In May 2013, the European Commission received a mandate from the European Council to “to present an analysis of the composition and drivers of energy prices and costs in Member States, with a particular focus on the impact on households, SMEs and energy intensive industries, and looking more widely at the EU's competitiveness vis-à-vis its global economic counterparts”. Following such mandate and in view of the preparation by the Commission of a Communication and a Staff Working Document, DG Enterprise and Industry commissioned CEPS to carry out a set of studies aimed at providing well-grounded evidence about the evolution and composition of energy prices and costs at plant level within individual industry sectors. A team of CEPS researchers conducted the research, led by Christian Egenhofer and Lorna Schrefler. Vasileios Rizos served as Project Coordinator. Other CEPS researchers contributing to the project included: Fabio Genoese, Andrea Renda, Andrei Marcu, Julian Wieczorkiewicz, Susanna Roth, Federico Infelise, Giacomo Luchetta, Lorenzo Colantoni, Wijnand Stoefs, Jacopo Timini and Felice Simonelli. In addition to an introductory report entitled “About the Study and Cross-Sectoral Analysis”, CEPS prepared five sectoral case studies: two on ceramics (wall and floor tiles and bricks and roof tiles), two on chemicals (ammonia and chlorine) and one on flat glass. Each of these six studies has been consolidated in this single volume for free downloading on the CEPS website. The specific objective was to complement information already available at macro level with a bottom-up perspective on the operating conditions that industry stakeholders need to deal with, in terms of energy prices and costs. The approach chosen was based on case studies for a selected set (sub-)sectors amongst energy-intensive industries. A standard questionnaire was circulated and respondents were sampled according to specified criteria. Data and information collected were finally presented in a structured format in order to guarantee comparability of results between the different (sub-)sectors analysed. The complete set of files can also be downloaded from the European Commission’s website: http://ec.europa.eu/enterprise/newsroom/cf/itemdetail.cfm?item_id=7238&lang=en&title=Study-on-composition-and-drivers-of-energy-prices-and-costs-in-energy-intnsive-industries The results of the studies were presented at a CEPS Conference held on February 26th along with additional evidence from other similar studies. The presentations can be downloaded at: http://www.ceps.eu/event/level-and-drivers-eu-energy-prices-energy-inten...

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Hurricane is one of the most destructive and costly natural hazard to the built environment and its impact on low-rise buildings, particularity, is beyond acceptable. The major objective of this research was to perform a parametric evaluation of internal pressure (IP) for wind-resistant design of low-rise buildings and wind-driven natural ventilation applications. For this purpose, a multi-scale experimental, i.e. full-scale at Wall of Wind (WoW) and small-scale at Boundary Layer Wind Tunnel (BLWT), and a Computational Fluid Dynamics (CFD) approach was adopted. This provided new capability to assess wind pressures realistically on internal volumes ranging from small spaces formed between roof tiles and its deck to attic to room partitions. Effects of sudden breaching, existing dominant openings on building envelopes as well as compartmentalization of building interior on the IP were systematically investigated. Results of this research indicated: (i) for sudden breaching of dominant openings, the transient overshooting response was lower than the subsequent steady state peak IP and internal volume correction for low-wind-speed testing facilities was necessary. For example a building without volume correction experienced a response four times faster and exhibited 30–40% lower mean and peak IP; (ii) for existing openings, vent openings uniformly distributed along the roof alleviated, whereas one sided openings aggravated the IP; (iii) larger dominant openings exhibited a higher IP on the building envelope, and an off-center opening on the wall exhibited (30–40%) higher IP than center located openings; (iv) compartmentalization amplified the intensity of IP and; (v) significant underneath pressure was measured for field tiles, warranting its consideration during net pressure evaluations. The study aimed at wind driven natural ventilation indicated: (i) the IP due to cross ventilation was 1.5 to 2.5 times higher for Ainlet/Aoutlet>1 compared to cases where Ainlet/Aoutlet<1, this in effect reduced the mixing of air inside the building and hence the ventilation effectiveness; (ii) the presence of multi-room partitioning increased the pressure differential and consequently the air exchange rate. Overall good agreement was found between the observed large-scale, small-scale and CFD based IP responses. Comparisons with ASCE 7-10 consistently demonstrated that the code underestimated peak positive and suction IP.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Brazil is a great ceramic raw materials productor because of the its big number of clay deposits, in various areas of the ceramic industry. Although, the majority of the natural reservations are unknown or not studied yet, so there is no scientific technical dates that can guide their usage and industrial application, as well as the racional and optimazed way of usage by the industrial sector. The state of Maranhão has a gigant mineral wealth as esmectite, bentonite, kaolin, clays, feldspates, marine salt, iron and others, but produce only products with small agregated value compared to the porcelanato, one of the most expensives ceramic cover tiles, the reason for that is the low water absorption (lower than 0,5%), beside present amazing tecnicals features, like mechanical resistence. The main objective of the work is to do the characterization of four clays, with the finallity of find an application by the results and develop formulations to produce porcelanato using these raw materials from Timon-MA. For this were made the raw materials characterization using X ray fluorecence; X ray diffraction; Differencial thermal analysis; Dilatometric analysis and Tecnological properties, planing three formulations that were sinterized at six different temperatures: 1150, 1170, 1190, 1210, 1230 and 1250ºC for 7 minutes. After the sinteratization, the samples were submitted to tension resistance analysis. Were attained two formulations with the requested properties to produce porcelanato

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Extractivism mineral is considered an activity highly degrading, due to the large volume of material that he moves in the form of ore and residues. The vast majority of mining companies do not show any technology or economically viable application that will allow the recycling of mineral residue, these being launched in areas receiving located the "open skies" degrade the environment. In Rio Grande do Norte to the production of ceramic red restricts their activities to the production of products such as: solid bricks, ceramic blocks, tiles, among others. Seeking to unite experiences and technical information that favor sustainable development, with important benefits to the construction sector and civil society in general, the present work studies the incorporation of the residue of scheelite in ceramic matrix kaolinitic, coming from the municipality of Boa Saúde - RN, in percentage of 5 %, 10 %, 20 %, 30% 40% and 50 %, by evaluating its microstructure, physical properties and formulation. The raw materials were characterized through the trials of X ray fluorescence, Diffraction of X rays, Differential Thermal Analysis and Termogravimetric Analysis. The samples were formed and fired at temperatures of 850o, 900o, 1000o, 1050o, 1100o, 1150o and 1200 oC, with isotherm of 1 hour and heating rate of 10 oC/min. Assays were performed technological of loss to fire, Water Absorption, Apparent Porosity, Apparent Density, Mass Loss in Fire and Bending Resistance; in addition to the Scanning Electron Microscopy, analyzing their physical and mechanical properties. The use of residue of scheelite in ceramic mass kaolinitic provided a final product with technological properties that meet the technical standards for the production of bricks and roofing tiles, with the percentage of 20% of waste that showed the best results

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The present study was conducted at the Department of Rural Engineering and the Department of Animal Morphology and Physiology of FCAV/Unesp, Jaboticabal, SP, Brazil. The objective was to verify the influence of roof slope, exposure and roofing material on the internal temperature of reduced models of animal production facilities. For the development of the research, 48 reduced and dissemble models with dimensions 1.00 × 1.00 × 0.50 m were used. The roof was shed-type, and the models faced to the North or South directions, with 24 models for each side of exposure. Ceramic, galvanized-steel and fibro tiles were used to build the roofs. Slopes varied between 20, 30, 40 and 50% for the ceramic tile and 10, 30, 40 and 50% for the other two. Inside the models, temperature readings were performed at every hour, for 12 months. The results were evaluated in a general linear model in a nested 3 × 4 × 2 factorial arrangement, in which the effects of roofing material and exposure were nested on the factor Slope. Means were compared by the Tukey test at 5% of probability. After analyzing the data, we observed that with the increase in the slope and exposure to the South, there was a drop in the internal temperature within the model at the geographic coordinates of Jaboticabal city (SP/Brazil).

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A method for quantitative mineralogical analysis by ATR-FTIR has been developed. The method relies on the use of the main band of calcite as a reference for the normalization of the IR spectrum of a mineral sample. In this way, the molar absorptivity coefficient in the Lambert–Beer law and the components of a mixture in mole percentage can be calculated. The GAMS equation modeling environment and the NLP solver CONOPT (©ARKI Consulting and Development) were used to correlate the experimental data in the samples considered. Mixtures of different minerals and gypsum were used in order to measure the minimum band intensity that must be considered for calculations and the detection limit. Accordingly, bands of intensity lower than 0.01 were discarded. The detection limit for gypsum was about 7% (mol/total mole). Good agreement was obtained when this FTIR method was applied to ceramic tiles previously analyzed by X-ray diffraction (XRD) or mineral mixtures prepared in the lab.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Roofing provides the main protection against direct solar radiation in animal housing. Appropriate thermal properties of roofing materials tend to improve the thermal comfort in the inner ambient. Nonasbestos fiber-cement roofing components reinforced with cellulose pulp from sisal (Agave sisalana) were produced by slurry and dewatering techniques, with an optional addition of polypropylene fibers. Nonasbestos tiles were evaluated and compared with commercially available asbestos-cement sheets and ceramic tiles (frequently chosen as roofing materials for animal housing). Thermal conductivity and thermal diffusivity of tiles were determined by the parallel hot-wire method, along with the evaluation of the downside surface temperature. Cement-based components reinforced with sisal pulp presented better thermal performance at room temperature (25ºC), while those reinforced with sisal pulp added by polypropylene fibers presented better thermal performance at 60ºC. Non-asbestos cement tiles provided more efficient protection against radiation than asbestos corrugated sheets.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Mechanical and tribological properties of a partially crystallized sintered glass-ceramic were compared to two commercial floor tiles: black granite and porcelainized stoneware. Mechanical properties, hardness and elastic modulus were evaluated by instrumented indentation. Friction coefficient and wear characterization were evaluated using a reciprocating ball-on-flat tribometer in two controlled environments: air with relative humidity of 53% and under running water at 23 degrees C. The sintered glass-ceramic and porcelainized stoneware presented similar mechanical and tribological properties. Regarding the mechanical and tribological properties, the results suggest that this glass-ceramic is suitable to be used as industrial tile. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Como o sector cerâmico é um consumidor intensivo de energia, este trabalho teve como objectivo principal a elaboração de um plano de optimização do desempenho energético da olaria número três da Fábrica Cerâmica de Valadares. Para o efeito, efectuou-se o levantamento energético desta fracção autónoma. O valor total obtido para os ganhos térmicos foi de 8,7x107 kJ/dia, sendo 82% desta energia obtida na combustão do gás natural. Por outro lado, as perdas energéticas rondam os 8,2x107 kJ/dia, sendo o ar de exaustão e a envolvente os principais responsáveis, com um peso de 42 % e 38%, respectivamente. Tendo em conta estes valores, estudaram-se várias medidas de isolamento da cobertura, pavimento, paredes e saída de ar através de fendas do edifício. No caso do isolamento da cobertura sugeriu-se a substituição das telhas de fibrocimento e do isolamento actualmente existentes por painéis sandwich de cobertura. Esta acção permite uma poupança de 64.796€/ano, com um investimento de 57.029€ e o seu período de retorno de 0,9 anos. O Valor Actualizado Líquido (VAL) no 5º ano foi de 184.069€, com uma Taxa Interna de Rentabilidade (TIR) de 92%. Para isolar o pavimento, sugeriu-se a utilização de placas de poliuretano expandido (PU) de 20mm de espessura. Assim, consegue-se uma poupança de 7.442 €/ano, com um investimento de 21.708€, e um tempo de retorno 2,9 anos. No final do 5º ano de vida útil do projecto, o VAL é de 4.070€ e a TIR 7%. Relativamente ao isolamento das paredes e pilares, sugeriu-se a utilização de placas de PU (30mm), recobertas com chapa de ferro galvanizado. O tempo de retorno do investimento é de 1,5 anos, uma vez que, o investimento é de 13.670€ e a poupança anual será de 9.183€. Esta solução apresenta no último ano um VAL de 12.835€ e uma TIR de 22%. No isolamento das fendas do edifício, sugeriu-se a redução de 20% da sua área livre. Esta medida de optimização implica um investimento de 8.000€, revelando-se suficientemente eficaz, pois apresenta um tempo de retorno de 0,67 anos. O VAL e a TIR da solução no último ano de vida útil do projecto de investimento são de 36.835€ e 35%, respectivamente. Por fim, sugeriu-se ainda a instalação de um sistema de controlo que visa o aproveitamento de ar quente proveniente do forno, instalado no piso inferior à olaria, para pré-aquecer o ar alimentado aos geradores de calor. Esta medida implicaria um investimento de 4.000€, com um tempo de retorno de 2,4 anos e uma poupança anual é de 1.686€. O investimento é aconselhável, já que, no 5º ano, o VAL é de 1.956€ e a TIR é de 17%.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Intern.Conference AZULEJAR, Univ. Aveiro, 10-12 October 2012

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The impact of microbial activity on the deterioration of cultural heritage is a well-recognized global problem. Glazed wall tiles constitute an important part of the worldwide cultural heritage. When exposed outdoors, biological colonization and consequently biodeterioration may occur. Few studies have dealt with this issue, as shown in the literature review on biodiversity, biodeterioration and bioreceptivity of architectural ceramic materials. Due to the lack of knowledge on the biodeteriogens affecting these assets, the characterization of microbial communities growing on Portuguese majolica glazed tiles, from Pena National Palace (Sintra, Portugal) and another from Casa da Pesca (Oeiras, Portugal) was carried out by culture and molecular biology techniques. Microbial communities were composed of microalgae, cyanobacteria, bacteria and fungi, including a new fungal species (Devriesia imbrexigena) described for the first time. Laboratory-based colonization experiments were performed to assess the biodeterioration patterns and bioreceptivity of glazed wall tiles produced in laboratory. Microorganisms previously identified on glazed tiles were inoculated on pristine and artificially aged tile models and incubated under laboratory conditions for 12 months. Phototrophic microorganisms were able to grow into glaze fissures and the tested fungus was able to form oxalates over the glaze. The bioreceptivity of artificially aged tiles was higher for phototrophic microorganisms than pristine tile models. A preliminary approach on mitigation strategies based on in situ application of commercial biocides and titanium dioxide (TiO2) nanoparticles on glazed tiles demonstrated that commercial biocides did not provide long term protection. In contrast, TiO2 treatment caused biofilm detachment. In addition, the use of TiO2 thin films on glazed wall tiles as a protective coating to prevent biological colonization was analysed under laboratorial conditions. Finally, conservation notes on tiles exposed to biological colonization were presented.