999 resultados para Impression material


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pós-graduação em Ciências Odontológicas - FOAR

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: To evaluate the effect of post-silanization heat treatment of a silane agent and rinsing with hot water of silanized CAD/CAM feldspathic ceramic surfaces on the microtensile bond strength between resin cement and the ceramic, before and after mechanical cycling.Materials and Methods: Blocks measuring 10 x 5.7 x 3.25 mm(3) were produced from feldspathic ceramic cubes (VITA Mark II, VITA Zanhfabrik). Each ceramic block was duplicated in composite resin using a template made of polyvinylsiloxane impression material. Afterwards, ceramic and corresponding resin composite blocks were ultrasonically cleaned and randomly divided according to the 5 strategies used for conditioning the ceramic surface (n = 10): GHF: etching with hydrofluoric acid 10% + rinsing with water at room temperature + silanization at 20 degrees C; G20: silanization; G77: silanization + oven drying at 77 degrees C; G20r: silanization + hot water rinsing; G77r: silanization + oven drying at 77 C + hot water rinsing. The resin and ceramic blocks were cemented using a dual-curing resin cement. Every group was divided in two subgroups: aging condition (mechanical cycling, designated as a) or non-aging (designated as n). All the bonded assemblies were sectioned into microsticks for microtensile bond strength (mu TBS) testing. The failure mode of the tested specimens was assessed and mu TBS data were statistically analyzed in two ways: first 2-way ANOVA (GHF, G20 and G77 in non-aging/aging conditions) and 3-way ANOVA (temperature x rinsing x aging factors, excluding GHF), followed by Tukey's test (p = 0.05).Results: The 2-way ANOVA revealed that the mu TBS was significantly affected by the surface treatment (p < 0.001) but not by aging (p = 0.68), and Tukey's test showed that G77-n/G77-a (18.0 MPa) > GHF-n/GHF-a (12.2 MPa) > G20-n/G20-a (9.1 MPa). The 3-way ANOVA revealed that the mu TBS was significantly affected by the heat treatment and rinsing factors (p < 0.001), but not affected by aging (p = 0.36). The rinsing procedure decreased, while oven drying increased the bond strengths. Group G77, in both non-aging and aging conditions (18.6-17.4 MPa), had the highest bond values. Failure modes were mainly mixed for all groups.Conclusion: Oven drying at 77 degrees C improved the bond strength between the resin cement and feldspathic ceramic, but hot water rinsing reduced the bond strength and should not be recommended.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pós-graduação em Odontologia Restauradora - ICT

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The objective of this study was to assess if the positioning of the impression tray could cause plaster casts distortion during gypsum setting time. fifteen pairs of master models were cast with alginate impression material and immediately poured with gypsum. impressions were allowed to set with the tray in the not inverted position (group a) or in the inverted position (group b). the plaster models were digitized using a laser scanner (3shape r-700, 3shape a/s). tooth size measurements and distances were obtained using o3d software (widialabs, brasil) measurement tools. data were analyzed by paired t test and linear regression with 5% significance. most measurements of both groups were similar, except for the lower intermolar distance. it was not possible to corroborate the presence of distortions owing to the position of the impression tray during gypsum setting time.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of this study was to evaluate the fracture resistance of simulated immature teeth after different intra-radicular treatments. Crowns and roots of bovine incisors were cut transversally and removed to simulate immature teeth. Root canal preparation and flaring were performed using a bur in crown-apex and apex-crown direction. The samples were distributed into 5 groups (n=10): Positive control (PoC) - no root canal flaring or filling; Negative control (NeC) - teeth were sectioned and their root canals were flared; Direct anatomical glass fiber post (RaP) - #2 Reforpost main glass fiber post relined with composite resin; Double tapered conical glass fiber posts (ExP) - #3 Exacto glass fiber post; and #2 Reforpost main glass fiber + Reforpin accessory glass fiber posts (RrP). In RaP, ExP and RrP, 4.0-mm apical plugs were done with MTA Angelus. The specimens were embedded in polystyrene resin inside cylinders and the periodontal ligament was simulated with a polyether-based impression material. The specimens were submitted to compressive fracture strength test (0.5 mm/min at 135° relative to the long axis of the tooth) in a servo-hydraulic mechanical testing machine MTS 810. Data were subjected to one-way ANOVA and Dunnett's C or Tukey's tests (α=0.05). The control groups (PoC and NeC) showed lower fracture strength than the experimental groups. NeC presented the lowest resistance and ExP presented the highest resistance among the experimental groups. The flaring procedures produced a detrimental effect on the fracture resistance of the bovine teeth. Glass fiber intra-radicular posts increased significantly the fracture resistance of simulated immature teeth.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objectives: The aim of this study was to investigate the internal fit (IF) of glass-infiltrated alumina (ICA - In-Ceram Alumina), yttria-stabilized tetragonal zirconia polycrystals (Y-TZP - IPS e.max ZirCAD), and metal-ceramic (MC - Ni-Cr alloy) crowns. Material and Methods: Sixty standardized resin-tooth replicas of a maxillary first molar were produced for crown placement and divided into 3 groups (n=20 each) according to the core material used (metal, ICA or Y-TZP). The IF of the crowns was measured using the replica technique, which employs a light body polyvinyl siloxane impression material to simulate the cement layer thickness. The data were analyzed according to the surfaces obtained for the occlusal space (OS), axial space (AS) and total mean (TM) using two-way ANOVA with Tukey's multiple comparison test (p<0.05). Results: No differences among the different areas were detected in the MC group. For the Y-TZP and ICA groups, AS was statistically lower than both OS and TM. No differences in AS were observed among the groups. However, OS and TM showed significantly higher values for ICA and Y-TZP groups than MC group. Comparisons of ICA and Y-TZP revealed that OS was significantly lower for Y-TZP group, whereas no differences were observed for TM. Conclusions: The total mean achieved by all groups was within the range of clinical acceptability. However, the metal-ceramic group demonstrated significantly lower values than the all-ceramic groups, especially in OS.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of this study was to compare two methods of assessing apical transportation in curved canals after rotary instrumentation, namely, cross-sections and micro-computed tomography (mu CT). Thirty mandibular molars were divided into two groups and prepared according to the requirements of each method. In G1 (cross-sections), teeth were embedded in resin blocks and sectioned at 2.0, 3.5, and 5.0 mm from the anatomic apex. Pre- and postoperative sections were photographed and analyzed. In G2 (mu CT), teeth were embedded in a rubber-base impression material and scanned before and after instrumentation. Mesiobuccal canals were instrumented with the Twisted File (TF) system (SybronEndo, Orange, USA), and mesiolingual canals, with the Endo Sequence (ES) system (Brasseler, Savannah, USA). Images were reconstructed, and sections corresponding to distances 2.0, 3.5, and 5.0 mm from the anatomic apex were selected for comparison. Data were analyzed using Mann-Whitney's test at a 5% significance level. The TF and ES instruments produced little deviation from the root canal center, with no statistical difference between them (P > 0.05). The canal transportation results were significantly lower (0.056 mm) in G2 than in G1 (0.089 mm) (p = 0.0012). The mu CT method was superior to the cross-section method, especially in view of its ability to preserve specimens and provide results that are more closely related to clinical situations.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVES: The aim of this study was to investigate the internal fit (IF) of glass-infiltrated alumina (ICA - In-Ceram Alumina), yttria-stabilized tetragonal zirconia polycrystals (Y-TZP - IPS e.max ZirCAD), and metal-ceramic (MC - Ni-Cr alloy) crowns. MATERIAL AND METHODS: Sixty standardized resin-tooth replicas of a maxillary first molar were produced for crown placement and divided into 3 groups (n=20 each) according to the core material used (metal, ICA or Y-TZP). The IF of the crowns was measured using the replica technique, which employs a light body polyvinyl siloxane impression material to simulate the cement layer thickness. The data were analyzed according to the surfaces obtained for the occlusal space (OS), axial space (AS) and total mean (TM) using two-way ANOVA with Tukey s multiple comparison test (p<0.05). RESULTS: No differences among the different areas were detected in the MC group. For the Y-TZP and ICA groups, AS was statistically lower than both OS and TM. No differences in AS were observed among the groups. However, OS and TM showed significantly higher values for ICA and Y-TZP groups than MC group. Comparisons of ICA and Y-TZP revealed that OS was significantly lower for Y-TZP group, whereas no differences were observed for TM. CONCLUSIONS: The total mean achieved by all groups was within the range of clinical acceptability. However, the metal-ceramic group demonstrated significantly lower values than the all-ceramic groups, especially in OS.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Introduction. Ectodermal Dysplasias are a heterogeneous group of inherited disorders characterized by dysplasia of tissues of ectodermal origin (hair, nails, teeth, skins and glands). Clinically, it may be divided into two broad categories: the X-linked hypoidrotic form and the hidrotic form. Hypohidrotic Ectodermal Dysplasia (H.E.D) is characterized by the triad oligo-anodontia, hypotricosis, hypo-anhydrosis (Christ-Siemens-Tourane syndrome). The incidence of HED is about 1/100,000. Mutation in the actodysplasin-A (EDA) and ectodysplasin-A receptor (EDAR) genes are responsible for X-linked and autosomal HED. The clinical features include sparse, fine hair, missing or conical-shaped teeth, decreased sweat and mucous glands, hypoplastic skin, and heat intolerance with exercise or increased ambient temperature. Complete or partial anodontia and malformation of teeth are the most frequent dental findings. Incisors and canines are often conical-shaped while primarily second molars, if present, are mostly affected by taurodontism. Treatment is supportive and includes protection from heat exposure, early prosthetic rehabilitation, skin, hair ear, nose and nail care, and genetic counseling for family planning. The diagnosis of HED in the neonatal and early infancy period may be difficult since sparse hair and absent teeth are normal finding at this age. In childhood the diagnosis is more easily made on the basis of history and clinical examination. Dental abnormalities are the most common complaint. Prosthetic rehabilitation has been recommended as an essential part of the management of HED because is important from functional, esthetic, and psychological standpoint. A team approach that includes input from a pediatric dentist, an orthodontist, a prosthodontist, and an oral and maxillofacial surgeon is necessary for a successful outcome. Conventional prosthodontic rehabilitation in young patient is often difficult because of the anatomical abnormalities of existing teeth and alveolar ridges. The conical shaped teeth and “knife-edge” alveolar ridges result in poor retention and instability of dentures. Moreover, denture must permit jaws expansion and a correct pattern of growth. Materials and Methods. Complete removable dentures were provided to allow for normal physiological development and a corrected masticatory function. Initial maxillary and mandibular impressions were made with smallest stock trays and irreversible hydrocolloid and then final impressions ware made with light-bodied polysulfide rubber base impression material. A base of autopolymerizing resin was constructed and a wax rim was added to the base. The patient’s vertical dimension of occlusion was established by assessing phonetic and esthetic criteria. Preliminary occlusal relations were recorded, and the mandibular cast was mounted on the articulator. Acrylic resin teeth specific for children dentures were selected and mounted. The dentures were tried in and, after proper adjustments, were inserted. The patients were monitored clinically every month to fit prostheses. Cephalometric radiographs were taken every 6 month with the prostheses in place in order to evaluate correct pattern of growth. Cephalometric measurements were realized and used to evaluate the effect of rehabilitation on craniofacial growth. Cephalometric measurements of sound patients were compared with ED patients. After two month expander screws (three-way screw in the upper denture and two-way the lower one)were inserted in each denture in order to permit the expansion of the denture and the jaws growth. Where conical teeth were present, composite crown were realized and luted to improve the esthetic and phonesis. In order to improve retention the placement of endosseous implants was carried out. TC 3D Accuitomo was performed and a resin model of mandibular bone of the patient was realized. At the age of 11 years two implants were inserted into anterior mandible in a child with anodontia. Despite a remarkable multi-dimensional atrophy of the mandibular alveolar process, the insertion of two tapered screw implants (SAMO Smiler, diameter 3.8, length 10 mm). After a submerged healing period of two-three month, the implants were exposed. Implants were connected with an expansion guide that permits mandibular growth and prosthetic retention. The amount of mandibular growth was also evaluate dusing the expansion guide. Results. Early oral rehabilitation improve oral function, phonesis and esthetic, reducing social impairment. Treated patients showed normal cephalometric measurement. Early rehabilitation is able to prevent the prognatissm of the mandibula . The number of teeth was significantly related to several changes in craniofacial morphology. Discussion. In the present study the 5,3% of ED patients showed hypodontia, the l’89,4% di oligodontia, and the 5,3% di anodontia. The cephalometric analysis supports that ED patients showed midface hypoplasia. ED groups showed an increased pogonion to nasion measurement than sound patients, indicative of class III tendency. The present study demonstrated that number of teeth was significantly correlated with deviation of cephalometric measurements from normality. Oligoanodontia is responsible for changing of cephalometric measuraments also on sagittal plane with a class III tendency. Maxillary jaw showed a retrused position related to the presence of hypodontia.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

AIM: The aim of this study was to assess the marginal fit of crowns on the Straumann (ITI) Dental Implant System with special consideration of different casting dental materials. MATERIAL AND METHODS: Sixty porcelain-fused-to-metal crowns were fabricated: 18 crowns on standard cone abutments with an impression cylinder, partially prefabricated analogs, no coping and screw-retained (A); 18 crowns on solid abutments without an impression device, no analogs, no coping and cemented (B); and 18 crowns on solid abutments using an impression transfer cap, an analog with a shoulder, no coping and cemented (C). In each group, six crowns were made on epoxy mastercasts (Bluestar), six on synthetic plaster (Moldasynt) and six on super hard stone (Fujirock). Six additional crowns were fabricated with the transversal screw retention system onto the Octa system with impression transfer caps, metal analogs, gold copings and screw-retained (D). Impregum was used as impression material. Crowns of B and C were cemented with KetacCem. Crowns of A and D were fixed with an occlusal screw torqued at 15 N cm. Crowns were embedded, cut and polished. Under a light microscope using a magnification of x 100, the distance between the crown margin (CM) and the shoulder (marginal gap, MG) and the distance between the CM and the end of the shoulder (crown length, CL) was measured. RESULTS: MGs were 15.4+/-13.2 microm (A), 21.2+/-23.1 microm (B), 11+/-12.1 microm (C) and 10.4+/-9.3 microm (D). No statistically significantly differences using either of the casting materials were observed. CLs were -21.3+/-24.8 microm (A), 3+/-28.9 microm (B), 0.5+/-22 microm (C) and 0.1+/-15.8 microm (D). Crowns were shorter on synthetic casting materials compared with stone casts (P<0.005). CONCLUSIONS: CMs fit precisely with both cemented and screw-retained versions as well as when using no, partial or full analogs.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Deflection of conventional and newly introduced nondeflecting dental local anesthetic needles were compared in vitro by radiographic examination of the course of the needles in a hydrocolloid impression material. Results indicated significantly less deflection of the new needles when compared to a variety of conventional needles. Controlled clinical trials will be required to test the significance of this finding.