Luminescent Molecular Sensors for Assessment of Temperature Field in Machining


Autoria(s): Murthy, Tejas G; Madariaga, Jon; Huang, Chih-Yung
Data(s)

2014

Resumo

A new technique based on luminescent molecular sensors is utilized in these series of experiments for measurement of temperatures in material removal processes. 2-Dimensional machining of metals at low speeds and surface grinding configurations are used as the model experimental systems to understand the efficacy of this experimental technique. The experiments were conducted with a series of luminescent sensors and binder combinations for the temperature measurement. The luminescence of the sensor was measured through a charge-coupled device imaging camera, and intensive calibration exercises were performed on these sensors. Excellent agreement in the temperature fields measured through this new experimental approach and traditional infrared thermography is seen here. This technique offers the unique capability of allowing measurement of temperatures in the presence of a lubricant, akin to manufacturing conditions in situ. Extension of the technique to measure the temperature field at the tool-chip contact is described.

Formato

application/pdf

Identificador

http://eprints.iisc.ernet.in/49092/1/tri_let_54-2_129_2014.pdf

Murthy, Tejas G and Madariaga, Jon and Huang, Chih-Yung (2014) Luminescent Molecular Sensors for Assessment of Temperature Field in Machining. In: TRIBOLOGY LETTERS, 54 (2). pp. 129-137.

Publicador

SPRINGER/PLENUM PUBLISHERS

Relação

http://dx.doi.org/10.1007/s11249-014-0317-0

http://eprints.iisc.ernet.in/49092/

Palavras-Chave #Civil Engineering
Tipo

Journal Article

PeerReviewed