1000 resultados para Current


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Multi-output boost (MOB) converter is a novel DC-DC converter unlike the regular boost converter, has the ability to share its total output voltage and to have different series output voltage from a given duty cycle for low and high power applications. In this paper, discrete voltage control with inner hysteresis current control loop has been proposed to keep the simplicity of the control law for the double-output MOB converter, which can be implemented by a combination of analogue and logical ICs or simple microcontroller to constrain the output voltages of MOB converter at their reference voltages against variation in load or input voltage. The salient features of the proposed control strategy are simplicity of implementation and ease to extend to multiple outputs in the MOB converter. Simulation and experimental results are presented to show the validity of control strategy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents the possibility of utilizing a current source topology instead of a voltage source as an efficient, flexible and reliable power supply for plasma applications. A buck-boost converter with a current controller has been used to transfer energy from an inductor to a plasma system. A control strategy has also been designed to satisfy all the desired purposes. The main concept behind this topology is to provide high dv/dt regardless of the switching speed of a power switch and to control the current level to properly transfer adequate energy to various plasma applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Multilevel inverters provide an attractive solution for power electronics when both reduced harmonic contents and high voltages are required. In this paper, a novel predictive current control technique is proposed for a three-phase multilevel inverter, which controls the capacitors voltages and load currents with low switching losses. The advantage of this contribution is that the technique can be applied to more voltage levels without significantly changing the control circuit. The three-phase three-level inverter with a pure inductive load has been implemented to track reference currents using analogue circuits and programmable logic device.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Correct use of child restraints reduces the risk of death and injury. Use of adult seat belts is better than being unrestrained but can result in injury to children who are too small. New Australian legislation extends the requirement for using child-specific restraints until children are 7 years old and thus requires more appropriate levels of protection for these children. As part of a larger study of injury prevention in Queensland, parents of children 0-9 years old were surveyed regarding their restraint practices before the introduction of the new legislation. The restraint status of 18% of the children would not be compliant with the new legislation, with the problem being more prevalent for 5-9 year olds (22%) than 0-4 year olds (16%). A high proportion of older children used an adult seat belt. Very few children aged 0-4 (1.3%) usually travelled in the front seat in contravention of the new requirement, but around 11% of this age group were reported as ever having done so. Usual travel in the front seat was higher among 5-9 year olds (8.5%), with more than half of the 5-9 year olds reported as ever having done so. Given the widespread use of adult seat belts by older children, there is a need to consider improving protection of children in the ‘gap’ between when the requirement for the child to use a booster ceases (effectively age 7) and when the adult belt is likely to actually fit the child (closer to age 9 or 10).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Botnets are large networks of compromised machines under the control of a bot master. These botnets constantly evolve their defences to allow the continuation of their malicious activities. The constant development of new botnet mitigation strategies and their subsequent defensive countermeasures has lead to a technological arms race, one which the bot masters have significant incentives to win. This dissertation analyzes the current and future states of the botnet arms race by introducing a taxonomy of botnet defences and a simulation framework for evaluating botnet techniques. The taxonomy covers current botnet techniques and highlights possible future techniques for further analysis under the simulation framework. This framework allows the evaluation of the effect techniques such as reputation systems and proof of work schemes have on the resources required to disable a peer-to-peer botnet. Given the increase in the resources required, our results suggest that the prospects of eliminating the botnet threat are limited.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Mood and anxiety disorders pose significant health burdens on the community. Kava and St John’s wort (SJW) are the most commonly used herbal medicines in the treatment of anxiety and depressive disorders, respectively. Objectives: To conduct a comprehensive review of kava and SJW, to review any evidence of efficacy, mode of action, pharmacokinetics, safety and use in Major Depressive Disorder (MDD), Bipolar Disorder (BP), Seasonal Affective Disorder (SAD), Generalized Anxiety Disorder (GAD), Social Phobia (SP), Panic Disorder (PD), Obsessive-Compulsive Disorder (OCD), and Post Traumatic Stress Disorder (PTSD). Methods: A systematic review was conducted using the electronic databases MEDLINE, CINAHL, and The Cochrane Library during late 2008. The search criteria involved mood and anxiety disorder search terms in combination with kava, Piper methysticum, kavalactones, St John’s wort, Hypericum perforatum, hypericin and hyperforin. Additional search criteria for safety, pharmacodynamics , and pharmacokinetics was employed. A subsequent forward search was conducted of the papers using Web of Science cited reference search. Results: Current evidence supports the use of SJW in treating mild-moderate depression, and for kava in treatment of generalized anxiety. In respect to the other disorders, only weak preliminary evidence exists for use of SJW in SAD. Currently there is no published human trial on use of kava in affective disorders, or in OCD, PTSD, PD or SP. These disorders constitute potential applications that warrant exploration. Conclusions: Current evidence for herbal medicines in the treatment of depression and anxiety only supports the use of Hypericum perforatum for depression, and Piper methysticum for generalized anxiety.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: The evidence was reviewed on how physical activity could influence the regulation of food intake by either adjusting the sensitivity of appetite control mechanisms or by generating an energy deficit that could adjust the drive to eat. Design: Interventionist and correlational studies that had a significant influence on the relationship between physical activity and food intake were reviewed. Interventionist studies involve a deliberate imposition of physical activity with subsequent monitoring of the eating response. Correlational studies make use of naturally occurring differences in the levels of physical activity (between and within subjects) with simultaneous assessment of energy expenditure and intake. Subjects: Studies using lean, overweight, and obese men and women were included. Results: Only 19% of interventionist studies report an increase in energy intake after exercise; 65% show no change and 16% show a decrease in appetite. Of the correlational studies, approximately half show no relationship between energy expenditure and intake. These data indicate a rather loose coupling between energy expenditure and intake. A common sense view is that exercise is futile as a form of weight control because the energy deficit drives a compensatory increase in food intake. However, evidence shows that this is not generally true. One positive aspect of this is that raising energy expenditure through physical activity (or maintaining an active life style) can cause weight loss or prevent weight gain. A negative feature is that when people become sedentary after a period of high activity, food intake is not “down-regulated” to balance a reduced energy expenditure. Conclusion: Evidence suggests that a high level of physical activity can aid weight control either by improving the matching of food intake to energy expenditure (regulation) or by raising expenditure so that it is difficult for people to eat themselves into a positive energy balance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The paper compares three different methods of inclusion of current phasor measurements by phasor measurement units (PMUs) in the conventional power system state estimator. For each of the three methods, comprehensive formulation of the hybrid state estimator in the presence of conventional and PMU measurements is presented. The performance of the state estimator in the presence of conventional measurements and optimally placed PMUs is evaluated in terms of convergence characteristics and estimator accuracy. Test results on the IEEE 14-bus and IEEE 300-bus systems are analyzed to determine the best possible method of inclusion of PMU current phasor measurements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Islanded operation, protection, reclosing and arc extinguishing are some of the challenging issues related to the connection of converter interfaced distributed generators (DGs) into a distribution network. The isolation of upstream faults in grid connected mode and fault detection in islanded mode using overcurrent devices are difficult. In the event of an arc fault, all DGs must be disconnected in order to extinguish the arc. Otherwise, they will continue to feed the fault, thus sustaining the arc. However, the system reliability can be increased by maximising the DG connectivity to the system: therefore, the system protection scheme must ensure that only the faulted segment is removed from the feeder. This is true even in the case of a radial feeder as the DG can be connected at various points along the feeder. In this paper, a new relay scheme is proposed which, along with a novel current control strategy for converter interfaced DGs, can isolate permanent and temporary arc faults. The proposed protection and control scheme can even coordinate with reclosers. The results are validated through PSCAD/EMTDC simulation and MATLAB calculations.