Resumo:
AIM: To evaluate the prediction error in intraocular lens (IOL) power calculation for a rotationally asymmetric refractive multifocal IOL and the impact on this error of the optimization of the keratometric estimation of the corneal power and the prediction of the effective lens position (ELP). METHODS: Retrospective study including a total of 25 eyes of 13 patients (age, 50 to 83y) with previous cataract surgery with implantation of the Lentis Mplus LS-312 IOL (Oculentis GmbH, Germany). In all cases, an adjusted IOL power (PIOLadj) was calculated based on Gaussian optics using a variable keratometric index value (nkadj) for the estimation of the corneal power (Pkadj) and on a new value for ELP (ELPadj) obtained by multiple regression analysis. This PIOLadj was compared with the IOL power implanted (PIOLReal) and the value proposed by three conventional formulas (Haigis, Hoffer Q and Holladay). RESULTS: PIOLReal was not significantly different than PIOLadj and Holladay IOL power (P>0.05). In the Bland and Altman analysis, PIOLadj showed lower mean difference (-0.07 D) and limits of agreement (of 1.47 and -1.61 D) when compared to PIOLReal than the IOL power value obtained with the Holladay formula. Furthermore, ELPadj was significantly lower than ELP calculated with other conventional formulas (P<0.01) and was found to be dependent on axial length, anterior chamber depth and Pkadj. CONCLUSION: Refractive outcomes after cataract surgery with implantation of the multifocal IOL Lentis Mplus LS-312 can be optimized by minimizing the keratometric error and by estimating ELP using a mathematical expression dependent on anatomical factors.
Resumo:
Purpose: To evaluate the effect of reducing the number of visual acuity measurements made in a defocus curve on the quality of data quantified. Setting: Midland Eye, Solihull, United Kingdom. Design: Evaluation of a technique. Methods: Defocus curves were constructed by measuring visual acuity on a distance logMAR letter chart, randomizing the test letters between lens presentations. The lens powers evaluated ranged between +1.50 diopters (D) and -5.00 D in 0.50 D steps, which were also presented in a randomized order. Defocus curves were measured binocularly with the Tecnis diffractive, Rezoom refractive, Lentis rotationally asymmetric segmented (+3.00 D addition [add]), and Finevision trifocal multifocal intraocular lenses (IOLs) implanted bilaterally, and also for the diffractive IOL and refractive or rotationally asymmetric segmented (+3.00 D and +1.50 D adds) multifocal IOLs implanted contralaterally. Relative and absolute range of clear-focus metrics and area metrics were calculated for curves fitted using 0.50 D, 1.00 D, and 1.50 D steps and a near add-specific profile (ie, distance, half the near add, and the full near-add powers). Results: A significant difference in simulated results was found in at least 1 of the relative or absolute range of clear-focus or area metrics for each of the multifocal designs examined when the defocus-curve step size was increased (P<.05). Conclusion: Faster methods of capturing defocus curves from multifocal IOL designs appear to distort the metric results and are therefore not valid. Financial Disclosure: No author has a financial or proprietary interest in any material or method mentioned. © 2013 ASCRS and ESCRS.