817 resultados para Estação de Tratamento de Água (ETA)
Resumo:
The current study examined spatial-temporal modifications and water quality through chemical and biotic indicators during both dry (January, February and November 2006) and wet seasons (March to June 2006). This study was carried out in Armando Ribeiro Gonçalves Reservoir, RN, Canal do Pataxó and after the water station treatment (WST). The physical-chemical parameters were measured in situ and inorganic nutrients, chlorophyll a and Free Oxygen Demand (FOD) were analyzed in laboratory conditions. Quali quantitative analyses of phytoplankton were carried out utilizing Sedgwick-Rafter camera. Results indicate that DQO concentrations were low. FOD concentrations in the reservoir were comparatively higher in the dry season (5.21 mgL-1; 5.64 mgL-1 e 6.05 mgL-1) in relation to the wet season (4.52 mgL-1; 4.12 mgL-1 e 4.92 mgL-1), in surface, intermediate and bottom waters, respectively. FOD values were inferior to 1.0mgL-1in both Canal do Pataxó and after WST, which is considered adequate for public use reservoirs. Although FOD concentrations were low, Armando Ribeiro Gonçalves Reservoir, Canal do Pataxó and WST were classified as euthophizied, mesotrophic ad oligotrophic, respectively, considering the Index of Trophic State Criteria. Chlorophyll a concentrations in the study reservoir were higher in the surface (199.2 µgL-1) during the wet season, whereas in Canal do Pataxó concentrations decreased from 1.56 µgL-1 to 0.028 µgL-1, and after WST values were low (0.059 µgL-1). Dominance of cianobacterias, such as Planktotrhix agardhii (dry season) and Microcystis sp (wet season) was registered in all three areas. In the reservoir and Canal do Pataxó, density of cianobacterias, such as P. agardhii and Microcistys sp., was superior to the values allowed by the Health ministry (HM). However, after WST, density values of cianobacteria were inferior to values established by the HM
Resumo:
Dissertação de mest., Engenharia Biológica, Faculdade de Engenharia de Recursos Naturais, Universidade do Algarve, 2008
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
O objetivo do presente artigo é investigar a relação fluorose/cáries em escolas, de acordo com o nível de fluoreto no abastecimento público de água. A amostra consistiu em 360 alunos de doze anos de idade, de ambos os sexos, que frequentam as escolas próximas da região em que nasceram. As escolas foram classificadas em três grupos de acordo com a presença de fluoreto no abastecimento de água: 1) fluoretação na Estação de Tratamento de Água (ETA); 2) fluoretação direta em poços; e 3) áreas não fluoretadas (ANF). Os testes deχe de Goodman (significância = 5%) foram utilizados para avaliar a associação entre a origem da água e o grau de fluorose. Os resultados mais predominantes foram presença de cáries em toda a amostra (P<0,05); ausência de fluorose em ambos gêneros, para indivíduos brancos e aqueles vivendo em áreas abastecidas com água fluoretada diretamente de poços e não fluoretadas (P<0,05). Não houve diferença no grau de severidade da fluorose entre as fontes de abastecimento de água (P>0,05). As cáries ainda são uma importante questão nessa população, apesar do estabelecimento de medida preventiva. A observação da fluorose em alunos vivendo em áreas não fluoretadas confirma a presença de outras fontes de fluorose.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Este trabalho teve como objetivo avaliar a influência da unidade leito de contato na eficiência de remoção ferro em Estação de Tratamento de Água (ETA) tipo desferrização que trata água subterrânea. Os ensaios foram realizados em uma instalação piloto, composta por um aerador tipo tabuleiro, um leito de contato de fluxo ascendente e um filtro rápido de fluxo descendente, que tem capacidade para tratar cerca de 1,7m3/h. A ETA - piloto foi instalada no Setor Profissional do Campus Guamá da UFPA, sendo a água bruta proveniente de manancial subterrâneo, que contem ferro em teores elevados (em torno de 2mg/L). Na ETA - Piloto foram aplicadas taxas de filtração de 180m3/m2xdia, 270m3/m2xdia e 360m3/m2xdia em triplicata em duas fases experimentais: a primeira com leito de contato e segunda sem leito de contato. Foram monitoradas a carreira de filtração, a perda de carga e as variáveis: pH, Cor Aparente, Ferro (Total e Ferroso) e Turbidez. Para a Fase I as eficiências de remoção de ferro total obtidas para as taxas de filtração de 180m3/m2xdia, 270m3/m2xdia e 360m3/m2xdia foram de 93% a 94%, 85% a 95% e 91% a 92%, respectivamente. Para a Fase II as eficiências de remoção de ferro total ficaram em torno de 91% a 93%, 91% a 93% e 88% a 93%, respectivamente. As carreiras de filtração com leito de contato para as taxas de 180m3/m2xdia, 270m3/m2xdia e 360m3/m2xdia apresentaram tempo de duração média de 41h, 30h e 22,7h respectivamente, enquanto que na ausência de leito de contato a duração média foi de 16h, 12h e 4,7h, respectivamente. Dessa forma pode-se concluir que o leito de contato é uma unidade indispensável em uma ETA tipo desferrização, pois melhora o desempenho de sistema, produzindo efluente de boa qualidade e carreiras de filtração mais prolongadas.
Resumo:
Neste trabalho são apresentados os resultados de caracterização das principais argilas usadas pela indústria cerâmica vermelha regional e, também, de alguns resíduos sólidos produzidos na região de Presidente Prudente - SP. Os resultados da incorporação destes resíduos em massas cerâmicas são avaliados através do estudo de suas propriedades tecnológicas. Para a caracterização dos materiais foram utilizadas as seguintes técnicas: análise textural (concentração das frações areia, silte e argila), difratometria de raios X e análise térmica. As propriedades tecnológicas de corpos de prova cerâmicos foram avaliadas através dos seguintes parâmetros: retração linear (RL), perda de massa ao fogo (PF), massa específica aparente (MEA), porosidade aparente (PA), absorção de água (AA) e resistência mecânica à flexão (RMF). Corpos de prova, com diferentes concentrações de resíduos, foram prensados (prensa uniaxial manual) e queimados em temperaturas que variaram de 800 a 1200 oC, usando um forno tipo mufla com controle de temperatura. As argilas sedimentares foram coletadas nas margens do rio Paraná e em áreas de várzea, próximas as cerâmicas. As amostras estudadas, coletadas nos depósitos das cerâmicas, são usadas para produção de tijolos maciços, blocos furados e telhas. Quatro tipos diferentes de resíduos foram estudados: (1) lodo de estação de tratamento de água ETA, (2) torta de filtro de indústria de re-refino de óleo lubrificante, (3) pó de vidro (soda-cal) de garrafa tipo long neck descartável, e (4) cinza de bagaço de cana. Estes resíduos foram incorporados em massas cerâmicas coletadas nas indústrias... (Resumo completo, clicar acesso eletrônico abaixo)
Resumo:
Water quality is very important for the health and the population welfare, and the public supply system must provide water quality and suffi cient quantity for the entire population. Water treatment stations, are the main way to obtain water quality. When this doesn’t occur, several problems can affect the population, in this case, using water with poor quality is a constant risk of emergence causing various diseases. The elimination of microorganisms in treated water reduces competition, encouraging the multiplication of chlorine resistant bacteria as Mycobacterium genus frequently isolated from treated and chlorinated water. Considering the lack of indication from examinations of mycobacteria routine laboratory for quality control of drinking water and other human uses, the objective was to verify the presence isolate and identify the environmental mycobacteria in the system water source surface of Araraquara - SP. We analyzed 40 water samples, distributed as follows: ten water gross collected at Station Water Treatment Plant (WTP), harvested after ten fi ltration; ten collected in the reservoir after chlorination and ten in the network distribution. Were recovered 43 isolates of mycobacteria. All isolates were subjected to PCR-PRA. The mycobacteria were identifi ed as M. lentifl avum, M. parafortuitum, M. genavense, M. gordonae, M. fortuitum, M. confl uent, M. duvalii, M. avium subspecies paratuberculosis and M. szulgai. With these results, was concluded that water is an important source of environmental mycobacteria probably related to several human diseases, suggesting the carrying out continuous monitoring of the microorganisms in the system drinking water.
Resumo:
Dissertação de mestrado, Engenharia do Ambiente, Faculdade de Ciências e Tecnologia, Universidade do Algarve, 2015
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Disposição de resíduos gerados em estações de tratamento de água em estações de tratamento de esgoto
Resumo:
O presente trabalho foi realizado em duas fases. Na primeira, foram estimados os efeitos produzidos nos decantadores primários de uma ETE, após receber resíduo da ETA-SC, que utiliza sulfato de alumínio como coagulante. Foram realizados ensaios em colunas de sedimentação, onde os parâmetros SST, SSV, cor, turbidez, DQO, coliformes totais, Escherichia coli e parasitas, pesquisados no sobrenadante, diminuíram com o aumento da quantidade de resíduo adicionado. Com relação aos sedimentos obtidos nas colunas de sedimentação, foi encontrada maior quantidade de ST e menor resistência específica nos lodos provenientes das colunas que receberam os resíduos da ETA-SC. No teste de atividade metanogênica, a concentração molar de metano foi reduzida nos sistemas que receberam resíduo da ETA-SC, influenciando negativamente no desenvolvimento dos microrganismos metanogênicas. As espécies de microrganismos do gênero Methanothrix sp foram inibidas, sendo encontradas em maior número no frasco-reator controle e em menor quantidade a medida que se aumentou a quantidade do resíduo adicionado. Nesta etapa foi constatado que o resíduo da ETA-SC poderá apresentar interferências negativas sobre a digestão anaeróbia do lodo produzido em decantadores primários de uma ETE. Na segunda fase, na estação piloto, composta de lagoa de aeração seguida de lagoa de sedimentação, que recebeu resíduo da ETA-Fonte, que utiliza cloreto férrico como coagulante, foi verificado que tal resíduo melhorou a qualidade do efluente em termos de DQO, DBO, SST, turbidez, cor, amônio, nitrato, NTK e fosfato total. Os parâmetros ST, SDT, cloreto, nitrito, condutividade e pH não apresentaram diferenças significativas. Em relação ao exame microscópico não houve influências negativas no licor misto das lagoas de aeração. O lodo formado nas lagoas de sedimentação piloto apresentou-se em maior quantidade na lagoa que recebeu resíduo da ETA-Fonte. Neste lodo a resistência específica a filtração foi menor em comparação ao lodo da lagoa que não recebeu resíduo da ETA-Fonte. A desidratação deste lodo por centrifugação necessitou menor quantidade de polieletrólito. Baseado neste estudo não foi verificado interferências que possa impedir o lançamento do resíduo da ETA-Fonte na ETE-Araraquara.
Resumo:
O município do Rio de Janeiro, desde sua fundação luta com o grave problema de abastecimento de água. Com o passar do tempo todas as pequenas captações no entorno da cidade foram exauridas tanto em termos de quantidade como em qualidade, afetadas pela poluição decorrente do lançamento de efluentes in natura. Solução foi a busca por novas fontes de abastecimento em outros municípios. Atualmente 80% (oitenta por cento) do abastecimento da região metropolitana do Rio de Janeiro, RMRJ, é proveniente de uma única fonte: o rio Guandu. Isto foi possível devido à transposição da bacia do rio Paraíba do Sul para o rio Guandu ocorrida na década de 50. Esta fonte essencial de abastecimento, onde foi construída a maior Estação de Tratamento de Água do mundo - ETA Guandu - está à beira da exaustão. Somente uma pequena parcela de água bruta foi captada e tratada nesta última década. Visando minimizar o grave problema que já se apresenta e enquanto investimentos em novas alternativas não forem alcançados, o consumo com responsabilidade e sustentabilidade passa a ser a tônica da discussão. Neste contexto, as áreas de baixa renda do município com suas 801 favelas e mais de 1.500 loteamentos irregulares representando em 2010 aproximadamente 1/3 (um terço) da população total, consumindo de 10% a 15% de toda a produção de água tratada da região metropolitana deve ser permanentemente estimulada a contribuir com esta redução de consumo. Estudos apresentados nesta dissertação em três metodologias distintas apontam para um consumo acima da média nacional deste mesmo perfil de população. Os resultados obtidos indicam a necessidade real da redução de consumo observando, entretanto que este é um trabalho extremamente árduo e difícil uma vez que exige mudança de hábitos e a envolvimento de todos, desde a população até a Companhia de Saneamento local.
Resumo:
Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Mecânica