887 resultados para Ejaculation frequency
Resumo:
The influence of impeller type and stirring frequency on the performance of a mechanically stirred anaerobic sequencing batch reactor containing immobilized biomass on an inert support (AnSBBR - Anaerobic Sequencing Batch Biofilm Reactor) was evaluated. The biomass was immobilized on polyurethane foam cubes placed in a stainless-steel basket inside a glass cylinder. Each 8-h batch run consisted of three stages: feed (10 min), reaction (460 min) and discharge (10 min) at 30 degrees C. Experiments were performed with four impeller types, i.e., helical, flat-blade, inclined-blade and curved-blade turbines, at stirring frequencies ranging from 100 to 1100 rpm. Synthetic wastewater was used in all experiments with an organic-matter concentration of 530 +/- 37 mg/L measured as chemical oxygen demand (COD). The reactor achieved an organic-matter removal efficiency of around 87% under all investigated conditions. Analysis of the four impeller types and the investigated stirring frequencies showed that mass transfer in the liquid phase was affected not only by the applied stirring frequency but also by the agitation mode imposed by each impeller type. The best reactor performance at all stirring frequencies was obtained when agitation was provided by the flat-blade turbine impeller. (C) 2010 Elsevier Ltd. All rights reserved.
Resumo:
The impact of the titanium nitride (TIN) gate electrode thickness has been investigated in n and p channel SOI multiple gate field effect transistors (MuGFETs) through low frequency noise charge pumping and static measurements as well as capacitance-voltage curves The results suggest that a thicker TIN metal gate electrode gives rise to a higher EOT a lower mobility and a higher interface trap density The devices have also been studied for different back gate biases where the GIFBE onset occurs at lower front-gate voltage for thinner TIN metal gate thickness and at higher V(GF) In addition it is demonstrated that post deposition nitridation of the MOCVD HfSiO gate dielectric exhibits an unexpected trend with TIN gate electrode thickness where a continuous variation of EOT and an increase on the degradation of the interface quality are observed (C) 2010 Elsevier Ltd All rights reserved
Resumo:
In order to provide adequate multivariate measures of information flow between neural structures, modified expressions of partial directed coherence (PDC) and directed transfer function (DTF), two popular multivariate connectivity measures employed in neuroscience, are introduced and their formal relationship to mutual information rates are proved.
Resumo:
One-way master-slave (OWMS) chain networks are widely used in clock distribution systems due to their reliability and low cost. As the network nodes are phase-locked loops (PLLs), double-frequency jitter (DFJ) caused by their phase detectors appears as an impairment to the performance of the clock recovering process found in communication systems and instrumentation applications. A nonlinear model for OWMS chain networks with P + 1 order PLLs as slave nodes is presented, considering the DFJ. Since higher order filters are more effective in filtering DFJ, the synchronous state stability conditions for an OWMS chain network with third-order nodes are derived, relating the loop gain and the filter coefficients. By using these conditions, design examples are discussed.
Resumo:
The atomic force microscope (AFM) introduced the surface investigation with true atomic resolution. In the frequency modulation technique (FM-AFM) both the amplitude and the frequency of oscillation of the micro-cantilever must be kept constant even in the presence of tip-surface interaction forces. For that reason, the proper design of the Phase-Locked Loop (PLL) used in FM-AFM is vital to system performance. Here, the mathematical model of the FM-AFM control system is derived considering high order PLL In addition a method to design stable third-order Phase-Locked Loops is presented. (C) 2010 Elsevier B.V. All rights reserved.
Resumo:
Functional magnetic resonance imaging (fMRI) has become an important tool in Neuroscience due to its noninvasive and high spatial resolution properties compared to other methods like PET or EEG. Characterization of the neural connectivity has been the aim of several cognitive researches, as the interactions among cortical areas lie at the heart of many brain dysfunctions and mental disorders. Several methods like correlation analysis, structural equation modeling, and dynamic causal models have been proposed to quantify connectivity strength. An important concept related to connectivity modeling is Granger causality, which is one of the most popular definitions for the measure of directional dependence between time series. In this article, we propose the application of the partial directed coherence (PDC) for the connectivity analysis of multisubject fMRI data using multivariate bootstrap. PDC is a frequency domain counterpart of Granger causality and has become a very prominent tool in EEG studies. The achieved frequency decomposition of connectivity is useful in separating interactions from neural modules from those originating in scanner noise, breath, and heart beating. Real fMRI dataset of six subjects executing a language processing protocol was used for the analysis of connectivity. Hum Brain Mapp 30:452-461, 2009. (C) 2007 Wiley-Liss, Inc.
Resumo:
Tendon reflexes have been often used in studies of the human nervous system in health and disease. They have been investigated either in response to single tendon taps or to long duration vibrations. Tendon reflexes are described here in response to a high frequency vibration burst (3 cycles of a 100 Hz sine wave) applied to the Achilles tendon of standing subjects, either in quiet stance or during a forward leaning posture. The electromyogram from the soleus muscle usually showed three components separated by 10 ms which were interpreted as being three reflexes, each reflex induced by each of the three cycles in a burst. This result indicates that soleus tendon reflexes can respond in fast succession in a phasic manner when a brief high frequency vibration is applied to the Achilles tendon. This occurs in spite of possible depression of the la to motoneuron synapses and the long after hyperpolarization of the motoneurons. An interpretation of the results is that motoneurons from different subsets of the motoneuron pool respond to different cycles of the sinusoidal vibratory burst. (c) 2008 Elsevier Ireland Ltd. All rights reserved.
Resumo:
The double-frequency jitter is one of the main problems in clock distribution networks. In previous works, sonic analytical and numerical aspects of this phenomenon were studied and results were obtained for one-way master-slave (OWMS) architectures. Here, an experimental apparatus is implemented, allowing to measure the power of the double-frequency signal and to confirm the theoretical conjectures. (C) 2008 Elsevier B.V. All rights reserved.
Resumo:
Limited data are available about iron deficiency (ID) in Brazilian blood donors. This study evaluated the frequencies of ID and iron-deficiency anaemia (IDA) separately and according to frequency of blood donations. The protective effect of the heterozygous genotype for HFE C282Y mutation against ID and IDA in female blood donors was also determined. Five hundred and eight blood donors were recruited at the Blood Bank of Santa Casa in Sao Paulo, Brazil. Haemoglobin and serum ferritin concentrations were measured. The genotype for HFE C282Y mutation was determined by polymerase chain reaction followed by restriction fragment length polymorphism analysis. The ID was found in 21 center dot 1% of the women and 2 center dot 6% of the men whereas the IDA was found in 6 center dot 8 and 0 center dot 3%, respectively. The ID was found in 11 center dot 9% of the women in group 1 (first-time blood donors) and the frequency increased to 38 center dot 9% in women of the group 3 (blood donors donating once or more times in the last 12 months). No ID was found in men from group 1; however the ID frequency increased to 0 center dot 9% in group 2 (who had donated blood before but not in the last 12 months) and 5 center dot 0% in group 3. In summary, the heterozygous genotype was not associated with reduction of ID or IDA frequencies in both genders, but in male blood donors it was associated with a trend to elevated ferritin levels (P = 0 center dot 060). ID is most frequent in Brazilian women but was also found in men of group 3.
Resumo:
The feasibility of detecting instability in wet spouted beds via pressure fluctuation (PF) time-series analyses was investigated. Experiments were carried out in a cylindrical Plexiglas column of diameter 150 mm with a conical base of internal angle 60 degrees, an inlet orifice diameter of 25 mm and glass beads of diameter 2.4 mm. Transducers at several axial positions measured PF time series with incremental addition of aqueous sucrose solutions of different concentrations. Liquid addition affected the spouted bed dynamics, causing irregular spouting, increased voidage in the annulus, increased fountain height, irregular annulus height, channelling, agglomeration, and adhesion of particles to the column walls. Autocorrelations indicated the appearance of periodicities in the PF signals with increasing sucrose addition. Dominant peaks in power-spectral density developed at low frequencies with changing system dynamics. The results indicate that PF signals furnish relevant information on system dynamics, useful for monitoring and control of spouted bed operations such as particle coating and drying of paste-like materials.
Resumo:
The purposes of this study were to evaluate in vitro the influence of different frequencies of Er:YAG laser on the human dentin caries removal capacity. Thirty fragments obtained from third molars were randomly assigned into three groups (n = 10) according to the laser frequency used: 4, 6, and 10 Hz. The caries lesion (+/-1 mm deep) was induced before the irradiation by S. mutans cultures for 6 weeks. The specimens of all groups were irradiated with 200 mJ of energy in noncontact and focused mode under constant refrigeration (water flow: 2.5 mL/min). Quantitative analysis of the caries removal was performed by DIAGNOdent (TM) and the Axion Vision (TM) software. Qualitative analysis was performed by Scanning electron microscope (SEM) and light microscope (LM). Data were analyzed by ANOVA and Fishers` tests. The DIAGNOdent (TM) revealed that the caries removal was similar with 4 and 6 Hz and was superior with 10 Hz (P < 0.05). The analysis with Axion Vision (TM) software revealed that the caries removal was similar with 6 and 10 Hz and the 4 Hz group promoted the lowest caries removal. Through SEM morphologic analysis, some specimens irradiated with 4 Hz presented, under the demineralized dentin, a disorganized collagenous matrix. The LM images revealed that all frequencies used promoted irregular caries removal, being observed over preparations with 6 and 10 Hz. It can be concluded that the increase of Er:YAG laser frequency provided a higher dentin caries removal without selectivity to the disorganized dentin. Microsc. Res. Tech. 74:281-286, 2011. (C) 2010 Wiley-Liss, Inc.
Resumo:
Objectives: The aim of this study was to evaluate the fluoride intake of 2-6-year-old Brazilian children using a semiquantitative food frequency questionnaire (FFQ) which also estimated fluoride intake from dentifrice. Methods: The FFQ was previously validated through application to 78 2-6-year-old Brazilian children and then administered to 379 children residing in an optimally fluoridated community in Brazil (Bauru, State of Sao Paulo). The FFQ was applied to the parents and used to estimate the food intake of the children. The constituents of the diet were divided into solids, water and other beverages. The fluoride content of the diet items was analyzed with the fluoride electrode. The questionnaire also estimated fluoride intake from dentifrice. Results: The average (+/- SD) fluoride intake from solids, water, other beverages and dentifrice was 0.008 +/- 0.005; 0.011 +/- 0.004; 0.009 +/- 0.014 and 0.036 +/- 0.028 mg F/kg body weight/day, respectively, totalizing 0.064 +/- 0.035 mg F/kg body weight/day. The dentifrice and the diet contributed with 56.3% and 43.7% of the daily fluoride intake, respectively. Among the children evaluated, 31.2% are estimated to have risk to develop dental fluorosis (intake > 0.07 mg F/kg body weight/day). Conclusions: The dentifrice was the main source of fluoride intake by the children evaluated. However, the fluoride concentration in food items also significantly contributed to the daily ingestion by 2-6-year-old children. The questionnaire used seems to be a promising alternative to duplicate diet to estimate the fluoride intake at this age range and may have potential to be used in broad epidemiological surveys.
Resumo:
The characteristics of high frequency (1000 Hz) acoustic admittance results obtained from normal neonates were described in this study. Participants were 170 healthy neonates (96 boys and 74 girls) aged between 1 and 6 days (mean = 3.26 days, SD = 0.92). Transient evoked otoacoustic emissions (TEOAEs), and 226 Hz and 1000 Hz probe tone tympanograms were obtained from the participants using a Madsen Capella OAE/middle ear analyser. The results showed that of the 170 neonates, 34 were not successfully tested in both ears, 14 failed the TEOAE screen in one or both ears, and 122 (70 boys, 52 girls) passed the TEOAE screen in both ears and also maintained an acceptable probe seal during tympanometry. The 1000 Hz tympanometric data for the 122 neonates (244 ears) showed a single-peaked tympanogram in 225 ears (92.2 %), a flat-sloping tympanogram in 14 ears (5.7 %), a double-peaked tympanogram in 3 ears (1.2 %) and other unusual shapes in 2 ears (0.8 %). There was a significant ear effect, with right ears showing significantly higher mean peak compensated static admittance and tympanometric width, but lower mean acoustic admittance at +200 daPa and gradient than left ears. No significant gender effects or its interaction with ear were found. The normative tympanometric data derived from this cohort may serve as a guide for detecting middle ear dysfunction in neonates.
Resumo:
A narrow absorption feature in an atomic or molecular gas (such as iodine or methane) is used as the frequency reference in many stabilized lasers. As part of the stabilization scheme an optical frequency dither is applied to the laser. In optical heterodyne experiments, this dither is transferred to the RF beat signal, reducing the spectral power density and hence the signal to noise ratio over that in the absence of dither. We removed the dither by mixing the raw beat signal with a dithered local oscillator signal. When the dither waveform is matched to that of the reference laser the output signal from the mixer is rendered dither free. Application of this method to a Winters iodine-stabilized helium-neon laser reduced the bandwidth of the beat signal from 6 MHz to 390 kHz, thereby lowering the detection threshold from 5 pW of laser power to 3 pW. In addition, a simple signal detection model is developed which predicts similar threshold reductions.
Resumo:
The present study details new turbulence field measurements conducted continuously at high frequency for 50 hours in the upper zone of a small subtropical estuary with semi-diurnal tides. Acoustic Doppler velocimetry was used, and the signal was post-processed thoroughly. The suspended sediment concentration wad further deduced from the acoustic backscatter intensity. The field data set demonstrated some unique flow features of the upstream estuarine zone, including some low-frequency longitudinal oscillations induced by internal and external resonance. A striking feature of the data set is the large fluctuations in all turbulence properties and suspended sediment concentration during the tidal cycle. This feature has been rarely documented.