420 resultados para Coliforms
Resumo:
Background. Determine the presence and evolution of indicators microorganisms of water pollution in “Conde del Guadalhorce” reservoir, Málaga city, Spain. A second objective was to analyze pollution degree and evaluate the sanitary quality of bathing water and compliance with European Directive 76/160/CE. Method. A total of 120 water samples were collected in two bathing freshwater sites during May to September sampling period between 2000 to 2005, and the numbers of total coliforms (CT), faecal coliforms (CF) and faecal streptococci (EF) were enumerated using the membrane filtration method. We used the log-normal distribution method and calculate the logarithmic means, percentile points, ratios CF:EF, ANOVA and Pearson correlations. Results. Only two samples overcome CF limit values at Camping sampling station during 2000 year. Ratios CF:EF values were higher (> 4) during 2000 to 2002, and lower (< 0,7) during 2003 to 2005. Significant differences (ANOVA F = 3,41, ∝ < 0,01) was only observed with EF during evaluated period. There was no significant difference between concentration means at bathing water sites (ANOVA, F = 3,395, ∝ < 0,01). The counts of CT and CF were significantly correlated in Kiosko water samples, while in Camping water, significant correlation (t = 0,632, p < 0,05) was only observed with EF at the Camping station during 2000, 2003 and 2005 years. Conclusions. “Conde del Guadalhorce” reservoir showed hygienic conditions for safety bathing. Globally, water bathing quality is good. CT, CF y EF indicators were agreed with UE Directive during 2000- 2005, with exception CF at Camping station in 2000 year. CT y CF concentrations at Camping were frecuently higher than Kiosko, it could be caused to swimmers abundance and recreational activities. There was a trend towards rising EF, it could be caused to faecal pollution source of animal origin, needed to research it.
Resumo:
Pterotaenia fasciata is commonly recorded in rural areas in Argentina, but during a Diptera survey study developed in a reservoir which retains storm water from polluted canals in an urban area of Taboão da Serra municipality, SP, Brazil, we could capture P. fasciata adults. Enteric bacteria Escherichia coli T. Escherich, 1885 and Proteus sp. were isolated from P. fasciata collected in traps inside the reservoir and around it. Fecal coliforms and E. coli were found in the water of the reservoir. These records suggest that a high abundance of this species at urban areas with inadequate sewage canals should reveal these muscoid dipterans as mechanical vectors of enteric bacteria.
Resumo:
Se realizaron 2 evaluaciones, en agosto y noviembre-diciembre 2010, entre la desembocadura del Dren 1000 (Bodegones) y la del río Zaña. En el intermareal se registró la mayor temperatura superficial del mar, se registró anomalías de hasta +8,1°C (desembocadura del Dren 1000). En agosto en el submareal, la temperatura promedio fue 16,3 °C; en noviembre-diciembre fue 15,9 °C. Similar tendencia en superficie y fondo se observó en el oxígeno disuelto. Mayor cantidad de sólidos suspendidos totales (SST) se registró alrededor de la desembocadura del Dren 4000 (137,93 mg/L), sobrepasando los límites permisibles para aguas de CEMC y AMC. Aceites y grasas fluctuaron entre 0 y 0,3 mg/L encontrándose dentro de los límites permisibles de CEMC y AMC. En el submareal, los Coliformes Totales (CT) y coliformes Termotolerantes (CTT) cumplieron con la Ley General de Aguas para la clase V y VI; en el intermareal la demanda bioquímica de oxigeno (DBO5) en la desembocadura del Dren 3100, sobrepasó los límites permisibles de calidad de agua. En agosto se registraron 39 especies en el bentos, en noviembre y diciembre fueron 27 especies. Los índices de diversidad de Shannon Wiener y riqueza de especies del macrobentos submareal, se incrementaron de norte a sur, debido al predominio del sustrato fango-arenoso. Los puntos de alteración ambiental fueron las desembocaduras de los drenes 1000, 3100 y 4000, que reciben aguas servidas y desechos orgánicos e industriales de los centros poblados de Lambayeque, Pimentel y Santa Rosa, respectivamente.
Resumo:
Fresh basil (Ocimum basilicum L.) is used in food, phytotherapic industry, and in traditional therapeutic, due to its essential oil content and composition. Nevertheless basil can not be kept for long periods after harvest and its quality can be reduced. This work aimed to assess the influence of the season and harvest time in the postharvest conservation of basil stored for different periods. Basil was harvested at 8 am and 4 pm both in August/1999 and January/2000. Cuttings were conditioned in PVC packages and stored for 3, 6, and 9 days. During storage, chlorophyll content, essential oil content and composition were determined as well as microbiological analyses were carried out. Harvest season and the days of storage influenced the final content of essential oil. There was a linear decrease in the content of essential oil, in the chlorophyll content and in the number of mold and yeast colonies during storage. There was no effect of cropping season or harvest hour on essential oil composition, but the eugenol and linalool content increased during storage. Coliforms were under 0.3 MPN g-1 and the number of Staphylococcus aureus was under 1.0x10² UFC g-1.
Resumo:
The objective of this work was to evaluate the total and thermotolerant coliform densities in the oyster culture water of Cananeia, SP, Brazil, correlating these densities with environmental variables and tidal variations. Superficial water samples were collected in two tide conditions (spring and neap) from three areas of Cananéia municipality (Mandira, Itapitangui and Cooperostra). The three studied areas showed good conditions for the culture regarding coliform densities. The two tidal conditions differed significantly as to total coliform concentration; however, the same procedure was not performed for thermotolerant coliforms. No correlation was observed between water temperature, pH, and concentrations of total and thermotolerant coliforms. Coliform density was positively correlated with rainfall and negatively correlated with salinity. Spring and neap tides differed significantly as to coliform number. Simple diagnosis of environmental conditions of the crop fields is insufficient to assess water quality of shellfish cultivation. A continuous monitoring program of planted areas is necessary both for the assessment of water quality potential for marine culture and for ensuring safe consumption of seafood, besides constituting an important tool to understand the relationships between contamination and the involved environmental variables.
Resumo:
Free-living amoebae are distributed worldwide and are frequently in contact with humans and animals. As cysts, they can survive in very harsh conditions and resist biocides and most disinfection procedures. Several microorganisms, called amoeba-resisting microorganisms (ARMs), have evolved to survive and multiply within these protozoa. Among them are many important pathogens, such as Legionella and Mycobacteria, and also several newly discovered Chlamydia-related bacteria, such as Parachlamydia acanthamoebae, Estrella lausannensis, Simkania negevensis or Waddlia chondrophila whose pathogenic role towards human or animal is strongly suspected. Amoebae represent an evolutionary crib for their resistant microorganisms since they can exchange genetic material with other ARMs and develop virulence traits that will be further used to infect other professional phagocytes. Moreover, amoebae constitute an ideal tool to isolate strict intracellular microorganisms from complex microbiota, since they will feed on other fast-growing bacteria, such as coliforms potentially present in the investigated samples. The paradigm that ARMs are likely resistant to macrophages, another phagocytic cell, and that they are likely virulent towards humans and animals is only partially true. Indeed, we provide examples of the Chlamydiales order that challenge this assumption and suggest that the ability to multiply in protozoa does not strictly correlate with pathogenicity and that we should rather use the ability to replicate in multiple and diverse eukaryotic cells as an indirect marker of virulence towards mammals. Thus, cell-culture-based microbial culturomics should be used in the future to try to discover new pathogenic bacterial species.
Resumo:
Ozonation tests with and without prior filtration by means of a 50 micron mesh cartridge filter were conducted with primary sanitary effluents. Filtration led to increased inactivation efficiencies with regard to total and thermotolerant coliforms but it did not seem to influence heterotrophic plate count (HPC) bacteria inactivation efficiencies significantly. Application of the Chick-Watson model to experimental data obtained in the situation of constant inactivation showed that the ozone dosage was more important to bacterial inactivation than the contact time with regard to the cases of thermotolerant coliform inactivation in filtered samples and HPC bacteria and total coliform inactivation in non-filtered samples.
Resumo:
Water treatment uses chlorine for disinfection causing formation of trihalomethanes. In this work, an electrolytic water pre-treatment was studied and applied to the water from a fountainhead. The action against microorganisms was evaluated using cast-iron and aluminum electrodes. Assays were made in laboratory using the electrolytic treatment. After 5 min of electrolysis the heterotrophic bacteria count was below 500 cfu/mL and complete elimination of total and fecal coliforms was observed. Using electrolytic treatment as a pretreatment of conventional tap water treatment is proposed.
Resumo:
Physico-chemical and microbiological parameters were evaluated before and after applying an electrolytic process to effluents of a stabilization lagoon, in the presence or absence of "salt". Chlorine generation and bactericidal properties of the treatments were studied following two experiments. Effluent pH increased with electrolysis time. In the absence of "salt", 20 min electrolysis resulted in a COD (Chemical Oxygen Demand) reduction of 44%, along with ca. 99.9% (3 log10 cfu/mL) reduction in total coliforms, heterotrophic bacteria and Escherichia coli. These results indicated that the electrolytic process is a promising complementary technology to improve effluent quality for stabilization lagoons.
Resumo:
In this work, TiO2 photocatalysis was used to disinfect domestic wastewaters previously treated by different biological treatment systems: Upward-flow Anaerobic Sludge Blanket (UASB), facultative pond, and duckweed pond. The microorganisms monitored were E. coli, total coliforms, Shigella species, and Salmonella species. Photocatalytic experiments were carried out using two light sources: a solar simulator (UV intensity: 68-70 W m-2) and black-light lamps (BLL UV intensity: 17-20 W m-2). Samples were taken after each treatment stage. Results indicate that bacterial photocatalytic inactivation is affected by characteristics of the effluent, including turbidity, concentration of organic matter, and bacterial concentration, which depend of the type of biological pretreatment previously used.
Resumo:
The use of biodigester for basic and environmental sanitation has large demand in Brazil. A biodigester was built to treat conjunctly the human and pig feces and urine, regarding to its future application in rural small towns. The results show that the biodigester can reduce 90% of COD and BOD and, up to 99.99% of thermotolerant coliforms. The treated effluent has variable quantities of macro- and micro-nutrients; and organic matter. However, the concentration variability of the nutrients makes difficult a dosed application into soil. The soluble salts (mainly as Na+ form) make necessary a controlled use to avoid environmental degradation.
Resumo:
We evaluated the effect of thermal drying (60 to 75 ºC and times from 0 to 12.58 h) and alkaline treatment (Ca(OH)2 and CaO at doses from 8 to 10%.) on the microbiological and chemical characteristics of biosolids from the Cañaveralejo WWTP. The results showed that in thermal drying all temperatures studied were sufficient to achieve the sanitation of biosolids. In the alkaline treatment the two types of lime showed the total elimination of fecal coliforms, E. coli and helminth eggs, however, the process of alkalization of biosolids had significant influences on organic carbon and calcium.
Resumo:
The aim of this study was to identify, by multivariate statistical technique, the physic, chemical and biological variables that best characterize the quality of surface waters in two small rural catchments with different land uses (eucalyptus silviculture (SC) vs. pasture and extensive livestock (LC)) located in Rosário do Sul, RS - Brazil. Monitoring was conducted during the months of August 2011 to August 2012 and the following parameters were analyzed: Ca2+, Mg2+, K+, SO42-, Cl-, pH, electrical conductivity, turbidity, alkalinity, suspended and dissolved solids, biochemical oxygen demand , total coliforms, Escherichia coli and temperature, flow and rainfall. Through the use of FA/PCA, it was found that the model best fit to express water quality of in LC that was composed of five factors which account for 83.5% of the total variance, while for SC, four factors accounted for 85.12% of the variance. In LC, the five main factors were, respectively, soluble salts, diffuse pollution, solid, and both anthropogenic and organic factors. In SC, the four factors were namely: soluble salts, mineral, nutritional and diffuse pollution factors. The results of this study showed that by replacing the traditional soil usage (pasture and livestock) with planted forest, diffuse pollution was attenuated but, however, it did not result in major changes in the physical-chemical and biological characteristics of the water. Another point to note is that factorial analysis did not result in a large reduction in the number of variables, once the best model fit occurred with the addition of 15 of 18 analyzed variables (LC) and 17 of 18 analyzed variables (SC).
Resumo:
The objective of this study consisted on mapping the use and soil occupation and evaluation of the quality of irrigation water used in Salto do Lontra, in the state of Paraná, Brazil. Images of the satellite SPOT-5 were used to perform the supervised classification of the Maximum Likelihood algorithm - MAXVER, and the water quality parameters analyzed were pH, EC, HCO3-, Cl-, PO4(3-), NO3-, turbidity, temperature and thermotolerant coliforms in two distinct rainfall periods. The water quality data were subjected to statistical analysis by the techniques of PCA and FA, to identify the most relevant variables in assessing the quality of irrigation water. The characterization of soil use and occupation by the classifier MAXVER allowed the identification of the following classes: crops, bare soil/stubble, forests and urban area. The PCA technique applied to irrigation water quality data explained 53.27% of the variation in water quality among the sampled points. Nitrate, thermotolerant coliforms, temperature, electrical conductivity and bicarbonate were the parameters that best explained the spatial variation of water quality.
Resumo:
In this work it was evaluated the performance of two systems of swine wastewater treatment consisting of two-stage upflow anaerobic sludge blanket (UASB) reactors, with and without post-treatment in sequencing batch reactor (SBR), fed continuously, with aerobic phase. The UASB reactors in the first stage had 908 L in the sets I and II, and in the second stage 350 and 188 L, respectively. In the set II the post-treatment was performed in a SBR of 3,000 L. The hydraulic detention times in the anaerobic treatment systems were 100, 75 and 58 h in the set I; 87, 65 and 51 h in the set II; and 240 and 180 h in the SBR. The volumetric organic load applied in the first stage UASB reactors ranged from 6.9 to 12.6 g total COD (L d)-1 in the set I and 7.5 to 9.8 g total COD (L d)-1 in the set II. The average removal efficiencies of total COD, total phosphorus (Ptotal), and Kjeldahl and organic nitrogen (KN and Norg) in the anaerobic treatment systems were similar and reached maximum values of 97%, 64%, 68%, and 98%. In the SBR, the removal efficiencies of total COD and thermotolerant coliforms were up to 62 and 92% resulting, respectively, in effluent concentrations of 135 mg L-1 and 2x10(4)MPN (100 mL)-1. For Ptotal, total nitrogen (TN) and Norg, the average removal efficiencies in the SBR were up to 58, 25 and 73%, respectively.