1000 resultados para Estenosis de la válvula aórtica


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dilatation of the ascending aorta (AAD) is a prevalent aortopathy that occurs frequently associated with bicuspid aortic valve (BAV), the most common human congenital cardiac malformation. The molecular mechanisms leading to AAD associated with BAV are still poorly understood. The search for differentially expressed genes in diseased tissue by quantitative real-time PCR (qPCR) is an invaluable tool to fill this gap. However, studies dedicated to identify reference genes necessary for normalization of mRNA expression in aortic tissue are scarce. In this report, we evaluate the qPCR expression of six candidate reference genes in tissue from the ascending aorta of 52 patients with a variety of clinical and demographic characteristics, normal and dilated aortas, and different morphologies of the aortic valve (normal aorta and normal valve n = 30; dilated aorta and normal valve n = 10; normal aorta and BAV n = 4; dilated aorta and BAV n = 8). The expression stability of the candidate reference genes was determined with three statistical algorithms, GeNorm, NormFinder and Bestkeeper. The expression analyses showed that the most stable genes for the three algorithms employed were CDKN1β, POLR2A and CASC3, independently of the structure of the aorta and the valve morphology. In conclusion, we propose the use of these three genes as reference genes for mRNA expression analysis in human ascending aorta. However, we suggest searching for specific reference genes when conducting qPCR experiments with new cohort of samples.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introducción y objetivos: La endocarditis infecciosa (EI) es una enfermedad grave producida por diversos gérmenes que afectan las válvulas cardiacas y el tejido endomiocárdico. El objetivo fue describir las características epidemiológicas, clínicas, ecocardiográficas y microbiológicas de la endocarditis infecciosa por Staphylococcus aureus (S. aureus) meticilino sensible y resistente de la Fundación Cardioinfantil – Instituto de Cardiología (FCI-IC) en el periodo de tiempo 2010- 2015. Métodos: Cohorte retrospectiva de casos de EI por S. aureus en la FCIIC para el período 2010-2015. Se realizó descripción de las variables generales de la población a estudio utilizando medidas de tendencia central y dispersión. Análisis de desenlaces teniendo cuenta la concentración inhibitoria mínima de vancomicina. Resultados: En el estudio se presentaron 27 casos de EI, con una mayor proporción de pacientes de sexo masculino, con hipertensión, diabetes y hemodiálisis. La fiebre fue la manifestación más frecuente seguida de fenómenos vasculares. La válvula más comprometida fue la mitral, principalmente nativa. Discusión: La presentación clínica de los pacientes con EI por S. aureus es aguda por lo que la fiebre es la principal manifestación clínica presentada, lo anterior favorece un rápido diagnóstico clínico. De las cepas de S. aureus causante de EI no se encontró gérmenes con sensibilidad intermedia ni resistente a la vancomicina según criterios establecidos por CLSI. Se encontró mayor proporción de pacientes con un valor de CMI para vancomicina mayor a 0,5μg/ml lo cual es importante dado que podemos estar enfrentándonos a cepas hetero VISA (hVISA).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

En el presente trabajo se desarrolla una metodología para llevar a cabo el análisis dinámico de una válvula cardíaca artificial en condiciones de flujo no estacionario, usando un programa de computación de aplicaciones generales basado en el Método de los Volúmenes Finitos. Dicha metodología comprende el establecimiento e implementación computacional de un modelo que representa el movimiento de la válvula (posición, velocidad y aceleración angular) como el resultado de la acción de fuerzas debidas a la presión y a los esfuerzos cortantes del fluido, tomando en cuenta la inercia de la prótesis, así como el establecimiento e imposición como condición de contorno de una función de presión en la entrada del conducto. Con la finalidad de implementar la metodología desarrollada se realiza un estudio preliminar para seleccionar la malla más adecuada, determinar el tamaño óptimo del paso en el tiempo y el mínimo número de iteracciones a utilizar. Posteriormente, se resuelve el flujo laminar, incomprensible y newtoniano a través de una válvula de doble hoja en posición aórtica, y se realiza un estudio paramétrico para analizar la influencia del cambio de diversos párametros inherentes a la prótesis sobre su desempeño.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Esta tesis doctoral está encuadrada dentro del marco general de la ingeniería biomédica aplicada al tratamiento de las enfermedades cardiovasculares, enfermedades que provocan alrededor de 1.9 millones (40%) de muertes al año en la Unión Europea. En este contexto surge el proyecto europeo SCATh-Smart Catheterization, cuyo objetivo principal es mejorar los procedimientos de cateterismo aórtico introduciendo nuevas tecnologías de planificación y navegación quirúrgica y minimizando el uso de fluoroscopía. En particular, esta tesis aborda el modelado y diagnóstico de aneurismas aórticos abdominales (AAA) y del trombo intraluminal (TIL), allí donde esté presente, así como la segmentación de estas estructuras en imágenes preoperatorias de RM. Los modelos físicos específicos del paciente, construidos a partir de imágenes médicas preoperatorias, tienen múltiples usos, que van desde la evaluación preoperatoria de estructuras anatómicas a la planificación quirúrgica para el guiado de catéteres. En el diagnóstico y tratamiento de AAA, los modelos físicos son útiles a la hora de evaluar diversas variables biomecánicas y fisiológicas de las estructuras vasculares. Existen múltiples técnicas que requieren de la generación de modelos físicos que representen la anatomía vascular. Una de las principales aplicaciones de los modelos físicos es el análisis de elementos finitos (FE). Las simulaciones de FE para AAA pueden ser específicas para el paciente y permiten modelar estados de estrés complejos, incluyendo los efectos provocados por el TIL. La aplicación de métodos numéricos de análisis tiene como requisito previo la generación de una malla computacional que representa la geometría de interés mediante un conjunto de elementos poliédricos, siendo los hexaédricos los que presentan mejores resultados. En las estructuras vasculares, generar mallas hexaédricas es un proceso especialmente exigente debido a la compleja anatomía 3D ramificada. La mayoría de los AAA se encuentran situados en la bifurcación de la arteria aorta en las arterias iliacas y es necesario modelar de manera fiel dicha bifurcación. En el caso de que la sangre se estanque en el aneurisma provocando un TIL, éste forma una estructura adyacente a la pared aórtica. De este modo, el contorno externo del TIL es el mismo que el contorno interno de la pared, por lo que las mallas resultantes deben reflejar esta particularidad, lo que se denomina como "mallas conformadas". El fin último de este trabajo es modelar las estructuras vasculares de modo que proporcionen nuevas herramientas para un mejor diagnóstico clínico, facilitando medidas de riesgo de rotura de la arteria, presión sistólica o diastólica, etc. Por tanto, el primer objetivo de esta tesis es diseñar un método novedoso y robusto para generar mallas hexaédricas tanto de la pared aórtica como del trombo. Para la identificación de estas estructuras se utilizan imágenes de resonancia magnética (RM). Deben mantenerse sus propiedades de adyacencia utilizando elementos de alta calidad, prestando especial atención al modelado de la bifurcación y a que sean adecuadas para el análisis de FE. El método tiene en cuenta la evolución de la línea central del vaso en el espacio tridimensional y genera la malla directamente a partir de las imágenes segmentadas, sin necesidad de reconstruir superficies triangulares. Con el fin de reducir la intervención del usuario en el proceso de generación de las mallas, es también objetivo de esta tesis desarrollar un método de segmentación semiautomática de las distintas estructuras de interés. Las principales contribuciones de esta tesis doctoral son: 1. El diseño, implementación y evaluación de un algoritmo de generación de mallas hexaédricas conformadas de la pared y el TIL a partir de los contornos segmentados en imágenes de RM. Se ha llevado a cabo una evaluación de calidad que determine su aplicabilidad a métodos de FE. Los resultados demuestran que el algoritmo desarrollado genera mallas conformadas de alta calidad incluso en la región de la bifurcación, que son adecuadas para su uso en métodos de análisis de FE. 2. El diseño, implementación y evaluación de un método de segmentación automático de las estructuras de interés. La luz arterial se segmenta de manera semiautomática utilizando un software disponible a partir de imágenes de RM con contraste. Los resultados de este proceso sirven de inicialización para la segmentación automática de las caras interna y externa de la pared aórtica utilizando métodos basado en modelos de textura y forma a partir de imágenes de RM sin contraste. Los resultados demuestran que el algoritmo desarrollado proporciona segmentaciones fieles de las distintas estructuras de interés. En conclusión, el trabajo realizado en esta tesis doctoral corrobora las hipótesis de investigación postuladas, y pretende servir como aportación para futuros avances en la generación de modelos físicos de geometrías biológicas. ABSTRACT The frame of this PhD Thesis is the biomedical engineering applied to the treatment of cardiovascular diseases, which cause around 1.9 million deaths per year in the European Union and suppose about 40% of deaths per year. In this context appears the European project SCATh-Smart Catheterization. The main objective of this project is creating a platform which improves the navigation of catheters in aortic catheterization minimizing the use of fluoroscopy. In the framework of this project, the specific field of this PhD Thesis is the diagnosis and modeling of abdominal aortic aneurysm (AAAs) and the intraluminal thrombus (ILT) whenever it is present. Patient-specific physical models built from preoperative imaging are becoming increasingly important in the area of minimally invasive surgery. These models can be employed for different purposes, such as the preoperatory evaluation of anatomic structures or the surgical planning for catheter guidance. In the specific case of AAA diagnosis and treatment, physical models are especially useful for evaluating pressures over vascular structures. There are multiple techniques that require the generation of physical models which represent the target anatomy. Finite element (FE) analysis is one the principal applications for physical models. FE simulations for AAA may be patient-specific and allow modeling biomechanical and physiological variables including those produced by ILT, and also the segmentation of those anatomical structures in preoperative MR images. Applying numeric methods requires the generation of a proper computational mesh. These meshes represent the patient anatomy using a set of polyhedral elements, with hexahedral elements providing better results. In the specific case of vascular structures, generating hexahedral meshes is a challenging task due to the complex 3D branching anatomy. Each patient’s aneurysm is unique, characterized by its location and shape, and must be accurately represented for subsequent analyses to be meaningful. Most AAAs are located in the region where the aorta bifurcates into the iliac arteries and it is necessary to model this bifurcation precisely and reliably. If blood stagnates in the aneurysm and forms an ILT, it exists as a conforming structure with the aortic wall, i.e. the ILT’s outer contour is the same as the wall’s inner contour. Therefore, resulting meshes must also be conforming. The main objective of this PhD Thesis is designing a novel and robust method for generating conforming hexahedral meshes for the aortic wall and the thrombus. These meshes are built using largely high-quality elements, especially at the bifurcation, that are suitable for FE analysis of tissue stresses. The method accounts for the evolution of the vessel’s centerline which may develop outside a single plane, and generates the mesh directly from segmented images without the requirement to reconstruct triangular surfaces. In order to reduce the user intervention in the mesh generation process is also a goal of this PhD. Thesis to develop a semiautomatic segmentation method for the structures of interest. The segmentation is performed from magnetic resonance image (MRI) sequences that have tuned to provide high contrast for the arterial tissue against the surrounding soft tissue, so that we determine the required information reliably. The main contributions of this PhD Thesis are: 1. The design, implementation and evaluation of an algorithm for generating hexahedral conforming meshes of the arterial wall and the ILT from the segmented contours. A quality inspection has been applied to the meshes in order to determine their suitability for FE methods. Results show that the developed algorithm generates high quality conforming hexahedral meshes even at the bifurcation region. Thus, these meshes are suitable for FE analysis. 2. The design, implementation and evaluation of a semiautomatic segmentation method for the structures of interest. The lumen is segmented in a semiautomatic way from contrast filled MRI using an available software. The results obtained from this process are used to initialize the automatic segmentation of the internal and external faces of the aortic wall. These segmentations are performed by methods based on texture and shape models from MRI with no contrast. The results show that the algorithm provides faithful segmentations of the structures of interest requiring minimal user intervention. In conclusion, the work undertaken in this PhD. Thesis verifies the investigation hypotheses. It intends to serve as basis for future physical model generation of proper biological anatomies used by numerical methods.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Se describe el desarrollo poblacional promastigótico de Leishmania pifanoi en Lutzomyia youngi experimentalmente infectada y mantenida con sacarosa al 50% bajo condiciones constantes de temperatura y humedad. Se reconocen dos etapas para la diferenciación y el crecimiento de los parásitos entre las dos y ciento veinte horas postprandiales. Hasta 48 horas tiene lugar la diferenciación pleomórfica de amastigotos en promastigotos cortos, que se multiplican por división binaria hasta las 60 horas, cuando ocurre la ruptura de la membrana peritrófica. La segunda etapa tiene lugar entre las 72 y 96 horas cuando algunos parásitos migran hacia la válvula esofágica y los demás parásitos libres son excretados en gotitas fecales como promastigotos grandes y activos. Las primeras gotitas excretadas dan reacción positiva a glucosa o contienen cristales de urato. El exceso de promastigotos de la segunda fase de desarrollo es eliminado en las últimas excretas que dan reacción positiva con las pruebas Hemoscreen y Biuret para proteínas totales y también para glucosa, y constituyen el 82% del total de gotas excretadas. La excreción de parásitos por Lu. youngi es fase normal del desarrollo de L. pifanoi en un vector.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A 66-year-old female with Streptococcus viridans aortic and tricuspid infective endocarditis develops, during the course of antibiotic therapy, rupture of a right coronary sinus of Valsalva aneurysm to the right ventricle. An urgent cardiac surgery is preformed with implantation of a mechanical aortic prosthesis and a right coronary sinus plasty. Six months later a huge aortic pseudoaneurysm is diagnosed and she is submitted to a second uneventful surgery. A review is done for the significant features with discussion of diagnosis and therapy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Ross procedure has been used in children and young adults for aortic valve replacement and the correction of complex obstruction syndromes of the left ventricular outflow tract. We report the mid-term results of the Ross procedure in a single institution and performed by the same surgical team. Population: Between March 1999 and December 2005, 18 patients were operated on using the Ross procedure. The mean age at the time of surgery was 12 years, being 12 patients male (67%). The primary indication for surgery was isolated aortic valve disease, being the predominant abnormality in 58% of cases aortic regurgitation and in 42% left ventricular outflow tract obstruction. Associated lesions included sub-aortic membrane in 3 patients (16%), small VSD in 2 patients (11%), bicuspid aortic valve in 4 patients (22%) and severe left ventricular dysfunction and mitral valve regurgitation in 1 patient (6%). Ten of the 18 patients (56%) had been submitted to previous surgical procedures or percutaneous interventions. Results: Early post-operative mortality was not seen, but two patients (11%), had late deaths, one due to endocarditis, a year after the Ross procedure, and the other due to dilated cardiomiopathy and mitral regurgitation. The shortest time of follow-up is 6 months and the longest 72 months (median 38 months). Of the 16 survivors, 14 patients are in class I of the NYHA and 2 in class II, without significant residual lesions or need for re-intervention. The 12 patients with more than a year of follow up revealed normal coronary perfusion in all patients and no segmental wall motion abnormalities. Nevertheless, two of the 12 patients developed residual dynamic obstruction of LVOT and in three patients aortic regurgitation of a mild to moderate degree was evident. Significant gradients were not verified in the RVOT. Conclusions: The Ross procedure, despite its complexity, can be undertaken with excellent immediate results. Aspects such as the dilation of the neo aortic root and homograft evolution can not be considered in a study of this nature, seeing that the mean follow up time does not exceed 5 years.

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Infective endocarditis (IE) is now rare in developed countries, but its prevalence is higher in elderly patients with prosthetic valves, diabetes, renal impairment, or heart failure. An increase in health-care associated IE (HCAIE) has been observed due to invasive maneuvers (30% of cases). Methicillin-resistant Staphylococcus aureus (MRSA) and Enterococcus are the most common agents in HCAIE, causing high mortality and morbidity. We review complications of IE and its therapy, based on a patient with acute bivalvular left-sided MRSA IE and a prosthetic aortic valve, aggravated by congestive heart failure, stroke, acute immune complex glomerulonephritis, Candida parapsilosis fungémia and death probably due to Serratia marcescens sepsis. The HCAIE was assumed to be related to three temporally associated in-hospital interventions considered as possible initial etiological mechanisms: overcrowding in the hospital environment,iv quinolone therapy and red blood cell transfusion. Later in the clinical course,C. parapsilosis and S. marcescens septicemia were considered to be possible secondary etiological mechanisms of HCAIE.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A deficiência congénita de anti-trombina III é considerada como um estado de hipercoagulabilidade primária. Os autores apresentam um caso de deficiência de anti-trombina III num jovem do sexo masculino, de 28 anos de idade, com doença valvular aórtica e múltiplos episódios de fenómenos tromboembólicos. Ao discutirem os seus aspectos diagnósticos e terapêuticos, procuram sensibilizar para a necessidade de se rastrear situações de trombofilia em doentes com fenómenos trombóticos recorrentes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

El presente trabajo contempla el estudio del comportamiento termomecánico de un motor monopropelente, cuyo funcionamiento se basa en la descomposición catalítica del combustible, produciendo la gasificación del mismo, con su consecuente generación de calor. Estos gases, al ser conducidos convenientemente a través de una tobera con el fin de generar su apropiada expansión, producirán la acción deseada. Un diseño erróneo del sistema de alimentación podría producir el acortamiento de la vida útil del catalizador, la degradación de los sellos de la válvula, vaporizaciones indeseadas del propelente, etc.El objetivo que se persigue es construir un modelo computacional que permita visualizar el comportamiento conjunto de los diversos fenómenos, la influencia de los diversos componentes y su interacción, a fin de identificar los elementos críticos, y poder así tomar acciones correctivas u operar sobre aspectos de diseño del sistema para un mejor acondicionamiento del combustible. Para la aplicación del método, se modelizarán cada uno de los fenómenos que gobiernan el comportamiento del sistema y se les codificará en lenguaje de programación, prestando especial atención al comportamiento del fluido tanto en régimen estable como durante los transitorios. Una vez validado el programa se correrán simulaciones para determinar la influencia de los parámetros básicos de diseño sobre los procesos termomecánicos mediante un análisis de sensitividad, a fin de mitigar los posibles efectos adversos. Sin embargo, durante la ejecución de proyectos de ingeniería de este tipo, una de las cuestiones de mayor importancia es el uso racional de materiales. Una adecuada utilización de los mismos tiene diversas ventajas, dentro de las cuales podemos citar como a las de mayor relevancia a: (i) mejor aprovechamiento de las capacidades de los materiales, (ii) elementos estructurales de menor tamaño, lo que genera una economía de espacio, (iii) menor costo económico y financiero del proyecto y (iv) menor impacto ambiental. En este sentido, una de las maneras más difundidas para el uso racional de materiales es, utilizar materiales con propiedades constitutivas que se adapten mejor a las características del proyecto en desarrollo. Sin embargo, cuando se está frente a la imposibilidad de cambiar de material o mejorar las propiedades existentes, es importante comenzar a utilizar otras metodologías que permitan un mejor aprovechamiento del mismo. Aquí surge naturalmente la necesidad de introducir cambios en la forma de los componentes estructurales que integran el proyecto ejecutivo. Para realizar una adecuada optimización de los componentes estructurales, es necesario previamente definir cual o cuales van a ser las características a optimizar y como van a ser medidas esas características durante el proceso de análisis. Por lo tanto, se propone aplicar el análisis de sensibilidad topológica para problemas termo-mecánicos para optimizar los componentes estructurales del motor.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

FUNDAMENTO: Nos últimos anos o numero de artigos sobre transplante cardíaco heterotópico tem sido escasso na literatura, inclusive internacional, e em particular do seguimento de longo prazo destes pacientes, o que levou ao presente relato. OBJETIVO: Relatar a experiência clínica inicial e evolução tardia de quatro pacientes submetidos a transplante cardíaco heterotópico, sua indicação e principais complicações. MÉTODOS: As cirurgias ocorreram entre 1992 e 2001, sendo que a indicação de transplante heterotópico, em todas, foi pela RVP, variável de 4,8UW a 6.5UW, com gradiente transpulmonar acima de 15mmHg. No 3º paciente, foi realizada uma anastomose direta entre as artérias pulmonares sem emprego de tubo protético e, no coração nativo, foi realizada uma valvoplastia mitral e aneurismectomia de ventrículo esquerdo (VE). O esquema imunossupressor imediato foi duplo com ciclosporina e azatioprina nos três primeiros pacientes e ciclosporina e micofenolato mofetil no 4º paciente. RESULTADOS: Um óbito imediato por falência do enxerto, um óbito após dois anos e meio por endocardite em trombo intraventricular no coração nativo, e um terceiro óbito seis anos após o transplante, por complicações pós-operatórias de cirurgia na valva aórtica do coração nativo. O remanescente, 15 anos após o transplante, encontra-se bem, em classe funcional II (NYHA), seis anos após a oclusão cirúrgica da valva aórtica do coração nativo. CONCLUSÃO: O transplante cardíaco heterotópico é um procedimento com resultado inferior ao transplante cardíaco ortotópico, por apresentarem maior RVP. Os trombos intraventriculares no coração nativo, que exigem anticoagulação prolongada, bem como as complicações de válvula aórtica, também no coração nativo, podem exigir tratamento cirúrgico. Entretanto, em um paciente, a sobrevida de 15 anos mostrou a eficácia de longo prazo desse tipo de alternativa, para pacientes selecionados.