974 resultados para Charge Coupled Device (ccd)


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A recirculating charge-coupled device structure has been devised. Entrance and exit gates allow a signal to be admitted, recirculated a given number of times, and then examined. In this way a small device permits simulation of a very long shift register without passing the signal through input and output diffusions. An oscilloscope motion picture demonstrating degradation of an actual circulating signal has been made. The performance of the device in simulating degradation of a signal by a very long shift register is well fit by a simple model based on transfer inefficiency.

Electrical properties of the mercury selenide on n-type chemically-cleaned silicon Schottky barrier have been studied. Barrier heights measured were 0.96 volts for the photoresponse technique and 0.90 volts for the current-voltage technique. These are the highest barriers yet reported on n-type silicon.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Electron multiplication charge-coupled devices (EMCCD) are widely used for photon counting experiments and measurements of low intensity light sources, and are extensively employed in biological fluorescence imaging applications. These devices have a complex statistical behaviour that is often not fully considered in the analysis of EMCCD data. Robust and optimal analysis of EMCCD images requires an understanding of their noise properties, in particular to exploit fully the advantages of Bayesian and maximum-likelihood analysis techniques, whose value is increasingly recognised in biological imaging for obtaining robust quantitative measurements from challenging data. To improve our own EMCCD analysis and as an effort to aid that of the wider bioimaging community, we present, explain and discuss a detailed physical model for EMCCD noise properties, giving a likelihood function for image counts in each pixel for a given incident intensity, and we explain how to measure the parameters for this model from various calibration images. © 2013 Hirsch et al.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

在2×1.7串列加速器上,利用装有CCD的Spectrapro-500i光谱单色仪的测量装置,采用束-箔方法,在2 MeV束能下研究350-450 nm波长范围的离化态氧原子光谱。本文报道在350-450 nm范围已确定的182条光谱线,这些谱线大都属于O II到O IV原子的n、1能级间的跃迁的弱谱线。实验结果与现有的一些理论一致。实验发现,有28条谱线在以前的文献中没有报道。

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Hydrocarbon nanoparticles with diameters between 10 and 30 nanometres are created in a low pressure plasma combining capacitive and inductive power coupling. The particles are generated in the capacitive phase of the experiment and stay confined in the plasma in the inductive phase. The presence of these embedded particles induces a rotation of a particle-free region (void) around the symmetry axis of the reactor. The phenomenon is analysed using optical emission spectroscopy both line integrated and spatially resolved via an intensified charge coupled device camera. From these data, electron temperatures and densities are deduced. We find that the rotation of the void is driven by a tangential component of the ion drag force induced by an external static magnetic field. Two modes are observed: a fast rotation of the void in the direction opposite to that of the tangential component and a slow rotation in the same direction. The rotation speed decreases linearly with the size of the particles. In the fast mode the dependence on the applied magnetic field is weak and consequently the rotation speed can serve as a monitor to detect particle sizes in low temperature plasmas.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Toll-like receptor-2 (TLR2) mediates host responses to gram-positive bacterial wall components. TLR2 function was investigated in a murine Streptococcus pneumoniae meningitis model in wild-type (wt) and TLR2-deficient (TLR2(-/-)) mice. TLR2(-/-) mice showed earlier time of death than wt mice (P<.02). Plasma interleukin-6 levels and bacterial numbers in blood and peripheral organs were similar for both strains. With ceftriaxone therapy, none of the wt but 27% of the TLR2(-/-) mice died (P<.04). Beyond 3 hours after infection, TLR2(-/-) mice had higher bacterial loads in brain than did wt mice, as assessed with luciferase-tagged S. pneumoniae by means of a Xenogen-CCD (charge-coupled device) camera. After 24 h, tumor necrosis factor activity was higher in cerebrospinal fluid of TLR2(-/-) than wt mice (P<.05) and was related to increased blood-brain barrier permeability (Evans blue staining, P<.02). In conclusion, the lack of TLR2 was associated with earlier death from meningitis, which was not due to sepsis but to reduced brain bacterial clearing, followed by increased intrathecal inflammation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The palette of fluorescent proteins (FPs) has grown exponentially over the past decade, and as a result, live imaging of cells expressing fluorescently tagged proteins is becoming more and more mainstream. Spinning disk confocal (SDC) microscopy is a high-speed optical sectioning technique and a method of choice to observe and analyze intracellular FP dynamics at high spatial and temporal resolution. In an SDC system, a rapidly rotating pinhole disk generates thousands of points of light that scan the specimen simultaneously, which allows direct capture of the confocal image with low-noise scientific grade-cooled charge-coupled device cameras, and can achieve frame rates of up to 1000 frames per second. In this chapter, we describe important components of a state-of-the-art spinning disk system optimized for live cell microscopy and provide a rationale for specific design choices. We also give guidelines of how other imaging techniques such as total internal reflection microscopy or spatially controlled photoactivation can be coupled with SDC imaging and provide a short protocol on how to generate cell lines stably expressing fluorescently tagged proteins by lentivirus-mediated transduction.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Recent decreases in costs, and improvements in performance, of silicon array detectors open a range of potential applications of relevance to plant physiologists, associated with spectral analysis in the visible and short-wave near infra-red (far-red) spectrum. The performance characteristics of three commercially available ‘miniature’ spectrometers based on silicon array detectors operating in the 650–1050-nm spectral region (MMS1 from Zeiss, S2000 from Ocean Optics, and FICS from Oriel, operated with a Larry detector) were compared with respect to the application of non-invasive prediction of sugar content of fruit using near infra-red spectroscopy (NIRS). The FICS–Larry gave the best wavelength resolution; however, the narrow slit and small pixel size of the charge-coupled device detector resulted in a very low sensitivity, and this instrumentation was not considered further. Wavelength resolution was poor with the MMS1 relative to the S2000 (e.g. full width at half maximum of the 912 nm Hg peak, 13 and 2 nm for the MMS1 and S2000, respectively), but the large pixel height of the array used in the MMS1 gave it sensitivity comparable to the S2000. The signal-to-signal standard error ratio of spectra was greater by an order of magnitude with the MMS1, relative to the S2000, at both near saturation and low light levels. Calibrations were developed using reflectance spectra of filter paper soaked in range of concentrations (0–20% w/v) of sucrose, using a modified partial least squares procedure. Calibrations developed with the MMS1 were superior to those developed using the S2000 (e.g. coefficient of correlation of 0.90 and 0.62, and standard error of cross-validation of 1.9 and 5.4%, respectively), indicating the importance of high signal to noise ratio over wavelength resolution to calibration accuracy. The design of a bench top assembly using the MMS1 for the non-invasive assessment of mesocarp sugar content of (intact) melon fruit is reported in terms of light source and angle between detector and light source, and optimisation of math treatment (derivative condition and smoothing function).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To assess the effect of ultrasound modulation of near infrared (NIR) light on the quantification of scattering coefficient in tissue-mimicking biological phantoms.Methods: A unique method to estimate the phase of the modulated NIR light making use of only time averaged intensity measurements using a charge coupled device camera is used in this investigation. These experimental measurements from tissue-mimicking biological phantoms are used to estimate the differential pathlength, in turn leading to estimation of optical scattering coefficient. A Monte-Carlo model base numerical estimation of phase in lieu of ultrasound modulation is performed to verify the experimental results. Results: The results indicate that the ultrasound modulation of NIR light enhances the effective scattering coefficient. The observed effective scattering coefficient enhancement in tissue-mimicking viscoelastic phantoms increases with increasing ultrasound drive voltage. The same trend is noticed as the ultrasound modulation frequency approaches the natural vibration frequency of the phantom material. The contrast enhancement is less for the stiffer (larger storage modulus) tissue, mimicking tumor necrotic core, compared to the normal tissue. Conclusions: The ultrasound modulation of the insonified region leads to an increase in the effective number of scattering events experienced by NIR light, increasing the measured phase, causing the enhancement in the effective scattering coefficient. The ultrasound modulation of NIR light could provide better estimation of scattering coefficient. The observed local enhancement of the effective scattering coefficient, in the ultrasound focal region, is validated using both experimental measurements and Monte-Carlo simulations. (C) 2010 American Association of Physicists in Medicine. [DOI: 10.1118/1.3456441]

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A new technique based on luminescent molecular sensors is utilized in these series of experiments for measurement of temperatures in material removal processes. 2-Dimensional machining of metals at low speeds and surface grinding configurations are used as the model experimental systems to understand the efficacy of this experimental technique. The experiments were conducted with a series of luminescent sensors and binder combinations for the temperature measurement. The luminescence of the sensor was measured through a charge-coupled device imaging camera, and intensive calibration exercises were performed on these sensors. Excellent agreement in the temperature fields measured through this new experimental approach and traditional infrared thermography is seen here. This technique offers the unique capability of allowing measurement of temperatures in the presence of a lubricant, akin to manufacturing conditions in situ. Extension of the technique to measure the temperature field at the tool-chip contact is described.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

K alpha radiation generated by interaction of an ultrashort (1 ps) laser with thin (25 mu m) Ti foils at high intensity (2x10(16) W/cm(2)) is analyzed using data from a spherical Bragg crystal imager and a single hit charge-coupled device spectrometer together with Monte Carlo simulations of K alpha brightness. Laser to K alpha and electron conversion efficiencies have been determined. We have also measured an effective crystal reflectivity of 3.75 +/- 2%. Comparison of imager data with data from the relatively broadband single hit spectrometer has revealed a reduction in crystal collection efficiency for high K alpha yield. This is attributed to a shift in the K-shell spectrum due to Ti ionization. (c) 2005 American Institute of Physics.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We measure the two-dimensional, near-field spatial distribution of a 140-Angstrom nickel-like silver x-ray laser at the output aperture with high magnification using a curved multilayer x-ray mirror to image the output onto an x-ray charge-coupled device camera. Lasing is created by illuminating silver slab targets with a pair of 75 ps laser pulses separated by 2.2 nsec from the Vulcan laser. The two-dimensional, high-resolution, spatial image shows the x-ray laser source size and its position relative to the target surface. A dramatic change in both the position and source size are observed for the refraction compensating curved target as compared with the flat targets.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Un nouveau contrôleur de EMCCD (Electron multiplying Charge Coupled Device) est présenté. Il permet de diminuer significativement le bruit qui domine lorsque la puce EMCCD est utilisé pour du comptage de photons: le bruit d'injection de charge. À l'aide de ce contrôleur, une caméra EMCCD scientifique a été construite, caractérisée en laboratoire et testée à l'observatoire du mont Mégantic. Cette nouvelle caméra permet, entre autres, de réaliser des observations de la cinématique des galaxies par spectroscopie de champ intégral par interférométrie de Fabry-Perot en lumière Ha beaucoup plus rapidement, ou de galaxies de plus faible luminosité, que les caméras à comptage de photon basées sur des tubes amplificateurs. Le temps d'intégration nécessaire à l'obtention d'un rapport signal sur bruit donné est environ 4 fois moindre qu'avec les anciennes caméras. Les applications d'un tel appareil d'imagerie sont nombreuses: photométrie rapide et faible flux, spectroscopie à haute résolution spectrale et temporelle, imagerie limitée par la diffraction à partir de télescopes terrestres (lucky imaging), etc. D'un point de vue technique, la caméra est dominée par le bruit de Poisson pour les flux lumineux supérieurs à 0.002 photon/pixel/image. D'un autre côté, la raie d'hydrogène neutre (HI) à 21 cm a souvent été utilisée pour étudier la cinématique des galaxies. L'hydrogène neutre a l'avantage de se retrouver en quantité détectable au-delà du disque optique des galaxies. Cependant, la résolution spatiale de ces observations est moindre que leurs équivalents réalisés en lumière visible. Lors de la comparaison des données HI, avec des données à plus haute résolution, certaines différences étaient simplement attribuées à la faible résolution des observations HI. Le projet THINGS (The HI Nearby Galaxy Survey a observé plusieurs galaxies de l'échantillon SINGS (Spitzer Infrared Nearby Galaxies Survey). Les données cinématiques du projet THIGNS seront comparées aux données cinématiques obtenues en lumière Ha, afin de déterminer si la seule différence de résolution spatiale peut expliquer les différences observées. Les résultats montrent que des différences intrinsèques aux traceurs utilisées (hydrogène neutre ou ionisé), sont responsables de dissemblances importantes. La compréhension de ces particularités est importante: la distribution de la matière sombre, dérivée de la rotation des galaxies, est un test de certains modèles cosmologiques.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective. Pixel intensity values (PI) and fractal dimensions (FD) were compared in selected mandibular regions on digital panoramic images of normal, osteopenic, and osteoporotic perimenopausal and postmenopausal women to evaluate their relative efficacies in detecting osteoporotic-associated bone density changes.Study design. Standardized mandibular angle, body, and canine/premolar (C/PM) regions on 54 charge-coupied device (CCD) digital panoramic images of normal and potentially osteoporotic postmenopausal women were analyzed for PI and FD. Lumbar spine and femoral neck dual-energy x-ray absorptiometry QXA) on each patient served as the reference standard examination. Pearson correlation coefficients and analysis of variance (ANOVA) were performed.Results. There was significant correlation among PI measurements (P < 0.01), and no significant correlation between FD. C/PM had significantly lower PI than control C/PM (P = 0.049).Conclusions. Osteoporotic changes in mandibular C/PM cancellous bone were detected in our study population on CCD digital panoramic images by using a robust image analysis paradigm. Future automated application of such image analysis could enable widespread, cost effective screening for osteoporosis in dental settings.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this article was to compare the mean value of optical density of four porcelains commonly used for fabrication of inlay/ onlay prostheses using direct digital radiograph. The sample consisted of 20 2-mm thick porcelain specimens (measured by digital pachymeter): Empress (Ivoclair), Simbios (Degussa), Vita Omega 900 and Vitadur Alpha (Vita Zahnfabrik). The values of optical density of the specimens were expressed in millimeters aluminum equivalent (mm eq Al). The samples were X-rayed using two charge coupled devices (CCD) - RVG (Trophy) - Visualix (Gendex) and a phosphor plate system - Digora (Soredex). The optical density reading was performed with Image Tool 1.28 in a total of 110 measurements. Statistical analysis showed that there were statistically significant differences in all materials studied (p < 0.05) regardless of the radiographic system used. The highest optical density value was found for Omega 900 (1.8988 mmeqAl - Visualix - Gendex) and the lowest for Vitadur Alpha (0.8647 - Visualix - Gendex). Thus, the material presenting the highest degree of optical density was Omega 900, Empress and Simbios presented intermediate optical density values, Vitadur Alpha presented the lowest value, and the optical density of porcelains was not influenced by the digital radiography systems.