922 resultados para Hip adduction


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective. The purpose of this series was to determine the frequency of abductor mechanism avulsion by sonography after total hip arthroplasty with the Hardinge approach (J Bone Joint Surg Br 1982; 64:17-19) and its relationship to the presence of insufficiency of this musculature in the postoperative period. Methods. Thirty-four consecutive patients were prospectively accessed in the postoperative period of hip arthroplasty by the Trendelenburg test, hip sonography, and abductor muscle electromyography. In patients who were found to have clinical insufficiency of the abductor musculature, we also measured the femoral offset in the preoperative and postoperative radiographs. Hip sonography was performed by an experienced musculoskeletal radiologist blinded to the other tests, and the tendons of the gluteus medius and gluteus minimus were visualized on longitudinal and transverse sections with a 7- to 10-MHz linear transducer. Results. Eight patients presented clinical insufficiency of the abductor musculature as detected by the Trendelenburg test. Four of these 8 patients with abductor insufficiency presented tendinous avulsion detected by sonography. One of the 4 patients with abductor insufficiency and normal sonographic findings had a decrease in the femoral offset caused by the arthroplasty itself. Two patients presented electromyographic changes of the abductor musculature, with no tendinous avulsion detected by sonography and no abductor insufficiency. Conclusions. We concluded that in patients undergoing total hip arthroplasty by the Hardinge approach in whom insufficiency of the abductor musculature develops, sonography is an interesting method of investigation because it identified the cause of this problem in most of our patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The goal of this study was to determine if increasing strength in primary knee extensors and flexors would directly affect net knee joint moments during a common functional task in persons with knee osteoarthritis. Methods: An exploratory single sample clinical trial with pre-post treatment measures was used to study volunteers with clinical diagnosis of mild knee osteoarthritis (OA) in one knee. Subjects participated in an individually supervised training program 3 times a week for eight weeks consisting of progressive resistive exercises for knee extensors and knee flexors. Pre and post training outcome assessments included: 1. Net internal knee joint moments, 2. Electromyography of primary knee extensors and flexors, and 3. Self-report measures of knee pain and function. The distribution of lower extremity joint moments as a percent of the total support moment was also investigated. Findings: Pain, symptoms, activities of daily life, quality of life, stiffness, and function scores showed significant improvement following strength training. Knee internal valgus and hip internal rotation moments showed increasing but non-statistically significant changes post-training. There were no significant differences in muscle co-contraction activation of the Quadriceps and Hamstrings. Interpretation: While exercise continues to be an important element of OA management, the results of this study suggest improvements in function, pain, and other symptoms, as a result of strength training may not be causally related to specific biomechanical changes in net joint moments. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this investigation was to assess the diagnostic accuracy of intraoperative cultures for the early identification of patients who are at risk of infection after primary total hip arthroplasty. Four or six swabs were obtained immediately before the wound closure in 263 primary total hip replacements. Patients with a maximum of one positive culture were denoted as patients with a normal profile and did not receive any treatment. Patients with two or more positive cultures, with the same organism identified, were denoted as patients with a risk profile and received treatment with a specific antibiotic as determined by the antibiogram for six weeks. The follow-up ranged from a minimum of one year to five years and eleven months, concentrating on the presence or absence of infection, which was defined as discharge of pus through the surgical wound or as a fistula at any time after surgery. The accuracy of this procedure ( number of cases correctly identified in relation to the total number of cases) in the group of 152 arthroplasties in which 4 swabs per patient were collected was 96%. In the group of 111 arthroplasties in which 6 swabs per patient were collected the accuracy was 95.5%. We conclude that the collection of swabs under the conditions described is a method of high accuracy ( above 95%) for the evaluation of risk of infection after primary total hip arthroplasty.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To determine the relationships between eccentric hip and knee torques, symptom severity and functional capacity in females with patellofemoral pain syndrome (PFPS). Design: Within-subject correlational study. Setting: University biomechanics laboratory. Participants: 10 females diagnosed with PFPS. Main outcome measures: Eccentric strength of the hip abductors and lateral rotators, and knee extensors were assessed using an isokinetic dynamometer. A 10-cm visual analog scale was used to determine usual knee pain in the last week. The Anterior Knee Pain Scale (AKPS) was used to determine the functional capacity of the patients. Results: The study found that the greater the eccentric knee extensor and hip lateral rotator torques, the higher the functional capacity of the patients (p = 0.02, r = 0.72; p = 0.02, r = 0.72). It was also shown that the greater hip lateral rotator torque, the less the usual pain reported in the last week (p = 0.004, r = -0.84). Despite the lack of statistical significance (p = 0.11), it was also found a modest negative relationship between the eccentric knee extensor torque and the usual pain reported in the last week (r = -0.56) that was considered clinically meaningful (d = 1.4). Conclusions: This study showed that eccentric knee extensor and hip lateral rotator torques were associated with functional capacity and pain level in females with PFPS. Further investigations should be carried out to verify the effects of an intervention program focused on the eccentric action of these muscles with respect to the symptoms in patients with PFPS. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objectives of this study were to evaluate the outcomes of our patients admitted with hip fractures, and to benchmark these results with other hospitals, initially in Europe and subsequently in Australia. The Standardised Audit of Hip Fractures in Europe (SAHFE) questionnaires was used as the data gathering instrument. The participants were all patients admitted to Redcliffe Hospital with a fractured neck of femur prior to surgery. This paper reports the results of the first 70 consecutive patients admitted to Redcliffe Hospital with a fractured neck of femur from November 1st 2000. The main outcome measures were mobility, independence, residence prior to fracture; type of fracture and surgical repair; and time to surgery, survival rates and discharge destination. Results: 43 patients were admitted from home, but only 13 returned home directly from the orthopaedic ward. It is hoped that most of the 26 transferred to the rehabilitation ward will ultimately return home. 7 patients died, these were aged 82 to 102, and all had premorbid disease. Delays in surgery were apparent for 13 patients, mainly due to administrative problems. Conclusions: We support the recommendation in the Fifteenth Scottish Intercollegiate Guidelines Network Publication on the management of hip fractures, that all units treating this condition should enter an audit to evaluate their management. (author abstract)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background and Purpose Previous research regarding the symmetry of trans-tibial amputees has examined weight distribution and various gait parameters between prosthetic and sound limbs. However, to date, no known research has determined if asymmetry is present in the strength of the hip abductor muscles or if correlations exist between these categories of symmetry. The purpose of the present study was, therefore, to document asymmetry present in stance, strength and gait measures, and to determine the relationship between these variables. Method Twenty-three elderly, unilateral trans-tibial amputees stood on two adjacent forceplates whilst the weight distribution and standard deviation (SD) of the anterior-posterior and the medio-lateral centre of pressure excursion (COPE) under each limb was recorded during four 40 s trials: quiet stance (QS), with eyes open and eyes closed; and even stance (ES), with eyes open and eyes closed. Gait measures (velocity, cadence, step and stride lengths, stance:swing ratio and period of double support) over 10 m of fast, yet safe walking and measures of the strength of hip abductor muscles were also obtained by use of a stride analyser and a dynamometer, respectively. Results No significant differences were found between QS and ES measures. However, significantly more weight was taken on the sound limb than on the amputated limb. Notably, more anterior-posterior movement occurred under the sound limb than the amputated limb, with this becoming more apparent with the eyes closed. Movement in the medio-lateral direction was found to be the same between sides. No differences in muscle strength or gait measures between limbs were demonstrated. However. strong hip abductor muscles were correlated with increased weight-bearing on the amputated limb, improved gait parameters and reduced medio-lateral COPE under the amputated limb. Conclusions This research confirms the asymmetrical nature of amputee stance and demonstrates symmetry of strength and gait measures between limbs. The correlations between hip abductor muscle strength, weight distribution and gait measures illustrates the importance of pre- and postoperative training of these muscles. Copyright © 2002 Whurr Publishers Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: (a) To compare the magnitude of gluteus medius and tensor fascia lata activation between a group of subjects with clinical unilateral hip osteoarthritis and a group of healthy older adults. (b) To compare the magnitude of activation of the gluteus medius and tensor fascia lata between sides in a group of subjects with clinical unilateral hip osteoarthritis and a group of healthy older adults. Methods: 19 subjects with clinical unilateral hip osteoarthritis and 19 healthy controls were investigated. The subjects performed a stepping task during which recordings were obtained using surface electromyograms from the hip abductors, and kinetic data were obtained from a dual force platform. Results: Subjects with clinical hip osteoarthritis had higher gluteus medius activation than the healthy older adults (p=0.037). In addition, there were no differences in the magnitude of gluteus medius activation between the sides (p=0.733). There was no difference in the force platform data between the groups (p=0.078). Conclusions: The increased magnitude of gluteus medius activation in the group with hip osteoarthritis is evidence of a muscular dysfunction associated with hip disease. This has implications for the progressive nature of the disease and for its conservative management.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This is the first report of surface-active phospholipid as the boundary lubricant in total hip arthroplasty. Aspirate and rinsings from the bearing surfaces of 25 revision operations and one primary surgery were analyzed from 3 weeks to 26 years postoperatively. All samples contained substantial amounts of surface-active phospholipids ranging from 14 to 4186 μg. These findings indicate that synoviocytes continue producing the lubricant in significant quantities after arthroplasty surgery independent of the type of joint replacement and its fixation. Surface-active phospholipid was found on all bearing surfaces analyzed including polyethylene, stainless steel, chrome cobalt, alumina, zirconia, and titanium.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background and aims: Hip fracture is a devastating event in terms of outcome in the elderly, and the best predictor of hip fracture risk is hip bone density, usually measured by dual X-ray absorptiometry (DXA). However, bone density can also be ascertained from computerized tomography (CT) scans, and mid-thigh scans are frequently employed to assess the muscle and fat composition of the lower limb. Therefore, we examined if it was possible to predict hip bone density using mid-femoral bone density. Methods: Subjects were 803 ambulatory white and black women and men, aged 70-79 years, participating in the Health, Aging and Body Composition (Health ABC) Study. Bone mineral content (BMC, g) and volumetric bone mineral density (vBMD, mg/cm(3)) of the mid-femur were obtained by CT, whereas BMC and areal bone mineral density (aBMD, g/cm(2)) of the hip (femoral neck and trochanter) were derived from DXA. Results: In regression analyses stratified by race and sex, the coefficient of determination was low with mid-femoral BMC, explaining 6-27% of the variance in hip BMC, with a standard error of estimate (SEE) ranging from 16 to 22% of the mean. For mid-femur vBMD, the variance explained in hip aBMD was 2-17% with a SEE ranging from 15 to 18%. Adjusting aBMD to approximate volumetric density did not improve the relationships. In addition, the utility of fracture prediction was examined. Forty-eight subjects had one or more fractures (various sites) during a mean follow-up of 4.07 years. In logistic regression analysis, there was no association between mid-femoral vBMD and fracture (all fractures), whereas a 1 SD increase in hip BMD was associated with reduced odds for fracture of similar to60%. Conclusions: These results do not support the use of CT-derived mid-femoral vBMD or BMC to predict DXA-measured hip bone mineral status, irrespective of race or sex in older adults. Further, in contrast to femoral neck and trochanter BMD, mid-femur vBMD was not able to predict fracture (all fractures). (C) 2003, Editrice Kurtis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O trabalho analisa a potencialidade do desenvolvimento de alian??as entre o p??blico e o privado na gest??o p??blica municipal brasileira da sa??de. A relev??ncia da quest??o pauta-se na transfer??ncia de responsabilidade da presta????o de servi??os de sa??de para os munic??pios, posterior ?? promulga????o da Constitui????o Federal, aliada ?? limita????o da capacidade de gest??o dos mesmos. As an??lises aqui tratadas referem-se ??s alian??as previstas no arcabou??o legal brasileiro, estabelecidas entre o ente p??blico e o terceiro setor. Essas alian??as s??o introduzidas pela reforma do aparelho do Estado, em 1995, no ??mbito da qual se utilizou a estrat??gia de publiciza????o que tratou do fortalecimento dessa alian??a entre o Estado e o Terceiro Setor. A partir dos modelos poss??veis de parcerias com o terceiro setor, este estudo apresenta uma an??lise do modelo das organiza????es sociais (OS), trazendo ?? luz estrat??gias e desafios para sua implementa????o.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A presente tese de doutoramento em Educação aborda a cultura do Hip Hop e sua relação com o contexto educativo. Insere-se nas discussões da linha de pesquisa em Educação e Linguagens e problematiza o espaço escolar, enquanto espaço de reprodução da ideologia hegemônica, analisando o projeto “Escola de Rimas”, desenvolvido na Grande Vitória, como movimento de resistência e ressignificação cultural na escola. Parte da pergunta: Como as práticas discursivas do Hip Hop podem ressignificar o contexto escolar? A presente tese aborda a cultura do Hip Hop como campo discursivo singular de uma experiência narrativa (BENJAMIN, 1986; BONDÍA, 2001) e de uma subjetividade eticamente responsável (BAKHTIN, 1992a; 1992b; 2010), fundada no princípio da alteridade (PONZIO, 2009), e o analisa a partir de uma perspectiva crítica e dialógica (FREIRE, 1981; 1994; 1995; GIROUX, 1986; 1987; BRANDÃO, 1986; BAKHTIN, 1992a; 1992b; 2010). Desenvolve a pesquisa em um contexto limiar entre a escola e a cultura hip hop e dimensiona o debate das culturas marginais nos contextos educativos, voltando-se para os sujeitos e suas experiências narrativas, avaliando a interação de algumas de suas práticas discursivas com o processo de ensino-aprendizagem. Para isso, analisa o projeto cultural “Escola de Rimas”, criado pelos próprios ativistas do movimento hip hop da Grande Vitória e desenvolvido em uma escola da rede pública estadual de ensino do Espírito Santo, com o objetivo de discutir o seu papel em um processo de ressignificação educacional. Como hipótese de trabalho defende-se que o espaço escolar, como espaço de disputas, é ressignificado com a introdução de outras práticas discursivas e culturais, entre elas o hip hop, que aponta para a necessidade de ouvir responsiva e responsavelmente as narrativas dos educandos, contribuindo, assim, para a formação crítica desses sujeitos e enfrentando, ao mesmo tempo, práticas de exclusão historicamente instituídas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The success of artificial prosthetic replacements depends on the fixation of the artificial prosthetic component after being implanted in the thighbone. The materials for fixation are subject to mechanical stresses, which originate permanent deformations, incipient cracks and even fatigue fractures. This work shows the possibility of monitoring the mechanical stress over time in prosthesis. In this way, highly sensitive silicon thin-film piezoresistive sensors were developed attached to prosthesis and their results compared with commercial strain gauge sensors. Mechanical stress-strain experiments were performed in compressive mode, during 10,000 cycles. Experimental data was acquired at mechanical vibration frequencies of 0.5 Hz, 1 Hz and 5 Hz, and sent to a computer by means of a wireless link. The results show that there is a decrease in sensitivity of the thin-film silicon piezoresistive sensors when they are attached to the prosthesis, but this decrease does not compromise its monitoring performance. The sensitivity, compared to that of commercial strain gauges, is much larger due to their higher gauge factors (-23.5), when compared to the GFs of commercial sensors (2).