations in scalability of memory supply voltages, these systems typically contain a core operating at subthreshold voltages and memories operating at a higher voltage. This difference in voltage provides a timing slack on the memory path as the core supply is scaled. The paper analyzes the feasibility and trade-offs in utilizing this timing slack to operate a greater section of memory decoder circuitry at the lower supply. A 256x16-bit SRAM interface has been designed in UMC 65nm low-leakage process to evaluate the above technique with the core and memory operating at 280 mV and 500 mV respectively. The technique provides a reduction of up to 20% in energy/cycle of the row decoder without any penalty in area and system-delay.
Resumo:
A neonatal temperature monitoring system operating in subthreshold regime that utilizes time mode signal processing is presented. Resistance deviations in a thermistor due to temperature variations are converted to delay variations that are subsequently quantized by a Delay measurement unit (DMU). The DMU does away with the need for any analog circuitry and is synthesizable entirely from digital logic. An FPGA implementation of the system demonstrates the viability of employing time mode signal processing, and measured results show that temperature resolution better than 0.1 degrees C can be achieved using this approach.
Resumo:
Electrowetting is one of the most effective methods to enhance wettability. A significant change of contact angle for the liquid droplet can result from the surface microstructures and the external electric field, without altering the chemical composition of the system. During the electrowetting process on a rough surface, the droplet exhibits a sharp transition from the Cassie-Baxter to the Wenzel regime at a low critical voltage. In this paper, a theoretical model for electrowetting is put forth to describe the dynamic electrical control of the wetting behavior at the low voltage, considering the surface topography. The theoretical results are found to be in good agreement with the existing experimental results. (c) Koninklijke Brill NV, Leiden, 2008.
Resumo:
246 p.
Resumo:
The Brushless Doubly-Fed Induction Generator (BDFIG) shows commercial promise for wind power generation due to its lower cost and higher reliability compared to the Doubly-Fed Induction Generator (DFIG). For the purposes of commercialisation, the BDFIG must meet grid codes at all times. Nowadays, all new wind generators have to ride through certain grid faults, and the Low-Voltage Ride Through (LVRT) capability has become one of the most important points on which to assess the performance a generator. This paper, for the first time, proposes a control scheme to enable the the BDFIG to ride through symmetrical voltage dips. Simulation results and experimental results on a prototype BDFIG show that the proposed scheme gives the capability to ride through low voltage faults. © 2011 IEEE.
Resumo:
The Brushless Doubly-Fed Induction Generator (Brushless DFIG) shows commercial promise for wind power generation due to its lower cost and higher reliability when compared with the conventional Doubly-Fed Induction Generator (DFIG). In the most recent grid codes, wind generators are required to be able to ride through a low voltage fault and meet the reactive current demand from the grid. Hence, a Low-Voltage Ride-Through (LVRT) capability is important for wind generators which are integrated into the grid. In this paper the authors propose a control strategy enabling the Brushless DFIG to successfully ride through a symmetrical voltage dip. The control strategy has been implemented on a 250 kW Brushless DFIG and the experimental results indicate that LVRT is possible without a crowbar.
Resumo:
Compared with the Doubly fed induction generators (DFIG), the brushless doubly fed induction generator (BDFIG) has a commercial potential for wind power generation due to its lower cost and higher reliability. In the most recent grid codes, wind generators are required to be capable of riding through low voltage faults. As a result of the negative sequence, induction generators response differently in asymmetrical voltage dips compared with the symmetrical dip. This paper gave a full behavior analysis of the BDFIG under different types of the asymmetrical fault and proposed a novel control strategy for the BDFIG to ride through asymmetrical low voltage dips without any extra hardware such as crowbars. The proposed control strategies are experimentally verified by a 250-kW BDFIG. © 2012 IEEE.
Resumo:
Significant improvements in the spatial and temporal uniformities of device switching parameters are successfully demonstrated in Ge/TaOx bilayer-based resistive switching devices, as compared with non-Ge devices. In addition, the reported Ge/TaOx devices also show significant reductions in the operation voltages. Influence of the Ge layer on the resistive switching of TaOx-based resistive random access memory is investigated by X-ray spectroscopy and the theory of Gibbs free energy. Higher uniformity is attributed to the confinement of the filamentary switching process. The presence of a larger number of interface traps, which will create a beneficial electric field to facilitate the drift of oxygen vacancies, is believed to be responsible for the lower operation voltages in the Ge/TaO x devices. © 1980-2012 IEEE.
Resumo:
The brushless doubly fed induction generator (BDFIG) has been proposed as a viable alternative in wind turbines to the commonly used doubly fed induction generator (DFIG). The BDFIG retains the benefits of the DFIG, i.e. variable speed operation with a partially rated converter, but without the use of brush gear and slip rings, thereby conferring enhanced reliability. As low voltage ride-through (LVRT) performance of the DFIG-based wind turbine is well understood, this paper aims to analyze LVRT behavior of the BDFIG-based wind turbine in a similar way. In order to achieve this goal, the equivalence between their two-axis model parameters is investigated. The variation of flux linkages, back-EMFs and currents of both types of generator are elaborated during three phase voltage dips. Moreover, the structural differences between the two generators, which lead to different equivalent parameters and hence different LVRT capabilities, are investigated. The analytical results are verified via time-domain simulations for medium size wind turbine generators as well as experimental results of a voltage dip on a prototype 250 kVA BDFIG. © 2014 Elsevier B.V.
Resumo:
National Natural Science Foundation of China 60536030 60776024 60877035 90820002 National High-Technology Research and Development Program of China 2007AA04Z329 2007AA04Z254