987 resultados para Concrete Columns
Resumo:
Research has shown that fibre reinforced polymer (FRP) wraps are effective for strengthening concrete columns for increased axial and flexural load and deformation capacity, and this technique is now used around the world. The experimental study presented in this paper is focused on the mechanics of FRP confined concrete, with a particular emphasis on the influence of the unconfined concrete compressive strength on confinement effectiveness and hoop strain efficiency. An experimental programme was undertaken to study the compressive strength and stress-strain behaviour of unconfined and FRP confined concrete cylinders of different concrete strength but otherwise similar mix designs, aggregates, and constituents. This was accomplished by varying only the water-to-cement ratio during concrete mixing operations. Through the use of high-resolution digital image correlation to measure both axial and hoop strains, the observations yield insights into the mechanics of FRP confinement of concretes of similar composition but with varying unconfined concrete compressive strength.
Resumo:
The occurrence of spalling is a major factor in determining the fire resistance of concrete constructions. The apparently random occurrence of spalling has limited the development and application of fire resistance modelling for concrete structures. This Thesis describes an experimental investigation into the spalling of concrete on exposure to elevated temperatures. It has been shown that spalling may be categorised into four distinct types, aggregate spalling, corner spalling, surface spalling and explosive spalling. Aggregate spalling has been found to be a form of shear failure of aggregates local to the heated surface. The susceptibility of any particular concrete to aggregate spalling can be quantified from parameters which include the coefficients of thermal expansion of both the aggregate and the surrounding mortar, the size and thermal diffusivity of the aggregate and the rate of heating. Corner spalling, which is particularly significant for the fire resistance of concrete columns, is a result of concrete losing its tensile strength at elevated temperatures. Surface spalling is the result of excessive pore pressures within heated concrete. An empirical model has been developed to allow quantification of the pore pressures and a material failure model proposed. The dominant parameters are rate of heating, pore saturation and concrete permeability. Surface spalling may be alleviated by limiting pore pressure development and a number of methods to this end have been evaluated. Explosive spalling involves the catastrophic failure of a concrete element and may be caused by either of two distinct mechanisms. In the first instance, excessive pore pressures can cause explosive spalling, although the effect is limited principally to unloaded or relatively small specimens. A second cause of explosive spalling is where the superimposition of thermally induced stresses on applied load stresses exceed the concrete's strength.
Resumo:
As an alternative to transverse spiral or hoop steel reinforcement, fiber reinforced polymers (FRPs) were introduced to the construction industry in the 1980’s. The concept of concrete-filled FRP tube (CFFT) has raised great interest amongst researchers in the last decade. FRP tube can act as a pour form, protective jacket, and shear and flexural reinforcement for concrete. However, seismic performance of CFFT bridge substructure has not yet been fully investigated. Experimental work in this study included four two-column bent tests, several component tests and coupon tests. Four 1/6-scale bridge pier frames, consisting of a control reinforced concrete frame (RCF), glass FRP-concrete frame (GFF), carbon FRP-concrete frame (CFF), and hybrid glass/carbon FRP-concrete frame (HFF) were tested under reverse cyclic lateral loading with constant axial loads. Specimen GFF did not show any sign of cracking at a drift ratio as high as 15% with considerable loading capacity, whereas Specimen CFF showed that lowest ductility with similar load capacity as in Specimen GFF. FRP-concrete columns and pier cap beams were then cut from the pier frame specimens, and were tested again in three point flexure under monotonic loading with no axial load. The tests indicated that bonding between FRP and concrete and yielding of steel both affect the flexural strength and ductility of the components. The coupon tests were carried out to establish the tensile strength and elastic modulus of each FRP tube and the FRP mold for the pier cap beam in the two principle directions of loading. A nonlinear analytical model was developed to predict the load-deflection responses of the pier frames. The model was validated against test results. Subsequently, a parametric study was conducted with variables such as frame height to span ratio, steel reinforcement ratio, FRP tube thickness, axial force, and compressive strength of concrete. A typical bridge was also simulated under three different ground acceleration records and damping ratios. Based on the analytical damage index, the RCF bridge was most severely damaged, whereas the GFF bridge only suffered minor repairable damages. Damping ratio was shown to have a pronounced effect on FRP-concrete bridges, just the same as in conventional bridges. This research was part of a multi-university project, which is founded by the National Science Foundation (NSF) - Network for Earthquake Engineering Simulation Research (NEESR) program.
Resumo:
As an alternative to transverse spiral or hoop steel reinforcement, fiber reinforced polymers (FRPs) were introduced to the construction industry in the 1980's. The concept of concrete-filled FRP tube (CFFT) has raised great interest amongst researchers in the last decade. FRP tube can act as a pour form, protective jacket, and shear and flexural reinforcement for concrete. However, seismic performance of CFFT bridge substructure has not yet been fully investigated. Experimental work in this study included four two-column bent tests, several component tests and coupon tests. Four 1/6-scale bridge pier frames, consisting of a control reinforced concrete frame (RCF), glass FRP-concrete frame (GFF), carbon FRP-concrete frame (CFF), and hybrid glass/carbon FRP-concrete frame (HFF) were tested under reverse cyclic lateral loading with constant axial loads. Specimen GFF did not show any sign of cracking at a drift ratio as high as 15% with considerable loading capacity, whereas Specimen CFF showed that lowest ductility with similar load capacity as in Specimen GFF. FRP-concrete columns and pier cap beams were then cut from the pier frame specimens, and were tested again in three point flexure under monotonic loading with no axial load. The tests indicated that bonding between FRP and concrete and yielding of steel both affect the flexural strength and ductility of the components. The coupon tests were carried out to establish the tensile strength and elastic modulus of each FRP tube and the FRP mold for the pier cap beam in the two principle directions of loading. A nonlinear analytical model was developed to predict the load-deflection responses of the pier frames. The model was validated against test results. Subsequently, a parametric study was conducted with variables such as frame height to span ratio, steel reinforcement ratio, FRP tube thickness, axial force, and compressive strength of concrete. A typical bridge was also simulated under three different ground acceleration records and damping ratios. Based on the analytical damage index, the RCF bridge was most severely damaged, whereas the GFF bridge only suffered minor repairable damages. Damping ratio was shown to have a pronounced effect on FRP-concrete bridges, just the same as in conventional bridges. This research was part of a multi-university project, which is founded by the National Science Foundation (NSF) Network for Earthquake Engineering Simulation Research (NEESR) program.
Resumo:
Manually inspecting bridges is a time-consuming and costly task. There are over 600,000 bridges in the US, and not all of them can be inspected and maintained within the specified time frame as some state DOTs cannot afford the essential costs and manpower. This paper presents a novel method that can detect bridge concrete columns from visual data for the purpose of eventually creating an automated bridge condition assessment system. The method employs SIFT feature detection and matching to find overlapping areas among images. Affine transformation matrices are then calculated to combine images containing different segments of one column into a single image. Following that, the bridge columns are detected by identifying the boundaries in the stitched image and classifying the material within each boundary. Preliminary test results using real bridge images indicate that most columns in stitched images can be correctly detected and thus, the viability of the application of this research.
Resumo:
Manual inspection is required to determine the condition of damaged buildings after an earthquake. The lack of available inspectors, when combined with the large volume of inspection work, makes such inspection subjective and time-consuming. Completing the required inspection takes weeks to complete, which has adverse economic and societal impacts on the affected population. This paper proposes an automated framework for rapid post-earthquake building evaluation. Under the framework, the visible damage (cracks and buckling) inflicted on concrete columns is first detected. The damage properties are then measured in relation to the column's dimensions and orientation, so that the column's load bearing capacity can be approximated as a damage index. The column damage index supplemented with other building information (e.g. structural type and columns arrangement) is then used to query fragility curves of similar buildings, constructed from the analyses of existing and on-going experimental data. The query estimates the probability of the building being in different damage states. The framework is expected to automate the collection of building damage data, to provide a quantitative assessment of the building damage state, and to estimate the vulnerability of the building to collapse in the event of an aftershock. Videos and manual assessments of structures after the 2009 earthquake in Haiti are used to test the parts of the framework.
Resumo:
Post-earthquake structural safety evaluations are currently performed manually by a team of certified inspectors and/or structural engineers. This process is time-consuming and costly, keeping owners and occupants from returning to their businesses and homes. Automating these evaluations would enable faster, and potentially more consistent, relief and response processes. In order to do this, the detection of exposed reinforcing steel is of utmost significance. This paper presents a novel method of detecting exposed reinforcement in concrete columns for the purpose of advancing practices of structural and safety evaluation of buildings after earthquakes. Under this method, the binary image of the reinforcing area is first isolated using a state-of-the-art adaptive thresholding technique. Next, the ribbed regions of the reinforcement are detected by way of binary template matching. Finally, vertical and horizontal profiling are applied to the processed image in order to filter out any superfluous pixels and take into consideration the size of reinforcement bars in relation to that of the structural element within which they reside. The final result is the combined binary image disclosing only the regions containing rebar overlaid on top of the original image. The method is tested on a set of images from the January 2010 earthquake in Haiti. Preliminary test results convey that most exposed reinforcement could be properly detected in images of moderately-to-severely damaged concrete columns.
Resumo:
Este trabalho visou a demonstrar o dimensionamento e verificação de cálculo da NBR 6118 (ABNT, 2007) com as suas características geométricas, cobrimento da armadura, armaduras, flambagem e a resistência de pilares à compressão centrada dos pilares em concreto armado, apresentando na revisão bibliográfica as principais técnicas de reforço estrutural de pilares de concreto armado para edificações antigas, identificando as principais metodologias e técnicas utilizadas no Brasil e apresentando os pontos positivos e negativos de cada técnica:encamisamento de concreto, perfis metálicos, chapa de aço colado, manta/tecido de carbono, aramida e vidro e polímeros reforçados com fibras de carbono (PRFC). Os pilares com aumento da seção transversal retangular, com adição de armação e concreto, sendo mais usual e prática a técnica apresenta dificuldades em obras antigas, geralmente devido à necessidade arquitetônica de permanecer o mais fiel a sua forma original. Justificando-se a necessidade de conhecimento das diversas técnicas de reforço estrutural descritas neste trabalho com aumento de capacidade de resistência, sem que haja aumento substancial, na seção transversal dos pilares e objetivando a análise do reforço proposto através dos cálculos do projeto, programa – PDOP 2.0 e parâmetros de cálculo da NBR 6118 (ABNT, 2007). Os resultados obtidos através da análise comparativa do reforço executado no estudo de caso “revitalização do casarão” - com relação à análise dos pilares retangulares submetidos à flexão composta oblíqua, esforços cortantes e torsores quanto à NBR 6118 (ABNT, 2007) utilizando o programa para dimensionamento otimizado de pilares – PDOP 2.0 - indicaram que a técnica de reforço estudada foi eficiente, pois todas as peças reforçadas tiveram uma capacidade portante maior que a do pilar original sem o reforço.
Resumo:
Reinforced concrete columns might fail because of buckling of the longitudinal reinforcing bar when exposed to earthquake motions. Depending on the hoop stiffness and the length-over-diameter ratio, the instability can be local (in between two subsequent hoops) or global (the buckling length comprises several hoop spacings). To get insight into the topic, an extensive literary research of 19 existing models has been carried out including different approaches and assumptions which yield different results. Finite element fiberanalysis was carried out to study the local buckling behavior with varying length-over-diameter and initial imperfection-over-diameter ratios. The comparison of the analytical results with some experimental results shows good agreement before the post buckling behavior undergoes large deformation. Furthermore, different global buckling analysis cases were run considering the influence of different parameters; for certain hoop stiffnesses and length-over-diameter ratios local buckling was encountered. A parametric study yields an adimensional critical stress in function of a stiffness ratio characterized by the reinforcement configuration. Colonne in cemento armato possono collassare per via dell’instabilità dell’armatura longitudinale se sottoposte all’azione di un sisma. In funzione della rigidezza dei ferri trasversali e del rapporto lunghezza d’inflessione-diametro, l’instabilità può essere locale (fra due staffe adiacenti) o globale (la lunghezza d’instabilità comprende alcune staffe). Per introdurre alla materia, è proposta un’esauriente ricerca bibliografica di 19 modelli esistenti che include approcci e ipotesi differenti che portano a risultati distinti. Tramite un’analisi a fibre e elementi finiti si è studiata l’instabilità locale con vari rapporti lunghezza d’inflessione-diametro e imperfezione iniziale-diametro. Il confronto dei risultati analitici con quelli sperimentali mostra una buona coincidenza fino al raggiungimento di grandi spostamenti. Inoltre, il caso d’instabilità globale è stato simulato valutando l’influenza di vari parametri; per certe configurazioni di rigidezza delle staffe e lunghezza d’inflessione-diametro si hanno ottenuto casi di instabilità locale. Uno studio parametrico ha permesso di ottenere un carico critico adimensionale in funzione del rapporto di rigidezza dato dalle caratteristiche dell’armatura.
Resumo:
El presente trabajo se refiere al estudio teórico-experimental del comportamiento de pilares y vigas de hormigón armado reforzados con fibra de carbono o CFRP. El análisis se realiza considerando que los pilares se refuerzan mediante la técnica de adhesión de tejidos de fibra de carbono, generando un efecto de confinamiento. Las vigas se refuerzan mediante la incorporación de barras del mismo material, con refuerzos a cortante. El objetivo es poder comparar el estudio analítico de este tipo de refuerzos con resultados experimentales obtenidos con anterioridad a la realización de este documento, y así poder obtener conclusiones de las posibles diferencias. Hay que señalar que los modelos experimentales no forman parte de este estudio. Los ensayos en pilares fueron realizados en sección cuadrada y circular evaluando la rotura a compresión de las piezas, habiendo sido éstas escaladas con un factor de reducción de 2,3. Los ensayos correspondientes a vigas se realizaron en sección rectangular, centrándose en la evaluación de la rotura a flexión y habiendo sido escaladas igualmente, pero con un factor de reducción de 1:2. El documento se estructura en cuatro capítulos, cuyo contenido se expone de forma concisa a continuación. En el capítulo uno o marco teórico se exponen los principios de comportamiento y tipologías de los pilares y vigas de hormigón armado, las bases teóricas de su refuerzo y confinamiento, así como las diversas técnicas de refuerzo existentes. Se detalla la técnica con FRP, comparando y analizando sus ventajas e inconvenientes. En el capítulo dos se expone el proceso de fabricación, refuerzo y resultados de los modelos experimentales realizados para ambos elementos estructurales. La obtención de los modelos teóricos forma parte del capítulo tres, comparándose con los resultados experimentales en el cuarto capítulo. Finalmente, en el último capítulo se presentan las conclusiones obtenidas al realizar esta comparativa en el refuerzo de vigas y pilares con fibra de carbono. This work refers to the theoretical and experimental study of the behavior of CFRP reinforced concrete columns and beams. The analysis was done considering that the pillars are reinforced by CFRP wrapping technique, resulting in a confinement effect. The beams are reinforced by the addition of bars of the same material, with shear reinforcements. The objective is to compare the analytical study of this type of reinforcement with experimental results obtained prior to the performance of this document, and draw conclusions for any differences. Notice that experimental models are not part of this study. The tests were performed on circular and square section pillars, evaluating compression fracture of the pieces, having been scaled down with a factor of 2.3. The tests were performed on rectangular section beams, focusing on evaluation of the bending fracture and being scaled down equally, but with a factor of 1:2. The document is divided into four chapters, whose content is set out concisely below. The chapter one or theoretical framework sets out the principles of behavior and types of columns and beams of reinforced concrete, the theoretical basis of its reinforcement and confinement, as well as various existing reinforcement techniques. CFRP technique it’s detailed, comparing and analyzing their advantages and disadvantages. Chapter two describes the process of manufacture, reinforcement and results of experimental models made for both structural elements. Chapter three shows the obtaining of the theoretical models, comparing them with the experimental results in the fourth chapter. Finally, the last chapter presents the conclusions to make this comparison in the strengthening of beams and columns with carbon fiber.
Resumo:
En la actualidad muchas estructuras de hormigón armado necesitan ser reforzadas debido a diversas razones: errores en el proyecto o construcción, deterioro debido a efectos ambientales, cambios de uso o mayores requerimientos en los códigos. Los materiales compuestos, también conocidos como polímeros reforzados con fibras (FRP), están constituidos por fibras continuas de gran resistencia y rigidez embebidas en un material polimérico. Los FRP se utilizan cada vez más en aplicaciones estructurales debido a sus excelentes propiedades (elevadas resistencia y rigidez específicas y resistencia a la corrosión). Una de las aplicaciones más atractivas es el refuerzo de pilares mediante confinamiento para incrementar su resistencia y ductilidad. El confinamiento puede conseguirse pegando capas de FRP envolviendo el pilar en la dirección de los cercos (con las fibras orientadas en dirección perpendicular al eje del elemento). Se han realizado numerosos estudios experimentales en probetas cilíndricas pequeñas confinadas con encamisados de FRP y sometidas a compresión axial, y se han propuesto varios modelos sobre el hormigón confinado con FRP. Es sabido que el confinamiento de pilares de sección no circular es menos eficiente. En una sección circular, el FRP ejerce una presión de confinamiento uniforme sobre todo el perímetro, mientras que en una sección rectangular la acción de confinamiento se concentra en las esquinas. Esta tesis presenta los resultados de una investigación experimental sobre el comportamiento de probetas de hormigón de sección cuadrada confinadas con FRP y sometidas a compresión centrada. Se realizaron un total de 42 ensayos investigándose el comportamiento en las direcciones axial y transversal. Las variables del estudio incluyen: la resistencia del hormigón, el tipo de fibras (vidrio o carbono), la cuantía de refuerzo y el radio de curvatura de las esquinas. Los resultados de los ensayos realizados muestran que el confinamiento con FRP puede mejorar considerablemente la resistencia y ductilidad de pilares de hormigón armado de sección cuadrada con las esquinas redondeadas. La mejora conseguida es mayor en los hormigones de baja resistencia que en los de resistencia media. La deformación de rotura de la camisa de FRP es menor que la que se obtiene en ensayos de tracción normalizados del laminado, y la eficiencia del confinamiento depende en gran medida del radio de redondeo de las esquinas. Los resultados se han comparado con los obtenidos según los modelos teóricos más aceptados. Hay dos parámetros críticos en el ajuste de los modelos: el factor de eficiencia de la deformación y el efecto de confinamiento en secciones no circulares. Nowadays, many existing RC structures are in need of repair and strengthening for several reasons: design or construction errors, deterioration caused by environmental effects, change in use of the structures or revisions of code requirements. Composite materials, also known as fibre reinforced polymers (FRP), are composed of high strength and stiffness continuous fibres embedded in a polymer material. FRP materials are being increasingly used in many structural applications due to their excellent properties (high strength- and stiffness-toweight ratio, good corrosion behaviour). One of the most attractive applications of FRP is the confinement of concrete columns to enhance both strength and ductility. Concrete confinement can be achieved by bonding layers of hoop FRP around the column (fibres oriented perpendicular to the longitudinal axis). Many experimental studies have been conducted on small-scale plain concrete specimens of circular cross-sections confined with FRP and subjected to pure axial compressive loading, and several design models have been proposed to describe the behaviour of FRP-confined concrete. It is widely accepted that the confinement of non-circular columns is less efficient than the confinement of circular columns. In a circular cross section, the jacket exerts a uniform confining pressure over the entire perimeter. In the case of a rectangular cross section, the confining action is mostly concentrated at the corners. This thesis presents the results of a comprehensive experimental investigation on the behaviour of axially loaded square concrete specimens confined with FRP. A total of 42 compression tests were conducted, and the behaviour of the specimens in the axial and transverse directions were investigated. The parameters considered in this study are: concrete strength, type of fibres (glass or carbon), amount of FRP reinforcement and corner radius of the cross section. The tests results indicate that FRP confinement can enhance considerably the compressive strength and ductility of RC square columns with rounded corners. The enhancement is more pronounced for low- than for normal-strength concrete. The rupture strain of the FRP jacket is lower than the ultimate strain obtained by standard tensile testing of the FRP material, and the confinement efficiency significantly depends on the corner radius. The confined concrete behaviour was predicted according to the more accepted theoretical models and compared with experimental results. There are two key parameters which critically influence the fitting of the models: the strain efficiency factor and the effect of confinement in non-circular sections.
Resumo:
Neste estudo foram analisados experimentalmente o comportamento de 24 pilares curtos de Concreto de Ultra Alta Resistência - CUAR, confinados por armaduras helicoidais, avaliando especificamente os acréscimos de resistência e ductilidade obtidos com diferentes níveis de pressão lateral de confinamento. Na etapa experimental foram realizados ensaios de pilares curtos de CUAR com as seguintes características: - seção circular de 7,2 cm de diâmetro e comprimento de 23 cm, e quatro níveis de resistência à compressão do concreto sendo eles, 165, 175, 200 e 229 MPa, dosados sem e com adição de fibras metálicas; - diferentes espaçamentos das armaduras helicoidais, de modo que fossem obtidas situações com baixo, médio e alto índice de confinamento e taxa de armadura longitudinal fixa. Os ensaios de compressão centrada foram realizados com controle de deslocamento, de modo que foram obtidas as curvas força x deslocamento completas. Constatou-se que a seção resistente dos pilares de CUAR é a formada pelo núcleo de concreto confinado, área delimitada pelo eixo da armadura transversal. Observou-se que o CUAR com fibras metálicas apresenta maior deformação do núcleo de concreto confinado em relação ao núcleo de concreto confinado de CUAR sem adição de fibras metálicas, indicando dessa forma, que os pilares de CUAR com fibras metálicas apresentam comportamento mais dúctil. Para as situações de alto confinamento foram gerados ao concreto do núcleo confinado significativos acréscimos de resistência e deformação axial, aumentando a resistência do concreto confinado em relação a resistência do concreto não confinado em: 82,26%, 75,34%, 90,46% e 70,51%, respectivamente, e as deformações axiais do concreto confinado em relação a deformação axial do concreto não confinado em: 433%, 474%, 647% e 550%. Finalmente, acredita-se que os resultados obtidos poderão trazer subsídios para aplicações futuras desta técnica de confinamento na construção de novos elementos estruturais e no reforço de pilares submetidos a elevados níveis de solicitação axial.
Resumo:
Dissertação de Mestrado, Engenharia Civil, Especialização em Estruturas, Instituto Superior de Engenharia, Universidade do Algarve, 2016
Resumo:
This paper presents a detailed description of the influence of critical parameters that govern the vulnerability of columns under lateral impact loads. Numerical simulations are conducted by using the Finite Element program LS-DYNA, incorporating steel reinforcement, material models and strain rate effects. A simplified method based on impact pulse generated from full scale impact tests is used for impact reconstruction and effects of the various pulse loading parameters are investigated under low to medium velocity impacts. A constitutive material model which can simulate failures under tri-axial state of stresses is used for concrete. Confinement effects are also introduced to the numerical simulation and columns of Grade 30 to 50 concrete under pure axial loading are analysed in detail. This research confirmed that the vulnerability of the axially loaded columns can be mitigated by reducing the slenderness ratio and concrete grade, and by choosing the design option with a minimal amount of longitudinal steel. Additionally, it is evident that approximately a 50% increase in impact capacity can be gained for columns in medium rise buildings by enhancing the confinement effects alone. Results also indicated that the ductility as well as the mode of failure under impact can be changed with the volumetric ratio of lateral steel. Moreover, to increase the impact capacity of the vulnerable columns, a higher confining stress is required. The general provisions of current design codes do not sufficiently cover this aspect and hence this research will provide additional guidelines to overcome the inadequacies of code provisions.