This paper presents a combined experimental and numerical study on the behaviour of both circular and square concrete-filled steel tube (CFT) stub columns under local compression. Twelve circular and eight square CFT stub columns were tested to study their bearing capacity and the key influential parameters. A 3D finite element model was established for simulation and parametric study to investigate the structural behaviour of the stub columns. The numerical results agreed well with the experimental results. In addition, analytical formulas were proposed to calculate the load bearing capacity of CFT stub columns under local compression.
Resumo:
This paper presents a numerical study of the response of axially loaded concrete filled steel tube (CFST) columns under lateral impact loading using explicit non-linear finite element techniques. The aims of this paper are to evaluate the vulnerability of existing columns to credible impact events as well as to contribute new information towards the safe design of such vulnerable columns. The model incorporates concrete confinement, strain rate effects of steel and concrete, contact between the steel tube and concrete and dynamic relaxation for pre-loading, which is a relatively recent method for applying a pre-loading in the explicit solver. The finite element model was first verified by comparing results with existing experimental results and then employed to conduct a parametric sensitivity analysis. The effects of various structural and load parameters on the impact response of the CFST column were evaluated to identify the key controlling factors. Overall, the major parameters which influence the impact response of the column are the steel tube thickness to diameter ratio, the slenderness ratio and the impact velocity. The findings of this study will enhance the current state of knowledge in this area and can serve as a benchmark reference for future analysis and design of CFST columns under lateral impact.
Resumo:
Steel columns in frame structure always carry heavy upcoming compressive forces. As a consequence, axial shortening becomes a common phenomenon in a multistoried steel structure. A 100 storied steel structure is analyzed in SAP2000 to study the magnitude overall effects of column shortening. It was found from the study that the maximum axial shortening occurs at the columns of top storey of the steel structure and at the columns of bottom storey, the axial deformation is negligible. The increasing rate of axial shortening is significant at the initial levels. However, at the upper levels, the amount of axial shortening in steel columns differs insignificantly. In the selected rigid frame structure, the axial shortening of adjacent steel columns is found to influence significantly the differential shortening of the structure. The consequent effect of differential shortening leads to develop excessive stress in the corner joints which ultimately hamper the normal behavior of the structural systems. The results are discussed elaborately in the paper.
Resumo:
The properties of Alfven surface waves along a cylindrical plasma column surrounded by vacuum or by another plasma medium are discussed. Both symmetric (m=0) and asymmetric (m=+or-1) modes are found to be dispersive in nature. The interfacial symmetric modes propagate in a certain frequency window ( omega A1, omega As), where omega As is the Alfven surface wave frequency along the interface of two semi-infinite media; when nu A1> nu A2 these modes propagate as backward waves and when nu A1< nu A2 as forward waves. The asymmetric modes change from backward to forward waves at a critical wave number kTr approximately=1.59/a when nu A1< nu A2 or vice versa when nu A1> nu A2.
Resumo:
The dispersive and stability characteristics of Alfven surface waves (ASW) along the boundary of the moving cylindrical plasma column, surrounded by a stationary medium embedded in a parallel magnetic field is studied. The nature of the symmetric and asymmetric modes on the interface parameters is also discussed.
Resumo:
This paper presents a combined experimental, numerical, and theoretical study on the mechanical behaviors of track-shaped concrete-filled steel tubular (SCFRT) stub columns stiffened by rebars under compressive load. A total of 18 track-shaped concrete-filled steel tubular specimens including 12 specimens stiffened by rebars and 6 non-stiffened counterparts are tested, with consideration of parameters including flakiness ratio, concrete strength, and stiffeners. Failure pattern, bearing capacity, and ductility are all analyzed and discussed based on the experimental results. The numerical simulation by finite element (FE) software ABAQUS is also conducted. Based on both experimental and numerical results, theoretical formula to predict the load-bearing capacity of SCFRT stub columns subjected to axial compression loading is established according to the superposition principle of ultimate load-bearing capacity with rational simplification. The proposed theoretical method provides accurate predictions on the load bearing capacity by comparing with experimental results from 18 groups of specimens.
Resumo:
Concrete filled steel tubular (CFST) columns are increasingly used in bridge piers and high-rise buildings due to their excellent axial load bearing capacity. These columns may experience severe damage or failure due to transverse impact of vehicle collisions. In this study, numerical investigation is carried out to evaluate the effect of carbon fibre reinforced polymer (CFRP) strengthening CFST columns under vehicular impact. The CFRP composites damage mechanisms are simulated to account four different failure criteria. The cohesive elements are introduced as interface element to properly simulate the adhesively bonded regime. Simplified vehicle model is also developed to represent real vehicle behaviour. The FE analysis results show that externally bonded CFRP composites improve the impact resistance capacity compared to bare CFST column.
Resumo:
Effects of large deformation and inelasticity are considered in formulating the behavior of columns of variable cross section subjected to an axial compressive load. Simple, approximate methods are used to obtain numerical results. The combined effect of the nonlinearities is shown to be of a hardening type for small column deflections
Resumo:
S-Labeled nucleosides of E. coli tRNA and some of the derivatives of thionucleosides were separated on Bio-Gel P-2 and Sephadex G-10 columns employing buffers of low salt concentration and high pH.
Resumo:
This paper presents an experimental investigation on the lateral impact performance of axially loaded concrete-filled double-skin tube (CFDST) columns. These columns have desirable structural and constructional properties and have been used as columns in building, legs of off shore platforms and as bridge piers. Since they could be vulnerable to impact from passing vessels or vehicles, it is necessary to understand their behaviour under lateral impact loads. With this in mind, an experimental method employing an innovative instrumented horizontal impact testing system (HITS) was developed to apply lateral impact loads whilst the column maintained a static axial pre-loading to examine the failure mechanism and key response parameters of the column. These included the time histories of impact force, reaction forces, global lateral deflection and permanent local buckling profile. Eight full scale columns were tested for key parameters including the axial load level and impact location. Based on the test data, the failure mode, peak impact force, impact duration, peak reaction forces, reaction force duration, column maximum and residual global deflections and column local buckling length, depth and width under varying conditions are analysed and discussed. It is evident that the innovative HITS can successfully test structural columns under the combination of axial pre-loading and impact loading. The findings on the lateral impact response of the CFDST columns can serve as a benchmark reference for their future analysis and design.
Resumo:
This research treats the lateral impact behaviour of composite columns, which find increasing use as bridge piers and building columns. It offers (1) innovative experimental methods for testing structural columns, (2) dynamic computer simulation techniques as a viable tool in analysis and design of such columns and (3) significant new information on their performance which can be used in design. The research outcomes will enable to protect lives and properties against the risk of vehicular impacts caused either accidentally or intentionally.
Resumo:
This paper presents an experimental investigation on the lateral impact response of axially loaded concrete filled double skin tube (CFDST) columns. A total of four test series are being conducted at Queensland University of Technology using a novel horizontal impact-testing rig. The test results reported in this paper are from the first test series, where the columns are pinned at both ends and impacted at mid-span. In the next three series, effects of support conditions, impact location and repeated impact will be treated. The main objectives of the current paper are to describe the innovative testing procedure and provide some insight into the lateral impact behavior and failure of simply supported axially pre-loaded CFDST columns. The results include time histories of impact forces, reaction forces, axial force and global lateral deflection. Based on the test data, the failure mode, peak impact force, peak reaction forces, maximum deflection and residual deflection, with and without axial load, are analyzed and discussed. The findings of this study will serve as a benchmark reference for future analysis and design of CFDST columns.
Resumo:
Concrete-filled double skin tube (CFDST) is a creative innovation of steel-concrete-steel composite construction, formed by two concentric steel tubes separated by a concrete filler. Over the recent years, this column form has been widely used as a new sustainable alternative to existing structural bridge piers and building columns. Since they could be vulnerable to impact from passing vessels or vehicles, it is necessary to understand their behaviour under lateral impact loads. With this in mind, physical tests on full scale columns were performed using an innovative horizontal impact testing system to obtain the failure modes, the time history of the impact force, reaction forces and global lateral deflection as well as permanent local buckling profile of the columns. The experimental testing was complemented and supplemented by developing and using an advanced finite element analysis model. The model was validated by comparing the numerical results against experimental data. The findings of this study will serve as a benchmark reference for future analysis and design of CFDST columns.