997 resultados para Indoor Climate


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Endemic northern malaria reached 68°N latitude in Europe during the 19th century, where the summer mean temperature only irregularly exceeded 16°C, the lower limit needed for sporogony of Plasmodium vivax. Because of the available historical material and little use of quinine, Finland was suitable for an analysis of endemic malaria and temperature. Methods: Annual malaria death frequencies during 1800–1870 extracted from parish records were analysed against long-term temperature records in Finland, Russia and Sweden. Supporting data from 1750–1799 were used in the interpretation of the results. The life cycle and behaviour of the anopheline mosquitoes were interpreted according to the literature. Results: Malaria frequencies correlated strongly with the mean temperature of June and July of the preceding summer, corresponding to larval development of the vector. Hatching of imagoes peaks in the middle of August, when the temperature most years is too low for the sporogony of Plasmodium. After mating some of the females hibernate in human dwellings. If the female gets gametocytes from infective humans, the development of Plasmodium can only continue indoors, in heated buildings. Conclusion: Northern malaria existed in a cold climate by means of summer dormancy of hypnozoites in humans and indoor transmission of sporozoites throughout the winter by semiactive hibernating mosquitoes. Variable climatic conditions did not affect this relationship. The epidemics, however, were regulated by the population size of the mosquitoes which, in turn, ultimately was controlled by the temperatures of the preceding summer.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Sugganahalli, a rural vernacular community in a warm-humid region in South India, is under transition towards adopting modern construction practices. Vernacular local building elements like rubble walls and mud roofs are given way to burnt brick walls and reinforced cement concrete (RCC)/tin roofs. Over 60% of Indian population is rural, and implications of such transitions on thermal comfort and energy in buildings are crucial to understand. Vernacular architecture evolves adopting local resources in response to the local climate adopting passive solar designs. This paper investigates the effectiveness of passive solar elements on the indoor thermal comfort by adopting modern climate-responsive design strategies. Dynamic simulation models validated by measured data have also been adopted to determine the impact of the transition from vernacular to modern material-configurations. Age-old traditional design considerations were found to concur with modern understanding into bio-climatic response and climate-responsiveness. Modern transitions were found to increase the average indoor temperatures in excess of 7 degrees C. Such transformations tend to shift the indoor conditions to a psychrometric zone that is likely to require active air-conditioning. Also, the surveyed thermal sensation votes were found to lie outside the extended thermal comfort boundary for hot developing countries provided by Givoni in the bio-climatic chart.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Muitos dos locais onde as atividades são realizadas nas academias de ginásticas são salas pequenas e fechadas com sistema de climatização artificial, freqüentados por um grande número de alunos realizando seus exercícios e profissionais auxiliando as atividades. Com isso, há uma intensa transpiração desses indivíduos, uma freqüente rotina de limpeza do piso e de equipamentos com pequenos intervalos, possibilitando a alterações da qualidade do ar indoor. O presente trabalho busca mostrar as tendências de variações nos valores das concentrações dos poluentes atmosféricos BTEX em ambiente indoor, especificamente na sala de spinning de uma academia de ginástica do Rio de Janeiro. Para o monitoramento da qualidade do ar foram utilizados cartuchos de carvão ativado SKC, acoplado a uma bomba KNF com vazão de 1l min. Para a extração de cada amostra foi feita a análise cromatográfica com cromatógrafo a gás modelo 6890 acoplado a um espectrômetro de massa modelo 5973 da marca Agilent. Foram analisadas 34 amostras coletadas na salas de spinning durante as aulas com atividades aeróbicas, o que intensificava a respiração dos indivíduos, possibilitando uma maior inalação destes COVs. Em contrapartida, também foram coletadas 5 amostras outdoor, 4 delas pareadas indoor/ outdoor para uma análise comparativa das concentrações destes poluentes. Dentre os compostos orgânicos voláteis analisados, o tolueno é o BTEX mais abundante obtido neste trabalho, representando 81% destes COVs indoor. Todas as amostras medidas em pares indoor/ outdoor tiveram concentrações maiores no interior, exceto para o benzeno no dia 3/12/2010. Simples atividades usualmente realizadas pelo homem, como a inserção de piso emborrachado, manutenção do sistema de climatização artificial, e limpeza podem alterar o ar indoor. As conclusões alcançadas após as medições das concentrações de BTEX foram de que o ar indoor estava mais poluído do que o outdoor. Este monitoramento da qualidade do ar indoor ainda é escasso no Brasil. Alguns esforços tem sido feito em relação a ambientes confinados como a Portaria n˚3523 do Ministério da Saúde, regulamentando o controle dos ambientes climatizados e a Resolução n˚9 da Agência Nacional de Vigilância Sanitária, além da Resolução CONAMA n ˚3 estabelecendo padrões de qualidade do ar para alguns compostos químicos, porém muitos compostos químicos ainda não são legislados ou não possuem a devida atenção, não sendo suficientes para contemplar a complexidade do assunto

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Social and political concerns are frequently reflected in the design of school buildings, often in turn leading to the development of technical innovations. One example is a recurrent concern about the physical health of the nation, which has at several points over the last century prompted new design approaches to natural light and ventilation. The most critical concern of the current era is the global, rather than the indoor, environment. The resultant political focus on mitigating climate change has resulted in new regulations, and in turn considerable technical changes in building design and construction. The vanguard of this movement has again been in school buildings, set the highest targets for reducing operational carbon by the previous Government. The current austerity measures have moved the focus to the refurbishment and retrofit of existing buildings, in order to bring them up to the exacting new standards. Meanwhile there is little doubt that climate change is happening already, and that the impacts will be considerable. Climate scientists have increasing confidence in their predictions for the future; if today’s buildings are to be resilient to these changes, building designers will need to understand and design for the predicted climates in order to continue to provide comfortable and healthy spaces through the lifetimes of the buildings. This paper describes the decision processes, and the planned design measures, for adapting an existing school for future climates. The project is at St Faith’s School in Cambridge, and focuses on three separate buildings: a large Victorian block built as a substantial domestic dwelling in 1885, a smaller single storey 1970s block with a new extension, and an as-yet unbuilt single storey block designed to passivhaus principles and using environmentally friendly materials. The implications of climate change have been considered for the three particular issues of comfort, construction, and water, as set out in the report on Design for Future Climate: opportunities for adaptation in the built environment (Gething, 2010). The adaptation designs aim to ensure each of the three very different buildings remains fit for purpose throughout the 21st century, continuing to provide a healthy environment for the children. A forth issue, the reduction of carbon and the mitigation of other negative environmental impacts of the construction work, is also a fundamental aim for the school and the project team. Detailed modelling of both the operational and embodied energy and carbon of the design options is therefore being carried out, in order that the whole life carbon costs of the adaptation design options may be minimised. The project has been funded by the Technology Strategy Board as part of the Design for Future Climates programme; the interdisciplinary team includes the designers working on the current school building projects and the school bursar, supported by researchers from the University of Cambridge Centre for Sustainable Development. It is hoped that lessons from the design process, as well as the solutions themselves, will be transferable to other buildings in similar climatic regions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents an investigation of the natural ventilation cooling potential (NVCP) of office buildings in the five generally recognised climate zones in China using the Thermal Resistance Ventilation (TRV) model, which is a simplified, coupled, thermal and airflow model. The acceptable operative temperature for naturally conditioned space supplied by the ASHARE Standard 55-2004 has been used for the comfort temperature setting. Dynamic simulations for a typical office room in the five representative cities, which are Harbin, Beijing, Shanghai, Kunming and Guangzhou, have been carried out. The study demonstrates that the NVCP depends on the multiple impacts of climate, the building's thermal characteristics, internal gains, ventilation profiles and regimes. The work shows how the simplified method can be used to generate detailed, indoor, operative temperature data based on the various building conditions and control profiles which are used to investigate the NVCP at the strategic design stage. The simulation results presented in this paper can be used as a reference guideline for natural ventilation design in China.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We investigate the spatial characteristics of urban-like canopy flow by applying particle image velocimetry (PIV) to atmospheric turbulence. The study site was a Comprehensive Outdoor Scale MOdel (COSMO) experiment for urban climate in Japan. The PIV system captured the two-dimensional flow field within the canopy layer continuously for an hour with a sampling frequency of 30 Hz, thereby providing reliable outdoor turbulence statistics. PIV measurements in a wind-tunnel facility using similar roughness geometry, but with a lower sampling frequency of 4 Hz, were also done for comparison. The turbulent momentum flux from COSMO, and the wind tunnel showed similar values and distributions when scaled using friction velocity. Some different characteristics between outdoor and indoor flow fields were mainly caused by the larger fluctuations in wind direction for the atmospheric turbulence. The focus of the analysis is on a variety of instantaneous turbulent flow structures. One remarkable flow structure is termed 'flushing', that is, a large-scale upward motion prevailing across the whole vertical cross-section of a building gap. This is observed intermittently, whereby tracer particles are flushed vertically out from the canopy layer. Flushing phenomena are also observed in the wind tunnel where there is neither thermal stratification nor outer-layer turbulence. It is suggested that flushing phenomena are correlated with the passing of large-scale low-momentum regions above the canopy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Designing for indoor thermal environmental conditions is one of the key elements in the energy efficient building design process. This paper introduces a development of the Chinese national Evaluation Standard for indoor thermal environments (Evaluation Standard). International standards including the ASHRAE55, ISO7730, DIN EN, and CIBSE Guide-A have been reviewed and referenced for the development of the Evaluation Standard. In addition, over 28,000 subjects participated in the field study from different climate zones in China and over 500 subjects have been involved in laboratory studies. The research findings reveal that there is a need to update the Chinese thermal comfort standard based on local climates and people's habitats. This paper introduces in detail the requirements for the thermal environment for heated and cooled buildings and free-running buildings in China.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper aims to critically examine the application of Predicted Mean Vote (PMV) in an air-conditioned environment in the hot-humid climate region. Experimental studies have been conducted in a climate chamber in Chongqing, China, from 2008 to 2010. A total of 440 thermal responses from participants were obtained. Data analysis reveals that the PMV overestimates occupants' mean thermal sensation in the warm environment (PMV > 0) with a mean bias of 0.296 in accordance with the ASHRAE thermal sensation scales. The Bland–Altman method has been applied to assess the agreement of the PMV and Actual Mean Vote (AMV) and reveals a lack of agreement between them. It is identified that habituation due to the past thermal experience of a long-term living in a specific region could stimulate psychological adaptation. The psychological adaptation can neutralize occupants’ actual thermal sensation by moderating the thermal sensibility of the skin. A thermal sensation empirical model and a PMV-revised index are introduced for air-conditioned indoor environments in hot-humid regions. As a result of habituation, the upper limit effective thermal comfort temperature SET* can be increased by 1.6 °C in a warm season based on the existing international standard. As a result, a great potential for energy saving from the air-conditioning system in summer could be achieved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Strong heat waves in the past decade and resulting legal cases which gave full responsibility for indoor thermal comfort to building professionals lead to an increased uncertainty how to maintain thermal comfort in offices without the use of a cooling system. Adaptive thermal comfort standards such as EN 15251 and Ashrae Standard 55 provide methodologies to evaluate comfort in naturally ventilated spaces. Based on a parametric study for a typical cellular office in the context of Athens, Greece, and using the building simulation software EnergyPlus, this study investigates the potentials for the applicability of natural ventilation in a Mediterranean climate. The Ashrae Standard 55 and EN 15251 adaptive thermal comfort models are compared in this context, and conclusions are drawn how the use of natural ventilation based on adaptive models can be further encourgaged.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aims: In the Mediterranean areas of Europe, leishmanisasis is one of the most emerging vector-borne diseases. Members of genus Phlebotomus are the primary vectors of the genus Leishmania. To track the human health effect of climate change it is a very important interdisciplinary question to study whether the climatic requirements and geographical distribution of the vectors of human pathogen organisms correlate with each other. Our study intended to explore the potential effects of ongoing climate change, in particular through a potential upward altitudinal and latitudinal shift of the distribution of the parasite Leishmania infantum, its vectors Phlebotomus ariasi, P. neglectus, P. perfiliewi, P. perniciosus, and P. tobbi, and some other sandfly species: P. papatasi, P. sergenti, and P. similis. Methods: By using a climate envelope modelling (CEM) method we modelled the current and future (2011-2070) potential distribution of 8 European sandfly species and L. infantum based on the current distribution using the REMO regional climate model. Results: We found that by the end of the 2060’s most parts of Western Europe can be colonized by sandfly species, mostly by P. ariasi and P. pernicosus. P. ariasi showed the greatest potential northward expansion. For all the studied vectors of L. infantum the entire Mediterranean Basin and South-Eastern Europe seemed to be suitable. L. infantum can affect the Eastern Mediterranean, without notable northward expansion. Our model resulted 1 to 2 months prolongation of the potentially active period of P. neglectus P. papatasi and P. perniciosus for the 2060’s in Southern Hungary. Conclusion: Our findings confirm the concerns that leishmanisais can become a real hazard for the major part of the European population to the end of the 21th century and the Carpathian Basin is a particularly vulnerable area.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Many species of fungi produce bioactive compounds called mycotoxins. These compounds are produced by filamentous fungi and can contaminate food, feeds and specific indoor environments resulting in high economic losses. Severe health problems and death have been related with mycotoxins exposure through the consumption of several food commodities. There are many factors involved in mycotoxin production by fungi but climate is the most important. Thus, when changes in the weather occur, mycotoxins production will be affected. We looked for articles that were available in scientific databases, written in English and that mention in the title and/or abstract the combined terms fungi and climate change and also mycotoxins and climate change.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Information about indoor air temperatures in residential buildings is of interest for a range of reasons, e.g. the health and comfort of occupants, energy demand for space heating and cooling. To date there have been few long term studies that measure and characterise indoor air temperatures in Australian homes. New primary research undertaken by the authors measured temperatures in 273 homes over the period 2011 to 2014 in seven climate zones, from Melbourne in the south to Cairns in the north of Australia. Humidity data was also collected in 20 homes. This paper is a description of the data collected and the subsequent analysis.

Indoor temperatures were compared with outdoor temperatures and a mathematical model was fitted to the data. In general, monthly average indoor temperatures were found to be 2 degreesC higher than monthly average outdoor temperatures, apart from periods with consistently cold weather, where the monthly average outdoor temperature was less than 20 degreesC, which were found to have larger differences. The indoor temperature model developed has been compared with data measured by the Commonwealth Scientific and Industrial Research Organisation (CSIRO) in 438 homes in three Australian cities. The model developed using project measurements are highly consistent with the CSIRO data.

Further data collection compared indoor and outdoor humidity in 20 houses in Sydney and Melbourne. The indoor humidity ratio was found to be, on average, slightly higher than outdoors, but indoor levels generally track outdoor levels quite closely. This is likely due to the high air exchange rate in most houses.