978 resultados para Gas Chromatography coupled with Nitrogen-Phosphorus Detector
Resumo:
This work describes the construction and testing of a simple pressurized solvent extraction (PSE) system. A mixture of acetone:water (80:20), 80 ºC and 103.5 bar, was used to extract two herbicides (Diuron and Bromacil) from a sample of polluted soil, followed by identification and quantification by high-performance liquid chromatography coupled with diode array detector (HPLC-DAD). The system was also used to extract soybean oil (70 ºC and 69 bar) using pentane. The extracted oil was weighed and characterized through the fatty acid methyl ester analysis (myristic (< 0.3%), palmitic (16.3%), stearic (2.8%), oleic (24.5%), linoleic (46.3%), linolenic (9.6%), araquidic (0.3%), gadoleic (< 0.3%), and behenic (0.3%) acids) using high-resolution gas chromatography with flame ionization detection (HRGC-FID). PSE results were compared with those obtained using classical procedures: Soxhlet extraction for the soybean oil and solid-liquid extraction followed by solid-phase extraction (SLE-SPE) for the herbicides. The results showed: 21.25 ± 0.36% (m/m) of oil in the soybeans using the PSE system and 21.55 ± 0.65% (m/m) using the soxhlet extraction system; extraction efficiency (recovery) of herbicides Diuron and Bromacil of 88.7 ± 4.5% and 106.6 ± 8.1%, respectively, using the PSE system, and 96.8 ± 1.0% and 94.2 ± 3.9%, respectively, with the SLP-SPE system; limit of detection (LOD) and limit of quantification (LOQ) for Diuron of 0.012 mg kg-1 and 0.040 mg kg-1, respectively; LOD and LOQ for Bromacil of 0.025 mg kg-1 and 0.083 mg kg-1, respectively. The linearity used ranged from 0.04 to 1.50 mg L-1 for Diuron and from 0.08 to 1.50 mg L-1 for Bromacil. In conclusion, using the PSE system, due to high pressure and temperature, it is possible to make efficient, fast extractions with reduced solvent consumption in an inert atmosphere, which prevents sample and analyte decomposition.
Resumo:
Dissertação apresentada para obtenção do Grau de Doutor em Ciências do Ambiente pela Universidade Nova de Lisboa, Faculdade de Ciências e Tecn
Resumo:
Dissertação para obtenção do Grau de Mestre em Engenharia Química e Bioquímica
Resumo:
Dissertação de mestrado integrado em Engenharia de Materiais
Resumo:
The quantitative chemical analysis of the Brazilian sugar cane spirit distilled from glass column packaged with copper, stainless steel, aluminum sponge, or porcelain balls is described. The main chemical compounds determined by gas chromatography coupled with flame ionization (FID) and flame photometric (FPD) detectors and liquid chromatography coupled with diode array detector are aldehydes, ketones, carboxylic acids, alcohols, esters and dimethylsulfite (DMS). The spirits produced either in columns filled with copper or aluminum pot still exhibits the lowest DMS contents but the higher sulfate and methanol contents, whereas spirits produced in stainless steel or porcelain showed higher DMS concentration and lower teors of sulfate ion and methanol. These observations are coherent with DMS oxidation to sulfate, with methanol as by product, in the presence of either copper or aluminum.
Resumo:
Il est reconnu que le benzène, le toluène, l’éthylbenzène et les isomères du xylène, composés organiques volatils (COVs) communément désignés BTEX, produisent des effets nocifs sur la santé humaine et sur les végétaux dépendamment de la durée et des niveaux d’exposition. Le benzène en particulier est classé cancérogène et une exposition à des concentrations supérieures à 64 g/m3 de benzène peut être fatale en 5–10 minutes. Par conséquent, la mesure en temps réel des BTEX dans l’air ambiant est essentielle pour détecter rapidement un danger associé à leur émission dans l’air et pour estimer les risques potentiels pour les êtres vivants et pour l’environnement. Dans cette thèse, une méthode d’analyse en temps réel des BTEX dans l’air ambiant a été développée et validée. La méthode est basée sur la technique d’échantillonnage direct de l’air couplée avec la spectrométrie de masse en tandem utilisant une source d’ionisation chimique à pression atmosphérique (APCI-MS/MS directe). La validation analytique a démontré la sensibilité (limite de détection LDM 1–2 μg/m3), la précision (coefficient de variation CV < 10%), l’exactitude (exactitude > 95%) et la sélectivité de la méthode. Des échantillons d’air ambiant provenant d’un site d’enfouissement de déchets industriels et de divers garages d’entretien automobile ont été analysés par la méthode développée. La comparaison des résultats avec ceux obtenus par la technique de chromatographie gazeuse on-line couplée avec un détecteur à ionisation de flamme (GC-FID) a donné des résultats similaires. La capacité de la méthode pour l’évaluation rapide des risques potentiels associés à une exposition aux BTEX a été prouvée à travers une étude de terrain avec analyse de risque pour la santé des travailleurs dans trois garages d’entretien automobile et par des expériences sous atmosphères simulées. Les concentrations mesurées dans l’air ambiant des garages étaient de 8,9–25 µg/m3 pour le benzène, 119–1156 µg/m3 pour le toluène, 9–70 µg/m3 pour l’éthylbenzène et 45–347 µg/m3 pour les xylènes. Une dose quotidienne environnementale totale entre 1,46 10-3 et 2,52 10-3 mg/kg/jour a été déterminée pour le benzène. Le risque de cancer lié à l’exposition environnementale totale au benzène estimé pour les travailleurs étudiés se situait entre 1,1 10-5 et 1,8 10-5. Une nouvelle méthode APCI-MS/MS a été également développée et validée pour l’analyse directe de l’octaméthylcyclotétrasiloxane (D4) et le décaméthylcyclopentasiloxane (D5) dans l’air et les biogaz. Le D4 et le D5 sont des siloxanes cycliques volatils largement utilisés comme solvants dans les processus industriels et les produits de consommation à la place des COVs précurseurs d’ozone troposphérique tels que les BTEX. Leur présence ubiquitaire dans les échantillons d’air ambiant, due à l’utilisation massive, suscite un besoin d’études de toxicité. De telles études requièrent des analyses qualitatives et quantitatives de traces de ces composés. Par ailleurs, la présence de traces de ces substances dans un biogaz entrave son utilisation comme source d’énergie renouvelable en causant des dommages coûteux à l’équipement. L’analyse des siloxanes dans un biogaz s’avère donc essentielle pour déterminer si le biogaz nécessite une purification avant son utilisation pour la production d’énergie. La méthode développée dans cette étude possède une bonne sensibilité (LDM 4–6 μg/m3), une bonne précision (CV < 10%), une bonne exactitude (> 93%) et une grande sélectivité. Il a été également démontré qu’en utilisant cette méthode avec l’hexaméthyl-d18-disiloxane comme étalon interne, la détection et la quantification du D4 et du D5 dans des échantillons réels de biogaz peuvent être accomplies avec une meilleure sensibilité (LDM ~ 2 μg/m3), une grande précision (CV < 5%) et une grande exactitude (> 97%). Une variété d’échantillons de biogaz prélevés au site d’enfouissement sanitaire du Complexe Environnemental de Saint-Michel à Montréal a été analysée avec succès par cette nouvelle méthode. Les concentrations mesurées étaient de 131–1275 µg/m3 pour le D4 et 250–6226 µg/m3 pour le D5. Ces résultats représentent les premières données rapportées dans la littérature sur la concentration des siloxanes D4 et D5 dans les biogaz d’enfouissement en fonction de l’âge des déchets.
Resumo:
Background and Aims Despite recent recognition that (1) plant–herbivore interactions during the establishment phase, (2) ontogenetic shifts in resource allocation and (3) herbivore response to plant volatile release are each pivotal to a comprehensive understanding of plant defence, no study has examined how herbivore olfactory response varies during seedling ontogeny. Methods Using a Y-tube olfactometer we examined snail (Helix aspersa) olfactory response to pellets derived from macerated Plantago lanceolata plants harvested at 1, 2, 3, 4, 5, 6 and 8 weeks of age to test the hypothesis that olfactory selection of plants by a generalist herbivore varies with plant age. Plant volatiles were collected for 10 min using solid-phase microextraction technique on 1- and 8-week-old P. lanceolata pellets and analysed by gas chromatography coupled with a mass spectrometer. Key Results Selection of P. lanceolata was strongly negatively correlated with increasing age; pellets derived from 1-week-old seedlings were three times more likely to be selected as those from 8-week-old plants. Comparison of plant selection experiments with plant volatile profiles from GC/MS suggests that patterns of olfactory selection may be linked to ontogenetic shifts in concentrations of green leaf volatiles and ethanol (and its hydrolysis derivatives). Conclusions Although confirmatory of predictions made by contemporary plant defence theory, this is the first study to elucidate a link between seedling age and olfactory selection by herbivores. As a consequence, this study provides a new perspective on the ontogenetic expression of seedling defence, and the role of seedling herbivores, particularly terrestrial molluscs, as selective agents in temperate plant communities.
Resumo:
A method for the determination of volatile organic compounds (VOCs) in recycled polyethylene terephthalate and high-density polyethylene using headspace sampling by solid-phase microextraction and gas chromatography coupled to mass spectrometry detection is presented. This method was used to evaluate the efficiency of cleaning processes for VOC removal from recycled PET. In addition, the method was also employed to evaluate the level of VOC contamination in multilayer packaging material containing recycled HDPE material. The optimisation of the extraction procedure for volatile compounds was performed and the best extraction conditions were found using a 75 mu m carboxen-polydimethylsiloxane (CAR-PDMS) fibre for 20 min at 60 degrees C. The validation parameters for the established method were linear range, linearity, sensitivity, precision (repeatability), accuracy (recovery) and detection and quantification limits. The results indicated that the method could easily be used in quality control for the production of recycled PET and HDPE. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
The influence of the sample matrix in the CC-electron-capture detection analysis of the pesticides dimethoate, diazinon, chlorothalonil.. parathion methyl and fenitrothion in fruits samples has been studied. Experiments have been carried out where the pesticide responses in standard solutions prepared in selected solvent were compared with their response when present in apple, mango, papaya, banana, pineapple and melon extracts. The presence of matrix effects (MEs) and their extent were shown to be simultaneously influenced by several factors (matrix concentration, matrix type, pesticide concentration, analytical range). Pronounced MEs were observed particularly for dimethoate and diazinon in all matrices tested; in lower concentrations, all pesticides presented significant ME. The other pesticides presented variable ME. Higher ME enhancement was detected at lower pesticide concentration levels of and/or at higher matrix concentration solutions. The ME detected for fenitrothion, in the analytical range evaluated, were dependent on matrix type. For each pesticide, solvent and matrix-matched calibrations were compared for all fruit samples, and it could be concluded that quantitation based on standard solutions prepared in blank matrix extract (matrix-matched calibration) should be used to compensate the MEs and to obtain more accurate results for the pesticides studied.
Resumo:
Recently, ethyl carbamate (EC) was reclassified by the International Agency for Research on Cancer (IARC) as "probably carcinogenic to humans" and occurs mainly in fermented beverages. Nowadays many countries have set limit values for EC in alcoholic beverages. In this sense and taking into account the low concentrations found in alcoholic beverages, the scientific community has shown interest for the development of new analytical methods, whereby its simplification plays an important role in the EC control and prevention. Firstly, a simple, rapid and sensitive methodology was developed for the EC quantification in fortified wines by microextraction by packed sorbent (MEPS) with gas chromatography coupled with a mass spectrometer detector (GC-MS). This method showed good linearity (R2 = 0.999) and sensitivity (LOD = 1.5 μg/L). The accuracy of the method was assessed by means of repeatability and reproducibility (RSD < 7%). Moreover, a good recovery has been demonstrated (97 – 106%) as well as its applicability (16 fortified wines). Thus, the developed methodology has proven to be an excellent approach for routine quantification of EC in fortified wines. The EC evolution was also evaluated during a year and half of Madeira wine ageing submitted to two traditional ageing methods, estufagem and canteiro, in order to evaluate the formation kinetic. The results revealed that estufagem process increased the formation kinetic and promoted a linear increase of the EC concentration (R2 ≥ 0.977), proportionally to the ageing time (4 months). However, when the wines are firstly submitted to estufagem and then undergo canteiro ageing, the EC values remain almost constant during the following 14 months. The results suggest that estufagem does not seem to be the critical factor in the EC formation, but instead the amount of precursors in the medium.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
This paper reports the separation of the indole alkaloids from the benzene extract of the root barks of Tabernaemontana hilariana (Apocynaceae). The crude alkaloid fraction was fractionated by droplet counter-current chromatography using a low polarity mixture (hexane:ethyl acetate:ethanol:water). Nine indole alkaloids (3-hydroxycoronaridine, coronaridine, voacangine, 3-(2-oxopropyl) coronaridine, voacangine hydroxyindolenine, ibogamine, voacangine pseudoindoxyl, coronaridine pseudoindoxyl and tabernanthine) were identified using thin laver chromatography gas chromatography coupled with mass spectrometry and nuclear magnetic resonance spectroscopy. Copyright (C) 1999 John Wiley & Sons, Ltd.
Resumo:
Two highly sensitive and selective methods based on gas chromatography coupled to mass spectrometry (GC-MS) in the selected ion monitoring (SIM) mode have been developed for the quantification of 2,6-dichlorophenol (2,6-DCP), a sex pheromone of the tick females of Anocentor nitens. Standard addition method and calibration curve techniques using 5-bromine-4-hydroxy-3- methoxybenzaldehyde (5-BrV) as internal standard (IS) afforded detection limit of 0.1ngml-1. The calibration curve was linear over the concentration range from 0.5 to 500ngml-1 for 2,6-DCP. Results show that the concentration range of sex pheromone in the extracts samples was 1.08-10.35ngml-1. The methods developed provided reliable procedures to determine amounts of 2,6-DCP present in ticks. © 2003 Elsevier B.V. All rights reserved.
Resumo:
The internal combustion (IC) engines exploits only about 30% of the chemical energy ejected through combustion, whereas the remaining part is rejected by means of cooling system and exhausted gas. Nowadays, a major global concern is finding sustainable solutions for better fuel economy which in turn results in a decrease of carbon dioxide (CO2) emissions. The Waste Heat Recovery (WHR) is one of the most promising techniques to increase the overall efficiency of a vehicle system, allowing the recovery of the heat rejected by the exhaust and cooling systems. In this context, Organic Rankine Cycles (ORCs) are widely recognized as a potential technology to exploit the heat rejected by engines to produce electricity. The aim of the present paper is to investigate a WHR system, designed to collect both coolant and exhausted gas heats, coupled with an ORC cycle for vehicle applications. In particular, a coolant heat exchanger (CLT) allows the heat exchange between the water coolant and the ORC working fluid, whereas the exhausted gas heat is recovered by using a secondary circuit with diathermic oil. By using an in-house numerical model, a wide range of working conditions and ORC design parameters are investigated. In particular, the analyses are focused on the regenerator location inside the ORC circuits. Five organic fluids, working in both subcritical and supercritical conditions, have been selected in order to detect the most suitable configuration in terms of energy and exergy efficiencies.
Resumo:
OBJECTIVE: Many business organizations in Brazil have adopted drug testing programs in the workplace since 1992. Rehabilitation, rather than layoff and disciplinary measures, has been offered as part of the Brazilian employee assistance programs. The purpose study is to profile drug abuse among company workers of different Brazilian geographical regions. METHODS: Urine samples of 12,700 workers from five geographical regions were tested for the most common illicit drugs of abuse in the country: marijuana, cocaine, and amphetamine. Enzyme multiplied immunoassay technique (EMIT) and gas chromatography coupled with mass spectrometry (GC/MS) were the techniques utilized for urine testing. The distribution of collected urine samples according to geographical regions was: 72.0% southeast, 13.8% northeast, 7.9% south, 5.7% central west and 0.6% north. RESULTS: Of all samples analyzed, 1.8% was found to be positive for drugs: 0.5% from the south region, 1.1% from northeast, 1.2% from central west, 1.3% from north, and 2.2% from southeast. Of these, 59.9% was marijuana, 17.7% cocaine, 14.6% amphetamine, and 7.7% associated drugs. CONCLUSIONS: The distribution of drugs found in the samples shows a regional variation. Marijuana, however, was found in all regions. Cocaine was seen only in central west and southeast regions. Amphetamine was found in northeast, central west, and southeast regions.