985 resultados para Electrochemical determination


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Voltammetric methods are applicable for the determination of a wide variety of both organic and inorganic species. Its features are compact equipment, simple sample preparation, short analysis time, high accuracy and sensitivity. Voltammetry is especially suitable for laboratories in which only a few parameters have to be monitored with a moderate sample throughput. Of various electrode materials, glassy carbon electrode is particularly useful because of its high electrical conductivity, impermeability to gases, high chemical resistance, reasonable mechanical and dimensional stability and widest potential range of all carbonaceous electrodes. Electrode modification is a vigorous research area by which the electrochemical determination of various analyte species is facilitated. The scope of pharmaceutical analysis includes the analytical investigation of pure drug, drug formulations, impurities and degradation products of drugs, biological samples containing the drugs and their metabolites with the aim of obtaining data that can contribute to the maximal efficacy and maximal safety of drug therapy. This thesis presents the modification of glassy carbon electrode using metalloporphyrin and dyes and subsequently using these modified electrodes for the determination of various pharmaceuticals. The thesis consists of 9 chapters.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The electrochemical detection of the hazardous pollutant 4-nitrophenol (4-NP) at low potentials, in order to avoid matrix interferences, is an important research challenge. This study describes the development, electrochemical characterization and utilization of a multiwall carbon nanotube (MWCNT) film electrode for the quantitative determination of 4-NP in natural water. Electrochemical impedence spectroscopy measurements showed that the modified surface exhibits a decrease of ca. 13 times in the charge transfer resistance when compared with a bare glassy carbon (GC) surface. Voltammetric experiments showed the possibility to oxidize a hydroxylamine layer (produced by the electrochemical reduction of 4-NP on the GC/MWNCT surface) in a potential region which is approximately 700 mV less positive than that needed to oxidize 4-NP, thus minimizing the interference of matrix components. The limit of detection for 4-NP obtained using square-wave voltammetry (0.12 mu mol L(-1)) was lower than the value advised by EPA. A natural water sample from a dam located in Sao Carlos (Brazil) was spiked with 4-NP and analyzed by the standard addition method using thee GC/MWCNT electrode, without any further purification step. the recovery procedure yielded a value of 96.5% for such sample, thus confirming the suitability of the developed method to determine 4-NP in natural water samples. The electrochemical determination was compared with that obtained by HPLC with UV-vis detection.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This work describes the development, electrochemical characterization and utilization of a cobalt phthalocyanine modified carbon nanotube electrode for the quantitative determination of dopamine in 0.2 mol L-1 phosphate buffer contaminated with high concentration of ascorbic acid. The electrode surface was analyzed by cyclic voltammetry and electrochemical impedance spectroscopy which showed a modified surface presenting a charge transfer resistance of 500 Omega, against the 16.46 k Omega value found for the bare glassy carbon surface. A pseudo rate constant value of 5.4 x 10(-4) cm s(-1) for dopamine oxidation was calculated. Voltammetric experiments showed a shift of the peak potential of DA oxidation to less positive value at 390 mV as compared with that of a bare GC electrode at 570 mV. The electrochemical determination of dopamine, in presence of ascorbic acid in concentrations up to 0.1 mol L-1 by differential pulse voltarnmetry, yielded a detection limit as low as 2.56 x 10(-7) mol L-1.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Propõe-se método novo e completo para análise de acetona em ar exalado envolvendo coleta com pré-concentração em água, derivatização química e determinação eletroquímica assistida por novo algoritmo de processamento de sinais. Na literatura recente a acetona expirada vem sendo avaliada como biomarcador para monitoramento não invasivo de quadros clínicos como diabetes e insuficiência cardíaca, daí a importância da proposta. Entre as aminas que reagem com acetona para formar iminas eletroativas, estudadas por polarografia em meados do século passado, a glicina apresentou melhor conjunto de características para a definição do método de determinação por voltametria de onda quadrada sem a necessidade de remoção de oxigênio (25 Hz, amplitude de 20 mV, incremento de 5 mV, eletrodo de gota de mercúrio). O meio reacional, composto de glicina (2 mol·L-1) em meio NaOH (1 mol·L-1), serviu também de eletrólito e o pico de redução da imina em -1,57 V vs. Ag|AgCl constituiu o sinal analítico. Para tratamento dos sinais, foi desenvolvido e avaliado um algoritmo inovador baseado em interpolação de linha base por ajuste de curvas de Bézier e ajuste de gaussiana ao pico. Essa combinação permitiu reconhecimento e quantificação de picos relativamente baixos e largos sobre linha com curvatura acentuada e ruído, situação em que métodos convencionais falham e curvas do tipo spline se mostraram menos apropriadas. A implementação do algoritmo (disponível em http://github.com/batistagl/chemapps) foi realizada utilizando programa open source de álgebra matricial integrado diretamente com software de controle do potenciostato. Para demonstrar a generalidade da extensão dos recursos nativos do equipamento mediante integração com programação externa em linguagem Octave (open source), implementou-se a técnica da cronocoulometria tridimensional, com visualização de resultados já tratados em projeções de malha de perspectiva 3D sob qualquer ângulo. A determinação eletroquímica de acetona em fase aquosa, assistida pelo algoritmo baseado em curvas de Bézier, é rápida e automática, tem limite de detecção de 3,5·10-6 mol·L-1 (0,2 mg·L-1) e faixa linear que atende aos requisitos da análise em ar exalado. O acetaldeído, comumente presente em ar exalado, em especial, após consumo de bebidas alcoólicas, dá origem a pico voltamétrico em -1,40 V, contornando interferência que prejudica vários outros métodos publicados na literatura e abrindo possibilidade de determinação simultânea. Resultados obtidos com amostras reais são concordantes com os obtidos por método espectrofotométrico, em uso rotineiro desde o seu aperfeiçoamento na dissertação de mestrado do autor desta tese. Em relação à dissertação, também se otimizou a geometria do dispositivo de coleta, de modo a concentrar a acetona num volume menor de água gelada e prover maior conforto ao paciente. O método completo apresentado, englobando o dispositivo de amostragem aperfeiçoado e o novo e efetivo algoritmo para tratamento automático de sinais voltamétricos, está pronto para ser aplicado. Evolução para um analisador portátil depende de melhorias no limite de detecção e facilidade de obtenção eletrodos sólidos (impressos) com filme de mercúrio, vez que eletrodos de bismuto ou diamante dopado com boro, entre outros, não apresentaram resposta.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Metallic Ru has been found to coexist separately with CaO, RuO2, and the interoxide phases, Ca2RuO4, Ca3Ru2O7, and CaRuO3, present along the pseudobinary system CaO-RuO2. The standard Gibbs energies of formation (Df((ox))G(o)) of the three calcium ruthenates from their component oxides have been measured in the temperature range 925-1350 K using solid-state cells with yttria-stabilized zirconia as the electrolyte and Ru+RuO2 as the reference electrode. The standard Gibbs energies of formation (Deltaf((ox))G(o)) of the compounds can be represented by Ca2RuO4:Deltaf((ox))G(o)/J mol(-1)=-38,340-6.611 T (+/-120), Ca3Ru2O7 : Df((ox))G(o)/J mol(-1)=-75,910-11.26 T (+/-180), and CaRuO3 : Deltaf((ox))G(o)/J mol(-1)=-35,480-3.844 T(+/-70). The data for Ca2RuO4 corresponds to the stoichiometric composition, which has an orthorhombic structure, space group Pbca, with short c axis ("S'' form). The structural features of the ternary oxides responsible for their mild entropy stabilization are discussed. A three-dimensional oxygen potential diagram for the system Ca-Ru-O is developed as a function of composition and temperature from the results obtained. Using the Neumann-Kopp rule to estimate the heat capacity of the ternary oxides relative to their constituent binary oxides, the standard enthalpies of formation of the three calcium ruthenates from the elements and their standard entropies at 298.15 K are evaluated. (C) 2003 The Electrochemical Society.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Carbon modified by the reduction of aromatic diazonium derivatives was first used as electrode for the electrochemical stripping analysis of heavy metals. As a model, the glassy carbon electrode was modified with benzoic acid by electrochemical reduction of diazobenzoic acid, and the resulting modified electrodes were used for determination of Cd2+ and Pb2+. The anodic peak currents of cadmium and lead at the benzoic acid-modified glassy carbon electrode are 7.2 and 6 times of that at the bare glassy carbon electrode. A linear response was observed for Pb2+ and Cd2+ in the range of 0.5-50 mu g/l.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Three beta -blockers (propranolol, timolol, acebutolol) were separated by capillary electrophoresis (CE) and detected by end-column electrochemical detection (EC). In the present work, a carbon fiber (33 mum) electrode was used as the working electrode. The effect of the buffer concentration, buffer pH, detection potential and separation voltage on the separation of analytes and behavior of electrochemical detection was systematically investigated. The optimum conditions determined were as following: 40 cm length, 25 mum i.d. capillary; 17.5 kV separation voltage; 2 s injection at 15 kV; 70mM phosphate buffer, pH 3.5; detection potential + 1.2V (vs. Ag/AgCl). Under these conditions, the linear ranges of beta -blockers were over three orders of magnititude and the low detection limit of 10(-8)M was obtained. This method was also applied to detect the simulated urine sample.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Capillary electrophoresis (CE) with end-column electrochemical detection (EC) of barbituric acid (BA) and 2-thiobarbituric acid (TA) has been described. Under optimum condition, BA and TA were separated satisfactorily, and a response of high sensitivity and stability was obtained at a detection potential of 1.25 V versus Ag/AgCl. Optimized end-column detection provides detection limit as low as 0.5 and 0.1 mu M for BA and TA, respectively. The calibration graph was linear over three orders of magnitude. The relative standard deviations (n = 10) of peak currents and migration times obtained for both BA and TA were 3.4, 3.7, and 1.7, 1.2%, respectively. The proposed method has been applied to analyze water sample with satisfactory results. (C) 2000 Elsevier Science B.V. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The self-assembled monolayer(SAM) of 11-mercaptoundecanoic acid [HS(CH2)(10)COOH] was formed on a gold electrode and the effect of the charge of end group on the electrochemical response of Fe(CN)(6)(3-) at the SAM modified electrode was studied by cyclic voltammetry. At high pH, when the -COOH groups are dissociated, the current of Fe(CN)(6)(3-) is suppressed; as the solution pH is lowered, the current of Fe(CN)(6)(3-) increases. The electrochemical titration curve was obtained by correlating the currents of Fe(CN)(6)(3-) to the different pH values of electrolyte, from which the surface pK(a) was obtained to be 3. 0+/-0. 2. Furthermore, the reason of small pK(a) value was explained using SAMs of different surface coverage.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A novel method is employed for the simultaneous determination of both the calibration constant of an electrochemical quartz crystal microbalance (EQCM) and the active surface area of a polycrystalline gold electrode. A gold electrode: is immersed into a 1 mM KI/1 M H2SO4 solution and on which forms a neutral monolayer. The adsorbed iodine can then be completely oxidized into IO3-. The active surface area of a gold electrode can be obtained from the net electrolytic charge of the oxidation process, and the calibration constant in the EQCM can be calculated from the corresponding frequency shift. The result shows that this method is simple, convenient and valid. (C) 2000 Elsevier Science S.A. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A self-assembled monolayer (SAM) of 3-mercaptopropionic acid (HSCH2CH2COOH) was formed on a gold electrode. The effect of the charge of the end group on the electrochemical response of Fe(CN)(6)(3-) at the SAM modified electrode was studied by using cyclic voltammetry. At high pH, when the -COOH groups are dissociated, Fe(CN)(6)(3-) current is suppressed; as the solution pH is lowered, Fe(CN)(6)(3-) current increases. The electrochemical titration curve was obtained by correlating the currents to the different electrolyte pH values, from which the surface pK(a) was obtained to be 5.2+/-0.1. Furthermore, a calculation equation was presented to simulate the electrochemical titration. As comparison, the surface pK(a) was also measured by contact angle titration as 5.6+/-0.1. The surface pK(a) values determined by the two methods in our work are consistent and accurate.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Capillary electrophoresis (CE) with end-column electrochemical detection (EC) of sulfadiazine (SDZ) and sulfamethoxazole (SMZ) is described. Under the optimum conditions, SDZ and SMZ were separated satisfactorily, and a highly sensitive and stable response was obtained at a potential of 1.1 V versus Ag/AgCl. Optimized end-column detection provides detection limits as low as 0.1 mu M for both compounds, which corresponds to 0.024 and 0.021 fmol with peak efficiencies of 394000 and 335000 theoretical plates for SDZ arid SMZ, respectively. The calibration graph was linear over three orders of magnitude. The relative standard deviations (n = 12) of peak currents and migration times were 2.3 and 2.7%, and 0.8 and 1.3%, respectively, for the two compounds. The proposed method was applied to the analysis of tablets and human urine samples with satisfactory results.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A highly dispersed ultramicro palladium-particle modified carbon fiber microdisk array electrode (Pd-CFE) was employed for capillary electrophoresis-electrochemical (CEEC) detection of hydroxylamine (HA). The Pd particles obtained were in the nanometer scale, had a high electrocatalytic activity towards HA and exhibited good reproducibility and stability. A linear relationship between the current and the analyte concentration was found between 5 x 10(-6) and 1 x 10(-3) mol/l of HA with a correlation coefficient of 0.9992. The detection limit was 5 x 10(-8) mol/l. The applicability of the method for the determination of HA in river water and waste water was investigated.