991 resultados para Color Doppler Genuine Stress Incontinence


Relevância:

100.00% 100.00%

Publicador:

Resumo:

In a prospective study 105 patients with symptoms of stress incontinence underwent video-urodynamic testing, including resting urethral pressure profilometry and translabial ultrasound. The urethral pressure profile (UPP) included maximum urethral closure pressure (MUCP), functional length (FL) and area under the curve (AUC). Ultrasound parameters included urethral thickness, urethral rotation and bladder neck descent, as well as funneling/opening of the internal urethral meatus on Valsalva maneuver. Levator contraction strength was assessed measuring the cranioventral displacement of the internal meatus. Negative correlations between UPP data and age, parity and previous surgery were observed which were consistent with literature data. There was a positive correlation :between the urethral AP diameter on ultrasound and the MUCP, which agrees with reports showing reduced sphincter thickness or volume in stress-incontinent women. Hypermobility on ultrasound did not correlate with UPP data. However, a lower MUCP correlated with extensive opening of the bladder neck. Finally, there was a trend towards poorer pelvic floor function with lower MUCP measurements.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

International guidelines recommend a first line therapy in the treatment of female stress urinary incontinence (SUI), the pelvic floor muscle (PFM) training. This case report assesses the effects of the PFM training program in treating women with severe SUI. The urodynamic parameters allow diagnosed intrinsic sphincter deficiency and urethral hypermobility. The subjective and objective parameters were assessed at the beginning and after six-month of PFM training program. This case report confirms the efficiency of the intensive training program in severe SUI. The medical implications of the PFM training as first treatment option reflect favourable individual results and additionally contribute to the selection of the non-invasive treatment, the reduction of the incidence collateral effects, low costs and that does not prevent future treatment options.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES: The aim of this study was to evaluate right ventricular (RV) and left ventricular function and pulmonary circulation in chronic mountain sickness (CMS) patients with rest and stress echocardiography compared with healthy high-altitude (HA) dwellers. BACKGROUND: CMS or Monge's disease is defined by excessive erythrocytosis (hemoglobin >21 g/dl in males, 19 g/dl in females) and severe hypoxemia. In some cases, a moderate or severe increase in pulmonary pressure is present, suggesting a similar pathogenesis of pulmonary hypertension. METHODS: In La Paz (Bolivia, 3,600 m sea level), 46 CMS patients and 40 HA dwellers of similar age were evaluated at rest and during semisupine bicycle exercise. Pulmonary artery pressure (PAP), pulmonary vascular resistance, and cardiac function were estimated by Doppler echocardiography. RESULTS: Compared with HA dwellers, CMS patients showed RV dilation at rest (RV mid diameter: 36 ± 5 mm vs. 32 ± 4 mm, CMS vs. HA, p = 0.001) and reduced RV fractional area change both at rest (35 ± 9% vs. 43 ± 9%, p = 0.002) and during exercise (36 ± 9% vs. 43 ± 8%, CMS vs. HA, p = 0.005). The RV systolic longitudinal function (RV-S') decreased in CMS patients, whereas it increased in the control patients (p < 0.0001) at peak stress. The RV end-systolic pressure-area relationship, a load independent surrogate of RV contractility, was similar in CMS patients and HA dwellers with a significant increase in systolic PAP and pulmonary vascular resistance in CMS patients (systolic PAP: 50 ± 12 mm Hg vs. 38 ± 8 mm Hg, CMS vs. HA, p < 0.0001; pulmonary vascular resistance: 2.9 ± 1 mm Hg/min/l vs. 2.2 ± 1 mm Hg/min/l, p = 0.03). Both groups showed comparable systolic and diastolic left ventricular function both at rest and during stress. CONCLUSIONS: Comparable RV contractile reserve in CMS and HA suggests that the lower resting values of RV function in CMS may represent a physiological adaptation to chronic hypoxic conditions rather than impaired RV function. (Chronic Mountain Sickness, Systemic Vascular Function [CMS]; NCT01182792).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

La placenta ácreta es la implantación anómala de la placenta en la pared uterina. Se presenta en 0.9% de todos los embarazos; actualmente es una de las causas más importantes de morbimortalidad materna. Ecografía 2D y Doppler placentario son métodos diagnósticos de primera y segunda línea. Objetivo: Evaluar la utilidad diagnóstica de ecográfica 2D y Doppler color Placentario para diagnóstico de acretismo placentario en gestantes con factores de riesgo comparándolos con diagnóstico clínico e histopatológico; y determinar incidencia de acretismo placentario en población asistente a Clínica Universitaria Colombia. Metodología: Estudio de evaluación de tecnología diagnóstica. Entre Agosto a Noviembre de 2010 se incluyeron 53 gestantes entre 24 y 40 semanas de gestación con factores de riesgo para acretismo placentario. El desempeño diagnóstico de las pruebas se determinará por sensibilidad, especificidad, valores predictivos positivo y negativo. Las características demográficas de las pacientes y resultados neonatales se analizaron mediante proporción, media y rango. Resultados: Se determinó incidencia de acretismo placentario en 4,54% de las gestantes con presencia de factores de riesgo para esta patología. Los datos hasta el momento no nos permiten calcular valores de desempeño diagnóstico. Un caso termino en histerectomía por acretismo placentario. Conclusión: Con los datos preliminares registramos una incidencia de acretismo placentario de 1 en 22 pacientes. Revisión de literatura sustenta la necesidad de realización diagnostica prenatal que impacte en la morbimortalidad materna y fetal, haciendo necesario la evaluación diagnostica valida de herramientas como el Eco 2D y Doppler color en población a riesgo.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

La placenta ácreta es la implantación anómala de la placenta en la pared uterina. Se presenta en 0.9% de todos los embarazos; actualmente es una de las causas más importantes de morbimortalidad materna. Ecografía 2D y Doppler placentario son métodos diagnósticos de primera y segunda línea. Objetivo: Evaluar la utilidad diagnóstica de ecográfica 2D y Doppler color Placentario para diagnóstico de acretismo placentario en gestantes con factores de riesgo comparándolos con diagnóstico clínico e histopatológico; y determinar incidencia de acretismo placentario en población asistente a Clínica Universitaria Colombia. Metodología: Estudio de evaluación de tecnología diagnóstica. Entre Agosto a octubre 2011 se incluyeron 137 gestantes entre 24 y 40 semanas de gestación con factores de riesgo para acretismo placentario. El desempeño diagnóstico de las pruebas se determinará por sensibilidad, especificidad, valores predictivos positivo y negativo. Las características demográficas de las pacientes y resultados neonatales se analizaron mediante proporción, media y rango. Resultados: En un grupo de 137 pacientes con factores de riesgo de acretismo placentario analizadas se obtuvo el dato de 119 en cuanto a la finalización del embarazo. Se observaron 4 casos con diagnóstico clínico e histopatológico de acretismo placentario, evidenciando una prevalencia del 2,9%. La ecografía 2D y Doppler en la detección de acretismo placentario con un nivel de confianza del 95%, presentaron sensibilidad del 100% (IC95% 87,5-100) y especificidad de 100% (IC95% 99,6-100). Conclusión: Con los datos analizados registramos una incidencia de acretismo placentario de 4 en 132 pacientes. Revisión de literatura sustenta la necesidad de realización diagnostica prenatal que impacte en la morbimortalidad materna y fetal, haciendo necesario la evaluación diagnostica valida de herramientas como el Eco 2D y Doppler color en población a riesgo.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: False-negative interpretations of do-butamine stress echocardiography (DSE) may be associated with reduced wall stress. using measurements of contraction, we sought whether these segments were actually ischemic but unrecognized or showed normal contraction. Methods. We studied 48 patients (29 men; mean age 60 +/- 10 years) with normal regional function on the basis of standard qualitative interpretation of DSE. At coronary angiography within. 6 months of DSE, 32 were identified as having true-negative and 16 as having false-negative results of DSE. Three apical views were used to measure regional function with color Doppler tissue, integrated backscatter, and strain rate imaging. Cyclic variation of integrated backscatter was measured in 16 segments, and strain rate and peak systolic strain was calculated in 6 walls at rest and peak stress. Results. Segments with false-negative results of DSE were divided into 2 groups with and without low wall stress according to previously published cut-off values. Age, sex, left ventricular mass, left ventricular geometric pattern, and peak workload were not significantly different between patients with true and false-negative results of DSE. Importantly, no significant differences in cyclic variation and strain parameters at rest and peak stress were found among segments with true-and false-negative results of DSE with and without low wall stress. Stenosis severity had no influence on cyclic variation and strain parameters at peak stress. Conclusions: False-negative results of DSE reflect lack of ischemia rather than underinterpretation of regional left ventricular function. Quantitative markers are unlikely to increase the sensitivity of DSE.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: To evaluate the intratumoral reliability of color Doppler parameters and the contribution of Doppler sonography to the gray-scale differential diagnosis of ovarian masses. Methods: An observational study was performed including 67 patients, 15 (22.4%) with malignant ovarian neoplasm and 52 (77.6%) with benign ovarian diseases. We performed the Doppler evaluation in two distinct vessels selected after decreasing the Doppler gain to sample only vessels with higher velocity flow. Doppler measurements were obtained from each identified vessel, and resistive index (RI), pulsatility index (PI), peak systolic velocity (PSV), and end-diastolic velocity (EDV) were measured. Intraclass coefficient of correlation (ICC), sensitivity, specificity, and potential improvement in gray-scale ultrasound performance were calculated. Results: The general ICC were 0.60 (95% CI 0.42- 0.73) for RI, 0.65 (95% CI 0.49- 0.77) for PI, 0.07 (95% CI- 0.17-0.30) for PSV, and 0.19 (95% CI -0.05-0.41) for EDV. The sensitivity and specificity were respectively 84.6% and 86.7% for RI, 69.2% and 93.3% for PI, 80.0% and 65.4% for gray-scale sonography, and 93.3% and 65.4% for gray-scale plus RI (p = 0.013). Conclusions: Gynecologists must be careful in interpreting results from Doppler evaluation of ovarian masses because PSV and EDV present poor intratumoral reliability. The lower RI value, evaluated in at least two distinct sites of the tumor, was able to improve the performance of gray-scale ultrasound in differential diagnosis of ovarian masses.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background Accurate diagnosis of portal vein (PV) stenosis by real-time and color Doppler US (CD-US) after segmental liver transplantation in children can decrease morbidity by avoiding unnecessary biopsy, PV hypertension, thrombosis and loss of the graft. Objective To evaluate CD-US parameters for the prediction of PV stenosis after segmental liver transplantation in children. Materials and methods We retrospectively reviewed 61 CD-US examinations measuring the diameter at the PV anastomosis, velocities at the anastomosis (PV1) and in the segment proximal to the anastomosis (PV2), and the PV1/PV2 velocity ratio. The study group comprised patients with stenosis confirmed by angiography and the control group comprised patients with a good clinical outcome. Results PV stenosis was seen in 12 CD-US examinations. The mean PV diameter was smaller in the study group (2.6 mm versus 5.7 mm) and a PV diameter of < 3.5 mm was highly predictive of stenosis (sensitivity 100%, specificity 91.8%). Conclusion A PV diameter of < 3.5 mm is a highly predictive CD-US parameter for the detection of hemodynamically significant stenosis on angiography.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background. Regional left ventricular (LV) dysfunction may occur in patients with coronary artery disease (CAD) in the absence of infarction, but the causes of this phenomenon are unclear. We sought to identify whether changes in regional LV function were related to stenosis severity, using sensitive new ultrasound markers of function. Methods: We studied 67 individuals with no history of infarction and with normal LV systolic function: 49 patients with CAD and 18 control subjects without CAD. All patients underwent color Doppler tissue imaging, integrated backscatter (IB), anatomic M-mode echocardiography, and strain rate imaging to detect changes in structure and function. Peak early and late diastolic myocardial velocity, cyclic variation of IB, wall thickness, and percent wall thickening were measured in each basal and mid segment. Strain rate and peak systolic strain were calculated in each wall. CAD was defined as greater than or equal to 50% diameter stenosis. Normokinetic segments (n = 354) subtended by CAD were divided according to stenosis severity into 3 groups: group 1 (subtended by 50%-69% stenosis); group 2 (subtended by 70%-98% stenosis); and group 3 (subtended by greater than or equal to99% stenosis). Each parameter in each group was compared with that in 216 segments from control subjects. Results: Segments subtended by significant CAD showed lower peak early and late diastolic myocardial velocity compared with control segments. Group 3 showed significantly lower myocardial velocities than group 2 for both peak early (4.8 +/- 1.8 vs 6.0 +/- 2.0 cm/s, P

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aims: The objectives of the current study were (1) to measure type and severity of urinary leakage and (2) to investigate the association between these factors and age-related life events and conditions in three groups of Australian women with a history of urinary leakage. Methods: Five hundred participants were randomly selected from women in the young (aged 18-22 in 1996), mid-age (4550),and older (70-75) cohorts of the Australian Longitudinal Study of Women's Health (ALSWH) who had reported leaking urine in the 1996 baseline survey. Details about leaking urine (frequency, severity, situations) and associated factors (pregnancy, childbirth, body mass index [BMI]) were sought through self-report mailed follow-up surveys in 1999. Results & Conclusions: Response rates were 50, 83, and 80% in the young, mid-age, and older women, respectively. Most women confirmed that they had, leaked urine in the past month, and the majority of these were cases of mixed incontinence. Incontinence severity tended to increase with BMI for women of all ages, and increased severity scores were associated with having urine that burns or stings. Additional independent risk factors for increasing incontinence severity were heavy smoking in young women, past or present use of hormone replacement therapy in older women, and BMI and history of hysterectomy in mid-age women. (C) 2003 Wiley-Liss, Inc.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUCTION: Urinary stress incontinence affects 10% to 30% of the female population and may have a major impact on psychosocial health. In interstitial lung disease, chronic cough may lead to development of urinary incontinence, but the prevalence and impact of this symptom are unknown. OBJECTIVES: To determine the rate and impact of urinary stress incontinence among women with chronic cough due to interstitial lung disease. METHODS: 28 female patients with chronic cough secondary to interstitial lung disease and 15 controls were evaluated by questionnaires to determine the prevalence of cough-related urinary incontinence, its severity, and its impact on quality of life. RESULTS: Cough-related urinary incontinence was present in 14/28 patients with interstitial lung disease and chronic cough (50%), but in only 1/15 controls (7%, p=0.005). On a 5-points quality of life scale, the median impact of urinary incontinence was 3 (minimum=1, maximal=5), and the median impact of chronic cough was 3.5. The majority of patients (64%) believed that incontinence was a natural phenomenon due to ageing, all were ashamed by this symptom and 79% were unable to mention it to their caring physician. Only one physician had previously addressed this issue. CONCLUSION: Cough-related urinary incontinence is common in patients with interstitial lung disease and is largely overlooked. It may significantly alter quality of life. A systematic questioning by the physician would allow to promptly refer these patients for appropriate therapeutic interventions, such as perineal training.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJETIVO: Avaliar a reprodutibilidade interobservador dos índices de vascularização do Doppler de amplitude tridimensional (Doppler de amplitude 3D) no primeiro trimestre de gestação. MATERIAIS E MÉTODOS: Realizou-se estudo de reprodutibilidade com 32 gestantes normais entre 7 e 10 semanas e 6 dias. Para o cálculo do volume tridimensional dos embriões utilizou-se o método VOCAL (Virtual Organ Computer-aided AnaLysis) com ângulo de rotação de 12°. Em seguida obtiveram-se, automaticamente, os três índices vasculares do Doppler de amplitude 3D: índice de vascularização (VI), índice de fluxo (FI) e índice de vascularização e fluxo (VFI). Para o cálculo da variabilidade interobservador, um examinador realizou uma segunda medida dos 32 embriões e um segundo examinador realizou uma terceira medida dos mesmos volumes, ambos desconhecendo os resultados do outro. Utilizaram-se, para análise estatística, o coeficiente de correlação intraclasse (CCI) e gráficos de Bland-Altman. RESULTADOS: Observou-se boa reprodutibilidade interobservador dos três índices vasculares. O VI apresentou CCI = 0,9 e média da diferença = -1,1; o FI apresentou CCI = 0,9 e média da diferença = -0,5; e o VFI apresentou CCI = 0,9 e média da diferença = -1,1. CONCLUSÃO: Os índices vasculares do Doppler de amplitude 3D do embrião no primeiro trimestre de gestação foram altamente reprodutíveis, em especial o FI.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objetivo: Avaliar o efeito do tartarato de brimonidina a 0,2% tópico, instilado de 12/12 horas, na circulação retrobulbar em pacientes portadores de glaucoma. Métodos: Foram estudados os 2 olhos de 16 pacientes portadores de glaucoma primário de ângulo aberto e glaucoma crônico de ângulo estreito com iridotomia. Usando o Doppler colorido foram avaliados: velocidade sistólica máxima, velocidade diastólica final e índice de resistência das artéria central da retina, artéria ciliar posterior curta temporal e artéria oftálmica. As avaliações foram feitas antes e depois do uso da brimonidina. Resultados: O tartarato de brimonidina a 0,2% aumentou significativamente a velocidade sistólica máxima (28,24 para 34,23 cm/seg) e velocidade diastólica final (6,62 para 8,10 cm/seg) no olho direito e reduziu o índice de resistência (0,75 para 0,71) no olho esquerdo da artéria oftálmica. Conclusão: O tartarato de brimonidina 0,2% 2x/dia aumentou significativamente a velocidade sistólica máxima e velocidade diastólica final e reduziu índice de resistência da artéria oftálmica de pacientes glaucomatosos. Este efeito sugere que a brimonidina pode beneficiar pacientes glaucomatosos com insuficiência vascular na cabeça do nervo óptico.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was evaluate the renal hemodynamics of bitches with pyometra by means of laboratory tests, ultrasound B mode and Doppler, before and after treatment with ovariohysterectomy (OSH). This study evaluated 30 bitches with pyometra, all were subjected to OSH (moment 1) and 20 were evaluated after 7 days (moment 2). The renal perfusion, the resistivity index (RI) of the main renal artery and the interlobar arteries (cranial, middle and caudal) were statistically different between times 1 and 2 (p<0,05). There was no statistical difference for renal perfusion between the left and the right kidney at the time 1 and 2. The correlations between the IR of the main artery and the variables used to determine renal function were stablished at the time 1. For the correlated variables: urea, creatinine, proteinuria, ratio GGT/creatinine and protein/creatinine were curvilinear and positive associations with the resistivity index of the main renal artery (p<0,05), however these correlations were considered medium and weak. Comparing the RI of the main renal artery with different scores of dehydration and renal perfusion, there was statistical difference, and show increased of resistance renal in bitches with moderate reduction in renal perfusion as well as in dehydrated bitches. Were evaluated several features of renal morphology in ultrasound B mode, however, only the presence of pelvic dilatation, medullary signal and other changes as infarcts areas and diffuse hyperechoic spots in the renal cortical and medullary were statistically different from one moment to the other, most frequently at the time 2. The results of this study show that the Doppler ultrasound can identify changes of reduction in renal perfusion by color Doppler and the increasing of the resistivity index of the renal arteries in some bitches with pyometra. As well as, the ultrasound B mode, although has non-specific changes, can detect progressive renal disorders in bitches with pyometra.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Ginecologia, Obstetrícia e Mastologia - FMB